Advertisement for orthosearch.org.uk
Results 221 - 240 of 549
Results per page:
Bone & Joint 360
Vol. 8, Issue 2 | Pages 33 - 35
1 Apr 2019


Bone & Joint 360
Vol. 8, Issue 3 | Pages 31 - 33
1 Jun 2019


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 506 - 512
1 Apr 2020
de Bodman C Ansorge A Tabard A Amirghasemi N Dayer R

Aims

The direct posterior approach with subperiosteal dissection of the paraspinal muscles from the vertebrae is considered to be the standard approach for the surgical treatment of adolescent idiopathic scoliosis (AIS). We investigated whether or not a minimally-invasive surgery (MIS) technique could offer improved results.

Methods

Consecutive AIS patients treated with an MIS technique at two tertiary centres from June 2013 to March 2016 were retrospectively included. Preoperative patient deformity characteristics, perioperative parameters, power of deformity correction, and complications were studied. A total of 93 patients were included. The outcome of the first 25 patients and the latter 68 were compared as part of our safety analysis to examine the effect of the learning curve.


Bone & Joint 360
Vol. 9, Issue 1 | Pages 51 - 52
1 Feb 2020
Das A


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 371 - 375
1 Mar 2020
Cawley D Dhokia R Sales J Darwish N Molloy S

With the identification of literature shortfalls on the techniques employed in intraoperative navigated (ION) spinal surgery, we outline a number of measures which have been synthesised into a coherent operative technique. These include positioning, dissection, management of the reference frame, the grip, the angle of attack, the drill, the template, the pedicle screw, the wire, and navigated intrathecal analgesia. Optimizing techniques to improve accuracy allow an overall reduction of the repetition of the surgical steps with its associated productivity benefits including time, cost, radiation, and safety.

Cite this article: Bone Joint J 2020;102-B(3):371–375.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 414 - 422
1 Apr 2020
Gwynne-Jones DP Gray AR

Aims

To compare long-term survival of all-cemented and hybrid total hip arthroplasty (THA) using the Exeter Universal stem.

Methods

Details of 1,086 THAs performed between 1999 and 2005 using the Exeter stem and either a cemented (632) or uncemented acetabular component (454) were collected from local records and the New Zealand Joint Registry. A competing risks regression survival analysis was performed with death as the competing risk with adjustments made for age, sex, approach, and bearing.


Bone & Joint 360
Vol. 9, Issue 1 | Pages 25 - 28
1 Feb 2020


Bone & Joint 360
Vol. 9, Issue 1 | Pages 32 - 35
1 Feb 2020


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 220 - 226
1 Feb 2020
Clough TM Ring J

Aims

Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR.

Methods

We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 708 - 714
1 Jun 2019
Metcalfe D Costa ML Parsons NR Achten J Masters J Png ME Lamb SE Griffin XL

Aims

This study sought to determine the proportion of older adults with hip fractures captured by a multicentre prospective cohort, the World Hip Trauma Evaluation (WHiTE), whether there was evidence of selection bias during WHiTE recruitment, and the extent to which the WHiTE cohort is representative of the broader population of older adults with hip fractures.

Patients and Methods

The characteristics of patients recruited into the WHiTE cohort study were compared with those treated at WHiTE hospitals during the same timeframe and submitted to the National Hip Fracture Database (NHFD).


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1160 - 1167
1 Sep 2019
Wang WT Li YQ Guo YM Li M Mei HB Shao JF Xiong Z Li J Canavese F Chen SY

Aims

The aim of this study was to clarify the factors that predict the development of avascular necrosis (AVN) of the femoral head in children with a fracture of the femoral neck.

Patients and Methods

We retrospectively reviewed 239 children with a mean age of 10.0 years (sd 3.9) who underwent surgical treatment for a femoral neck fracture. Risk factors were recorded, including age, sex, laterality, mechanism of injury, initial displacement, the type of fracture, the time to reduction, and the method and quality of reduction. AVN of the femoral head was assessed on radiographs. Logistic regression analysis was used to evaluate the independent risk factors for AVN. Chi-squared tests and Student’s t-tests were used for subgroup analyses to determine the risk factors for AVN.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1292 - 1299
1 Oct 2019
Masters J Metcalfe D Parsons NR Achten J Griffin XL Costa ML

Aims

This study explores data quality in operation type and fracture classification recorded as part of a large research study and a national audit with an independent review.

