Advertisement for orthosearch.org.uk
Results 221 - 240 of 2367
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 242 - 245
1 Mar 1989
Broughton N Olney B Menelaus M

Over a 25-year period, 12 patients had from 2.5 to 5.1 cm operative shortening of the tibia and fibula for leg length discrepancy at between four and 18 years of age. All recovered normal function and there was minor cosmetic impairment in only two cases. The only vascular complication was temporary delay in return of the circulation to the foot after tourniquet removal in one patient. The procedure is valuable for discrepancy of tibial length in patients when they present too late for epiphyseal arrest, when there is doubt as to the appropriate timing for epiphyseal arrest, or when it is uncertain at an earlier stage whether there is need for surgical correction


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 417 - 421
1 May 1995
Court-Brown C McBirnie J

We performed an epidemiological analysis of 523 fractures treated in the Edinburgh Orthopaedic Trauma Unit over a three-year period using modern descriptive criteria. The fractures were defined in terms of their AO morphology and their degree of comminution, location and cause. Closed fractures were classified using the Tscherne grading system and open fractures according to the Gustilo classification. Further analysis of fractures caused by road-traffic accidents and football was carried out. The use of the AO classification allowed the common fracture patterns to be defined. Correlation of the classification systems showed an association between the AO morphological system and the Tscherne and Gustilo classifications. The relative rarity of severe tibial fractures is indicated and it is suggested that in smaller orthopaedic units the infrequency of these fractures has implications for training and the development of treatment protocols


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 220 - 225
1 Mar 1996
Abernethy PJ Robinson CM Fowler RM

We reviewed 1567 elective knee replacements performed between 1980 and 1990, using either the Total Condylar prosthesis with an all-plastic tibial component, or the Kinematic prosthesis which has a metal tibial tray. The ten-year probability of survival was 92.1% for the Total Condylar design and 87.9% for the Kinematic. The difference was mainly due to 16 revisions required in the Kinematic series for fracture of the metal base-plate. This was the most common cause of aseptic failure in this group. These fractures were strongly associated with a preoperative varus deformity (hazard ratio (HR) 8.8) and there was a slightly increased risk in males (HR 1.9) and in osteoarthritic knees (HR 1.8). In the nine fractures which occurred within four years of primary implantation (group 1), failure to correct adequately a preoperative varus deformity and the use of a bone graft to correct such a deformity were both strongly associated with fracture (HR 13.9 and 15.8, respectively). In eight fractures which occurred more than five years after primary replacement (group 2) we could detect no significant risk factors. Early complications occurred in two patients after the 16 revision procedures for tray fracture. One had a deep infection and the other refracture of the tray


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 50 - 54
1 Jan 1995
Takakura Y Tanaka Y Kumai T Tamai S

Primary osteoarthritis of the ankle with no history of trauma is rare. We report the use of a low tibial osteotomy on 18 ankles in 18 patients, two men and 16 women. The osteotomy is designed to correct the varus tilt and anterior opening of the distal tibial joint surface where it has been shown by weight-bearing radiographs and arthroscopy that there is healthy articular cartilage on the lateral side of the ankle. An opening-wedge osteotomy was used to achieve slight overcorrection. Follow-up of the 18 ankles at an average of 6 years 11 months (2.7 to 12.10) showed the results by our own scoring system to be excellent in six ankles, good in nine, and fair in three with no poor results. Of the three patients with fair results, two had been undercorrected and the third had little residual articular cartilage. Arthroscopic examination of ten ankles showed repair by fibrocartilage in seven. We conclude that slight overcorrection of deformity by low tibial osteotomy is effective in treating intermediate-stage primary osteoarthritis of the ankle


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 412 - 416
1 May 1995
Richardson J Gardner T Hardy Evans M Kuiper J Kenwright J

