We analysed whether a high body mass index (BMI)
had a deleterious effect on outcome following autologous chondrocyte
implantation (ACI) or matrix-carried autologous chondrocyte implantation
(MACI) for the treatment of full-thickness chondral defects of the
knee from a subset of patients enrolled in the ACI vs MACI trial
at The Royal National Orthopaedic Hospital. The mean Modified Cincinnati scores (MCS) were significantly
higher (p <
0.001) post-operatively in patients who had an ideal
body weight (n = 53; 20 to 24.9 kg/m2) than in overweight
(n = 63; 25 to 30 kg/m2) and obese patients (n = 22;
>
30 kg/m2). At a follow-up of two years, obese patients
demonstrated no sustained improvement in the MCS. Patients with
an ideal weight experienced significant improvements as early as
six months after surgery (p = 0.007). In total, 82% of patients
(31 of 38) in the ideal group had a good or excellent result, compared
with 49% (22 of 45) of the overweight and 5.5% (one of 18) in the
obese group (p <
0.001). There was a significant negative relationship between
BMI and the MCS 24 months after surgery (r = -0.4, p = 0.001). This study demonstrates that obese patients have worse knee function
before surgery and experience no sustained benefit from ACI or MACI
at two years after surgery. There was a correlation between increasing
BMI and a lower MCS according to a linear regression analysis. On
the basis of our findings patient selection can be more appropriately
targeted.
The Oxford mobile-bearing unicompartmental knee
replacement (UKR) is an effective and safe treatment for osteoarthritis
of the medial compartment. The results in the lateral compartment
have been disappointing due to a high early rate of dislocation
of the bearing. A series using a newly designed domed tibial component
is reported. The first 50 consecutive domed lateral Oxford UKRs in 50 patients
with a mean follow-up of three years (2.0 to 4.3) were included.
Clinical scores were obtained prospectively and Kaplan-Meier survival
analysis was performed for different endpoints. Radiological variables
related to the position and alignment of the components were measured. One patient died and none was lost to follow-up. The cumulative
incidence of dislocation was 6.2% (95% confidence interval (CI)
2.0 to 17.9) at three years. Survival using revision for any reason
and aseptic revision was 94% (95% CI 82 to 98) and 96% (95% CI 85
to 99) at three years, respectively. Outcome scores, visual analogue
scale for pain and maximum knee flexion showed a significant improvement
(p <
0.001). The mean Oxford knee score was 43 ( Clinical results are excellent and short-term survival has improved
when compared with earlier series. The risk of dislocation remains
higher using a mobile-bearing UKR in the lateral compartment when
compared with the medial compartment. Patients should be informed
about this complication. To avoid dislocations, care must be taken
not to elevate the lateral joint line.
We present a series of 35 patients (19 men and
16 women) with a mean age of 64 years (36.7 to 75.9), who underwent
total hip replacement using the ESKA dual-modular short stem with
metal on-polyethylene bearing surfaces. This implant has a modular
neck section in addition to the modular head. Of these patients,
three presented with increasing post-operative pain due to pseudotumour
formation that resulted from corrosion at the modular neck-stem
junction. These patients underwent further surgery and aseptic lymphocytic
vaculitis associated lesions were demonstrated on histological analysis. Retrieval analysis of two modular necks showed corrosion at the
neck-stem taper. Blood cobalt and chromium levels were measured
at a mean of nine months (3 to 28) following surgery. These were
compared with the levels in seven control patients (three men and
four women) with a mean age of 53.4 years (32.1 to 64.1), who had
an identical prosthesis and articulation but with a prosthesis that
had no modularity at neck-stem junction. The mean blood levels of
cobalt in the study group were raised at 50.75 nmol/l (5 to 145)
compared with 5.6 nmol/l (2 to 13) in control patients. Corrosion at neck-stem tapers has been identified as an important
source of metal ion release and pseudotumour formation requiring
revision surgery. Finite element modelling of the dual modular stem
demonstrated high stresses at the modular stem-neck junction. Dual
modular cobalt-chrome hip prostheses should be used with caution
due to these concerns.