Patients and Methods

At 17 centres, an expert surgeon reviewed a randomly selected subset of cases from their centre with regard to fracture classification using the AO system and type of operation performed. Agreement for these variables was then compared with the data collected during conduct of the World Hip Trauma Evaluation (WHiTE) cohort study. Both types of surgery and fracture classification were collapsed to identify the level of detail of reporting that achieved meaningful agreement. In the National Hip Fracture Database (NHFD), the types of operation and fracture classification were explored to identify the proportion of “highly improbable” combinations.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 212 - 219
1 Feb 2020
Ræder BW Figved W Madsen JE Frihagen F Jacobsen SB Andersen MR

Aims

In a randomized controlled trial with two-year follow-up, patients treated with suture button (SB) for acute syndesmotic injury had better outcomes than patients treated with syndesmotic screw (SS). The aim of this study was to compare clinical and radiological outcomes for these treatment groups after five years.

Methods

A total of 97 patients with acute syndesmotic injury were randomized to SS or SB. The five-year follow-up rate was 81 patients (84%). The primary outcome was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale. Secondary outcome measures included Olerud-Molander Ankle (OMA) score, visual analogue scale (VAS), EuroQol five-dimension questionnaire (EQ-5D), range of movement, complications, reoperations, and radiological results. CT scans of both ankles were obtained after surgery, and after one, two, and five years.


Bone & Joint 360
Vol. 8, Issue 6 | Pages 36 - 39
1 Dec 2019


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1321 - 1324
1 Nov 2019
Kerr S Warwick D Haddad FS


Bone & Joint 360
Vol. 8, Issue 3 | Pages 29 - 31
1 Jun 2019


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 57 - 61
1 Jun 2019
Chalmers BP Mangold DG Hanssen AD Pagnano MW Trousdale RT Abdel MP

Aims

Modular dual-mobility constructs reduce the risk of dislocation after revision total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chromium (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the early- to mid-term serum Co and Cr levels after modular dual-mobility components were used in revision and complex primary THAs, and specifically included patients revised for ALTR.

Patients and Methods

Serum Co and Cr levels were measured prospectively in 24 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. The mean age was 63 years (35 to 83), with 13 patients (54%) being female. The mean follow-up was four years (2 to 7). Indications for modular dual-mobility were prosthetic joint infection treated with two-stage exchange and subsequent reimplantation (n = 8), ALTR revision (n = 7), complex primary THA (n = 7), recurrent instability (n = 1), and periprosthetic femoral fracture (n = 1). The mean preoperative Co and Cr in patients revised for an ALTR were 29.7 μg/l (2 to 146) and 21.5 μg/l (1 to 113), respectively.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 33 - 37
1 Apr 2020


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 596 - 602
1 May 2019
El-Hawary A Kandil YR Ahmed M Elgeidi A El-Mowafi H

Aims

We hypothesized that there is no difference in the clinical and radiological outcomes using local bone graft versus iliac graft for subtalar distraction arthrodesis in patients with calcaneal malunion. In addition, using local bone graft negates the donor site morbidity.

Patients and Methods

We prospectively studied 28 calcaneal malunion patients (the study group) who were managed by subtalar distraction arthrodesis using local calcaneal bone graft. The study group included 16 male and 12 female patients. The median age was 37.5 years (interquartile range (IQR) 29 to 43). The outcome of the study group was compared with a control group of ten patients previously managed by subtalar distraction arthrodesis using iliac bone graft. The control group included six male and four female patients. The median age was 41.5 years (IQR 36 to 44).


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1175 - 1181
1 Sep 2018
Benca E Willegger M Wenzel F Hirtler L Zandieh S Windhager R Schuh R

Aims

The traditional transosseus flexor hallucis longus (FHL) tendon transfer for patients with Achilles tendinopathy requires two incisions to harvest a long tendon graft. The use of a bio-tenodesis screw enables a short graft to be used and is less invasive, but lacks supporting evidence about its biomechanical behaviour. We aimed, in this study, to compare the strength of the traditional transosseus tendon-to-tendon fixation with tendon-to-bone fixation using a tenodesis screw, in cyclical loading and ultimate load testing.

Materials and Methods

Tendon grafts were undertaken in 24 paired lower-leg specimens and randomly assigned in two groups using fixation with a transosseus suture (suture group) or a tenodesis screw (screw group). The biomechanical behaviour was evaluated using cyclical and ultimate loading tests. The Student’s t-test was performed to assess statistically significant differences in bone mineral density (BMD), displacement, the slope of the load-displacement curves, and load to failure.