Advertisement for orthosearch.org.uk
Results 2661 - 2680 of 2732
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1508 - 1512
1 Nov 2006
Wimsey S Pickard R Shaw G

Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient’s thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p < 0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before hip surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1115 - 1121
1 Aug 2007
Messick KJ Miller MA Damron LA Race A Clarke MT Mann KA

The role of vacuum mixing on the reduction of porosity and on the clinical performance of cemented total hip replacements remains uncertain. We have used paired femoral constructs prepared with either hand-mixed or vacuum-mixed cement in a cadaver model which simulated intra-operative conditions during cementing of the femoral component. After the cement had cured, the distribution of its porosity was determined, as was the strength of the cement-stem and cement-bone interfaces.

The overall fraction of the pore area was similar for both hand-mixed and vacuum-mixed cement (hand 6%; vacuum 5.7%; paired t-test, p = 0.187). The linear pore fractions at the interfaces were also similar for the two techniques. The pore number-density was much higher for the hand-mixed cement (paired t-test, p = 0.0013). The strength of the cement-stem interface was greater with the hand-mixed cement (paired t-test, p = 0.0005), while the strength of the cement-bone interface was not affected by the conditions of mixing (paired t-test, p = 0.275). The reduction in porosity with vacuum mixing did not affect the porosity of the mantle, but the distribution of the porosity can be affected by the technique of mixing used.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 933 - 937
1 Jul 2006
Robb JE Brunner R

A total of 47 non-walking patients (52 hips) with severe cerebral palsy and with a mean age of 14 years, (9 to 27) underwent a Dega-type pelvic osteotomy after closure of the triradiate cartilage, together with a derotation varus-shortening femoral osteotomy and soft-tissue correction for hip displacement which caused pain and/or difficulties in sitting. The mean follow-up was 48 months (12 to 153). The migration percentage improved from a pre-operative mean of 70% (26% to 100%) to 10% (0% to 100%) post-operatively. In five hips the post-operative migration percentage was greater than 25%, which was associated with continuing pain in two patients. Three patients had persistent hip pain and a migration percentage less than 25%. In five hips a fracture through the acetabulum occurred, and in another there was avascular necrosis of the superior acetabular segment, but these had no adverse effect on functional outcome. We conclude that it is possible to perform a satisfactory pelvic osteotomy of this type in these patients after the triradiate cartilage has been closed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 296 - 300
1 Mar 2007
van Haaren EH Heyligers IC Alexander FGM Wuisman PIJM

We reviewed the results of 71 revisions of the acetabular component in total hip replacement, using impaction of bone allograft. The mean follow-up was 7.2 years (1.6 to 9.7). All patients were assessed according to the American Academy of Orthopedic Surgeons (AAOS) classification of bone loss, the amount of bone graft required, thickness of the graft layer, signs of graft incorporation and use of augmentation.

A total of 20 acetabular components required re-revision for aseptic loosening, giving an overall survival of 72% (95% CI, 54.4 to 80.5). Of these failures, 14 (70%) had an AAOS type III or IV bone defect. In the failed group, poor radiological and histological graft incorporation was seen.

These results suggest that impaction allografting in acetabular revision with severe bone defects may have poorer results than have previously been reported.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 402 - 404
1 Mar 2006
Boardman DR Middleton FR Kavanagh TG

As metal-on-metal arthroplasty becomes more widespread, concerns are being raised about the potential dangers of metal particulate debris. We present the case of a benign psoas mass secondary to the presence of such particles. The mass was excised and the hip resurfacing subsequently revised to a total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 310 - 315
1 Mar 2007
Ackroyd CE Newman JH Evans R Eldridge JDJ Joslin CC

We report the mid-term results of a new patellofemoral arthroplasty for established isolated patellofemoral arthritis. We have reviewed the experience of 109 consecutive patellofemoral resurfacing arthroplasties in 85 patients who were followed up for at least five years.

The five-year survival rate, with revision as the endpoint, was 95.8% (95% confidence interval 91.8% to 99.8%). There were no cases of loosening of the prosthesis. At five years the median Bristol pain score improved from 15 of 40 points (interquartile range 5 to 20) pre-operatively, to 35 (interquartile range 20 to 40), the median Melbourne score from 10 of 30 points (interquartile range 6 to 15) to 25 (interquartile range 20 to 29), and the median Oxford score from 18 of 48 points (interquartile range 13 to 24) to 39 (interquartile range 24 to 45). Successful results, judged on a Bristol pain score of at least 20 at five years, occurred in 80% (66) of knees. The main complication was radiological progression of arthritis, which occurred in 25 patients (28%) and emphasises the importance of the careful selection of patients. These results give increased confidence in the use of patellofemoral arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1331 - 1335
1 Oct 2006
von Knoch F Böhm T Bürgi ML von Knoch M Bereiter H

We investigated the clinical and radiological outcome of trochleaplasty for recurrent patellar dislocation in association with trochlear dysplasia in 38 consecutive patients (45 knees) with a mean follow-up of 8.3 years (4 to 14).

