Advertisement for orthosearch.org.uk
Results 261 - 280 of 1022
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 852 - 859
1 Jul 2019
Reigstad O Holm-Glad T Korslund J Grimsgaard C Thorkildsen R Røkkum M

Aims

Plate and screw fixation has been the standard treatment for painful conditions of the wrist in non-rheumatoid patients in recent decades. We investigated the complications, re-operations, and final outcome in a consecutive series of patients who underwent wrist arthrodesis for non-inflammatory arthritis.

Patients and Methods

A total of 76 patients, including 53 men and 23 women, with a mean age of 50 years (21 to 79) underwent wrist arthrodesis. Complications and re-operations were recorded. At a mean follow-up of 11 years (2 to 18), 63 patients completed questionnaires, and 57 attended for clinical and radiological assessment.


Bone & Joint 360
Vol. 8, Issue 3 | Pages 19 - 21
1 Jun 2019


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 682 - 690
1 Jun 2019
Scheidegger P Horn Lang T Schweizer C Zwicky L Hintermann B

Aims

There is little information about how to manage patients with a recurvatum deformity of the distal tibia and osteoarthritis (OA) of the ankle. The aim of this study was to evaluate the functional and radiological outcome of addressing this deformity using a flexion osteotomy and to assess the progression of OA after this procedure.

Patients and Methods

A total of 39 patients (12 women, 27 men; mean age 47 years (28 to 72)) with a distal tibial recurvatum deformity were treated with a flexion osteotomy, between 2010 and 2015. Nine patients (23%) subsequently required conversion to either a total ankle arthroplasty (seven) or an arthrodesis (two) after a mean of 21 months (9 to 36). A total of 30 patients (77%), with a mean follow-up of 30 months (24 to 76), remained for further evaluation. Functional outcome, sagittal ankle joint OA using a modified Kellgren and Lawrence Score, tibial lateral surface (TLS) angle, and talar offset ratio (TOR) were evaluated on pre- and postoperative weight-bearing radiographs.


Objectives

Bioresorbable orthopaedic devices with calcium phosphate (CaP) fillers are commercially available on the assumption that increased calcium (Ca) locally drives new bone formation, but the clinical benefits are unknown. Electron beam (EB) irradiation of polymer devices has been shown to enhance the release of Ca. The aims of this study were to: 1) establish the biological safety of EB surface-modified bioresorbable devices; 2) test the release kinetics of CaP from a polymer device; and 3) establish any subsequent beneficial effects on bone repair in vivo.

Methods

ActivaScrew Interference (Bioretec Ltd, Tampere, Finland) and poly(L-lactide-co-glycolide) (PLGA) orthopaedic screws containing 10 wt% β-tricalcium phosphate (β-TCP) underwent EB treatment. In vitro degradation over 36 weeks was investigated by recording mass loss, pH change, and Ca release. Implant performance was investigated in vivo over 36 weeks using a lapine femoral condyle model. Bone growth and osteoclast activity were assessed by histology and enzyme histochemistry.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 695 - 701
1 Jun 2019
Yang H Wang S Lee K

Aims

The purpose of this study was to determine the functional outcome and implant survivorship of mobile-bearing total ankle arthroplasty (TAA) performed by a single surgeon.

Patients and Methods

We reviewed 205 consecutive patients (210 ankles) who had undergone mobile-bearing TAA (205 patients) for osteoarthritis of the ankle between January 2005 and December 2015. Their mean follow-up was 6.4 years (2.0 to 13.4). Functional outcome was assessed using the Ankle Osteoarthritis Scale, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, 36-Item Short-Form Health Survey (SF-36) score, visual analogue scale, and range of movement. Implant survivorship and complications were also evaluated.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 88 - 91
1 Nov 2013
Su EP Su SL

