Over a five-year period, adult patients with
marginal impaction of acetabular fractures were identified from
a registry of patients who underwent acetabular reconstruction in
two tertiary referral centres. Fractures were classified according
to the system of Judet and Letournel. A topographic classification
to describe the extent of articular impaction was used, dividing
the joint surface into superior, middle and inferior thirds. Demographic information,
hospitalisation and surgery-related complications, functional (EuroQol
5-D) and
We reviewed 32 children after the treatment of simple bone cysts by intralesional injections of methyl-prednisolone acetate. The age of the child and the activity and size of the cyst did not significantly affect the
Aims. This retrospective cohort study compared the results of vascularised
and non-vascularised anterior sliding tibial grafts for the treatment
of osteoarthritis (OA)of the ankle secondary to osteonecrosis of
the talus. . Patients and Methods. We reviewed the clinical and
The aim of this retrospective study was to determine if there are differences in short-term clinical outcomes among four different types of matrix-associated autologous chondrocyte transplantation (MACT). A total of 88 patients (mean age 34 years (SD 10.03), mean BMI 25 kg/m2 (SD 3.51)) with full-thickness chondral lesions of the tibiofemoral joint who underwent MACT were included in this study. Clinical examinations were performed preoperatively and 24 months after transplantation. Clinical outcomes were evaluated using the International Knee Documentation Committee (IKDC) Subjective Knee Form, the Brittberg score, the Tegner Activity Scale, and the visual analogue scale (VAS) for pain. The Kruskal-Wallis test by ranks was used to compare the clinical scores of the different transplant types.Aims
Methods
Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear, radiolucent lines, and osteolysis.Aims
Methods
The main advantage of 3D-printed, off-the-shelf acetabular implants is the potential to promote enhanced bony fixation due to their controllable porous structure. In this study we investigated the extent of osseointegration in retrieved 3D-printed acetabular implants. We compared two groups, one made via 3D-printing (n = 7) and the other using conventional techniques (n = 7). We collected implant details, type of surgery and removal technique, patient demographics, and clinical history. Bone integration was assessed by macroscopic visual analysis, followed by sectioning to allow undecalcified histology on eight sections (~200 µm) for each implant. The outcome measures considered were area of bone attachment (%), extent of bone ingrowth (%), bone-implant contact (%), and depth of ingrowth (%), and these were quantified using a line-intercept method.Aims
Methods
This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported. This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors’ institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed.Aims
Methods
Aims. The Advance Medial-Pivot total knee arthroplasty (TKA) was designed
to reflect contemporary data regarding the kinematics of the knee.
We wished to examine the long-term results obtained with this prosthesis
by extending a previous evaluation. Patients and Methods. We retrospectively evaluated prospectively collected data from
225 consecutive patients (41 men and 184 women; mean age at surgery
71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up
of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both
subjective and objective) and
The most important complication of treatment of developmental dysplasia of the hip (DDH) is avascular necrosis (AVN) of the femoral head, which can result in proximal femoral growth disturbances leading to pain, dysfunction, and eventually to early onset osteoarthritis. In this study, we aimed to identify morphological variants in hip joint development that are predictive of a poor outcome. We retrospectively reviewed all patients who developed AVN after DDH treatment, either by closed and/or open reduction, at a single institution between 1984 and 2007 with a minimal follow-up of eight years. Standard pelvis radiographs obtained at ages one, two, three, five, and eight years, and at latest follow-up were retrieved. The Bucholz-Ogden classification was used to determine the type of AVN on all radiographs. Poor outcome was defined by Severin classification grade 3 or above on the latest follow-up radiographs and/or the need for secondary surgery. With statistical shape modelling, we identified the different shape variants of the hip at each age. Logistic regression analysis was used to associate the different modes or shape variants with poor outcome.Aims
Methods
The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted.Aims
Methods
We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2 periprosthetic femoral fractures (PFFs) treated with internal fixation with that of B1 PFFs treated with internal fixation and B2 fractures treated with revision arthroplasty. We retrospectively reviewed the data of 112 PFFs, of which 47 (42%) B1 and 27 (24%) B2 PFFs were treated with internal fixation, whereas 38 (34%) B2 fractures underwent revision arthroplasty. Decision to perform internal fixation for B2 PFFs was based on specific radiological (polished femoral components, intact bone-cement interface) and clinical criteria (low-demand patient). Median follow-up was 36.4 months (24 to 60). Implant survival and mortality over time were estimated with the Kaplan-Meier method. Adverse events (measured with a modified Dindo-Clavien classification) and 90-day readmissions were additionally compared between groups.Aims
Methods
The increasing prevalence of osteoporosis in
an ageing population has contributed to older patients becoming
the fastest-growing group presenting with acetabular fractures.
We performed a systematic review of the literature involving a number
of databases to identify studies that included the treatment outcome
of acetabular fractures in patients aged >
55 years. An initial
search identified 61 studies; after exclusion by two independent
reviewers, 15 studies were considered to meet the inclusion criteria.
All were case series. The mean Coleman score for methodological
quality assessment was 37 (25 to 49). There were 415 fractures in
414 patients. Pooled analysis revealed a mean age of 71.8 years
(55 to 96) and a mean follow-up of 47.3 months (1 to 210). In seven
studies the results of open reduction and internal fixation (ORIF)
were presented: this was combined with simultaneous hip replacement
(THR) in four, and one study had a mixture of these strategies.
The results of percutaneous fixation were presented in two studies,
and a single study revealed the results of non-operative treatment. With fixation of the fracture, the overall mean rate of conversion
to THR was 23.1% (0% to 45.5%). The mean rate of non-fatal complications
was 39.8% (0% to 64%), and the mean mortality rate was 19.1% (5%
to 50%) at a mean of 64 months (95% confidence interval 59.4 to
68.6; range 12 to 143). Further data dealing with the classification
of the fracture, the surgical approach used, operative time, blood
loss, functional and
We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year.Aims
Methods
Cementless total knee arthroplasty (TKA) offers the potential for strong biological fixation compared with cemented TKA where fixation is achieved by the mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs, which have used additive manufacturing (3D printing). The aim of this study was to present mid-term clinical outcomes and implant survivorship of the cementless Stryker Triathlon Tritanium TKA. This was a single institution registry review of prospectively gathered data from 341 cementless Triathlon Tritanium TKAs at four to 6.8 years follow-up. Outcomes were determined by comparing pre- and postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) scores, and pre- and postoperative 12-item Veterans RAND/Short Form Health Survey (VR/SF-12) scores. Aseptic loosening and revision for any reason were the endpoints which were used to determine survivorship at five years.Aims
Methods
After open reduction for developmental dysplasia of the hip (DDH), a pelvic or femoral osteotomy may be required to maintain a stable concentric reduction. We report the clinical and