We prospectively followed 191 consecutive collarless
polished tapered (CPT) femoral stems, implanted in 175 patients
who had a mean age at operation of 64.5 years (21 to 85). At a mean
follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were
still alive. The fate of all original stems is known. The 16-year
survivorship with re-operation for any reason was 80.7% (95% confidence
interval 72 to 89.4). There was no loss to follow-up, with clinical
data available on all 95 hips and radiological assessment performed
on 90 hips (95%). At latest follow-up, the mean Harris hip score
was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48).
Stems subsided within the cement mantle, with a mean subsidence
of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem
(0.5%) has been revised due to aseptic loosening. In total seven
stems were revised for any cause, of which four revisions were required
for infection following revision of the acetabular component. A
total of 21 patients (11%) required some sort of revision procedure;
all except three of these resulted from failure of the acetabular
component. Cemented acetabular components had a significantly lower
revision burden (three hips, 2.7%) than Harris Galante uncemented
components (17 hips, 21.8%) (p <
0.001). The CPT stem continues to provide excellent radiological and
clinical outcomes at 15 years following implantation. Its results
are consistent with other polished tapered stem designs.
We aimed first to summarise minimal clinically important differences
(MCIDs) after total hip (THR) or knee replacement (TKR) in health-related
quality of life (HRQoL), measured using the Short-Form 36 (SF-36).
Secondly, we aimed to improve the precision of MCID estimates by
means of meta-analysis. We conducted a systematic review of English and non-English articles
using MEDLINE, the Cochrane Controlled Trials Register (1960–2011),
EMBASE (1991–2011), Web of Science, Academic Search Premier and
Science Direct. Bibliographies of included studies were searched
in order to find additional studies. Search terms included MCID
or minimal clinically important change, THR or TKR and Short-Form
36. We included longitudinal studies that estimated MCID of SF-36
after THR or TKR.Objectives
Methods
A total of 12 epileptic patients (14 shoulders)
with recurrent seizures and anterior dislocations of the shoulder underwent
a Latarjet procedure and were reviewed at a mean of 8.3 years (1
to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°)
to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°)
to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to
100) at the final follow-up. Radiologically, all shoulders showed
a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes
of the glenohumeral joint were observed in five shoulders (36%)
pre-operatively and in eight shoulders (57%) post-operatively.
Re-dislocation during a seizure occurred in six shoulders (43%).
Five of these patients underwent revision surgery using a bone buttress
from the iliac crest and two of these patients re-dislocated due
to a new seizure. Due to the unacceptably high rate of re-dislocation after surgery
in these patients, the most important means of reducing the incidence
of further dislocation is the medical management of the seizures.
The Latarjet procedure should be reserved for the well-controlled
patient with epilepsy who has recurrent anterior dislocation of
the shoulder during activities of daily living.
We present the extended follow-up (≥ 20 years)
of a series of fully hydroxyapatite-coated femoral components used in
72 primary total hip replacements (THRs). Earlier results of this
cohort have been previously published. All procedures were performed
between 1986 and 1991. The series involved 45 women and 15 men with
12 bilateral procedures. Their mean age at the time of surgery was
60 years (46 to 80) and the mean duration of follow-up was 22.5
years (20 to 25). At final follow-up, the mean Merle d’Aubigné and
Postel hip scores were 5.5 (4.5 to 6), 3.8 (3.5 to 5) and 3.3 (3.0
to 5.0) for pain, mobility and function, respectively. Of the patients
92% were very satisfied at the time of final follow-up. There were seven revisions: six of the acetabular component for
aseptic loosening and one of both the stem and the acetabular component
for loosening due to deep infection. The survival of this prosthesis
at 22.5 years with revision for any reason as the endpoint was 91.7%
(95% confidence interval (CI) 84 to 99). Survival with aseptic loosening
of the stem as the endpoint was 100% (95% CI 90 to 100). This prosthesis provides pain relief in the long term. Survival
of this component is comparable to the best results for primary
THR with any means of fixation. Cite this article:
The April 2013 Foot &
Ankle Roundup360 looks at: whether arthroscopic arthrodesis is advantageous; osteochondral autografts; suture button associated fractures; an ultrasound solution to Achilles tendinopathy; the safety of the tendo Achilles in men; charcot and antibiotic-coated nails; and botox and Policeman’s Heel.