We studied the effect of 'dynamisation' on tibial fractures in six patients treated by the Dynamic Axial Fixator. In the early stages, peak cyclic movement at two to four weeks averaged 0.75 mm (0.19 to 1.02) on the medial side of the bone and 0.86 mm (0.21 to 1.25) on the lateral side. The amount of movement correlated with the applied load and the fracture stiffness. After unlocking the fixator column at six weeks, progressive closure of the gap averaged 1.3 mm (0.1 to 3.5). Cyclic movement is produced by early weight-bearing with the fixator column locked. Progressive closure occurs after unlocking the column, and is often associated with a reduction in cyclic movements. The effects of dynamisation on movement at the fracture site should be defined separately, in terms of cyclic movement and of progressive closure


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 121 - 124
1 Jan 1990
Galardi G Comi G Lozza L Marchettini P Novarina M Facchini R Paronzini A

Limb lengthening is used to correct leg length discrepancy and to increase stature. The reported frequency of peripheral nerve complications varies from 5% to 30%, but is probably underestimated. Damage may be direct or be caused by overstretching of the nerves. We have used electrophysiological tests to evaluate five patients during bilateral tibial lengthening by the Ilizarov method. Results after 24 to 107 days of lengthening showed electromyographic evidence of partial muscle denervation in all 10 limbs, with reduced motor conduction velocities in two tibial nerves and three common peroneal nerves. The sensory conduction velocity in the sural nerve was always unchanged. A clear relationship was shown between the amount of tibial lengthening and the degree of electrophysiological abnormality. Our results suggest that subclinical nerve damage is a very frequent complication of tibial lengthening


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1164 - 1171
1 Sep 2009
Bae DK Song SJ Yoon KH

We assessed the reliability, accuracy and variability of closed-wedge high tibial osteotomy (HTO) using computer-assisted surgery compared to the conventional technique. A total of 50 closed-wedge HTO procedures were performed using the navigation system, and compared with 50 HTOs that had been performed with the conventional technique. In the navigation group, the mean mechanical axis prior to osteotomy was varus 8.2°, and the mean mechanical axis following fixation was valgus 3.6°. On the radiographs the mean pre-operative mechanical axis was varus 7.3°, and the mean post-operative mechanical axis was valgus 2.1°. There was a positive correlation between the measured data taken under navigation and by radiographs (r > 0.3, p < 0.05). The mean correction angle was significantly more accurate in the navigation group (p < 0.002). The variability of the correction was significantly lower in the navigation group (2.3° vs 3.7°, p = 0,012). We conclude that navigation provides reliable real-time intra-operative information, may increase accuracy, and improves the precision of a closed-wedge HTO


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 893 - 896
1 Nov 1992
Pattinson R Fixsen J

Tibial dysplasia is a rare congenital deformity which must be distinguished from the more common fibular dysplasia. We have reviewed 24 patients with 35 affected legs. The classification system of Kalamchi and Dawe (1985) was found to be preferable to that of Jones, Barnes and Lloyd-Roberts (1978) as a guide to prognosis and management. We discuss the outcome of surgical treatment, recommending selective amputation for most cases


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 4 | Pages 746 - 751
1 Nov 1961
Jackson JP Waugh W

1. The results are presented of upper tibial osteotomy carried out in ten patients for osteoarthritis of the knee associated with lateral deformity. 2. The operation is indicated when there is severe pain, valgus or varus deformity, and a range of flexion of at least 90 degrees. 3. In every case pain has been relieved, and recovery of movement after operation has been easy


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 605 - 611
1 Jul 1990
Court-Brown C Christie J McQueen M

We present the results of using the Grosse-Kempf interlocking nail in the management of 125 closed and type I open tibial fractures. The mean time to union was 16.7 weeks and no fracture required bone grafting. Mobilisation of the patient and the range of joint movement were better than with other methods of treating tibial fractures. There was a 1.6% incidence of infection; 40.8% of patients had knee pain and 26.4% needed to have the nail removed. Other complaints were minor. We suggest that closed intramedullary nailing with an interlocking nail system is an excellent method of treating closed and type I open tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 523 - 528
1 Aug 1984
Tibrewal S Grant K Goodfellow J

