Advertisement for orthosearch.org.uk
Results 221 - 240 of 612
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 3 - 8
1 Jul 2021
Roberts HJ Barry J Nguyen K Vail T Kandemir U Rogers S Ward D

Aims

While interdisciplinary protocols and expedited surgical treatment improve the management of hip fractures in the elderly, the impact of such interventions on patients specifically undergoing arthroplasty for a femoral neck fracture is not clear. We sought to evaluate the efficacy of an interdisciplinary protocol for the management of patients with a femoral neck fracture who are treated with an arthroplasty.

Methods

In 2017, our institution introduced a standardized interdisciplinary hip fracture protocol. We retrospectively reviewed adult patients who underwent hemiarthroplasty (HA) or total hip arthroplasty (THA) for femoral neck fracture between July 2012 and March 2020, and compared patient characteristics and outcomes between those treated before and after the introduction of the protocol.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 362 - 365
1 May 1990
Holdsworth B Mossad M

We reviewed 57 adult patients at an average of 37 months after early internal fixation for displaced fractures of the distal humerus. Two-thirds had intercondylar (Muller type C) fractures, and one-third had articular comminution (type C3). A chevron olecranon osteotomy was used, with early active movement after fixation. Results were good or excellent in 76% with an average range of movement of 115 degrees. Early stable fixation by an experienced surgeon is recommended for these fractures


Bone & Joint Open
Vol. 2, Issue 10 | Pages 858 - 864
18 Oct 2021
Guntin J Plummer D Della Valle C DeBenedetti A Nam D

Aims

Prior studies have identified that malseating of a modular dual mobility liner can occur, with previous reported incidences between 5.8% and 16.4%. The aim of this study was to determine the incidence of malseating in dual mobility implants at our institution, assess for risk factors for liner malseating, and investigate whether liner malseating has any impact on clinical outcomes after surgery.

Methods

We retrospectively reviewed the radiographs of 239 primary and revision total hip arthroplasties with a modular dual mobility liner. Two independent reviewers assessed radiographs for each patient twice for evidence of malseating, with a third observer acting as a tiebreaker. Univariate analysis was conducted to determine risk factors for malseating with Youden’s index used to identify cut-off points. Cohen’s kappa test was used to measure interobserver and intraobserver reliability.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 124 - 127
1 Jan 1987
Ford D Khoury G el-Hadidi S Lunn P Burke F

We have reviewed 22 patients with scaphoid fractures treated by internal fixation with the Herbert screw. Three patients had trans-scaphoid perilunar dislocations, one had an oblique displaced fracture of the waist of the scaphoid and 18 had fractures with delayed or non-union. Corticocancellous bone grafts were added in nine of the cases of non-union. Results were excellent or good in 80% of cases after a mean duration of postoperative immobilisation of four weeks. The technical difficulties are analysed and the problems of applying the jig and of operative exposure are discussed


Bone & Joint 360
Vol. 10, Issue 5 | Pages 15 - 18
1 Oct 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 173 - 177
1 Mar 2002
Schandelmaier P Blauth M Schneider C Krettek C

We describe the results after open reduction and internal fixation of 22 consecutive displaced fractures of the glenoid with a mean follow-up of ten years. A posterior approach was used in 16 patients and an anterior in six, the approach being chosen according to the Ideberg classification of the fractures. The fixation failed in two patients, one of whom required a further operation. There were two cases of deep infection. At follow-up the median Constant score was 94% (mean 79%, range 17 to 100). The score was less than 50% in four patients, including the two who became infected. A further two had an associated complete palsy of the brachial plexus


Bone & Joint 360
Vol. 10, Issue 5 | Pages 29 - 32
1 Oct 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 186 - 188
1 Mar 1989
Chen S Badrinath K Pell L Mitchell K

We aimed to find out whether the Hastings bipolar prosthesis moved in a bipolar fashion after its use for displaced fractures of the femoral neck. In 65 patients non-weight-bearing movement was assessed radiographically and compared with an earlier study of the Monk prosthesis. In 70% of patients, the only movement was between the acetabulum and the prosthetic shell, the prosthesis behaving as if it were unipolar. This did not change with time, but there was a slight improvement in the range of movement, particularly in flexion. The absence of movement between the outer shell and the metal head is most probably due to the design of the prosthesis and makes this prosthesis unsuitable for use in osteoarthritic hips


Bone & Joint 360
Vol. 10, Issue 2 | Pages 21 - 23
1 Apr 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1613 - 1617
1 Dec 2006
Karunakar MA Sen A Bosse MJ Sims SH Goulet JA Kellam JF

Our study was designed to compare the effect of indometacin with that of a placebo in reducing the incidence of heterotopic ossification in a prospective, randomised trial. A total of 121 patients with displaced fractures of the acetabulum treated by operation through a Kocher-Langenbeck approach was randomised to receive either indometacin (75 mg) sustained release, or a placebo once daily for six weeks. The extent of heterotopic ossification was evaluated on plain radiographs three months after operation. Significant ossification of Brooker grade III to IV occurred in nine of 59 patients (15.2%) in the indometacin group and 12 of 62 (19.4%) receiving the placebo. We were unable to demonstrate a statistically significant reduction in the incidence of severe heterotopic ossification with the use of indometacin when compared with a placebo (p = 0.722). Based on these results we cannot recommend the routine use of indometacin for prophylaxis against heterotopic ossification after isolated fractures of the acetabulum