The Oxford unicompartmental knee replacement
(UKR) is an established treatment option in the management of symptomatic
end-stage medial compartmental osteoarthritis (MCOA), which works
well in the young and active patient. However, previous studies
have shown that it is reliable only in the presence of a functionally
intact anterior cruciate ligament (ACL). This review reports the
outcomes, at a mean of five years and a maximum of ten years, of 52
consecutive patients with a mean age of 51 years (36 to 57) who
underwent staged or simultaneous ACL reconstruction and Oxford UKR.
At the last follow-up (with one patient lost to follow-up), the
mean Oxford knee score was 41 ( In summary, ACL reconstruction and Oxford UKR gives good results
in patients with end-stage MCOA secondary to ACL deficiency.
There is little information about the management
of peri-prosthetic fracture of the humerus after total shoulder replacement
(TSR). This is a retrospective review of 22 patients who underwent
a revision of their original shoulder replacement for peri-prosthetic
fracture of the humerus with bone loss and/or loose components.
There were 20 women and two men with a mean age of 75 years (61
to 90) and a mean follow-up 42 months (12 to 91): 16 of these had
undergone a previous revision TSR. Of the 22 patients, 12 were treated
with a long-stemmed humeral component that bypassed the fracture.
All their fractures united after a mean of 27 weeks (13 to 94).
Eight patients underwent resection of the proximal humerus with
endoprosthetic replacement to the level of the fracture. Two patients
were managed with a clam-shell prosthesis that retained the original
components. The mean Oxford shoulder score (OSS) of the original
TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean
OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival
using re-intervention for any reason as the endpoint was 91% (95%
confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at
one and five years, respectively. There were two revisions for dislocation of the humeral head,
one open reduction for modular humeral component dissociation, one
internal fixation for nonunion, one trimming of a prominent screw
and one re-cementation for aseptic loosening complicated by infection,
ultimately requiring excision arthroplasty. Two patients sustained
nerve palsies. Revision TSR after a peri-prosthetic humeral fracture associated
with bone loss and/or loose components is a salvage procedure that
can provide a stable platform for elbow and hand function. Good
rates of union can be achieved using a stem that bypasses the fracture.
There is a high rate of complications and function is not as good as
with the original replacement.
Autologous retransfusion and no-drainage are
both blood-saving measures in total hip replacement (THR). A new combined
intra- and post-operative autotransfusion filter system has been
developed especially for primary THR, and we conducted a randomised
controlled blinded study comparing this with no-drainage. A total of 204 THR patients were randomised to autologous blood
transfusion (ABT)
(n = 102) or no-drainage (n = 102). In the ABT group, a mean of
488 ml ( The use of a new intra- and post-operative autologous blood transfusion
filter system results in less total blood loss and a smaller maximum
decrease in haemoglobin levels than no-drainage following primary
THR. Cite this article:
In a randomised controlled pragmatic trial we
investigated whether local infiltration analgesia would result in earlier
readiness for discharge from hospital after total knee replacement
(TKR) than patient-controlled epidural analgesia (PCEA) plus femoral
nerve block. A total of 45 patients with a mean age of 65 years
(49 to 81) received a local infiltration with a peri-articular injection
of bupivacaine, morphine and methylprednisolone, as well as adjuvant
analgesics. In 45 PCEA+femoral nerve blockade patients with a mean
age of 67 years (50 to 84), analgesia included a bupivacaine nerve
block, bupivacaine/hydromorphone PCEA, and adjuvant analgesics.
