Sciatic nerve palsy following total hip arthroplasty
(THA) is a relatively rare yet potentially devastating complication.
The purpose of this case series was to report the results of patients
with a sciatic nerve palsy who presented between 2000 and 2010,
following primary and revision THA and were treated with neurolysis.
A retrospective review was made of 12 patients (eight women and
four men), with sciatic nerve palsy following THA. The mean age
of the patients was 62.7 years (50 to 72; standard deviation 6.9).
They underwent interfascicular neurolysis for sciatic nerve palsy,
after failing a trial of non-operative treatment for a minimum of
six months. Following surgery, a statistically and clinically significant
improvement in motor function was seen in all patients. The mean
peroneal nerve score function improved from 0.42 (0 to 3) to 3 (1
to 5) (p <
0.001). The mean tibial nerve motor function score
improved from 1.75 (1 to 4) to 3.92 (3 to 5) (p = 0.02).The mean
improvement in sensory function was a clinically negligible 1 out
of 5 in all patients. In total, 11 patients reported improvement
in their pain following surgery. We conclude that neurolysis of the sciatic nerve has a favourable
prognosis in patients with a sciatic nerve palsy following THA.
Our findings suggest that surgery should not be delayed for >
12
months following injury. Cite this article:
The last decade has seen a considerable increase
in the use of in total ankle arthroplasty (TAA) to treat patients
with end-stage arthritis of the ankle. However, the longevity of
the implants is still far from that of total knee and hip arthroplasties. The aim of this review is to outline a diagnostic and treatment
algorithm for the painful TAA to be used when considering revision
surgery. Cite this article:
This short contribution aims to explain how intervertebral disc ‘degeneration’ differs from normal ageing, and to suggest how mechanical loading and constitutional factors interact to cause disc degeneration and prolapse. We suggest that disagreement on these matters in medico-legal practice often arises from a misunderstanding of the nature of ‘soft-tissue injuries’.
The aim of this study was to determine whether chilled irrigation
saline decreases the incidence of clinical upper limb palsy (ULP;
a reduction of one grade or more on manual muscle testing; MMT),
based on the idea that ULP results from thermal damage to the nerve
roots by heat generated by friction during bone drilling. Irrigation saline for drilling was used at room temperature (RT,
25.6°C) in open-door laminoplasty in 400 patients (RT group) and
chilled to a mean temperature of 12.1°C during operations for 400
patients (low-temperature (LT) group). We assessed deltoid, biceps,
and triceps brachii muscle strength by MMT. ULP occurring within
two days post-operatively was categorised as early-onset palsy.Aims
Methods
Mesenchymal stem cells have the ability to differentiate into various cell types, and thus have emerged as promising alternatives to chondrocytes in cell-based cartilage repair methods. The aim of this experimental study was to investigate the effect of bone marrow derived mesenchymal stem cells combined with platelet rich fibrin on osteochondral defect repair and articular cartilage regeneration in a canine model. Osteochondral defects were created on the medial femoral condyles of 12 adult male mixed breed dogs. They were either treated with stem cells seeded on platelet rich fibrin or left empty. Macroscopic and histological evaluation of the repair tissue was conducted after four, 16 and 24 weeks using the International Cartilage Repair Society macroscopic and the O’Driscoll histological grading systems. Results were reported as mean and standard deviation (Objectives
Methods
This is the first prospective study to report the pre- and post-operative
patient reported outcomes and satisfaction scores following excision
of interdigital Morton’s neuroma. Between May 2006 and April 2013, we prospectively studied 99
consecutive patients (111 feet) who were to undergo excision of
a Morton’s neuroma. There were 78 women and 21 men with a mean age
at the time of surgery of 56 years (22 to 78). Patients completed
the Manchester-Oxford Foot Questionnaire (MOXFQ), Short Form-12
(SF-12) and a supplementary patient satisfaction survey three months
pre-operatively and six months post-operatively.Aims
Patients and Methods
Peripheral nerve injury is an uncommon but serious
complication of hip surgery that can adversely affect the outcome.
Several studies have described the use of electromyography and intra-operative
sensory evoked potentials for early warning of nerve injury. We
assessed the results of multimodal intra-operative monitoring during
complex hip surgery. We retrospectively analysed data collected
between 2001 and 2010 from 69 patients who underwent complex hip
surgery by a single surgeon using multimodal intra-operative monitoring
from a total pool of 7894 patients who underwent hip surgery during
this period. In 24 (35%) procedures the surgeon was alerted to a
possible lesion to the sciatic and/or femoral nerve. Alerts were
observed most frequently during peri-acetabular osteotomy. The surgeon
adapted his approach based on interpretation of the neurophysiological changes.
From 69 monitored surgical procedures, there was only one true positive
case of post-operative nerve injury. There were no false positives
or false negatives, and the remaining 68 cases were all true negative.
The sensitivity for predicting post-operative nerve injury was 100%
and the specificity 100%. We conclude that it is possible and appropriate
to use this method during complex hip surgery and it is effective
for alerting the surgeon to the possibility of nerve injury.
