There are two techniques widely used to determine the rotational
alignment of the components in total knee arthroplasty (TKA); gap
balancing (GB) and measured resection (MR). Which technique is the
best remains controversial. We aimed to investigate this in a systematic
review and meta-analysis. In accordance with the methods of Cochrane, databases were searched
for all randomised controlled trials in the literature between January
1986 and June 2015 comparing radiographic and clinical outcomes
between the use of these two tecniques. Meta-analysis involved the
use of the Revman5.3 software provided by Cochrane collaboration.Aims
Materials and Methods
Periprosthetic joint infection (PJI) is a serious complication
of total hip arthroplasty (THA). Different bearing surface materials
have different surface properties and it has been suggested that
the choice of bearing surface may influence the risk of PJI after
THA. The objective of this meta-analysis was to compare the rate
of PJI between metal-on-polyethylene (MoP), ceramic-on-polyethylene
(CoP), and ceramic-on-ceramic (CoC) bearings. Electronic databases (Medline, Embase, Cochrane library, Web
of Science, and Cumulative Index of Nursing and Allied Health Literature)
were searched for comparative randomized and observational studies
that reported the incidence of PJI for different bearing surfaces.
Two investigators independently reviewed studies for eligibility, evaluated
risk of bias, and performed data extraction. Meta-analysis was performed
using the Mantel–Haenzel method and random-effects model in accordance
with methods of the Cochrane group.Aims
Patients and Methods
Tranexamic acid (TXA) is an antifibrinolytic agent used as a blood-sparing technique in total knee arthroplasty (TKA), and is routinely administered by intravenous (IV) or intra-articular (IA) injection. Recently, a novel method of TXA administration, the combined IV and IA application of TXA, has been applied in TKA. However, the scientific evidence of combined administration of TXA in TKA is still meagre. This meta-analysis aimed to investigate the efficacy and safety of combined IV and IA TXA in patients undergoing TKA. A systematic search was carried out in PubMed, the Cochrane Clinical Trial Register (Issue12 2015), Embase, Web of Science and the Chinese Biomedical Database. Only randomised controlled trials (RCT) evaluating the efficacy and safety of combined use TXA in TKA were identified. Two authors independently identified the eligible studies, extracted data and assessed the methodological quality of included studies. Meta-analysis was conducted using Review Manager 5.3 software.Objectives
Materials and Methods
We explored the literature surrounding whether
allergy and hypersensitivity has a clinical basis for implant selection
in total knee arthroplasty (TKA). In error, the terms hypersensitivity
and allergy are often used synonymously. Although a relationship
is present, we could not find any evidence of implant failure due
to allergy. There is however increasing basic science that suggests
a link between loosening and metal ion production. This is not an
allergic response but is a potential problem. With a lack of evidence
logically there can be no justification to use ‘hypoallergenic’
implants in patients who have pre-existing skin sensitivity to the
metals used in TKA. Cite this article:
Our aim was to perform a meta-analysis of the outcomes of revision
anterior cruciate ligament (ACL) reconstruction, comparing the use
of different types of graft. A search was performed of Medline and Pubmed using the terms
“Anterior Cruciate Ligament” and “ACL” combined with “revision”,
“re-operation” and “failure”. Only studies that reported the outcome
at a minimum follow-up of two years were included. Two authors reviewed
the papers, and outcomes were subdivided into autograft and allograft. Autograft
was subdivided into hamstring (HS) and bone-patellar tendon-bone
(BPTB). Subjective and objective outcome measures were analysed
and odds ratios with confidence intervals were calculated.Aims
Materials and Methods
The December 2014 Hip &
Pelvis Roundup360 looks at: Sports and total hips; topical tranexamic acid and blood conservation in hip replacement; blind spots and biases in hip research; no recurrence in cam lesions at two years; to drain or not to drain?; sonication and diagnosis of implant associated infection; and biomarkers and periprosthetic infection
Prophylactic antibiotics can decrease the risk
of wound infection and have been routinely employed in orthopaedic surgery
for decades. Despite their widespread use, questions still surround
the selection of antibiotics for prophylaxis, timing and duration
of administration. The health economic costs associated with wound
infections are significant, and the judicious but appropriate use
of antibiotics can reduce this risk. This review examines the evidence behind commonly debated topics
in antibiotic prophylaxis and highlights the uses and advantages
of some commonly used antibiotics. Cite this article: