Advertisement for orthosearch.org.uk
Results 221 - 240 of 1073
Results per page:
Bone & Joint 360
Vol. 11, Issue 2 | Pages 37 - 41
1 Apr 2022


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims

The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture.

Methods

All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT.


Bone & Joint Research
Vol. 11, Issue 5 | Pages 270 - 277
6 May 2022
Takegami Y Seki T Osawa Y Imagama S

Aims

Periprosthetic hip fractures (PPFs) after total hip arthroplasty are difficult to treat. Therefore, it is important to identify modifiable risk factors such as stem selection to reduce the occurrence of PPFs. This study aimed to clarify differences in fracture torque, surface strain, and fracture type analysis between three different types of cemented stems.

Methods

We conducted biomechanical testing of bone analogues using six cemented stems of three different types: collarless polished tapered (CPT) stem, Versys Advocate (Versys) stem, and Charnley-Marcel-Kerboull (CMK) stem. Experienced surgeons implanted each of these types of stems into six bone analogues, and the analogues were compressed and internally rotated until failure. Torque to fracture and fracture type were recorded. We also measured surface strain distribution using triaxial rosettes.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 577 - 582
1 May 2009
Duncan WW Hubble MJW Howell JR Whitehouse SL Timperley AJ Gie GA

The removal of well-fixed bone cement from the femoral canal during revision of a total hip replacement (THR) can be difficult and risks the loss of excessive bone stock and perforation or fracture of the femoral shaft. Retaining the cement mantle is attractive, yet the technique of cement-in-cement revision is not widely practised. We have used this procedure at our hospital since 1989. The stems were removed to gain a better exposure for acetabular revision, to alter version or leg length, or for component incompatibility. We studied 136 hips in 134 patients and followed them up for a mean of eight years (5 to 15). A further revision was required in 35 hips (25.7%), for acetabular loosening in 26 (19.1%), sepsis in four, instability in three, femoral fracture in one and stem fracture in one. No femoral stem needed to be re-revised for aseptic loosening. A cement-in-cement revision of the femoral stem is a reliable technique in the medium term. It also reduces the risk of perforation or fracture of the femoral shaft


Bone & Joint Open
Vol. 3, Issue 5 | Pages 383 - 389
1 May 2022
Motesharei A Batailler C De Massari D Vincent G Chen AF Lustig S

Aims

No predictive model has been published to forecast operating time for total knee arthroplasty (TKA). The aims of this study were to design and validate a predictive model to estimate operating time for robotic-assisted TKA based on demographic data, and evaluate the added predictive power of CT scan-based predictors and their impact on the accuracy of the predictive model.

Methods

A retrospective study was conducted on 1,061 TKAs performed from January 2016 to December 2019 with an image-based robotic-assisted system. Demographic data included age, sex, height, and weight. The femoral and tibial mechanical axis and the osteophyte volume were calculated from CT scans. These inputs were used to develop a predictive model aimed to predict operating time based on demographic data only, and demographic and 3D patient anatomy data.


Bone & Joint Research
Vol. 11, Issue 7 | Pages 465 - 476
13 Jul 2022
Li MCM Chow SK Wong RMY Chen B Cheng JCY Qin L Cheung W

Aims

There is an increasing concern of osteoporotic fractures in the ageing population. Low-magnitude high-frequency vibration (LMHFV) was shown to significantly enhance osteoporotic fracture healing through alteration of osteocyte lacuno-canalicular network (LCN). Dentin matrix protein 1 (DMP1) in osteocytes is known to be responsible for maintaining the LCN and mineralization. This study aimed to investigate the role of osteocyte-specific DMP1 during osteoporotic fracture healing augmented by LMHFV.

Methods

A metaphyseal fracture was created in the distal femur of ovariectomy-induced osteoporotic Sprague Dawley rats. Rats were randomized to five different groups: 1) DMP1 knockdown (KD), 2) DMP1 KD + vibration (VT), 3) Scramble + VT, 4) VT, and 5) control (CT), where KD was performed by injection of short hairpin RNA (shRNA) into marrow cavity; vibration treatment was conducted at 35 Hz, 0.3 g; 20 minutes/day, five days/week). Assessments included radiography, micro-CT, dynamic histomorphometry and immunohistochemistry on DMP1, sclerostin, E11, and fibroblast growth factor 23 (FGF23). In vitro, murine long bone osteocyte-Y4 (MLO-Y4) osteocyte-like cells were randomized as in vivo groupings. DMP1 KD was performed by transfecting cells with shRNA plasmid. Assessments included immunocytochemistry on osteocyte-specific markers as above, and mineralized nodule staining.


Bone & Joint Open
Vol. 3, Issue 6 | Pages 470 - 474
7 Jun 2022
Baek J Lee SC Ryu S Kim J Nam CH

Aims

The purpose of this study was to compare the clinical outcomes, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with or without hepatitis B virus (HBV) infection over at least ten years of follow-up.

