Advertisement for orthosearch.org.uk
Results 241 - 260 of 403
Results per page:
Bone & Joint 360
Vol. 7, Issue 3 | Pages 31 - 34
1 Jun 2018


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 455 - 460
1 Apr 2018
Mumith A Thomas M Shah Z Coathup M Blunn G

Increasing innovation in rapid prototyping (RP) and additive manufacturing (AM), also known as 3D printing, is bringing about major changes in translational surgical research.

This review describes the current position in the use of additive manufacturing in orthopaedic surgery.

Cite this article: Bone Joint J 2018;100-B:455-60.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 979 - 986
1 Jul 2017
Schwab JH Janssen SJ Paulino Pereira NR Chen YLE Wain JC DeLaney TF Hornicek FJ

Aims

The aim of the study was to compare measures of the quality of life (QOL) after resection of a chordoma of the mobile spine with the national averages in the United States and to assess which factors influenced the QOL, symptoms of anxiety and depression, and coping with pain post-operatively in these patients.

Patients and Methods

A total of 48 consecutive patients who underwent resection of a primary or recurrent chordoma of the mobile spine between 2000 and 2015 were included. A total of 34 patients completed a survey at least 12 months post-operatively. The primary outcome was the EuroQol-5 Dimensions (EQ-5D-3L) questionnaire. Secondary outcomes were the Patient-Reported Outcome Measurement Information System (PROMIS) anxiety, depression and pain interference questionnaires. Data which were recorded included the indication for surgery, the region of the tumour, the number of levels resected, the status of the surgical margins, re-operations, complications, neurological deficit, length of stay in hospital and rate of re-admission.


Bone & Joint 360
Vol. 7, Issue 1 | Pages 25 - 27
1 Feb 2018


Bone & Joint 360
Vol. 6, Issue 6 | Pages 31 - 33
1 Dec 2017


Bone & Joint 360
Vol. 5, Issue 6 | Pages 35 - 37
1 Dec 2016


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1681 - 1688
1 Dec 2017
Jones CW Shatrov J Jagiello JM Millington S Hong A Boyle R Stalley PD

Aims

We present a retrospective review of patients treated with extracorporeally irradiated allografts for primary and secondary bone tumours with the mid- and long-term survivorship and the functional and radiographic outcomes.

Patients and Methods

A total of 113 of 116 (97.4%) patients who were treated with extracorporeally irradiated allografts between 1996 and 2014 were followed up. Forms of treatment included reconstructions, prostheses and composite reconstructions, both with and without vascularised grafts. Survivorship was determined by the Kaplan-Meier method. Clinical outcomes were assessed using the Musculoskeletal Tumor Society (MSTS) scoring system, the Toronto Extremity Salvage Score (TESS) and Quality of Life-C30 (QLQ-30) measures. Radiographic outcomes were assessed using the International Society of Limb Salvage (ISOLS) radiographic scoring system.


Bone & Joint 360
Vol. 6, Issue 5 | Pages 30 - 33
1 Oct 2017


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 666 - 671
1 May 2016
Makino T Kaito T Sakai Y Kashii M Yoshikawa H

Aims

To clarify the asymmetrical ossification of the epiphyseal ring between the convex and concave sides in patients with adolescent idiopathic scoliosis (AIS).

Patients and Methods

A total of 29 female patients (mean age, 14.4 years; 11 to 18) who underwent corrective surgery for AIS (Lenke type 1 or 2) were included in our study. In all, 349 vertebrae including 68 apical vertebrae and 87 end vertebrae in the main thoracic (MT) curve and thoracolumbar/lumbar (TL/L) curve were analysed. Coronal sections (anterior, middle and posterior) of the vertebral bodies were reconstructed from pre-operative CT scans (320-row detector; slice thickness, 0.5 mm) and the appearances of the ossification centre in the epiphyseal ring at four corners were evaluated in three groups; all vertebrae excluding end vertebrae, apical vertebrae and end vertebrae. The appearance rates of the ossification centre at the concave and convex sides were calculated and compared.


We evaluated the outcome of treatment of nonunion of an intracapsular fracture of the femoral neck in young patients using two cannulated screws and a vascularised bone graft. A total of 32 patients (15 women and 17 men, with a mean age of 36.5 years; 20 to 50) with failed internal fixation of an intracapsular fracture were included in the study. Following removal of the primary fixation, two cannulated compression screws were inserted with a vascularised iliac crest bone graft based on the ascending branch of the lateral femoral circumflex artery.

At a mean follow-up of 6.8 years (4 to 10), union was achieved in 27 hips (84%). A total of five patients with a mean age of 40.5 years (35 to 50) had a persistent nonunion and underwent total hip arthroplasty as also did two patients whose fracture united but who developed osteonecrosis of the femoral head two years post-operatively. Statistical analysis showed that younger patients achieved earlier and more reliable union (p < 0.001). The functional outcome, as assessed by the Harris Hip score, was better in patients aged < 45 years compared with those aged > 45 years (p < 0.001).

These findings suggest that further fixation using two cannulated compression screws and a vascularised iliac crest bone graft is an effective salvage treatment in patients aged <  45 years, in whom osteosynthesis of a displaced intracapsular fractures of the femoral neck has failed.

Cite this article: Bone Joint J 2015; 97-B:988–91.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 3 - 5
1 Jan 2016
Birch N


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 555 - 561
1 Apr 2014
Igarashi K Yamamoto N Shirai T Hayashi K Nishida H Kimura H Takeuchi A Tsuchiya H

In 1999, we developed a technique for biological reconstruction after excision of a bone tumour, which involved using autografts of the bone containing the tumour treated with liquid nitrogen. We have previously reported the use of this technique in 28 patients at a mean follow up of 27 months (10 to 54).