The mean time until ready for discharge was 3.2 days (1 to 14) in
the local infiltration group and 3.2 days (1.8 to 7.0) in the PCEA+femoral
nerve blockade group. The mean pain scores for patients receiving
local infiltration were higher when walking (p = 0.0084), but there
were no statistically significant differences at rest. The mean
opioid consumption was higher in those receiving local infiltration. The choice between these two analgesic pathways should not be
made on the basis of time to discharge after surgery. Most secondary
outcomes were similar, but PCEA+femoral nerve blockade patients
had lower pain scores when walking and during continuous passive
movement. If PCEA+femoral nerve blockade is not readily available, local
infiltration provides similar length of stay and similar pain scores
at rest following TKR. Cite this article:
Following arthroplasty of the knee, the patient’s
perception of improvement in symptoms is fundamental to the assessment
of outcome. Better clinical outcome may offset the inferior survival
observed for some types of implant. By examining linked National
Joint Registry (NJR) and patient-reported outcome measures (PROMs)
data, we aimed to compare PROMs collected at a minimum of six months
post-operatively for total (TKR: n = 23 393) and unicondylar knee
replacements (UKR: n = 505). Improvements in knee-specific (Oxford
knee score, OKS) and generic (EuroQol, EQ-5D) scores were compared
and adjusted for case-mix differences using multiple regression.
Whereas the improvements in the OKS and EQ-5D were significantly
greater for TKR than for UKR, once adjustments were made for case-mix
differences and pre-operative score, the improvements in the two
scores were not significantly different. The adjusted mean differences
in the improvement of OKS and EQ-5D were 0.0 (95% confidence interval (CI)
-0.9 to 0.9; p = 0.96) and 0.009 (95% CI -0.034 to 0.015; p = 0.37),
respectively. We found no difference in the improvement of either knee-specific
or general health outcomes between TKR and UKR in a large cohort
of registry patients. With concerns about significantly higher revision
rates for UKR observed in worldwide registries, we question the
widespread use of an arthroplasty that does not confer a significant
benefit in clinical outcome.
Slipped capital femoral epiphysis (SCFE) is relatively
common in adolescents and results in a complex deformity of the
hip that can lead to femoroacetabular impingement (FAI). FAI may
be symptomatic and lead to the premature development of osteoarthritis
(OA) of the hip. Current techniques for managing the deformity include
arthroscopic femoral neck osteochondroplasty, an arthroscopically
assisted limited anterior approach to the hip, surgical dislocation,
and proximal femoral osteotomy. Although not a routine procedure
to treat FAI secondary to SCFE deformity, peri-acetabular osteotomy
has been successfully used to treat FAI caused by acetabular over-coverage. These
procedures should be considered for patients with symptoms due to
a deformity of the hip secondary to SCFE. Cite this article:
We systematically reviewed all the evidence published
in the English language on proximal interphalangeal joint (PIPJ)
replacement, to determine its effectiveness on the function of the
hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome
with a minimum of one year’s follow-up. Quality was assessed using
the Cowley systematic review criteria modified for finger-joint
replacements. Of 319 articles identified, only five were adequately
reported according to our quality criteria; there were no randomised
controlled trials. PIPJ replacements had a substantial effect size
on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1)
and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect
on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach
was most successful. Post-operative loosening occurred in 10% (95%
CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon
replacements. Post-operative complications occurred in 27.8% (95%
CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not
been established. Small observational case studies and short-term
follow-up, together with insufficient reporting of patient data,
functional outcomes and complications, limit the value of current
evidence. We recommend that a defined core set of patients, surgical and
outcome data for this intervention be routinely and systematically
collected within the framework of a joint registry.
Component malalignment can be associated with
pain following total knee replacement (TKR). Using MRI, we reviewed
50 patients with painful TKRs and compared them with a group of
16 asymptomatic controls to determine the feasibility of using MRI
in evaluating the rotational alignment of the components. Using
the additional soft-tissue detail provided by this modality, we
also evaluated the extent of synovitis within these two groups.
Angular measurements were based on the femoral transepicondylar
axis and tibial tubercle. Between two observers, there was very
high interobserver agreement in the measurements of all values.
Patients with painful TKRs demonstrated statistically significant
relative internal rotation of the femoral component (p = 0.030).
There was relative internal rotation of the tibial to femoral component
and combined excessive internal rotation of the components in symptomatic
knees, although these results were significant only with one of
the observers (p = 0.031). There was a statistically significant
association between the presence and severity of synovitis and painful
TKR (p <
0.001). MRI is an effective modality in evaluating component rotational
alignment.
We evaluated the rates of survival and cause
of revision of seven different brands of cemented primary total
knee replacement (TKR) in the Norwegian Arthroplasty Register during
the years 1994 to 2009. Revision for any cause, including resurfacing
of the patella, was the primary endpoint. Specific causes of revision
were secondary outcomes. Three posterior cruciate-retaining (PCR) fixed modular-bearing
TKRs, two fixed non-modular bearing PCR TKRs and two mobile-bearing
posterior cruciate-sacrificing TKRs were investigated in a total
of 17 782 primary TKRs. The median follow-up for the implants ranged
from 1.8 to 6.9 years. Kaplan-Meier 10-year survival ranged from
89.5% to 95.3%. Cox’s relative risk (RR) was calculated relative
to the fixed modular-bearing Profix knee (the most frequently used
TKR in Norway), and ranged from 1.1 to 2.6. The risk of revision
for aseptic tibial loosening was higher in the mobile-bearing LCS
Classic (RR 6.8 (95% confidence interval (CI) 3.8 to 12.1)), the
LCS Complete (RR 7.7 (95% CI 4.1 to 14.4)), the fixed modular-bearing
Duracon (RR 4.5 (95% CI 1.8 to 11.1)) and the fixed non-modular
bearing AGC Universal TKR (RR 2.5 (95% CI 1.3 to 5.1)), compared
with the Profix. These implants (except AGC Universal) also had
an increased risk of revision for femoral loosening (RR 2.3
(95% CI 1.1 to 4.8), RR 3.7 (95% CI 1.6 to 8.9), and RR 3.4 (95%
CI 1.1 to 11.0), respectively). These results suggest that aseptic
loosening is related to design in TKR. Cite this article:
There have been only a few small studies of patients
with an infected shoulder replacement treated with a single-stage
exchange procedure. We retrospectively reviewed 35 patients (19 men
and 16 women) with a peri-prosthetic infection of the shoulder who
were treated in this way. A total of 26 were available for clinical
examination; three had died, two were lost to follow-up and four
patients had undergone revision surgery. The mean follow-up time was
4.7 years (1.1 to 13.25), with an infection-free survival of 94%. The organisms most commonly isolated intra-operatively were Single-stage exchange is a successful and practical treatment
for patients with peri-prosthetic infection of the shoulder. Cite this article:
The August 2012 Research Roundup360 looks at: PRP and chondrogenic differentiation; basic fibroblast growth factor; whether glucosamine works; randomised trials; ossification of the ligamentum flavum; treadmill running; inhibiting BMP antagonists; and whether NSAIDs delay union after all.
Despite many claims of good wear properties following
total knee replacement (TKR) with an oxidised zirconium (OxZr) femoral
component, there are conflicting clinical results. We hypothesised
that there would be no difference in either the mid-term clinical
and radiological outcomes or the characteristics of the polyethylene
wear particles (weight, size and shape) in patients using an OxZr
or cobalt-chrome (CoCr) femoral component. In all 331 patients underwent
bilateral TKR, receiving an OxZr femoral component in one knee and
a CoCr femoral component in the other. The mean follow-up was 7.5
years (6 to 8). Following aspiration, polyethylene wear particles
were analysed using thermogravimetric methods and scanning electron
microscopy. At the most recent follow-up, the mean Knee Society
score, Western Ontario and McMaster Universities Osteoarthritis
Index score, range of movement and satisfaction score were not significantly
different in the two groups. The mean weight, size, aspect ratio
and roundness of the aspirated wear particles were similar for each
femoral component. Survivorship of the femoral, tibial and patellar
components was 100% in both groups. In the absence of evidence of an advantage in the medium term
we cannot justify the additional expense of an OxZr femoral component.