Radiolucent lines at the bone-cement interface beneath the tibial components were assessed in 91 consecutive Oxford meniscal knee replacements in 78 patients. Of 80 knees in which radio-opaque cement was used, a radiolucent line was observed in 77, with a radiodense line in the bone immediately adjoining. Radiolucent lines developed in the majority of patients within one year after operation. In 11 knees fixed with radiolucent cement (which precluded assessment of the radiolucent line) a radiodense line was observed beneath the lucent cement in all cases. Histological examination of the interface obtained from secure tibial components showed the lucent zone to be composed of fibrocartilaginous connective tissue and the radiodense line to be a thick lamella of bone. It is suggested that the living bone under a rigid prosthesis requires a layer of relatively compliant fibrocartilaginous material at its interface to accommodate load-bearing. Attention is drawn to the importance of the radiodense line: its presence may constitute positive evidence that healing at the level of bone section is complete and that equilibrium is established; its absence at a mature interface may indicate disequilibrium and impending failure


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 3 | Pages 326 - 328
1 May 1983
Merriam W Porter K

One hundred patients who had sustained a fracture of the tibial shaft and had been treated by internal fixation were reviewed to obtain information on residual ankle and subtalar disability. This study reinforces the belief that early mobilisation of patients with tibial shaft fractures does help to preserve subtalar movement


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 239 - 243
1 Mar 2004
Cutler L Molloy A Dhukuram V Bass A

Distal tibial physeal fractures are the second most common growth plate injury and the most common cause of growth arrest and deformity. This study assesses the accuracy of pre-operative planning for placement of the screws in these fractures using either standard radiographs or CT scans. We studied 62 consecutive physeal fractures over a period of four years. An outline of a single cut of the CT scan was used for each patient. An ideal position for the screw was determined as being perpendicular to and at the midpoint of the fracture. The difference in entry point and direction of the screw between the ideal and the observers’ assessments were compared using the paired Student’s t-test. There was a statistically significant improvement (p < 0.0001) in the accuracy of the point of insertion and the direction of the screw on the pre-operative plan when CT scans were used rather than plain radiographs. We would, therefore, recommend that CT scans are routinely used in the pre-operative assessment and treatment of distal tibial physeal fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 68 - 73
1 Jan 2003
Keating JF Hajducka CL Harper J

We used calcium-phosphate cement combined with minimal internal fixation to treat 49 fractures of the lateral tibial plateau. There were 25 split depression fractures, 22 pure depression fractures and two bicondylar fractures. Anatomical reduction was obtained in 38 fractures, satisfactory reduction in nine and imperfect reduction in two. Of 44 patients reviewed at one year, 33 were rated as having an excellent reduction. Functional outcome as measured by the Rasmussen score was good or excellent at six months in 92% (44/48) of patients and in 95% (42/44) at one year. Eight (16%) showed some loss of reduction of the plateau. In seven of these the loss of reduction was slight (< 3 mm) and no action was taken. One patient with a deep infection had gross loss of reduction and a poor functional outcome. Calcium-phosphate cement is a useful alternative to bone grafting for the treatment of fractures of the tibial plateau


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 444 - 445
1 May 1997
Takakuwa M Funakoshi M Ishizaki K Aono T Hamaguchi H

We report four patients who sustained secondary fractures of the posterior wall of the tibial shaft during the removal of one pattern of intramedullary nail after fracture healing. The cause of this complication is discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 45-B, Issue 1 | Pages 142 - 144
1 Feb 1963
Crellin RQ Tsapogas MJC

1. A case of traumatic aneurysm of the anterior tibial artery complicating fracture of the tibia and fibula is reported. 2. The diagnosis and management of such lesions are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 928 - 932
1 Jul 2006
Patil S Montgomery R