None had recurrence of dislocation after trochleaplasty. Post-operatively, patellofemoral pain, present pre-operatively in only 35 knees, became worse in 15 (33.4%), remained unchanged in four (8.8%) and improved in 22 (49%). Four knees which had no pain pre-operatively (8.8%) continued to have no pain.

A total of 33 knees were available for radiological assessment. Post-operatively, all but two knees (93.9%) had correction of trochlear dysplasia radiologically but degenerative changes of the patellofemoral joint developed in 30% (10) of the knees.

We conclude that recurrent patellar dislocation associated with trochlear dysplasia can be treated successfully by trochleaplasty, but the impact on patellofemoral pain and the development of patellofemoral osteoarthritis is less predictable. Overall, subjective patient satisfaction with restored patellofemoral stability after trochleaplasty appeared to outweigh its possible sequelae.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 230 - 235
1 Feb 2007
Nakamura J Kamegaya M Saisu T Someya M Koizumi W Moriya H

We reviewed the medical records of 115 patients with 130 hips with developmental dysplasia with complete dislocation in the absence of a neuromuscular disorder, spontaneous reduction with a Pavlik harness, and a minimum of 14 years’ follow-up. The mean age at the time of harness application was 4.8 months (1 to 12) and the mean time spent in the harness was 6.1 months (3 to 12). A total of 108 hips (83.1%) were treated with the harness alone and supplementary surgery for residual acetabular dysplasia, as defined by an acetabular index > 30°, was performed in 22 hips (16.9%).

An overall satisfactory outcome (Severin grade I or II) was achieved in 119 hips (91.5%) at a mean follow-up of 16 years (14 to 32) with a follow-up rate of 75%. Avascular necrosis of the femoral head was noted in 16 hips (12.3%), seven of which (44%) underwent supplementary surgery and nine (56%) of which were classified as satisfactory. The acetabular index was the most reliable predictor of residual acetabular dysplasia.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1158 - 1164
1 Sep 2007
Lusty PJ Watson A Tuke MA Walter WL Walter WK Zicat B

We studied 33 third generation, alumina ceramic-on-ceramic bearings retrieved from cementless total hip replacements after more than six months in situ. Wear volume was measured with a Roundtest machine, and acetabular orientation from the anteroposterior pelvic radiograph. The overall median early wear rate was 0.1 mm3/yr for the femoral heads, and 0.04 mm3/yr for the acetabular liners. We then excluded hips where the components had migrated. In this stable subgroup of 22 bearings, those with an acetabular anteversion of < 15° (seven femoral heads) had a median femoral head wear rate of 1.2 mm3/yr, compared with 0 mm3/yr for those with an anteversion of ≥15° (15 femoral heads, p < 0.001). Even under edge loading, wear volumes with ceramic-on-ceramic bearings are small in comparison to other bearing materials. Low acetabular anteversion is associated with greater wear.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1169 - 1172
1 Sep 2006
Khanduja V Somayaji HS Harnett P Utukuri M Dowd GSE

We report a retrospective analysis of the results of combined arthroscopically-assisted posterior cruciate ligament reconstruction and open reconstruction of the posterolateral corner in 19 patients with chronic (three or more months) symptomatic instability and pain in the knee.

All the operations were performed between 1996 and 2003 and all the patients were assessed pre- and post-operatively by physical examination and by applying three different ligament rating scores. All also had weight-bearing radiographs, MR scans and an examination under anaesthesia and arthroscopy pre-operatively. The posterior cruciate ligament reconstruction was performed using an arthroscopically-assisted single anterolateral bundle technique and the posterolateral corner structures were reconstructed using an open Larson type of tenodesis.

The mean follow up was 66.8 months (24 to 110). Pre-operatively, all the patients had a grade III posterior sag according to Clancy and demonstrated more than 20° of external rotation compared with the opposite normal knee on the Dial test. Post-operatively, seven patients (37%) had no residual posterior sag, 11 (58%) had a grade I posterior sag and one (5%) had a grade II posterior sag. In five patients (26%) there was persistent minimal posterolateral laxity. The Lysholm score improved from a mean of 41.2 (28 to 53) to 76.5 (57 to 100) (p = 0.0001) and the Tegner score from a mean of 2.6 (1 to 4) to 6.4 (4 to 9) (p = 0.0001).

