Advertisement for orthosearch.org.uk
Results 261 - 266 of 266
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1593 - 1594
1 Dec 2005
Carr AJ


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 160 - 165
1 Feb 2007
Blomfeldt R Törnkvist H Eriksson K Söderqvist A Ponzer S Tidermark J

The best treatment for the active and lucid elderly patient with a displaced intracapsular fracture of the femoral neck is still controversial. Randomised controlled trials have shown that a primary total hip replacement is superior to internal fixation as regards the need for secondary surgery, hip function and health-related quality of life. Despite good results achieved with total hip replacement in this group, most orthopaedic surgeons still advocate hemiarthroplasty for this injury. We studied 120 patients with a mean age of 81 years (70 to 90) with an acute displaced intracapsular fracture of the femoral neck. They were randomly allocated to be treated with either a bipolar hemiarthroplasty or total hip replacement. Outcome measurements included peri-operative data, general and hip-specific complications, hip function and health-related quality of life. The patients were reviewed at four and 12 months.

The duration of surgery was longer in the total hip replacement group (102 minutes (70 to 151)) versus 78 minutes (43 to 131) (p < 0.001), and the intra-operative blood loss was increased 460 ml (100 to 1100) versus 320 ml (50 to 850) (p < 0.001), but there were no differences between the groups regarding any complications or mortality. There were no dislocations in either group. Hip function measured by the Harris hip score was significantly better in the total hip replacement group at both follow-up periods (p = 0.011 and p < 0.001, respectively). The health-related quality of life measure was in favour of the total hip replacement group but did not reach statistical significance (p = 0.818 at four months and p = 0.636 at 12 months).

These results indicate that a total hip replacement provides better function than a bipolar hemiarthroplasty as soon as one year post-operatively, without increasing the complication rate. We recommend total hip replacement as the primary treatment for this group of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 969 - 973
1 Jul 2005
Laird A Keating JF

We prospectively analysed the epidemiology of acetabular fractures over a period of 16 years in order to identify changes in their incidence or other demographic features. Our study cohort comprised a consecutive series of 351 patients with acetabular fractures admitted to a single institution between January 1988 and December 2003.

There was no significant change in the overall incidence of acetabular fractures, which remained at 3 patients/100 000/year. There was, however, a significant reduction in the number of men sustaining an acetabular fracture over the period (p < 0.02). The number of fractures resulting from falls from a height < 10 feet showed a significant increase (p < 0.002), but there was no change in those caused by motor-vehicle accidents. There was a significant reduction in the median Injury Severity score over the period which was associated with a significant decrease in mortality (p < 0.04) and a reduction in the length of hospital stay. The incidence of osteoarthritis noted during follow-up of operatively-treated fractures declined from 31% to 14%, reflecting improved results with increasing subspecialisation. Our findings suggest that there will be a continuing need for some orthopaedic surgeons to specialise in the management of these fractures. In addition, the reductions in the Injury Severity score and mortality may be associated with improved road and vehicle safety.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 608 - 617
1 May 2005
Bauer HCF


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 609 - 614
1 May 2007
Himanen A Belt EA Lehto MUK Hämäläinen MMJ

We evaluated the survival of moulded monoblock and modular tibial components of the AGC total knee replacement in patients with rheumatoid arthritis. Between 1985 and 1995, 751 knees with this diagnosis were replaced at our institution. A total of 256 tibial components were of the moulded design and 495 of the modular design. The mean follow-up of the moulded subgroup was 9.6 years (0.5 to 14.7), and that of the modular group 7.0 years (0.1 to 14.7).

The groups differed significantly from each other in Larsen grade, cementing of components and patellar resurfacing, but no statistically significant difference between the survival of the components was found (Log rank test, p = 0.91). The cumulative success rate of the moulded group was 96.8% (95% confidence interval 93.6% to 98.4%) at five years and 94.4% (95% confidence interval 90.4% to 96.7%) at ten years, and of the modular group 96.2% (95% confidence interval 94% to 97.6%) and 93.6% (95% confidence interval 89.7% to 96%), respectively. Revision was required in 37 total knee replacements, the main causes were infection, pain, loosening of the tibial component and patellar problems. Survival rates for both components were satisfactory.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 366 - 373
1 Mar 2006
Baumann C Rat AC Osnowycz G Mainard D Delagoutte JP Cuny C Guillemin F

We conducted a multicentre cohort study of 228 patients with osteoarthritis followed up after total hip or knee replacement. Quality of life and patient satisfaction were assessed by self-administered questionnaires. Patient satisfaction was the dependent variable in a multivariate linear regression model. Independent variables included sociodemographic factors, pre- and post-operative clinical characteristics and the pre-operative and post-discharge health-related quality of life.

The mean age of the patients was 69 years (sd 9), and 43.8% were male. Pre- and postoperative clinical characteristics were not associated with satisfaction with health care. Only pre-operative bodily pain (p < 0.01) and pre-operative social functioning (p < 0.05) influenced patient satisfaction with care.

The pre-operative health-related quality of life and patient characteristics have little effect on inpatient satisfaction with care. This suggests that the impact of the care process on satisfaction may be independent of observed and perceived initial patient-related characteristics.