Aims. The aim of this study was to explore risk factors for complications associated with dural tear (DT), including the types of DT, and the intra- and postoperative management of DT. Patients and Methods. Between 2012 and 2017, 12 171 patients with degenerative lumbar diseases underwent primary lumbar spine
Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres. We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up.Aims
Methods
The principle strategies of fracture-related infection (FRI) treatment are debridement, antimicrobial therapy, and implant retention (DAIR) or debridement, antimicrobial therapy, and implant removal/exchange. Increasing the period between fracture fixation and FRI revision surgery is believed to be associated with higher failure rates after DAIR. However, a clear time-related cut-off has never been scientifically defined. This systematic review analyzed the influence of the interval between fracture fixation and FRI revision surgery on success rates after DAIR. A systematic literature search was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, in PubMed (including MEDLINE), Embase, and Web of Science Core Collection, investigating the outcome after DAIR procedures of long bone FRIs in clinical studies published until January 2020.Aims
Methods
We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one.Aims
Methods
The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.Aims
Methods
The reduction in mobility due to hip diseases in children is likely to affect their physical activity (PA) levels. Physical inactivity negatively influences quality of life and health. Our aim was to objectively measure PA in children with hip disease, and correlate it with the Patient-Reported Outcomes Measurement Information System (PROMIS) Mobility Score. A total of 28 children (12 boys and 16 girls) with hip disease aged between 8and 17 years (mean 12 (SD 3)) were studied between December 2018 and July 2019. Children completed the PROMIS Paediatric Item Bank v. 2.0 – Mobility Short Form 8a and wore a hip accelerometer (ActiGraph) for seven consecutive days. Sedentary time (ST), light PA (LPA), moderate to vigorous PA (MVPA), and vigorous PA were calculated from the accelerometers' data. The PROMIS Mobility score was classified as normal, mild, and moderate functions, based on the PROMIS cut scores on the physical function metric. A one-way analysis of covariance (ANCOVA) was used to assess differences among mobility (normal; mild; moderate) and measured PA and relationships between these variables were assessed using bivariate Pearson correlations.Aims
Methods
Aims. A number of methods have been described to remove a well-fixed humeral implant as part of revision shoulder arthroplasty. These include the use of cortical windows and humeral osteotomies. The router bit extraction technique uses a high-speed router bit to disrupt the bone-implant interface. The implant is then struck in a retrograde fashion with a square-tip impactor and mallet. The purpose of this study was to determine the characteristics and frequency of the different techniques needed for the removal of a well-fixed humeral stem in revision shoulder arthroplasty. Patients and Methods. Between 2010 and 2018, 288 revision shoulder arthroplasty procedures requiring removal of a well-fixed humeral component were carried out at a tertiary referral centre by a single surgeon. The patient demographics, indications for
Aims. Local antibiotics are used in the surgical management of foot infection in diabetic patients. This systematic review analyzes the available evidence of the use of local antibiotic delivery systems as an adjunct to
Using tibial shaft fracture participants from a large, multicentre randomized controlled trial, we investigated if patient and surgical factors were associated with health-related quality of life (HRQoL) at one year post-surgery. The Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) trial examined adults with an open or closed tibial shaft fracture who were treated with either reamed or unreamed intramedullary nails. HRQoL was assessed at hospital discharge (for pre-injury level) and at 12 months post-fracture using the Short Musculoskeletal Functional Assessment (SMFA) Dysfunction, SMFA Bother, 36-Item Short Form 36 (SF-36) Physical, and SF-36 Mental Component scores. We used multiple linear regression analysis to determine if baseline and surgical factors, as well as post-intervention procedures within one year of fracture, were associated with these HRQoL outcomes. Significance was set at p < 0.01. We hypothesize that, irrespective of the four measures used, prognosis is guided by both modifiable and non-modifiable factors and that patients do not return to their pre-injury level of function, nor HRQoL.Aims
Methods
This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the Mayo Elbow Performance Index (MEPI) and range of movement (ROM) after open elbow arthrolysis (OEA). We also assessed the proportion of patients who achieved MCID and SCB; and identified the factors associated with achieving MCID. A cohort of 265 patients treated by OEA were included. The MEPI and ROM were evaluated at baseline and at two-year follow-up. Distribution-based MDC was calculated with confidence intervals (CIs) reflecting 80% (MDC 80), 90% (MDC 90), and 95% (MDC 95) certainty, and MCID with changes from baseline to follow-up. Anchor-based MCID (anchored to somewhat satisfied) and SCB (very satisfied) were calculated using a five-level Likert satisfaction scale. Multivariate logistic regression of factors affecting MCID achievement was performed.Aims
Methods
Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS). Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection.Aims
Methods
This study aimed to identify the tibial component and femoral component coronal angles (TCCAs and FCCAs), which concomitantly are associated with the best outcomes and survivorship in a cohort of fixed-bearing, cemented, medial unicompartmental knee arthroplasties (UKAs). We also investigated the potential two-way interactions between the TCCA and FCCA. Prospectively collected registry data involving 264 UKAs from a single institution were analyzed. The TCCAs and FCCAs were measured on postoperative radiographs and absolute angles were analyzed. Clinical assessment at six months, two years, and ten years was undertaken using the Knee Society Knee score (KSKS) and Knee Society Function score (KSFS), the Oxford Knee Score (OKS), the 36-Item Short-Form Health Survey questionnaire (SF-36), and range of motion (ROM). Fulfilment of expectations and satisfaction was also recorded. Implant survivorship was reviewed at a mean follow-up of 14 years (12 to 16). Multivariate regression models included covariates, TCCA, FCCA, and two-way interactions between them. Partial residual graphs were generated to identify angles associated with the best outcomes. Kaplan-Meier analysis was used to compare implant survivorship between groups.Aims
Methods
To evaluate if union of clavicle fractures can be predicted at six weeks post-injury by the presence of bridging callus on ultrasound. Adult patients managed nonoperatively with a displaced mid-shaft clavicle were recruited prospectively. Ultrasound evaluation of the fracture was undertaken to determine if sonographic bridging callus was present. Clinical risk factors at six weeks were used to stratify patients at high risk of nonunion with a combination of Quick Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) ≥ 40, fracture movement on examination, or absence of callus on radiograph.Aims
Methods
Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures. We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures.Aims
Methods
Aims. The aim of this study was to describe, analyze, and compare the survival, functional outcome, and complications of minimally invasive (MI) and non-invasive (NI) lengthening total femoral prostheses. Patients and Methods. A total of 24 lengthening total femoral prostheses, 11 MI and 13 NI, were implanted between 1991 and 2016. The characteristics, complications, and functional results were recorded. There were ten female patients and ten male patients. Their mean age at the time of
This study, using a surgeon-maintained database, aimed to explore the risk factors for surgery-related complications in patients undergoing primary cervical spine surgery for degenerative diseases. We studied 5,015 patients with degenerative cervical diseases who underwent primary cervical spine surgery from 2012 to 2018. We investigated the effects of diseases, surgical procedures, and patient demographics on surgery-related complications. As subcategories, the presence of cervical kyphosis ≥ 10°, the presence of ossification of the posterior longitudinal ligament (OPLL) with a canal-occupying ratio ≥ 50%, and foraminotomy were selected. The surgery-related complications examined were postoperative upper limb palsy (ULP) with a manual muscle test (MMT) grade of 0 to 2 or a reduction of two grade or more in the MMT, neurological deficit except ULP, dural tear, dural leakage, surgical-site infection (SSI), and postoperative haematoma. Multivariate logistic regression analysis was performed.Aims
Methods
In wound irrigation, 1 mM ethylenediaminetetraacetic acid (EDTA) is more efficacious than normal saline (NS) in removing bacteria from a contaminated wound. However, the optimal EDTA concentration remains unknown for different animal wound models. The cell toxicity of different concentrations of EDTA dissolved in NS (EDTA-NS) was assessed by Cell Counting Kit-8 (CCK-8). Various concentrations of EDTA-NS irrigation solution were compared in three female Sprague-Dawley rat models: 1) a skin defect; 2) a bone exposed; and 3) a wound with an intra-articular implant. All three models were contaminated with Aims
Methods
Patients who sustain neck of femur fractures are at high risk of malnutrition. Our intention was to assess to what extent malnutrition was associated with worse patient outcomes. A total of 1,199 patients with femoral neck fractures presented to a large UK teaching hospital over a three-year period. All patients had nutritional assessments performed using the Malnutrition Universal Screening Tool (MUST). Malnutrition risk was compared to mortality, length of hospital stay, and discharge destination using logistic regression. Adjustments were made for covariates to identify whether malnutrition risk independently affected these outcomes.Aims
Methods
Periprosthetic fractures (PPFs) around cemented taper-slip femoral prostheses often result in a femoral component that is loose at the prosthesis-cement interface, but where the cement-bone interface remains well-fixed and bone stock is good. We aim to understand how best to classify and manage these fractures by using a modification of the Vancouver classification. We reviewed 87 PPFs. Each was a first episode of fracture around a cemented femoral component, where surgical management consisted of revision surgery. Data regarding initial injury, intraoperative findings, and management were prospectively collected. Patient records and serial radiographs were reviewed to determine fracture classification, whether the bone cement was well fixed (B2W) or loose (B2L), and time to fracture union following treatment.Aims
Methods