Between 1981 and 1986 two groups of patients received either Charnley low-friction
The Motec cementless modular metal-on-metal ball-and-socket
wrist
We have performed a form of lunate
We report 60 patients with tuberculosis of the hip treated by Charnley low friction
We describe the mid-term clinical results of the surgical treatment of primary degenerative arthritis of the sternoclavicular joint in eight women. They had not responded to conservative treatment and underwent a limited resection
We developed an in vivo model of the attachment of a patellar tendon to a metal implant to simulate the reconstruction of an extensor mechanism after
Early mobilisation after
We have made a retrospective comparison between the results of 49 high tibial osteotomies and 42 unicompartmental
We have examined the relief from pain and the functional outcome in 18 patients who underwent resection
We present the histological findings of bone retrieved from beneath the femoral components of failed metal-on-metal hip resurfacing arthroplasties. Of a total of 377 patients who underwent resurfacing
A randomised prospective trial was undertaken of antibiotic prophylaxis given at various intervals before inflation of the tourniquet for
Eighteen patients with marginal depressed or comminuted fractures of the head of the radius, nine of whom had an associated posterior dislocation of the elbow, had a Silastic
We have reviewed 15 patients with infected total knee replacements after removal of the prosthesis, rigorous debridement, antibiotic irrigation, and prolonged systemic antibiotics. Infection was permanently eradicated in all patients; they were left with a functioning limb, on which they could walk with either a caliper (8 patients), a simple splint (3), crutches, or sticks. Three were disappointed because of residual pain. We believe that, if exchange
1. The various surgical procedures in common use for the treatment of the osteoarthritic hip are briefly reviewed and compared with the operation of
Between 1969 and 1985 26 patients with destructive lesions of the distal humerus were treated by endoprosthetic
We have studied the use of filamentous polyglycolic acid (Dexon) for the induction of neotendon in the calcaneal tendon of sheep. Uniformly good results were obtained, with the formation of a thick neotendon. However, in a control group the power of spontaneous regeneration of the tendon was studied; it was found that, provided overlengthening of the gap was prevented, an equally good tendon resulted. It is concluded that this particular model is not an appropriate one for testing neotendon induction, despite its use for this purpose in the past. The favourable results of using filamentous polyglycolic acid as a tendon
A retrospective study of 44 diabetic patients who, between them, had 62 Charnley low-friction
More than a million hip replacements are carried out each year worldwide, and the number of other artificial joints inserted is also rising, so that infections associated with
We performed a meta-analysis of modern total
joint
Limb salvage is now customary in the treatment of primary bone tumours. The proximal tibia is a frequent site for these neoplasms but reconstruction, especially in children, is a formidable challenge. We reviewed 20 children with extendible