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 615 - 619
1 Aug 1987
Bostman O Vainionpaa S Hirvensalo E Makela A Vihtonen K Tormala P Rokkanen P

Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable internal fixation routinely to treat displaced malleolar fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 734 - 737
1 Sep 1997
Guichet J Moller C Dautel G Lascombes P

Anteriorly displaced fractures of the wrist can be treated by the Kapandji technique of percutaneous intrafocal pinning with pins inserted through an anterior approach to give good reduction and stabilisation of the fracture. We have modified this technique by placing the pins through a posterior approach which decreases the risks of neurovascular damage. We have used this method to treat six children with distal radial fractures showing anterior displacement or instability. Good anterior stabilisation was achieved. The pins were removed at an average of eight weeks and the patients were then able to return to full activity. This simple technique can be used for unstable fractures after the failure of conservative treatment or in bilateral fractures in adolescents


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 178 - 181
1 Mar 1986
Gopalakrishnan K el Masri W

Twelve cases of sternal injury associated with spinal fractures have been reviewed. The sternum is regularly buckled or fractured in patients with high thoracic spinal fractures. Our review suggests that sternal injuries may also be associated with spinal fractures outside this region, and with types of fracture other than crushing of vertebral bodies. Injury to the sternum, when due to indirect violence, is almost always associated with a severe spinal column injury. A displaced fracture of the thoracic spine, with or without an associated sternal fracture, can produce significant widening of the mediastinal shadow on a chest radiograph. This is caused by a paravertebral haematoma, and can be difficult to differentiate from widening due to an aortic rupture


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 2 | Pages 305 - 311
1 May 1963
Hargadon EJ Pearson JR

1. A series of 100 intracapsular fractures of the femoral neck treated with the Charnley compression screw is reported. 2. There were six deaths, and in patients reviewed long enough (seventy-five) there were eleven undisplaced fractures, with successful union in 8l·8 per cent, and sixty-four displaced fractures, with a union rate of 59·6 per cent. 3. If we exclude six failures of operative technique, there remain fifty-eight patients in whom the fracture was judged radiologically to have united in 65·5 per cent. 4. The Charnley compression screw is an effective method of internal fixation in such fractures, and non-union with this method is usually due to causes other than mechanical failure


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 3 - 4
1 Jan 2021
Parker M


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 4 | Pages 603 - 612
1 Nov 1974
Lewis J McKibbin B

1. The results of treatment have been compared in two unselected series of patients with unstable fractures of the thoraco-lumbar spine accompanied by paraplegia. 2. One group had been treated by conservative or " postural" methods while the others had been subjected to open reduction and internal fixation with double plates. 3. No difference in the amount of neurological recovery could be detected between the two groups but while a number of conservatively treated patients had significant residual spinal deformity and subsequently developed serious pain, this did not occur in any of the patients treated by plating. 4. It is concluded that open reduction and internal fixation are indicated in displaced fractures in the interests of long-term spinal function


Bone & Joint 360
Vol. 10, Issue 3 | Pages 16 - 20
1 Jun 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 596 - 599
1 Jul 1999
Konishiike T Makihata E Tago H Sato T Inoue H

We performed dynamic MRI of the femoral head within 48 hours of injury on 22 patients with subcapital fracture of the neck of the femur and on a control group of 20 of whom ten were healthy subjects and ten were patients with an intertrochanteric fracture. Three MRI patterns emerged when the results between the fractured side and the contralateral femoral head were compared. In all of the control group and in those patients who had undisplaced fractures (Garden stages I and II), perfusion of the femoral head was considered to be at the same level as on the unaffected side. In patients with displaced fractures (Garden stages III and IV) almost all the femoral heads on the fractured side were impaired or totally avascular, although some had the same level of perfusion as the unaffected side. We conclude that dynamic MRI, a new non-invasive imaging technique, is useful for evaluating the perfusion of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 617 - 619
1 Jul 1992
Christen B Jakob R

We reviewed retrospectively 490 patellar ligament reconstructions for cruciate ligament injuries performed from 1980 to 1990. There were six cases of patellar splitting and three displaced patellar fractures in donor knees. The fissure fractures all occurred during the removal of the patellar bone block. The displaced fractures were sustained during early rehabilitation, and in two of the three patients, involved the normal contralateral knee. The major reasons for this complication were imprecise saw cuts, spreading osteotomies, and the use of a too large patellar bone block. When a trapezoidal bone block is used to self-lock in the femoral tunnel, this should preferably be taken from the tibia. Special care is needed in rehabilitation when the graft has been taken from the contralateral knee


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1050 - 1052
1 Nov 1990
Moda S Chadha N Sangwan S Khurana D Dahiya A Siwach R

Open reduction and internal fixation was employed in the treatment of 25 severely displaced fractures and fracture-dislocations of the proximal humerus. Our aims were accurate reduction and stable fixation to allow early mobilisation and to achieve full functional recovery. In 15 fractures an AO T-plate was used and in 10 a bent semitubular plate was employed as a blade plate. Excellent or satisfactory results were obtained in all six patients with two-part fractures involving the surgical neck; in four of the five patients with three-part fractures involving the surgical neck and tuberosities; in nine of the 11 patients with fracture-dislocation; and in two of the three patients with split fractures of the humeral head. Overall results were good or satisfactory in 21 of the 25 cases. Unsatisfactory results were associated with rotator cuff damage