In this study, we included 72 patients who underwent reconstruction using this technique. A total of 33 patients died and three were lost to follow-up, at a mean of 23 months (2 to 56) post-operatively, leaving 36 patients available for a assessment at a mean of 101 months 16 to 163) post-operatively. The methods of reconstruction included an osteo-articular graft in 16, an intercalary in 13 and, a composite graft with prosthesis in seven.

Post-operative function was excellent in 26 patients (72.2%), good in seven (19.4%), and fair in three (8.3%) according to the functional evaluation system of Enneking. No recurrent tumour occurred within the grafts. The autografts survived in 29 patients (80.6%), and the rates of survival at five and ten years were 86.1% and 80.6 %, respectively. Seven of 16 osteo-articular grafts (44%) failed because of fracture or infection, but all the composite and intercalary grafts survived.

The long-term outcomes of frozen autografting, particularly using composite and intercalary grafts, are satisfactory and thus represent a good method of treatment for patients with a sarcoma of bone or soft tissue.

Cite this article: Bone Joint J 2014;96-B:555–61.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1237 - 1243
1 Sep 2017
Emori M Kaya M Irifune H Takahashi N Shimizu J Mizushima E Murahashi Y Yamashita T

Aims

The aims of this study were to analyse the long-term outcome of vascularised fibular graft (VFG) reconstruction after tumour resection and to evaluate the usefulness of the method.

Patients and Methods

We retrospectively reviewed 49 patients who had undergone resection of a sarcoma and reconstruction using a VFG between 1988 and 2015. Their mean follow-up was 98 months (5 to 317). Reconstruction was with an osteochondral graft (n = 13), intercalary graft (n = 12), inlay graft (n = 4), or resection arthrodesis (n = 20). We analysed the oncological and functional outcome, and the rate of bony union and complications.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 292 - 299
1 Mar 2015
Karthik K Colegate-Stone T Dasgupta P Tavakkolizadeh A Sinha J

The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics.

Cite this article: Bone Joint J 2015; 97-B:292–9.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 829 - 833
1 Jun 2017
Pereira EAC Oxenham M Lam KS

Aims

In the United Kingdom, lower incidences of intraspinal abnormalities in patients with early onset idiopathic scoliosis have been observed than in studies in other countries. We aimed to determine the rates of these abnormalities in United Kingdom patients diagnosed with idiopathic scoliosis before the age of 11 years.

Patients and Methods

This retrospective study of patients attending an urban scoliosis clinic identified 71 patients satisfying a criteria of: clinical diagnosis of idiopathic scoliosis; age of onset ten years and 11 months or less; MRI screening for intraspinal abnormalities. United Kingdom census data combined with patient referral data was used to calculate incidence.


Bone & Joint Research
Vol. 6, Issue 4 | Pages 194 - 195
1 Apr 2017
Simpson AHRW Howie CR Norrie J


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 229 - 237
1 Feb 2016
Roberts SB Dryden R Tsirikos AI

Aims

Clinical and radiological data were reviewed for all patients with mucopolysaccharidoses (MPS) with thoracolumbar kyphosis managed non-operatively or operatively in our institution.

Methods

In all 16 patients were included (eight female: eight male; 50% male), of whom nine had Hurler, five Morquio and two Hunter syndrome. Six patients were treated non-operatively (mean age at presentation of 6.3 years; 0.4 to 12.9); mean kyphotic progression +1.5o/year; mean follow-up of 3.1 years (1 to 5.1) and ten patients operatively (mean age at presentation of 4.7 years; 0.9 to 14.4); mean kyphotic progression 10.8o/year; mean follow-up of 8.2 years; 4.8 to 11.8) by circumferential arthrodesis with posterior instrumentation in patients with flexible deformities (n = 6).


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1411 - 1416
1 Oct 2015
Li Y Yang S Chen H Kao Y Tu Y

We evaluated the impact of lumbar instrumented circumferential fusion on the development of adjacent level vertebral compression fractures (VCFs). Instrumented posterior lumbar interbody fusion (PLIF) has become a popular procedure for degenerative lumbar spine disease. The immediate rigidity produced by PLIF may cause more stress and lead to greater risk of adjacent VCFs. However, few studies have investigated the relationship between PLIF and the development of subsequent adjacent level VCFs.

Between January 2005 and December 2009, a total of 1936 patients were enrolled. Of these 224 patients had a new VCF and the incidence was statistically analysed with other covariants. In total 150 (11.1%) of 1348 patients developed new VCFs with PLIF, with 108 (72%) cases at adjacent segment. Of 588 patients, 74 (12.5%) developed new subsequent VCFs with conventional posterolateral fusion (PLF), with 37 (50%) patients at an adjacent level. Short-segment fusion, female and age older than 65 years also increased the development of new adjacent VCFs in patients undergoing PLIF. In the osteoporotic patient, more rigid fusion and a higher stress gradient after PLIF will cause a higher adjacent VCF rate.

Cite this article: Bone Joint J 2015;97-B:1411–16.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 23 - 25
1 Aug 2014

The August 2014 Spine Roundup360 looks at: rhBMP complicates cervical spine surgery; posterior longitudinal ligament revisited; thoracolumbar posterior instrumentation without fusion in burst fractures; risk modelling for VTE events in spinal surgery; the consequences of dural tears in microdiscectomy; trends in revision spinal surgery; radiofrequency denervation likely effective in facet joint pain and hooks optimally biomechanically transition posterior instrumentation.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims

We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy.

Materials and Methods

Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers.