The February 2015 Research Roundup360 looks at: Markers of post-traumatic ankle arthritis; Mangoes, trees and Solomon Islanders; Corticosteroid injection and ulnar neuropathy; Moral decision-making: the secret skill?; Biomechanical studies under the spotlight; Anaesthetic risk and hip replacement
The February 2015 Shoulder &
Elbow Roundup360 looks at: Proximal Humerus fractures a comprehensive review, Predicting complications in shoulder ORIF, The Coronoid Revisited, Remplissage and bankart repair for Hill-Sach’s lesions, Diabetes and elbow arthroplasty, Salvage surgery for failed bankart repair, Sternoclavicular Joint Reconstruction, Steroids effective in the short-term for tennis elbow
For over a decade, bisphosphonate administration
has evolved and become the cornerstone of the prevention and treatment
of fragility fractures. Millions of post-menopausal women have relied
on, and continue to depend on, the long-acting, bone density-maintaining
pharmaceutical drug to prevent low-energy fractures. In return,
we have seen the number of fragility fractures decrease, along with
associated costs and emotional benefits. However, with any drug,
there are often concerns with side effects and complications, and
this unique drug class is seeing one such complication in atypical
subtrochanteric femoral fracture, counterproductive to that which
it was designed to prevent. This has created concern over long-term
bisphosphonate administration and its potential link to these atypical
fractures. There is controversial evidence surrounding such a definitive
link, and no protocol for managing these fractures. This review offers the latest information regarding this rare
but increasingly controversial adverse effect and its potential
connection to one of the most successful forms of treatment that
is available for the management of fragility fractures.
The December 2012 Trauma Roundup360 looks at: more is not always better, especially when its chemotherapy; new hope for skeletal metastasis; biopsy tracts; intra-operative imaging of sarcomas; curettage with adjuvant therapy; amputation and distal tibial osteosarcoma; and diaphyseal tibial tumours.
The December 2014 Shoulder &
Elbow Roundup360 looks at: cuff tears and plexus injury; corticosteroids and physiotherapy in SAI; diabetes and elbow arthroplasty; distal biceps tendon repairs; shockwave therapy in frozen shoulder; hydrodilation and steroids for adhesive capsulitis; just what do our patients read?; and what happens to that stable radial head fracture?
The December 2014 Hip &
Pelvis Roundup360 looks at: Sports and total hips; topical tranexamic acid and blood conservation in hip replacement; blind spots and biases in hip research; no recurrence in cam lesions at two years; to drain or not to drain?; sonication and diagnosis of implant associated infection; and biomarkers and periprosthetic infection
We have carried out a prospective double-blind randomised controlled trial to compare the efficacy of a single subacromial injection of the non-steroidal anti-inflammatory drug, tenoxicam, with a single injection of methylprednisolone in patients with subacromial impingement. A total of 58 patients were randomly allocated into two groups. Group A received 40 mg of methylprednisolone and group B 20 mg of tenoxicam as a subacromial injection along with lignocaine. The Constant-Murley shoulder score was used as the primary outcome measure and the Disability of Arm, Shoulder and Hand (DASH) and the Oxford Shoulder Score (OSS) as secondary measures. Six weeks after injection the improvement in the Constant-Murley score was significantly greater in the methylprednisolone group (p = 0.003) than in the tenoxicam group. The improvement in the DASH score was greater in the steroid group and the difference was statistically significant and consistent two (p <
0.01), four (p <
0.01) and six weeks (p <
0.020) after the injection. The improvement in the OSS was consistently greater in the steroid group than in the tenoxicam group. Although the difference was statistically significant at two (p <
0.001) and four (p = 0.003) weeks after the injection, it was not at six weeks (p = 0.055). Subacromial injection of tenoxicam does not offer an equivalent outcome to subacromial injection of corticosteroid at six weeks. Corticosteroid is significantly better than tenoxicam for improving shoulder function in tendonitis of the rotator cuff after six weeks.
The October 2012 Hip &
Pelvis Roundup360 looks at: diagnosing the infected hip replacement; whether tranexamic acid has a low complication rate; the relationship between poor cementing technique and early failure of resurfacing; debridement and retention for the infected replacement; triple-tapered stems and bone mineral density; how early discharge can be bad for your sleep; an updated QFracture algorithm to predict the risk of an osteoporotic fracture; and local infiltration analgesia and total hip replacement.
Cite this article:
The October 2014 Shoulder &
Elbow Roundup360 looks at: PRP is not effective in tennis elbow; eccentric physiotherapy effective in subacromial pain; dexamethasone in shoulder surgery; arthroscopic remplissage for engaging Hill-Sach’s lesions; a consistent approach to subacromial impingement; delay in fixation of proximal humeral fractures detrimental to outcomes.