We present the clinical and radiographic outcome of 81 children
with Gartland type I to III supracondylar humeral fractures at a
minimum follow-up of ten years (mean 12.1 years; 10.3 to 16.1) following
injury. The clinical and functional outcomes are compared with normal
age- and gender-matched individuals. The population-based study
setting was first identified from the institutional registries;
the rate of participation was 76%. Controls were randomly selected
from Finnish National Population Registry.Aims
Patients and Methods
The acetabular labrum is a soft-tissue structure
which lines the acetabular rim of the hip joint. Its role in hip
joint biomechanics and joint health has been of particular interest
over the past decade. In normal hip joint biomechanics, the labrum
is crucial in retaining a layer of pressurised intra-articular fluid
for joint lubrication and load support/distribution. Its seal around
the femoral head is further regarded as a contributing to hip stability through
its suction effect. The labrum itself is also important in increasing
contact area thereby reducing contact stress. Given the labrum’s
role in normal hip joint biomechanics, surgical techniques for managing
labral damage are continuously evolving as our understanding of
its anatomy and function continue to progress. The current paper
aims to review the anatomy and biomechanical function of the labrum
and how they are affected by differing surgical techniques. Take home message: The acetabular labrum plays a critical role
in hip function and maintaining and restoring its function during
surgical intervention remain an essential goal. Cite this article:
This paper aims to provide evidence-based guidance for the general orthopaedic surgeon faced with the presentation of a potential soft tissue sarcoma in an extremity.
The custom triflange is a patient-specific implant
for the treatment of severe bone loss in revision total hip arthroplasty
(THA). Through a process of three-dimensional modelling and prototyping,
a hydroxyapatite-coated component is created for acetabular reconstruction.
There are seven level IV studies describing the clinical results
of triflange components. The most common complications include dislocation
and infection, although the rates of implant removal are low. Clinical
results are promising given the challenging problem. We describe
the design, manufacture and implantation process and review the
clinical results, contrasting them to other methods of acetabular
reconstruction in revision THA. Cite this article:
The December 2015 Shoulder &
Elbow Roundup360 looks at:
We examined the outcomes and levels of patient
satisfaction in 202 consecutive cases of ultrasound-guided supraclavicular
brachial plexus block (SBPB) in upper limb surgery performed between
September 2007 and March 2010. All blocks were performed by orthopaedic surgeons using ultrasound
visualisation with a high-frequency linear probe. The probe was
placed in the coronal–oblique plane in the supraclavicular fossa,
and the puncture was ‘in-plane’ from lateral to medial. Most of
the blocks were performed with 0.75% ropivacaine/1% lidocaine (1:1),
with or without adrenaline in 1:200 000 dilution. In 201 patients
(99.5%) the brachial plexus block permitted surgery without conversion
to general anaesthesia. The mean procedure time for block was 3.9
min (2 to 12), the mean waiting time for surgery was 34.1 min (10
to 64), the mean surgical time was 75.2 min (6 to 232), and the
mean duration of post-anaesthetic analgesia was 437 min (171 to
992). A total of 20 patients (10%) developed a transient Horner’s syndrome.
No nerve injury, pneumothorax, arterial puncture or systemic anaesthetic
toxicity were recorded. Most patients (96.7%) were satisfied with
ultrasound-guided SBPB. This study demonstrates the efficacy and
safety of ultrasound-guided SBPB for orthopaedic surgery on the
upper limb. Cite this article:
An uncemented hemispherical acetabular component
is the mainstay of acetabular revision and gives excellent long-term
results. Occasionally, the degree of acetabular bone loss means that a
hemispherical component will be unstable when sited in the correct
anatomical location or there is minimal bleeding host bone left
for biological fixation. On these occasions an alternative method
of reconstruction has to be used. A major column structural allograft has been shown to restore
the deficient bone stock to some degree, but it needs to be off-loaded
with a reconstruction cage to prevent collapse of the graft. The
use of porous metal augments is a promising method of overcoming
some of the problems associated with structural allograft. If the defect
is large, the augment needs to be protected by a cage to allow ingrowth
to occur. Cup-cage reconstruction is an effective method of treating
chronic pelvic discontinuity and large contained or uncontained
bone defects. This paper presents the indications, surgical techniques and
outcomes of various methods which use acetabular reconstruction
cages for revision total hip arthroplasty. Cite this article:
We report a prospective cohort study of the midterm results of
surgical dislocation of the hip (according to Ganz) to perform resection
of osteochondromas involving the femoral neck in patients with multiple
hereditary exostoses (MHE). Hip range of movement (ROM) was assessed pre- and post-operatively.
Patients’ judgment of post-operative reduction of pain, symptoms,
the Rand 36-item Health Survey (RAND-36) and complications were
analysed. Aims
Methods
Restoration of hand function is rarely achieved after a complete closed traction lesion of the supraclavicular brachial plexus. We describe the injury, treatment, rehabilitation and long-term results of two patients who regained good function of the upper limb and useful function in the hand after such an injury. Successful repairs were performed within six days of injury. Tinel’s sign proved accurate in predicting the ruptures and the distribution of pain was accurate in predicting avulsion. The severe pain that began on the day of injury resolved with the onset of muscle function. Recovery of muscle function preceded recovery of sensation. Recovery of the function of C and Aδ fibres was the slowest of all.
Between 2005 and 2012, 50 patients (23 female, 27 male) with
nonunion of the humeral shaft were included in this retrospective
study. The mean age was 51.3 years (14 to 88). The patients had
a mean of 1.5 prior operations ( All patients were assessed according to a specific risk score
in order to devise an optimal and individual therapy plan consistent
with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis
to an angular stable locking compression plate was performed. According
to the individual risk an additional bone graft and/or bone morphogenetic
protein-7 (BMP-7) were applied. A successful consolidation of the nonunion was observed in 37
cases (80.4%) with a median healing time of six months (IQR 6).
Younger patients showed significantly better consolidation. Four
patients were lost to follow-up. Revision was necessary in a total
of eight (16%) cases. In the initial treatment, intramedullary nailing
was most common. Methods
Results