Advertisement for orthosearch.org.uk
Results 261 - 280 of 283
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 185 - 189
1 Feb 2009
Pandit H Jenkins C Beard DJ Gallagher J Price AJ Dodd CAF Goodfellow JW Murray DW

We randomised 62 knees to receive either cemented or cementless versions of the Oxford unicompartmental knee replacement. The implants used in both arms of the study were similar, except that the cementless components were coated with porous titanium and hydroxyapatite. The tibial interfaces were studied with fluoroscopically-aligned radiographs.

At one year there was no difference in clinical outcome between the two groups. Narrow radiolucent lines were seen at the bone-implant interfaces in 75% of cemented tibial components. These were partial in 43%, and complete in 32%. In the cementless implants, partial radiolucencies were seen in 7% and complete radiolucencies in none. These differences are statistically significant (p < 0.0001) and imply satisfactory bone ingrowth into the cementless implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1097 - 1100
1 Aug 2008
Tsuchihara T Nemoto K Arino H Amako M Murakami H Yoshizumi Y

Most injuries to the femoral nerve are iatrogenic in origin and occur during resection of large retroperitoneal tumours. When the defect is considerable a nerve graft is mandatory to avoid tension across the suture line. We describe two cases of iatrogenic femoral nerve injury which recovered well after reconstruction with long sural nerve grafts.

The probable reasons for success were that we performed the grafting soon after the injury, the patients were not too old, the nerve repairs were reinforced with fibrin glue and electrical stimulation of the quadriceps was administered to prevent muscle atrophy. Good functional results may be obtained if these conditions are satisfied even if the length of a nerve graft is more than 10 cm.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1323 - 1327
1 Oct 2008
Kim S Lee D Kim T Choi N

We present the operative technique and clinical results of concomitant reconstruction of the medial collateral ligament (MCL) and the posterior oblique ligament for medial instability of the knee using autogenous semitendinosus tendon with preservation of the tibial attachment. The semitendinosus tendon graft between the screw on the medial epicondyle and the tibial attachment of the graft was overlapped by the MCL, while the graft between the screw and the insertion of the direct head of the semimembranosus tendon was overlapped by the central arm of the posterior oblique ligament. Assessment was by stress radiograph and the Lysholm knee scoring scale. After a mean follow-up of 52.6 months (25 to 92), the medial joint opening of the knee was within 2 mm in 22 of 24 patients. The mean Lysholm score was 91.9 (80 to 100).

Concomitant reconstruction of the MCL and posterior oblique ligament using autogenous semitendinosus tendon provides a good solution to medial instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 351 - 356
1 Mar 2009
Parratte S Argenson JA Pearce O Pauly V Auquier P Aubaniac J

We retrospectively reviewed 35 cemented unicompartmental knee replacements performed for medial unicompartmental osteoarthritis of the knee in 31 patients ≤50 years old (mean 46, 31 to 49). Patients were assessed clinically and radiologically using the Knee Society scores at a mean follow-up of 9.7 years (5 to 16) and survival at 12 years was calculated. The mean Knee Society Function Score improved from 54 points (25 to 64) pre-operatively to 89 (80 to 100) post-operatively (p < 0.0001). Six knees required revision, four for polyethylene wear treated with an isolated exchange of the tibial insert, one for aseptic loosening and one for progression of osteoarthritis.

The 12-year survival according to Kaplan-Meier was 80.6% with revision for any reason as the endpoint. Despite encouraging clinical results, polyethylene wear remains a major concern affecting the survival of unicompartmental knee replacement in patients younger than 50.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 287 - 293
1 Mar 2009
Korompilias AV Lykissas MG Beris AE Urbaniak JR Soucacos PN

The management of osteonecrosis of the femoral head ranges from symptomatic therapy to total hip replacement. Conservative treatment is effective only in small, early-stage lesions. Free vascularised fibular grafting has provided more consistently successful results than any other joint-preserving method. It supports the collapsing subchondral plate by primary callus formation, reduces intra-osseous pressure, removes and replaces the necrotic segment, and adds viable cortical bone graft plus fresh cancellous graft, which has osseoinductive and osseoconductive potential. Factors predisposing to success are the aetiology, stage and size of the lesion. Furthermore, it is a hip-salvaging procedure in early pre-collapse stages, and a time-buying one when the femoral head has collapsed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 821 - 824
1 Jun 2007
Ogawa BK Kay RM Choi PD Stevanovic MV

The management of closed fractures of the humerus with an associated nerve palsy remains controversial. With very little written about this injury in children, we present the case of a three-year-old child with a closed humeral shaft fracture in whom surgical exploration and reconstruction of the radial nerve with a sural nerve graft was performed three months after injury. The child regained full function. To the best of our knowledge, this is the first such case to be reported in the English literature.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 827 - 832
1 Jul 2008
Rees JL

This review discusses the pathogenesis and surgical treatment of tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1553 - 1555
1 Nov 2005
Matsumine A Kusuzaki K Hirata H Fukutome K Maeda M Uchida A