We reviewed 78 femoral and tibial nonunions treated between January 1992 and December 2003. Of these, we classified 41 in 40 patients as complex cases because of infection (22), bone loss (6) or failed previous surgery (13). The complex cases were all treated with Ilizarov frames. At a mean time of 14.1 months (4 to 38), 39 had healed successfully. Using the Association for the Study and Application of the Methods of Ilizarov scoring system we obtained 17 excellent, 14 good, four fair and six poor bone results. The functional results were excellent in 14 patients, good in 14, fair in two and poor in two. A total of six patients were lost to follow-up and two had amputations so were not evaluated for final functional assessment. All but two patients were very satisfied with the results. The average cost of treatment to the treating hospital was approximately £30 000 per patient. We suggest that early referral to a tertiary centre could reduce the morbidity and prolonged time off work for these patients. The results justify the expense, but the National Health Service needs to make financial provision for the reconstruction of this type of complex nonunion


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 448 - 451
1 May 1991
Thakur A Patankar J

Seventy-nine open tibial fractures were treated with unilateral uniplanar tubular external fixators. Excellent stability allowed early weight-bearing. All comminuted fractures, with or without bone loss, and some transverse or short oblique fractures with intermediate fragments were treated by early bone grafting through a posterolateral approach. The external fixator was dynamised as soon as periosteal callus was seen on the radiograph. Bone healing times ranged from 11 to 40 weeks (mean 20). Significant ankle stiffness occurred in 10.9% and leg shortening in 2.8%. Pin track infection was seen in 45.2% but was easily controlled with standard management. The external fixation frame allowed excellent functional freedom for Oriental patients to sit cross-legged and squat. Combined with early bone grafting, external fixation is an excellent method for the management of open tibial fractures


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 339 - 344
1 Mar 2014
Saito T Kumagai K Akamatsu Y Kobayashi H Kusayama Y

Between 2003 and 2007, 99 knees in 77 patients underwent opening wedge high tibial osteotomy. We evaluated the effect of initial stable fixation combined with an artificial bone substitute on the mid- to long-term outcome after medial opening-wedge high tibial osteotomy (HTO) for medial compartmental osteoarthritis or spontaneous osteonecrosis of the knee in 78 knees in 64 patients available for review at a minimum of five years (mean age 68 years; 49 to 82). The mean follow-up was 6.5 years (5 to 10). The mean Knee Society knee score and function score improved from 49.6 (. sd. 11.4, 26 to 72) and 56.6 (. sd. 15.6, 5 to 100) before surgery to 88.1 (. sd. 12.5, 14 to 100) and 89.4 (. sd. 15.6, 5 to 100) at final follow-up (p <  0.001) respectively. There were no significant differences between patients aged ≥ 70 and < 70 years. The mean standing femorotibial angle was corrected significantly from 181.7° (. sd.  2.7°, 175° to 185°) pre-operatively to 169.7° (. sd. 2.4°, 164° to 175°) at one year’s follow-up (p < 0.001) and 169.6° (. sd. 3.0°, 157° to 179°) at the final follow-up (p = 0.69 vs one year). . Opening-wedge HTO using a stable plate fixation system combined with a bone substitute is a reliable procedure that provides excellent results. Although this treatment might seem challenging for older patients, our results strongly suggest that the results are equally good. Cite this article: Bone Joint J 2014;96-B:339–44


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 959 - 964
1 Nov 1991
Court-Brown C McQueen M Quaba A Christie J

We report the use of Grosse-Kempf reamed intramedullary nailing in the treatment of 41 Gustilo type II and III open tibial fractures. The union times and infection rates were similar to those previously reported for similar fractures treated by external skeletal fixation, but the incidence of malunion was less and fewer required bone grafting. The role of exchange nailing is discussed and a treatment protocol is presented for the management of delayed union and nonunion