Surface hip replacement (SHR) is generally used in younger, active patients as an alternative conventional total hip replacement in part because of the ability to preserve femoral bone. This major benefit of surface replacement will only hold true if revision procedures of SHRs are found to provide good clinical results. A retrospective review of SHR revisions between 2007 and 2012 was presented, and the type of revision and aetiologies were recorded. There were 55 SHR revisions, of which 27 were in women. At a mean follow-up of 2.3 years (0.72 to 6.4), the mean post-operative Harris hip score (HHS) was 94.8 (66 to 100). Overall 23 were revised for mechanical reasons, nine for impingement, 13 for metallosis, nine for unexplained pain and one for sepsis. Of the type of revision surgery performed, 14 were femoral-only revisions; four were acetabular-only revisions, and 37 were complete revisions. We did not find that clinical scores were significantly different between gender or different types of revisions. However, the mean post-operative HHS was significantly lower in patients revised for unexplained pain compared with patients revised for mechanical reasons (86.9 (66 to 100) versus 99 (96 to 100); p = 0.029). There were two re-revisions for infection in the entire cohort. Based on the overall clinical results, we believe that revision of SHR can have good or excellent results and warrants a continued use of the procedure in selected patients. Close monitoring of these patients facilitates early intervention, as we believe that tissue damage may be related to the duration of an ongoing problem. There should be a low threshold to revise a surface replacement if there is component malposition, rising metal ion levels, or evidence of soft-tissue abnormalities. Cite this article: Bone Joint J 2013;95-B, Supple A:88–91


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 427 - 430
1 May 1999
Wroblewski BM Fleming PA Siney PD

We reviewed 261 patients with 320 Charnley low-friction arthroplasties who had a mean follow-up of 22 years 10 months (20 to 30). Of these, 93.9% considered the operation to be a success; 82.3% were free from pain and 11.6% had occasional discomfort. Satisfactory function was achieved in 59.6% and 62% had an excellent range of movement. The clinical results did not correlate well with the radiological appearance; radiologically loose components did not affect the clinical outcome. The main long-term problem was wear and loosening of the UHMWPE cup. Our findings suggest that the radiological appearance of the arthroplasty is a more reliable indication of the state of the arthroplasty than the clinical results


Bone & Joint Research
Vol. 8, Issue 5 | Pages 199 - 206
1 May 2019
Romanò CL Tsuchiya H Morelli I Battaglia AG Drago L

Implant-related infection is one of the leading reasons for failure in orthopaedics and trauma, and results in high social and economic costs. Various antibacterial coating technologies have proven to be safe and effective both in preclinical and clinical studies, with post-surgical implant-related infections reduced by 90% in some cases, depending on the type of coating and experimental setup used. Economic assessment may enable the cost-to-benefit profile of any given antibacterial coating to be defined, based on the expected infection rate with and without the coating, the cost of the infection management, and the cost of the coating. After reviewing the latest evidence on the available antibacterial coatings, we quantified the impact caused by delaying their large-scale application. Considering only joint arthroplasties, our calculations indicated that for an antibacterial coating, with a final user’s cost price of €600 and able to reduce post-surgical infection by 80%, each year of delay to its large-scale application would cause an estimated 35 200 new cases of post-surgical infection in Europe, equating to additional hospital costs of approximately €440 million per year. An adequate reimbursement policy for antibacterial coatings may benefit patients, healthcare systems, and related research, as could faster and more affordable regulatory pathways for the technologies still in the pipeline. This could significantly reduce the social and economic burden of implant-related infections in orthopaedics and trauma.

Cite this article: C. L. Romanò, H. Tsuchiya, I. Morelli, A. G. Battaglia, L. Drago. Antibacterial coating of implants: are we missing something? Bone Joint Res 2019;8:199–206. DOI: 10.1302/2046-3758.85.BJR-2018-0316.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 750 - 755
1 Nov 1988
Phillips T Messieh S

We have analysed the clinical results of a cementless hip replacement using a Moore stem with a smooth surface, and correlated these results with the radiological changes. Forty-two consecutive arthroplasties in 41 patients were studied prospectively and reviewed at a minimum of two and up to six years; 63% had a good clinical result, 18.5% a fair result, and 18.5% a poor result. Thigh pain on weight-bearing was the main problem and was due to loosening of the stem. We caution against the use of this implant in arthritic patients, in whom a good result can be obtained more predictably with cement fixation