We describe a case of intraneural metastasis of a synovial sarcoma, the first published case of a metastasis of a soft-tissue sarcoma to a peripheral nerve.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 830 - 835
1 Jun 2007
Hara Y Ochiai N Abe I Ichimura H Saijilafu Nishiura Y

We investigated the effect of progesterone on the nerve during lengthening of the limb in rats. The sciatic nerves of rats were elongated by leg lengthening for ten days at 3 mm per day. On alternate days between the day after the operation and nerve dissection, the progesterone-treated group received subcutaneous injections of 1 mg progesterone in sesame oil and the control group received oil only. On the fifth, tenth and 17th day, the sciatic nerves were excised at the midpoint of the femur and the mRNA expression level of myelin protein P0 was analysed by quantitative real time polymerase chain reaction. On day 52 nodal length was examined by electron microscopy, followed by an examination of the compound muscle action potential (C-MAP) amplitude and the motor conduction velocity (MCV) of the tibial nerve on days 17 and 52. The P0 (a major myelin glycoprotein) mRNA expression level in the progesterone-treated group increased by 46.6% and 38.7% on days five and ten, respectively. On day 52, the nodal length in the progesterone-treated group was smaller than that in the control group, and the MCV of the progesterone-treated group had been restored to normal.

Progesterone might accelerate the restoration of demyelination caused by nerve elongation by activating myelin synthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 584 - 591
1 May 2008
Karachalios T Giotikas D Roidis N Poultsides L Bargiotas K Malizos KN

We report the clinical and radiological results of a two- to three-year prospective randomised study which was designed to compare a minimally-invasive technique with a standard technique in total knee replacement and was undertaken between January 2004 and May 2007. The mini-midvastus approach was used on 50 patients (group A) and a standard approach on 50 patients (group B). The mean follow-up in both groups was 23 months (24 to 35).

The functional outcome was better in group A up to nine months after operation, as shown by statistically significant differences in the mean function score, mean total score and the mean Oxford knee score (all, p = 0.05). Patients in group A had statistically significant greater early flexion (p = 0.04) and reached their greatest mean knee flexion of 126.5° (95° to 135°) 21 days after operation. However, at final follow-up there was no significant difference in the mean maximum flexion between the groups (p = 0.08). Technical errors were identified in six patients from group A (12%) on radiological evaluation.

Based on these results, the authors currently use minimally-invasive techniques in total knee replacement in selected cases only.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 863 - 866
1 Jun 2005
Nagarajah K Aslam N McLardy Smith P McNally M

We describe a technique of ‘cross-hip distraction’ to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 841 - 843
1 Jun 2005
Zamzam MM Khoshhal KI

We retrospectively reviewed 183 children with a simple fracture of the distal radius, with or without fracture of the ulna, treated by closed reduction and cast immobilisation. The fracture redisplaced after an initial, acceptable closed reduction in 46 (25%). Complete initial displacement was identified as the most important factor leading to redisplacement. Other contributing factors were the presence of an ipsilateral distal ulnar fracture, and the reduction of completely displaced fractures under deep sedation or local haematoma block. We recommend that completely displaced fractures of the distal radius in children should be reduced under general anaesthesia, and fixed by primary percutaneous Kirschner wires even when a satisfactory closed reduction has been achieved.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1448 - 1453
1 Nov 2006
Chen AF Alan RK Redziniak DE Tria AJ

The aim of this study was to compare the results in patients having a quadriceps sparing total knee replacement (TKR) with those undergoing a standard TKR at a minimum follow-up of two years.

All patients who had a TKR with a high-flex posterior-stabilised prosthesis prior to December 2002 were reviewed retrospectively. There were 57 patients available for follow-up. Those with a quadriceps sparing TKR had less pain peri-operatively with a greater degree of flexion at all the post-operative visits and at the final follow-up, but their operations took longer, with less accurate radiological alignment. There was no difference in the complications and in the Knee Society scores between the two groups at the final follow-up.

Total knee replacement through a quadriceps sparing approach has some peri-operative advantages over the standard incision. At a minimum follow-up of two years the clinical results were similar to those with a standard incision, but the radiological outcomes of the quadriceps sparing group were inferior.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 664 - 667
1 May 2005
Niall DM Nutton RW Keating JF

Injury to the common peroneal nerve was present in 14 of 55 patients (25%) with dislocation of the knee. All underwent ligament reconstruction. The most common presenting direction of the dislocation was anterior or anteromedial with associated disruption of both cruciate ligaments and the posterolateral structures of the knee. Palsy of the common peroneal nerve was present in 14 of 34 (41%) of these patients. Complete rupture of the nerve was seen in four patients and a lesion in continuity in ten.

Three patients with lesions in continuity, but with less than 7 cm of the nerve involved, had complete recovery within six to 18 months. In the remaining seven with more extensive lesions, two regained no motor function, and one had only MRC grade-2 function. Four patients regained some weak dorsiflexion or eversion (MRC grade 3 or 4). Some sensory recovery occurred in all seven of these patients, but was incomplete. In summary, complete recovery occurred in three (21%) and partial recovery of useful motor function in four (29%). In the other seven (50%) no useful motor or sensory function returned.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 706 - 711
1 Jun 2006
Robertson A Nutton RW Keating JF


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 191 - 195
1 Feb 2005
Mighell MA Dunham RC Rommel EA Frankle MA

We present six patients with chronic dislocation of the elbow who were treated by primary semiconstrained total elbow arthroplasty. All were women with a mean age of 65 years (51 to 76), the mean interval between dislocation and surgery was 17 weeks (5 to 52) and the mean follow-up 58 months (24 to 123).

The most dramatic improvement was in function. The mean American Shoulder and Elbow Surgeon score was 5.2 times better (p < 0.001) and the mean total range of movement increased from 33° to 121° (p < 0.001) after operation. Three patients developed wear of polyethylene. One required revision for a periprosthetic fracture, and another required a bushing exchange.

Primary semiconstrained elbow arthroplasty provides significant, predictable functional improvement. Potential solutions for wear of polyethylene include a different operative technique or design of implant. Despite the high incidence of such wear, total elbow arthroplasty should be considered as a viable treatment option for chronic dislocation of the elbow in elderly patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 265 - 272
1 Feb 2007
Ristiniemi J Flinkkilä T Hyvönen P Lakovaara M Pakarinen H Jalovaara P

External fixation of distal tibial fractures is often associated with delayed union. We have investigated whether union can be enhanced by using recombinant bone morphogenetic protein-7 (rhBMP-7).

Osteoinduction with rhBMP-7 and bovine collagen was used in 20 patients with distal tibial fractures which had been treated by external fixation (BMP group). Healing of the fracture was compared with that of 20 matched patients in whom treatment was similar except that rhBMP-7 was not used.

Significantly more fractures had healed by 16 (p = 0.039) and 20 weeks (p = 0.022) in the BMP group compared with the matched group. The mean time to union (p = 0.002), the duration of absence from work (p = 0.018) and the time for which external fixation was required (p = 0.037) were significantly shorter in the BMP group than in the matched group. Secondary intervention due to delayed healing was required in two patients in the BMP group and seven in the matched group.

RhBMP-7 can enhance the union of distal tibial fractures treated by external fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1248 - 1252
1 Sep 2005
Awad JN Kebaish KM Donigan J Cohen DB Kostuik JP

In order to identify the risk factors and the incidence of post-operative spinal epidural haematoma, we analysed the records of 14 932 patients undergoing spinal surgery between 1984 and 2002. Of these, 32 (0.2%) required re-operation within one week of the initial procedure and had an International Classification of Diseases (ICD)-9 code for haematoma complicating a procedure (998.12). As controls, we selected those who had undergone a procedure of equal complexity by the same surgeon but who had not developed this complication. Risks identified before operation were older than 60 years of age, the use of pre-operative non-steroidal anti-inflammatories and Rh-positive blood type. Those during the procedure were involvement of more than five operative levels, a haemoglobin < 10 g/dL, and blood loss > 1 L, and after operation an international normalised ratio > 2.0 within the first 48 hours. All these were identified as significant (p < 0.03). Well-controlled anticoagulation and the use of drains were not associated with an increased risk of post-operative spinal epidural haematoma.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 704 - 709
1 May 2005
Chen TH Chen WM Huang CK

We reviewed 29 patients who had undergone intercalary resection for malignant tumours. Of these, 14 had received segmental allograft reconstruction and 15 extracorporeally-irradiated autograft.

At a mean follow-up of 71 months (24 to 132), 20 were free from disease, five had died and four were alive with pulmonary metastases. Two patients, one with an allograft and one with an irradiated autograft, had a local recurrence. Reconstruction with extracorporeally-irradiated autograft has a significantly lower rate of nonunion (7% vs 43%, p = 0.031) but an insignificantly higher rate of fracture (20% vs 14%, p = 0.535) than that with segmental allograft. Using the Enneking functional evaluation system, the mean postoperative score for the patients without local recurrence was 87% (80% to 96%) and was similar in both groups.

Extracorporeally-irradiated autograft could be an acceptable alternative for reconstruction after intercalary resection, especially in countries where it is difficult to obtain allografts.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1292 - 1297
1 Sep 2005
Lietman SA Inoue N Rafiee B Deitz LW Chao EYS

We used a canine intercalary bone defect model to determine the effects of recombinant human osteogenic protein 1 (rhOP-1) on allograft incorporation. The allograft was treated with an implant made up of rhOP-1 and type I collagen or with type I collagen alone.

Radiographic analysis showed an increased volume of periosteal callus in both test groups compared with the control group at weeks 4, 6, 8 and 10. Mechanical testing after 12 weeks revealed increased maximal torque and stiffness in the rhOP-1 treated groups compared with the control group.

These results indicate a benefit from the use of an rhOP-1 implant in the healing of bone allografts. The effect was independent of the position of the implant. There may be a beneficial clinical application for this treatment.