Advertisement for orthosearch.org.uk
Results 261 - 280 of 499
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 4 | Pages 730 - 735
1 Nov 1960
Somerville EW

1. The nature of flexion contractures of the knee joint is discussed. 2. It is suggested that division of the anterior cruciate ligament will help in the correction of the deformity when conservative methods have failed. 3. The results of the treatment of twelve such knees are mentioned and illustrative cases are described. 4. It must be emphasised that this method of treatment should be undertaken only when conservative methods have failed


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 632 - 637
1 May 2020
Gonzalez LJ Hildebrandt K Carlock K Konda SR Egol KA

Aims

Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques.

Methods

In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired t-test.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 49 - 58
1 Jun 2020
Mullaji A

Aims

The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA).

Methods

A total of 492 consecutive, cemented, cruciate-substituting TKAs performed for varus osteoarthritis were studied. After exposure and excision of both cruciates and menisci, it was noted from operative records the corrective interventions performed in each case. Knees in which no releases after the initial exposure, those which had only osteophyte excision, and those in which further interventions were performed were identified. From recorded navigation data, coronal and sagittal limb alignment, knee flexion range, and medial and lateral gap distances in maximum knee extension and 90° knee flexion with maximal varus and valgus stresses, were established, initially after exposure and excision of both cruciate ligaments, and then also at trialling. Knees were defined as ‘aligned’ if the hip-knee-ankle axis was between 177° and 180°, (0° to 3° varus) and ‘balanced’ if medial and lateral gaps in extension and at 90° flexion were within 2 mm of each other.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 995 - 996
1 Nov 1999
van Huyssteen AL Bracey DJ

We have summarised the clinical and pathological changes in the knees of three patients in whom aqueous chlorhexidine 0.02% had been used as the irrigation solution during arthroscopically-assisted reconstruction of the anterior cruciate ligament. Even very dilute solutions of chlorhexidine can cause marked chondrolysis of articular cartilage leading to severe permanent damage to the knee. Irrigation solutions should be checked carefully to ensure that their composition is appropriate to the procedure being carried out. Exposure of articular cartilage to chlorhexidine should be avoided


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 827 - 828
1 Nov 1986
Kaelin A Hulin P Carlioz H

Instability of the knee is frequently found in association with congenital leg-length discrepancy. We have studied six such patients clinically, radiologically and arthroscopically. Clinical signs of knee instability and significant radiological changes were present in all, and at arthroscopy the anterior cruciate ligament was completely absent in four patients and functionless in the other two. This deficiency appears to be a congenital condition which may predispose to meniscus injury or retropatellar pain; it may also lead to subluxation or dislocation of the knee during leg-lengthening procedures


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 290 - 292
1 Mar 1994
Vanek J

We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and external rotation forces on a flexed knee. It was due to the anterior subluxation of the medial tibial plateau after rupture of the ACL


Bone & Joint 360
Vol. 9, Issue 2 | Pages 39 - 43
1 Apr 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 1 | Pages 112 - 120
1 Feb 1967
Katz MP Grogono BJS Soper KC

Five knees with congenital dislocation were explored. The cruciate ligaments were found to be absent or hypoplastic. The results obtained by reconstructing an anterior cruciate ligament appear to be good. On the basis of dissections of foetal knees we believe that the cruciate ligaments are the main structures preventing an anterior dislocation of the knee in early foetal life; this deviation from the adult pattern is due to the bony configuration of the foetal knee. We therefore postulate that the basic defect in congenital dislocation of the knee is an absence or hypoplasia of the cruciate ligaments


Bone & Joint Research
Vol. 8, Issue 11 | Pages 518 - 525
1 Nov 2019
Whitaker S Edwards JH Guy S Ingham E Herbert A

Objectives

This study investigated the biomechanical performance of decellularized porcine superflexor tendon (pSFT) grafts of varying diameters when utilized in conjunction with contemporary ACL graft fixation systems. This aimed to produce a range of ‘off-the-shelf’ products with predictable mechanical performance, depending on the individual requirements of the patient.

Methods

Decellularized pSFTs were prepared to create double-bundle grafts of 7 mm, 8 mm, and 9 mm diameter. Femoral and tibial fixation systems were simulated utilizing Arthrex suspension devices and interference screws in bovine bone, respectively. Dynamic stiffness and creep were measured, followed by ramp to failure from which linear stiffness and load at failure were measured. The mechanisms of failure were also recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 403 - 405
1 May 1992
Irvine G Glasgow M

We studied arthroscopically the meniscal pathology in 100 patients with functional instability of the knee from isolated rupture of the anterior cruciate ligament at an average time of three years after injury. Meniscal tears were observed in 86 patients and multiple lesions of both menisci were common. An incomplete longitudinal cleavage, visible on both surfaces of the posterior horn, was seen in more than half the knees and seemed to indicate progressive meniscal deterioration. Clinical examination was unreliable and we suggest that arthroscopic assessment is necessary for accurate diagnosis and staging


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 204 - 209
1 Mar 1983
Pournaras J Symeonides P Karkavelas G

