Advertisement for orthosearch.org.uk
Results 241 - 260 of 272
Results per page:
Bone & Joint 360
Vol. 6, Issue 2 | Pages 14 - 17
1 Apr 2017


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 330 - 336
1 Mar 2017
Sendi P Lötscher PO Kessler B Graber P Zimmerli W Clauss M

Aims

To analyse the effectiveness of debridement and implant retention (DAIR) in patients with hip periprosthetic joint infection (PJI) and the relationship to patient characteristics. The outcome was evaluated in hips with confirmed PJI and a follow-up of not less than two years.

Patients and Methods

Patients in whom DAIR was performed were identified from our hip arthroplasty register (between 2004 and 2013). Adherence to criteria for DAIR was assessed according to a previously published algorithm.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 125 - 126
1 Feb 2018
Haddad FS


Bone & Joint 360
Vol. 7, Issue 2 | Pages 15 - 18
1 Apr 2018


Bone & Joint 360
Vol. 7, Issue 1 | Pages 15 - 17
1 Feb 2018


Bone & Joint 360
Vol. 7, Issue 1 | Pages 12 - 14
1 Feb 2018


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 66 - 72
1 Jan 2018
Suen K Keeka M Ailabouni R Tran P

Aims

α-defensin is a biomarker which has been described as having a high degree of accuracy in the diagnosis of periprosthetic joint infection (PJI). Current meta-analyses are based on the α-defensin laboratory-based immunoassay rather than the quick on-table lateral flow test kit. This study is the first meta-analysis to compare the accuracy of the α-defensin laboratory-based immunoassay and the lateral flow test kit for the diagnosis of PJI.

Materials and Methods

A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Inclusion criteria were all clinical studies where the diagnosis of PJI was uncertain. All studies selected used the Musculoskeletal Infection Society (MSIS) or modified MSIS criteria. Two independent reviewers reviewed the studies and extracted data. A meta-analysis of results was carried out: pooled sensitivity, specificity, positive and negative likelihood ratio, heterogeneity and areas under curves are reported.


Bone & Joint 360
Vol. 6, Issue 5 | Pages 35 - 38
1 Oct 2017


Bone & Joint 360
Vol. 6, Issue 6 | Pages 17 - 20
1 Dec 2017


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1603 - 1610
1 Dec 2017
Dattilo J Gittings D Sloan M Charette R Hume E Lee G

Aims

To evaluate the effectiveness of an institutionally developed algorithm for evaluation and diagnosis of prosthetic joint injection and to determine the impact of this protocol on overall hospital re-admissions.p

Patients and Methods

We retrospectively evaluated 2685 total hip arthroplasty (THA) and total knee arthroplasty (TKA) patients prior to (1263) and following (1422) the introduction of an infection detection protocol. The protocol used conservative thresholds for C-reactive protein to direct the medical attendant to aspirate the joint. The protocol incorporated a clear set of laboratory and clinical criteria that allowed a patient to be discharged home if all were met. Patients were included if they presented to our emergency department within 120 days post-operatively with concerns for swelling, pain or infection and were excluded if they had an unambiguous infection or if their chief complaint was non-orthopaedic in nature.


Bone & Joint 360
Vol. 6, Issue 3 | Pages 35 - 37
1 Jun 2017


Bone & Joint 360
Vol. 6, Issue 5 | Pages 12 - 16
1 Oct 2017


Bone & Joint 360
Vol. 6, Issue 4 | Pages 10 - 13
1 Aug 2017


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 647 - 652
1 May 2017
Abdel MP Ledford CK Kobic A Taunton MJ Hanssen AD

Aims

The number of revision total knee arthroplasties (TKA) that are performed is expected to increase. However, previous reports of the causes of failure after TKA are limited in that they report the causes at specific institutions, which are often dependent on referral patterns. Our aim was to report the most common indications for re-operations and revisions in a large series of posterior-stabilised TKAs undertaken at a single institution, excluding referrals from elsewhere, which may bias the causes of failure.

Patients and Methods

A total of 5098 TKAs which were undertaken between 2000 and 2012 were included in the study. Re-operations, revisions with modular component exchange, and revisions with non-modular component replacement or removal were identified from the medical records. The mean follow-up was five years (two to 12).


The Bone & Joint Journal
Vol. 99-B, Issue 4_Supple_B | Pages 3 - 10
1 Apr 2017
Parvizi J Shohat N Gehrke T

The World Health Organization (WHO) and the Centre for Disease Control and Prevention (CDC) recently published guidelines for the prevention of surgical site infection. The WHO guidelines, if implemented worldwide, could have an immense impact on our practices and those of the CDC have implications for healthcare policy in the United States.

Our aim was to review the strategies for prevention of periprosthetic joint infection in light of these and other recent guidelines.

Cite this article: Bone Joint J 2017;99-B(4 Supple B):3–10.


Bone & Joint 360
Vol. 5, Issue 6 | Pages 16 - 18
1 Dec 2016


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 351 - 357
1 Mar 2017
Sousa R Serrano P Gomes Dias J Oliveira JC Oliveira A

Aims

The aims of this study were to increase the diagnostic accuracy of the analysis of synovial fluid in the differentiation of prosthetic joint infection (PJI) by the addition of inexpensive biomarkers such as the levels of C-reactive protein (CRP), adenosine deaminase (ADA), alpha-2-macrogloblulin (α2M) and procalcitonin.

Patients and Methods

Between January 2013 and December 2015, synovial fluid and removed implants were requested from 143 revision total joint arthroplasties. A total of 55 patients met inclusion criteria of the receipt of sufficient synovial fluid, tissue samples and removed implants for analysis.

The diagnosis of PJI followed the definition from a recent International Consensus Meeting to create two groups of patients; septic and aseptic. Using receiver operating characteristic curves we determined the cutoff values and diagnostic accuracy for each marker.


Bone & Joint 360
Vol. 5, Issue 5 | Pages 10 - 13
1 Oct 2016


Bone & Joint 360
Vol. 5, Issue 3 | Pages 33 - 34
1 Jun 2016


Bone & Joint 360
Vol. 5, Issue 4 | Pages 20 - 22
1 Aug 2016