We explore the limitations of complete reliance
on evidence-based medicine which can be diminished by confounding
issues and sampling bias. Other strategies which may be reasonably
invoked are discussed. Cite this article:
Cite this article:
In a decidedly upper limb themed series of reviews this edition of Cochrane Corner summarises four new and updated reviews published by the Cochrane Bone, Joint and Muscle Trauma Group over the last few months. The tenacious reviewers at the Cochrane collaboration have turned their beady eyes to conservative treatments for shoulder dislocations and clavicle fractures along with evaluation of femoral nerve blocks in knee replacement and how to best manage entrapment injuries in children.
The October 2014 Wrist &
Hand Roundup360 looks at: pulsed electromagnetic field of no use in acute scaphoid fractures; proximal interphalangeal joint replacement: one at a time or both at once; trapeziometacarpal arthrodesis in the young patient; Tamoxifen and Dupytren’s disease; and endoscopic or open for de Quervain’s syndrome?
Total knee replacement (TKR) smart tibial trials
have load-bearing sensors which will show quantitative compartment
pressure values and femoral-tibial tracking patterns. Without smart
trials, surgeons rely on feel and visual estimation of imbalance
to determine if the knee is optimally balanced. Corrective soft-tissue
releases are performed with minimal feedback as to what and how
much should be released. The smart tibial trials demonstrate graphically
where and how much imbalance is present, so that incremental releases
can be performed. The smart tibial trials now also incorporate accelerometers
which demonstrate the axial alignment. This now allows the surgeon
the option to perform a slight recut of the tibia or femur to provide
soft-tissue balance without performing soft-tissue releases. Using
a smart tibial trial to assist with soft-tissue releases or bone
re-cuts, improved patient outcomes have been demonstrated at one
year in a multicentre study of 135 patients (135 knees). Cite this article:
The April 2012 Knee Roundup360 looks at the torn ACL, ACL reconstruction, the risk of ACL rupture, the benefit of warm-ups before exercise, glucosamine and tibiofemoral osteoarthritis, sensitisation and sporting tendinopathy, pain relief after TKR, the long-term results of the Genesis I, the gender specific recovery times after TKR, and the accuracy of the orthopaedic eyeball
The April 2012 Shoulder &
Elbow Roundup360 looks at katakori in Japan, frozen shoulder, if shoulder impingement actually exists, shoulder arthroscopy and suprascapular nerve blocks, why shoulder replacements fail, the infected elbow replacement, the four-part fracture, the acromion index, and arm transplantation
There are many types of treatment used to manage the frozen shoulder, but there is no consensus on how best to manage patients with this painful and debilitating condition. We conducted a review of the evidence of the effectiveness of interventions used to manage primary frozen shoulder using the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects, the Physiotherapy Evidence Database, MEDLINE and EMBASE without language or date restrictions up to April 2009. Two authors independently applied selection criteria and assessed the quality of systematic reviews using the Assessment of Multiple Systematic Reviews (AMSTAR) tool. Data were synthesised narratively, with emphasis placed on assessing the quality of evidence. In total, 758 titles and abstracts were identified and screened, which resulted in the inclusion of 11 systematic reviews. Although these met most of the AMSTAR quality criteria, there was insufficient evidence to draw firm conclusions about the effectiveness of treatments commonly used to manage a frozen shoulder. This was mostly due to poor methodological quality and small sample size in primary studies included in the reviews. We found no reviews evaluating surgical interventions. More rigorous randomised trials are needed to evaluate the treatments used for frozen shoulder.
We performed a systematic review and meta-analysis
to compare the efficacy of intermittent mechanical compression combined
with pharmacological thromboprophylaxis, against either mechanical
compression or pharmacological prophylaxis in preventing deep-vein
thrombosis (DVT) and pulmonary embolism in patients undergoing hip
or knee replacement. A total of six randomised controlled trials,
evaluating a total of 1399 patients, were identified. In knee arthroplasty,
the rate of DVT was reduced from 18.7% with anticoagulation alone
to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03;
number needed to treat: seven). There was moderate, albeit non-significant,
heterogeneity (I2 = 42%). In hip replacement, there was
a non-significant reduction in DVT from 8.7% with mechanical compression
alone to 7.2% with additional pharmacological prophylaxis (RR 0.84)
and a significant reduction in DVT from 9.7% with anticoagulation
alone to 0.9% with additional mechanical compression (RR 0.17, p
<
0.001; number needed to treat: 12), with no heterogeneity (I2 =
0%). The included studies had insufficient power to demonstrate
an effect on pulmonary embolism. We conclude that the addition of intermittent mechanical leg
compression augments the efficacy of anticoagulation in preventing
DVT in patients undergoing both knee and hip replacement. Further
research on the role of combined modalities in thromboprophylaxis
in joint replacement and in other high-risk situations, such as fracture
of the hip, is warranted.