We conclude that while a combined reconstruction of chronic posterior cruciate ligament and posterolateral corner instability improves the function of the knee, it does not restore complete stability.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1212 - 1216
1 Sep 2006
Rastogi S Varshney MK Trikha V Khan SA Choudhury B Safaya R

Aneurysmal bone cyst is a rare tumour-like lesion which develops during growth. Our aim was to determine the efficacy of the administration of percutaneous intralesional 3% polidocanol (hydroxypolyaethoxydodecan) as sclerotherapy.

Between July 1997 and December 2004 we treated 72 patients (46 males, 26 females) with a histologically-proven diagnosis of aneurysmal bone cyst, at various skeletal sites using this method. The sclerotherapy was performed under fluoroscopic guidance and general anaesthesia or sedation and local anaesthesia. The mean follow-up period was 34 months (26.5 to 80). The patients were evaluated using the Enneking system for functional assessment and all the lesions were radiologically quantified into four grades.

The mean age of patients was 15.6 years (3 to 38) and the mean number of injections was three (1 to 5). Ten patients were cured by a single injection. The mean reduction in size of the lesion (radiological healing) was found to be 76.6% (61.9% to 93.2%) with a mean clinical response of 84.5% (73.4% to 100%). Recurrence was seen in two patients (2.8%) within two years of treatment and both were treated successfully by further sclerotherapy.

Percutaneous sclerotherapy with polidocanol is a safe alternative to conventional surgery for the treatment of an aneurysmal bone cyst. It can be used at surgically-inaccessible sites and treatment can be performed on an out-patient basis.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1225 - 1226
1 Sep 2005
Bottomley N Williams A Birch R Noorani A Lewis A Lavelle J

We reviewed the relationship between the pattern of damage to the posterolateral corner of the knee and the position of the common peroneal nerve in 54 consecutive patients with posterolateral corner disruption requiring surgery. We found that 16 of the 18 patients with biceps avulsions or avulsion-fracture of the fibular head had a displaced common peroneal nerve. The nerve was pulled anteriorly with the biceps tendon. None of the 34 proximal injuries resulted in an abnormal nerve position.

Whenever bone or soft-tissue avulsion from the fibular head is suspected, the surgeon should expect an abnormal position of the common peroneal nerve and appreciate the increased risk of iatrogenic damage.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 574 - 580
1 May 2007
Delloye C Cornu O Druez V Barbier O

Bone allografts can be used in any kind of surgery involving bone from minor defects to major bone loss after tumour resection. This review describes the various types of bone grafts and the current knowledge on bone allografts, from procurement and preparation to implantation. The surgical conditions for optimising the incorporation of bone are outlined, and surgeon expectations from a bone allograft discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 127 - 129
1 Jan 2007
Tang TT Lu B Yue B Xie XH Xie YZ Dai KR Lu JX Lou JR

The efficacy of β-tricalcium phosphate (β-TCP) loaded with bone morphogenetic protein-2 (BMP-2)-gene-modified bone-marrow mesenchymal stem cells (BMSCs) was evaluated for the repair of experimentally-induced osteonecrosis of the femoral head in goats.

Bilateral early-stage osteonecrosis was induced in adult goats three weeks after ligation of the lateral and medial circumflex arteries and delivery of liquid nitrogen into the femoral head. After core decompression, porous β-TCP loaded with BMP-2 gene- or β-galactosidase (gal)-gene-transduced BMSCs was implanted into the left and right femoral heads, respectively. At 16 weeks after implantation, there was collapse of the femoral head in the untreated group but not in the BMP-2 or β-gal groups. The femoral heads in the BMP-2 group had a normal density and surface, while those in the β-gal group presented with a low density and an irregular surface. Histologically, new bone and fibrous tissue were formed in the macropores of the β-TCP. Sixteen weeks after implantation, lamellar bone had formed in the BMP-2 group, but there were some empty cavities and residual fibrous tissue in the β-gal group. The new bone volume in the BMP-2 group was significantly higher than that in the β-gal group. The maximum compressive strength and Young’s modulus of the repaired tissue in the BMP-2 group were similar to those of normal bone and significantly higher than those in the β-gal group.