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1299 - 1307
1 Oct 2013
Roche AJ Calder JDF

The two main categories of tendo Achillis tendon disorder are broadly classified by anatomical location to include non-insertional and insertional conditions. Non-insertional Achilles tendinopathy is often managed conservatively, and many rehabilitation protocols have been adapted and modified, with excellent clinical results. Emerging and popular alternative therapies, including a variety of injections and extracorporeal shockwave therapy, are often combined with rehabilitation protocols. Surgical approaches have developed, with minimally invasive procedures proving popular. The management of insertional Achilles tendinopathy is improved by recognising coexisting pathologies around the insertion. Conservative rehabilitation protocols as used in non-insertional disorders are thought to prove less successful, but such methods are being modified, with improving results. Treatment such as shockwave therapy is also proving successful. Surgical approaches specific to the diagnosis are constantly evolving, and good results have been achieved


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 502 - 511
1 May 2019
Lidder S Epstein DJ Scott G

Aims

Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components.

Materials and Methods

A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 610 - 614
1 May 2019
Aibinder WR Bartels DW Sperling JW Sanchez-Sotelo J

Aims

Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA).

Patients and Methods

A total of 100 shoulder arthroplasties (35 TSA and 65 RSA) were evaluated at a mean of 3.8 years (3 to 8.3). The mean age at the time of surgery was 68 years (31 to 90). The mean body mass index was 32.7 kg/m2 (17.3 to 66.4).


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 572 - 577
1 May 2003
Theologis TN Harrington ME Thompson N Benson MKD

The aim of this study was to define objectively gait function in children with treated congenital talipes equinovarus (CTEV) and a good clinical result. The study also attempted an analysis of movement within the foot during gait. We compared 20 children with treated CTEV with 15 control subjects. Clinical assessment demonstrated good results from treatment. Three-dimensional gait analysis provided kinematic and kinetic data describing movement and moments at the joints of the lower limb during gait. A new method was used to study movement within the foot during gait. The data on gait showed significantly increased internal rotation of the foot during walking which was partially compensated for by external rotation at the hip. A mild foot drop and reduced plantar flexor power were also observed. Dorsiflexion at the midfoot was significantly increased, which probably compensated for reduced mobility at the hindfoot. Patients treated for CTEV with a good clinical result should be expected to have nearly normal gait and dynamic foot movement, but there may be residual intoeing, mild foot drop, loss of plantar flexor power with compensatory increased midfoot dorsiflexion and external hip rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 376 - 379
1 Apr 2003
Wroblewski BM Siney PD Fleming PA

We have prospectively studied the wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a zirconia femoral head of 22.225 mm diameter on a cemented, triple-tapered, collarless, polished stem, the C Stem. The 71 patients who underwent total hip arthroplasty had a mean follow-up of six years (3 to 8). No patient died or was lost to follow-up. The clinical results were excellent with 96% of patients satisfied. There were no revisions. Two cups were considered to be loose radiologically. One was avulsed from the cement in a skiing accident, with a periprosthetic fracture of the femur, but has remained stable for more than seven years. One femur shows radiological appearances which are compatible with a healing infection. One femoral component is at risk of loosening. The mean rate of penetration of the cup was 0.22 mm/year (0.06 to 0.55). Our results appear to be within the guidelines set by the National Institute of Clinical Excellence. We have discontinued the use of Hylamer despite excellent clinical results and no revisions to date because the high initial rates of penetration did not settle to the expected low levels within the anticipated time


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 649 - 656
1 May 2013
Park C Jang J Lee S Lee W

The purpose of this study was to compare the results of proximal and distal chevron osteotomy in patients with moderate hallux valgus. We retrospectively reviewed 34 proximal chevron osteotomies without lateral release (PCO group) and 33 distal chevron osteotomies (DCO group) performed sequentially by a single surgeon. There were no differences between the groups with regard to age, length of follow-up, demographic or radiological parameters. The clinical results were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) scoring system and the radiological results were compared between the groups. At a mean follow-up of 14.6 months (14 to 32) there were no significant differences in the mean AOFAS scores between the DCO and PCO groups (93.9 (82 to 100) and 91.8 (77 to 100), respectively; p = 0.176). The mean hallux valgus angle, intermetatarsal angle and sesamoid position were the same in both groups. The metatarsal declination angle decreased significantly in the PCO group (p = 0.005) and the mean shortening of the first metatarsal was significantly greater in the DCO group (p < 0.001). We conclude that the clinical and radiological outcome after a DCO is comparable with that after a PCO; longer follow-up would be needed to assess the risk of avascular necrosis. Cite this article: Bone Joint J 2013;95-B:649–56


