Advertisement for orthosearch.org.uk
Results 261 - 280 of 753
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 4 | Pages 846 - 854
1 Nov 1956
Holmes F

1. Figures relating to blood loss and post-anaesthetic progress during and after 407 orthopaedic operations performed with the aid of hexamethonium bromide are presented. 2. Two deaths from circulatory failure are examined in detail. 3. The criteria that must be observed to ensure safety are discussed. 4. Measures designed to avoid reactionary haemorrhage are enumerated. 5. Observations regarding contra-indications are presented


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 789 - 793
1 Sep 1993
Radford P Needoff M Webb J

We made a randomised prospective comparison of the Dynamic Hip Screw and the Gamma locking nail for the internal fixation of 200 petrochanteric femoral fractures in elderly patients. There was less intraoperative blood loss and a lower rate of wound complications in the patients treated by the Gamma nail. They had, however, a high incidence of femoral shaft fracture which we relate in part to implant design. We do not recommend the use of the Gamma nail for these fractures


Bone & Joint 360
Vol. 10, Issue 3 | Pages 26 - 29
1 Jun 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 4 | Pages 628 - 638
1 Nov 1971
Macnab I Dall D

1. Intertransverse fusion in the lumbar spine appears to have many advantages over previously described techniques. 2. The disadvantage of profuse bleeding can be overcome by the use of a Hastings frame and by an operative technique designed to demonstrate constant muscular and articular branches of the lumbar arteries. 3. Coagulation of these vessels by cautery and avoidance of dissection anterior to the plane of the transverse processes ensure that the operative procedure can be carried out with a blood loss averaging less than 500 millilitres


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 19 - 22
1 Jan 2002
Kosygan KP Mohan R Newman RJ

We performed a randomised, prospective trial in 111 patients with intertrochanteric fractures of the hip comparing the use of the Gotfried percutaneous compression plate (PCCP) with that of the classic hip screw (CHS). Blood loss and transfusion requirement were less in the PCCP group but the operating time was significantly longer. The complication rate after operation was similar in both groups, and at a minimum follow-up of six months there was no difference in the rates of fracture healing or implant failure. The PCCP gives results which are similar to those obtained with a conventional device. Its suggested advantages seem to be theoretical rather than practical and, being a fixed-angle implant, it is not universally applicable


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 976 - 983
3 May 2021
Demura S Kato S Shinmura K Yokogawa N Shimizu T Handa M Annen R Kobayashi M Yamada Y Murakami H Kawahara N Tomita K Tsuchiya H

Aims

To evaluate the perioperative complications associated with total en bloc spondylectomy (TES) in patients with spinal tumours, based on the extent and level of tumour resection.

Methods

In total, 307 patients who underwent TES in a single centre were reviewed retrospectively. There were 164 male and 143 female patients with a mean age at the time of surgery of 52.9 years (SD 13.3). A total of 225 patients were operated on for spinal metastases, 34 for a malignant primary tumour, 41 for an aggressive benign tumour, and seven with a primary of unknown origin. The main lesion was located in the thoracic spine in 213, and in the lumbar spine in 94 patients. There were 97 patients who underwent TES for more than two consecutive vertebrae.


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1067 - 1074
1 Dec 2021
El-Bakoury A Khedr W Williams M Eid Y Hammad AS

Aims

After failed acetabular fractures, total hip arthroplasty (THA) is a challenging procedure and considered the gold standard treatment. The complexity of the procedure depends on the fracture pattern and the initial fracture management. This study’s primary aim was to evaluate patient-reported outcome measures (PROMs) for patients who underwent delayed uncemented acetabular THA after acetabular fractures. The secondary aims were to assess the radiological outcome and the incidence of the associated complications in those patients.

Methods

A total of 40 patients underwent cementless acetabular THA following failed treatment of acetabular fractures. The postoperative clinical and radiological outcomes were evaluated for all the cohort.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 955 - 958
1 Nov 1991
Dhal A Varghese M Bhasin V

External fixation was used in the treatment of 154 intertrochanteric fractures of the femur over a period of eight years. Good fixation and early ambulation was achieved in all cases. Blood loss was slight. There were 12 deaths due to medical causes unrelated to the surgical procedure. Deep pin-track infection occurred in six cases and late displacement of the fracture fragments in nine. The average time for union was 16 weeks. The technique is simple, quick and inexpensive, and causes minimal surgical trauma. All these features are particularly relevant where resources are limited


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 818 - 821
1 Aug 2003
Hsieh P Chen L Lee M Chen C Yang W Shih C

We retrospectively reviewed 45 hip arthroplasties which were performed over a period of 20 years in 38 patients with cirrhosis of the liver. There was a high perioperative 30-day complication rate (26.7%). Advanced cirrhosis was associated with a higher risk of complications (p = 0.004) as also was increased age, a high level of creatinine, a low level of albumin, a low platelet count, ascites, encephalopathy and an increased operative blood loss. The survival of the prosthesis at five years was 77.8% and infection was a major cause of failure. In view of the high rate of early complications and the limited longevity of the prosthesis, surgeons who perform hip arthroplasty on such patients should counsel them appropriately preoperatively


Bone & Joint 360
Vol. 10, Issue 2 | Pages 37 - 40
1 Apr 2021


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1642 - 1645
1 Nov 2021
Kayani B Giebaly D Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 127 - 129
1 Jan 1988
Rylance P Carli F McArthur S Ransford A Mansell M

The surgical correction of scoliosis in adolescents involves considerable trauma to bone and muscle which, together with hypotensive anaesthesia, might be expected to compromise renal function. Our recent observation of acute renal failure in two such patients prompted a prospective study of renal function following 52 operations in 43 patients. Despite hypotension, blood loss, muscle damage and evidence of fat embolism, renal function was unaltered in all patients, and there was no impairment of spinal cord function. Careful attention was paid to the maintenance of circulating volume which is essential to protect renal perfusion


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 445 - 447
1 May 1993
Desjardins A Roy A Paiement G Newman N Pedlow F Desloges D Turcotte R

We conducted a prospective randomised trial to compare the results of anatomical reduction and medial displacement osteotomy in 127 consecutive patients with unstable intertrochanteric fractures, of whom 109 completed the study. After an average follow-up of 11 months, we found no significant differences in walking ability, social status or failure of fixation in the two groups. Postoperative complication rates and the early mortality rate were not significantly different, but operating time and blood loss were significantly higher in the osteotomy group. With the use of modern sliding hip screws, medial displacement osteotomy is rarely indicated for unstable intertrochanteric fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 322 - 324
1 Mar 1991
Emery R Broughton N Desai K Bulstrode C Thomas T

We performed a randomised prospective trial to compare the results of 27 cemented and 26 uncemented bipolar hemiarthroplasties in active patients with displaced subcapital fractures of the femoral neck. After a mean follow-up of 17 months, significantly more of the uncemented group were experiencing pain in the hip and using more walking aids than the patients in the cemented group. The incidence of postoperative complications, the early mortality rate and the operating time and blood loss were not significantly different. Using otherwise identical prostheses the early results were much better with a cemented Thompson stem than with an uncemented Austin Moore stem


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 773 - 777
1 Sep 1994
McMaster M

Five patients with classical Ehlers-Danlos syndrome developed severe spinal deformities. Two were shown to have type-VI collagen abnormalities. Three had a double structural scoliosis of the thoracic and lumbar regions, one had a single thoracic scoliosis and one had a thoracic kyphosis. The curves first developed before the age of four years, and were not controlled by bracing. Major corrective surgery with posterior fusion was performed at a mean age of 11 years 8 months. Excessive blood loss could be controlled and although wound haematoma and dehiscence were common, they did not provide major problems. The spinal fusions healed satisfactorily


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 556 - 561
1 Jul 1993
Schmidt C Gruen G

We reviewed the outcome, at a mean follow-up of 14 months, of 21 two-column fractures of the acetabulum treated by operation through one or two non-extensile approaches. Eighteen procedures resulted in reduction of the articular surfaces to within 3 mm. The blood loss and operating time when two combined non-extensile approaches were used were similar to those reported for extended acetabular approaches. The incidence of heterotopic ossification which limited joint motion was low, and the average Harris hip score was 81 points. The use of non-extensile approaches for acetabular fractures in which both columns are involved avoids iatrogenic injury to the abductors, and reduces the incidence of complications


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 330 - 334
1 Mar 1991
Bridle S Patel A Bircher M Calvert P

We have prospectively compared the fixation of 100 intertrochanteric fractures of the proximal femur in elderly patients with random use of either a Dynamic Hip Screw (DHS) or a new intramedullary device, the Gamma nail. We found no difference in operating time, blood loss, wound complications, stay in hospital, place of eventual discharge, or the patients' mobility at final review. There was no difference in failure of proximal fixation: cut-out occurred in three cases with the DHS, and twice with the Gamma nail. However, in four cases fracture of the femur occurred close to the Gamma nail, requiring further major surgery. In the absence of these complications, union was seen by six months in both groups


Bone & Joint Research
Vol. 10, Issue 8 | Pages 467 - 473
2 Aug 2021
Rodríguez-Collell JR Mifsut D Ruiz-Sauri A Rodríguez-Pino L González-Soler EM Valverde-Navarro AA

Aims

The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray.

Methods

In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and measured cement layer thickness at both levels of the resected surface of the epiphysis and the endomedular metaphyseal level.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 255 - 258
1 May 1983
Malcolm-Smith N McMaster M

The operative and anaesthesic technique for 44 patients undergoing posterior spinal fusion with Harrington rod instrumentation for idiopathic scoliosis is described. There were two groups of 21 and 23 patients, matched for diagnosis and status before operation. The management of both groups was similar but in one group anaesthesia with induced hypotension was employed, using a mixture of sodium nitroprusside and trimetaphan. The mean blood loss at operation and after operation in this group was significantly lower than in the other group, with a consequent reduction in the transfusion requirement. No adverse sequelae were observed. All patients showed a drop in haemoglobin concentration after operation, despite clinically adequate blood transfusion


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 652 - 654
1 Jul 2000
Tornetta P Tiburzi D

Retrograde femoral nailing is gaining in popularity. We report a prospective, randomised comparison of antegrade and retrograde procedures in 68 patients with 69 fractures of the femoral shaft. All nails were inserted after appropriate reaming. There was no difference in operating time, blood loss, technical complications, size of nail or reamer, or transfusion requirements. There were more problems of length and rotation using a retrograde technique on a radiolucent table than with an antegrade approach on a fracture table. All fractures in both groups healed and there was no difference in the time taken to achieve union. Although retrograde nailing is a promising technique the skills required need practice. A longer period of follow-up is necessary to determine whether there are long-term problems in the knee after such surgery