Our findings indicate that porous β-TCP loaded with BMP-2-gene-transduced BMSCs are capable of repairing early-stage, experimentally-induced osteonecrosis of the femoral head and of restoring its mechanical function.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 34 - 38
1 Jan 2007
Epinette J Manley MT

This study describes 146 primary total knee replacements, either fully or partially coated with hydroxyapatite of which 74 knees in 68 patients were available for clinical and radiological assessment at a mean of 11.2 years (10 to 15). The global failure rate was 1.37% and survival rate with mechanical failure as the end-point was 98.14%. Radiological assessment indicated intimate contact between bone and the hydroxyapatite coating. Over time the hydroxyapatite coating appears to encourage filling of interface gaps remaining after surgery. Our results compare favourably with those of series describing cemented or porous-coated knee replacements, and suggest that fixation with hydroxyapatite is a reliable option in primary total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1643 - 1646
1 Dec 2005
Miura H Matsuda S Okazaki K Kawano T Kawamura H Iwamoto Y

We have previously developed a radiographic technique, the oblique posterior condylar view, for assessment of the posterior aspect of the femoral condyles after total knee arthroplasty. The purpose of this study was to confirm the validity of this radiographic view based upon intra-operative findings at revision total knee arthroplasty. Lateral and oblique posterior condylar views were performed for 11 knees prior to revision total knee arthroplasty, and radiolucent lines or osteolysis of the posterior aspect of the femoral condyles were identified. These findings were compared with the intra-operative appearance of the posterior aspects of the femoral condyles. Statistical analysis showed that sensitivity and efficacy were significantly better for the oblique posterior condylar than the lateral view. This method can, therefore, be considered as suitable for routine follow-up radiographs of the femoral component and in the pre-operative planning of revision surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 277 - 278
1 Feb 2005
KIM WY JARI S


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1022 - 1026
1 Aug 2006
Langlais F Belot N Ropars M Lambotte JC Thomazeau H

We evaluated the long-term fixation of 64 press-fit cemented stems of constrained total knee prostheses in 32 young patients with primary malignant bone tumours. Initial stable fixation, especially in rotation, was achieved by precise fit of the stem into the reamed endosteum, before cementation. Complementary fixation, especially in migration and rotation, was obtained by pressurised antibiotic-loaded cement. The mean age at operation was 33 years (13 to 61). No patient was lost to follow-up; 13 patients died and the 19 survivors were examined at a mean follow-up of 12.5 years (4 to 21). Standard revision press-fit cemented stems were used on the side of the joint which was not involved with tumour (26 tibial and six femoral), on this side there was no loosening or osteolysis and stem survival was 100%. On the reconstruction side, custom-made press-fit stems were used and the survival rate, with any cause for revision as an end point, was 88%, but 97% for loosening or osteolysis. This longevity is similar to that achieved at 20 years with the Charnley-Kerboull primary total hip replacement with press-fit cemented femoral components.

We recommend this type of fixation when extensive reconstruction of the knee is required. It may also be suitable for older patients requiring revision of a total knee replacement or in difficult situations such as severe deformity and complex articular fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1137 - 1140
1 Sep 2006
Bircher M Lewis A Halder S

There are unacceptable delays in the management of pelvic trauma in the United Kingdom. In 2003 this became a political issue after TV and radio coverage. Changes to the service were introduced, including trauma coordinators and a special tariff, but has it made a difference?


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1454 - 1459
1 Nov 2006
Brouwer RW Bierma-Zeinstra SMA van Raaij TM Verhaar JAN

A prospective, randomised, controlled trial compared two different techniques of high tibial osteotomy with a lateral closing wedge or a medial opening wedge, stabilised by a Puddu plate. The clinical outcome and radiological results were examined at one year.

The primary outcome measure was the achievement of an overcorrection of valgus of 4°. Secondary outcome measures were the severity of pain (visual analogue scale), knee function (Hospital for Special Surgery score), and walking distance.

Between January 2001 and April 2004, 92 patients were randomised to one or other of the techniques. At follow-up at one year the post-operative hip-knee-ankle angle was 3.4° (± 3.6° sd) valgus after a closing wedge and 1.3° (± 4.7° sd) of valgus after an opening wedge. The adjusted mean difference of 2.1° was significant (p = 0.02). The deviation from 4° of valgus alignment was 2.7° (± 2.4° sd) in the closing wedge and 4.0° (± 3.6° sd) in the opening-wedge groups. The adjusted mean difference of 1.67° was also significant (p = 0.01).

The severity of pain, knee score and walking ability improved in both groups, but the difference was not significant.

Because of pain, the staples required removal in 11 (23%) patients in the closing-wedge group and a Puddu plate was removed in 27 (60%) patients in the opening-wedge group. This difference was significant (p < 0.001).

We conclude that closing-wedge osteotomy achieves a more accurate correction with less morbidity, although both techniques had improved the function of the knee at one year after the procedure.