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1013 - 1016
1 Nov 1999
Doets HC Raven EEJ

We carried out arthrodesis of the radiolunate joint in 46 wrists (38 patients) for pain and ulnar translation of the carpus because of rheumatoid (42) or psoriatic arthritis (4). At follow-up, three patients had died and in three (1 bilateral) an additional midcarpal arthrodesis had been undertaken. The remaining 32 patients (39 wrists) were evaluated after a mean of five years. The clinical results were good with a mean visual analogue score of 8.3 for pain, 7.2 for hand function and 9 for overall satisfaction. Except for palmar flexion, mobility was equal to or better than before operation. Radiologically, there was deterioration of the midcarpal joint with an increase in the Larsen score from 1.8 to 2.7 (p < 0.001), some decrease in carpal height and recurrence of carpal translation. Radiolunate arthrodesis gives good clinical results at five years although there is some deterioration radiologically


Bone & Joint Research
Vol. 8, Issue 5 | Pages 207 - 215
1 May 2019
Key S Scott G Stammers JG Freeman MAR Pinskerova V Field RE Skinner J Banks SA

Objectives

The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities.

Methods

Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 435 - 442
1 Apr 2019
Zambianchi F Franceschi G Rivi E Banchelli F Marcovigi A Nardacchione R Ensini A Catani F

Aims

The purpose of this multicentre observational study was to investigate the association between intraoperative component positioning and soft-tissue balancing on short-term clinical outcomes in patients undergoing robotic-arm assisted unicompartmental knee arthroplasty (UKA).

Patients and Methods

Between 2013 and 2016, 363 patients (395 knees) underwent robotic-arm assisted UKAs at two centres. Pre- and postoperatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS) and Forgotten Joint Score-12 (FJS-12). Results were stratified as “good” and “bad” if KOOS/FJS-12 were more than or equal to 80. Intraoperative, post-implantation robotic data relative to CT-based components placement were collected and classified. Postoperative complications were recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 245 - 251
1 Mar 1994
Neumann L Freund K Sorenson K

We made a prospective study of 241 Charnley total hip replacements performed between 1968 and 1974. In 1990, we reviewed 92 patients with 103 hips (96.3% of surviving hips) at a mean follow-up of 17.6 years (15 to 20.6) The clinical results were excellent, with Charnley scores of 4 or more for pain in 95% of the patients, for function in 73% and for movement in 93%. Of the whole series, 8.3% had been revised, and Kaplan-Meier survival analysis showed a probability of revision at 20 years of 10.7%. These results are similar to those from the few other series with extended follow-up, and make it difficult to justify the present widespread use of uncemented hip prostheses. It would seem that some aspects of the design of the first-generation Charnley stem were beneficial for long-term survival of the arthroplasty. We found no correlation between the clinical results and radiological loosening on the Harris scale


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 390 - 395
1 Apr 2019
Yasunaga Y Tanaka R Mifuji K Shoji T Yamasaki T Adachi N Ochi M

Aims

The aim of this study was to report the long-term results of rotational acetabular osteotomy (RAO) for symptomatic hip dysplasia in patients aged younger than 21 years at the time of surgery.

Patients and Methods

We evaluated 31 patients (37 hips) aged younger than 21 years at the time of surgery retrospectively. There were 29 female and two male patients. Their mean age at the time of surgery was 17.4 years (12 to 21). The mean follow-up was 17.9 years (7 to 30). The RAO was combined with a varus or valgus femoral osteotomy or a greater trochanteric displacement in eight hips, as instability or congruence of the hip could not be corrected adequately using RAO alone.