The significance of the posterior cruciate ligament in the stability of the knee was investigated in dogs and it was compared with that of the anterior cruciate ligament by studying the changes produced in the knee after transection of either ligament. Osteophyte formation and changes in articular cartilage were less prominent after division of the posterior cruciate ligament. A complete longitudinal tear of the medial meniscus was found in eight out of the 10 dogs who had undergone section of the anterior cruciate but in none of the 10 with section of the posterior cruciate. It appears that, in dogs at least, the posterior cruciate ligament is less important than the anterior in the stability of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 193 - 197
1 Mar 1994
Dandy D Gray A

We describe 129 patients with disabling instability of the knee due to deficiency of the anterior cruciate ligament. They were treated by replacement of the ligament with a Leeds-Keio prosthesis supplemented by an extra-articular MacIntosh lateral substitution reconstruction. After an average period of 71 months a satisfactory outcome was found in only 60% of knees. Nine had required revision because of recurrent instability and the pivot-shift sign had become positive in 40% of patients. In our opinion the long-term results are unsatisfactory when compared with those obtained using a graft from the medial third of the patellar tendon supplemented with a MacIntosh extra-articular tenodesis


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 276 - 279
1 Mar 2020
Oussedik S Abdel MP Victor J Pagnano MW Haddad FS

Dissatisfaction following total knee arthroplasty is a well-documented phenomenon. Although many factors have been implicated, including modifiable and nonmodifiable patient factors, emphasis over the past decade has been on implant alignment and stability as both a cause of, and a solution to, this problem. Several alignment targets have evolved with a proliferation of techniques following the introduction of computer and robotic-assisted surgery. Mechanical alignment targets may achieve mechanically-sound alignment while ignoring the soft tissue envelope; kinematic alignment respects the soft tissue envelope while ignoring the mechanical environment. Functional alignment is proposed as a hybrid technique to allow mechanically-sound, soft tissue-friendly alignment targets to be identified and achieved.

Cite this article: Bone Joint J 2020;102-B(3):276–279.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 18 - 19
1 Jun 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 819 - 824
1 Nov 1989
Amis A

The anteroposterior stability of cadaveric knees was investigated. There was a wide range of normal laxity; knees were more stable at 90 degrees than at 20 degrees flexion. Anterior cruciate ligament implants with different stiffnesses were inserted; normal stability could always be restored, and the stiffness or extensibility of implants did not affect knee behaviour significantly. The tightness of implants was critical--small tensioning errors caused subluxation, inhibited knee extension and allowed damagingly high implant tensions. It is concluded that the tension of ligament implants could not be adjusted simply with a pre-set instrument; the procedure will remain critically dependent on the judgment of the operating surgeon


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 453 - 457
1 May 1986
Paterson F Trickey E

We have reviewed 40 patients after replacement of a ruptured anterior cruciate ligament with a free graft of the medial third of the patellar tendon, combining this in 17 of the cases with a MacIntosh extra-articular tenodesis. The average age of the patients at operation was 25.4 years; instability of the knee had been present for 1.5 to 9 years, and the mean follow-up was 2.9 years. The results, assessed on subjective stability, were good in 29 patients, over half being able to return to their original sport, and fair in eight. The technique of operation for free patellar tendon grafting is described in detail and the indications for this and for an additional MacIntosh tenodesis are discussed


Bone & Joint 360
Vol. 9, Issue 1 | Pages 24 - 25
1 Feb 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 225 - 230
1 Mar 1990
Staubli H Jakob R

We evaluated the accuracy of six clinical tests for posterior instability in 24 knees with acute surgically-proven posterior cruciate ligament injuries and intact anterior cruciate ligaments. We also performed stress radiography under anaesthesia. The gravity sign and the posterior drawer test in near extension and its passive reduction were diagnostic in 20 of the 24 knees, and the active reduction of posterior subluxation was diagnostic in 18. The reversed pivot shift sign helped to diagnose severe posterior and posterolateral subluxations, but the external rotation recurvatum test was negative in all 24 knees. Stress radiography in near extension revealed a highly significant increase in posterior tibial subluxation in the injured knees


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 100 - 105
1 Jan 1988
Bray R Flanagan J Dandy D

Forty-seven patients with disabling instability due to isolated anterior cruciate deficiency are described. None had responded to conservative measures or to attempted correction of internal derangements. Eighteen patients were treated by extra-articular MacIntosh lateral substitution alone, the other 29 were treated by the same procedure combined with carbon-fibre replacement of the anterior cruciate ligament. No statistically significant difference was found between the two groups at six years. A satisfactory outcome was found in 44% of the extra-articular group and 55% of the carbon-fibre group at last review; however, the latter group had more complications. There was a marked deterioration in the quality of results between three and six years in both groups


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 48 - 49
1 Jan 2002
Javed A Siddique M Vaghela M Hui ACW

We carried out a prospective study in order to establish to what extent the intra-articular evaluation undertaken during arthroscopy of the knee differed between surgeons. Two senior specialist registrars and a consultant orthopaedic surgeon with a special interest in knee surgery were involved. A total of 78 knee arthroscopies (78 patients) was studied. Arthroscopy was first carried out by the trainee and then by the senior author (ACWH). The intra-articular evaluation during the arthroscopy was recorded independently by a third person in the operating theatre. Data were collected to record variations in examination under anaesthesia, the morphology and pathology of the menisci and anterior cruciate ligament and the state of the articular surfaces. The overall interobserver variation was 20% in all categories. We question the published results of intra-articular evaluation during knee arthroscopy when surgeons of different levels of experience are involved in a single study