We undertook a cemental unipolar proximal
Most injuries to the
Oxidised zirconium (OxZi) has been developed
as an alternative bearing surface for femoral heads in total hip arthroplasty
(THA). This study has investigated polyethylene wear, functional
outcomes and complications, comparing OxZi and cobalt–chrome (CoCr)
as part of a three-arm, multicentre randomised controlled trial.
Patients undergoing THA from four institutions were prospectively
randomised into three groups. Group A received a CoCr
Between April 1992 and November 1998 we used 34 massive proximal
In this meta-analysis we included 32 English-language articles published between January 1975 and June 2004 on the diagnostic performance of plain radiography, subtraction arthrography, nuclear arthrography and bone scintigraphy in detecting aseptic loosening of the
This prospective, longitudinal study documents the muscle strength and baseline function of 18 patients undergoing closed
We describe the clinical and radiological results of 38 total hip replacements (THR) using the JRI Furlong hydroxyapatite-ceramic (HAC)-coated
Vascular injuries after total hip arthroplasty are occasionally reported, but we have found only two cases of major arterial occlusion, and none at all involving the common
The excellent long-term results for the first-generation Charnley stem may not apply to later versions with flanges. It seems possible that the early design functioned as a taper-slip system, as accepted in the Exeter prosthesis. Comparison with the requirements for the alternative composite-beam system for the
We reviewed a consecutive series of 527 uninfected hip replacements in patients resident in the UK which had been implanted from 1981 to 1993. All had the same basic design of
We describe a new method of reconstruction after resection of tumours of the proximal tibia by grafting and arthrodesis of the knee. Two separate vascularised bone grafts from the ipsilateral limb were used, one a gastrocnemius-pedicled
In order to evaluate the relationship between acetabular and proximal
It is accepted that resurfacing hip replacement
preserves the bone mineral density (BMD) of the femur better than total
hip replacement (THR). However, no studies have investigated any
possible difference on the acetabular side. Between April 2007 and March 2009, 39 patients were randomised
into two groups to receive either a resurfacing or a THR and were
followed for two years. One patient’s resurfacing subsequently failed,
leaving 19 patients in each group. Resurfaced replacements maintained proximal
1. The combination of
We have studied aseptic loosening of the
We undertook a review of the literature relating to the two basic stem designs in use in cemented hip replacement, namely loaded tapers or force-closed
Fractures of the
We assessed the outcome of patients with Vancouver type B2 and B3 periprosthetic fractures treated with
We implanted 57 uncemented cobalt-chrome porous-coated collarless
We have designed a modular cemented