Methods

From January 2008 to December 2010, 266 TKAs were performed in 169 patients with HBV (HBV group). A total of 169 propensity score–matched patients without HBV were chosen for the control group in a one-to-one ratio. Then, the clinical outcomes, mortalities, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 11.7 years (10.5 to 13.4) in the HBV group and 11.8 years (11.5 to 12.4) in the control group.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1274 - 1281
1 Sep 2014
Farhang K Desai R Wilber JH Cooperman DR Liu RW

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined. . The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded. The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (. sd. 4.0) and 4.6 mm (. sd. 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (. sd. 4.6) and 6.4 mm (. sd. 4.6), respectively. Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset. Cite this article: Bone Joint J 2014;96-B:1274–81


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 395 - 400
1 May 1994
Keating J Kuo R Court-Brown C

We report the results of a three-year study of bifocal fractures of the tibia and fibula, excluding segmental shaft fractures. In our whole series, these formed 4.7% of all tibial diaphyseal fractures. We describe three groups: bifocal fractures of both the proximal and the distal joint surfaces, fractures of the shaft and tibial plateau, and fractures of the shaft and ankle. These groups of fractures had different characteristics and prognoses. We discuss treatment protocols for each of these three groups


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 703 - 708
1 Jun 2022
Najefi A Zaidi R Chan O Hester T Kavarthapu V

Aims

Surgical reconstruction of deformed Charcot feet carries a high risk of nonunion, metalwork failure, and deformity recurrence. The primary aim of this study was to identify the factors contributing to these complications following hindfoot Charcot reconstructions.

Methods

We retrospectively analyzed patients who underwent hindfoot Charcot reconstruction with an intramedullary nail between January 2007 and December 2019 in our unit. Patient demographic details, comorbidities, weightbearing status, and postoperative complications were noted. Metalwork breakage, nonunion, deformity recurrence, concurrent midfoot reconstruction, and the measurements related to intramedullary nail were also recorded.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 30 - 32
1 Oct 2014

The October 2014 Children’s orthopaedics Roundup. 360 . looks at: spondylolisthesis management strategies; not all cervical collars are even; quality of life with Legg-Calve-Perthe’s disease; femoral shaft fractures in children; percutaneous trigger thumb release – avoid at all costs in children; predicting repeat surgical intervention in acute osteomyelitis; and C-Arm position inconsequential in radiation exposure


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 401 - 407
1 Mar 2022
Kriechling P Zaleski M Loucas R Loucas M Fleischmann M Wieser K

Aims

The aim of this study was to report the incidence of implant-related complications, further operations, and their influence on the outcome in a series of patients who underwent primary reverse total shoulder arthroplasty (RTSA).

Methods

The prospectively collected clinical and radiological data of 797 patients who underwent 854 primary RTSAs between January 2005 and August 2018 were analyzed. The hypothesis was that the presence of complications would adversely affect the outcome. Further procedures were defined as all necessary operations, including reoperations without change of components, and partial or total revisions. The clinical outcome was evaluated using the absolute and relative Constant Scores (aCS, rCS), the Subjective Shoulder Value (SSV) scores, range of motion, and pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 23 - 25
1 Jan 1990
Sojbjerg J Eiskjaer S Moller-Larsen F

Forty comminuted or unstable fractures of the femoral shaft were treated by closed intramedullary reaming and locked nailing. Twenty-four fractures were severely comminuted, and the other 16, in the distal or proximal third of the shaft, were classified as unstable. At 12 to 30 months postoperatively all the fractures had healed. Three patients had lateral rotation deformity of 5 degrees to 10 degrees, three had shortening of 1 to 2 cm and two had lengthening of about 1 cm. There were no infections or delayed unions. Closed intramedullary locked nailing can provide stability in fractures of the femoral shaft, irrespective of the degree of comminution and the site of injury


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1370 - 1377
1 Oct 2014
Connelly CL Bucknall V Jenkins PJ Court-Brown CM McQueen MM Biant LC

Fractures of the tibial shaft are common injuries, but there are no long-term outcome data in the era of increased surgical management. The aim of this prospective study was to assess the clinical and functional outcome of this injury at 12 to 22 years. Secondary aims were to determine the short- and long-term mortality, and if there were any predictors of clinical or functional outcome or mortality. From a prospective trauma database of 1502 tibial shaft fractures in 1474 consecutive adult patients, we identified a cohort of 1431 tibial diaphyseal fractures in 1403 patients, who fitted our inclusion criteria. There were 1024 men, and mean age at injury was 40.6 years. Fractures were classified according to the AO system, and open fractures graded after Gustilo and Anderson. Requirement of fasciotomy, time to fracture union, complications, incidence of knee and ankle pain at long-term follow-up, changes in employment and the patients’ social deprivation status were recorded. Function was assessed at 12 to 22 years post-injury using the Short Musculoskeletal Function Assessment and short form-12 questionnaires. Long-term functional outcome data was available for 568 of the surviving patients, 389 were deceased and 346 were lost to follow-up. Most fractures (90.7%, n = 1363) united without further intervention. Fasciotomies were performed in 11.5% of patients; this did not correlate with poorer functional outcome in the long term. Social deprivation was associated with a higher incidence of injury but had no impact on long-term function. The one-year mortality in those over 75 years of age was 29 (42%). At long-term follow-up, pain and function scores were good. However, 147 (26%) reported ongoing knee pain, 62 (10%) reported ankle pain and 97 (17%) reported both. Such joint pain correlated with poorer functional outcome. Cite this article: Bone Joint J 2014;96-B:1370–7


Bone & Joint Research
Vol. 11, Issue 5 | Pages 304 - 316
17 May 2022
Kim MH Choi LY Chung JY Kim E Yang WM

Aims

The association of auraptene (AUR), a 7-geranyloxycoumarin, on osteoporosis and its potential pathway was predicted by network pharmacology and confirmed in experimental osteoporotic mice.

Methods

The network of AUR was constructed and a potential pathway predicted by Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway and Gene Ontology (GO) terms enrichment. Female ovariectomized (OVX) Institute of Cancer Research mice were intraperitoneally injected with 0.01, 0.1, and 1 mM AUR for four weeks. The bone mineral density (BMD) level was measured by dual-energy X-ray absorptiometry. The bone microstructure was determined by histomorphological changes in the femora. In addition, biochemical analysis of the serum and assessment of the messenger RNA (mRNA) levels of osteoclastic markers were performed.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 83 - 90
1 Jan 2022
Batten TJ Gallacher S Evans JP Harding RJ Kitson J Smith CD Thomas WJ

Aims

The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up.

Methods

Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening.


Bone & Joint Open
Vol. 3, Issue 5 | Pages 359 - 366
1 May 2022
Sadekar V Watts AT Moulder E Souroullas P Hadland Y Barron E Muir R Sharma HK

Aims

The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors.

Methods

We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 4 | Pages 548 - 561
1 Nov 1951
Evans EM

An attempt has been made to describe some of the ways in which the element of rotation, which is so important a part of the function of the normal forearm, has a bearing upon the mechanism and treatment of forearm injuries. In particular, distinction is drawn between those injuries in which the shaft of the radius remains in continuity, and those in which there is a complete fracture of the bone. In the former, rotation of the hand in the reduction will be transmitted to the upper end of the radius, and extremes of rotational movement may safely be used to obtain and hold a reduction. In the latter there is likely to be a rotational deformity between the two radial fragments, and the lower radial fragment must be placed in accurate rotational alignment with the upper. In the first group reduction, and in certain cases immobilisation, in full pronation or full supination has been shown to have a place in the treatment of those cases in which a rotation violence has shaped the pattern of the injury. Soft tissues may be used to guide and hold a reduction in a rotational injury, just as in injuries of other types. An injury caused by forced pronation should logically be treated in full supination, for only thus are the intact soft tissues on the "pronation side" of the limb used to the best advantage. In the mechanism of injuries caused by rotation violence it is emphasized that vertical compression is usually the basic force, to which a rotation force may be added by the direction of momentum of the body weight. Such injuries may be grouped into forced rotation injuries (in which the violence applied has taken the limb beyond the normal ranges of rotational movement), and injuries occurring while the limb is pronating or supinating. In the latter group the rotational element determines the pattern of the injury: pronation and flexion are closely allied, and a fracture occurring while the forearm is pronating will develop a backward angulation: so also a supination injury will produce a forward angulation. On the basis of these considerations injuries of the forearm may be classified as follows:. Injuries in which the shaft of the radius remains in continuity. Forced proiiation injuries:. 1) Forward dislocation of the head of the radius. 2) Backward dislocation of the lower end of the ulna. 3) The anterior Monteggia fracture-dislocation. These injuries should be reduced and immobilised in full supination to prevent recurrence of deformity. The lateral and posterior Monteggia injuries are probably variants of dislocation of the elbow and are not caused by rotation violence. In general it is considered that all dislocations of the head of the radius are best treated in full supination. Pronation injuries:. Greenstick fractures of the radius, and of both bones of the forearm, with backward angulation. Reduction of deformity is most easily obtained by manipulating into full supination. Certain fractures may with advantage be immobilised in this position. Supination injuries:. Greenstick fractures of the forearm with forward angulation. Reduction is best obtained by full pronation. Injuries in which the shaft of the radius is in two separate fragments. This group includes all complete fractures of the shaft of the radius and of both bones of the forearm. There is nearly always a rotational deformity between the two radial fragments and its correction is a dominant factor in the treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 3 | Pages 393 - 397
1 Aug 1964
Lam SJ

It seems right to draw the following conclusions from this study of the relative merits of early and delayed fixation for fractures of the femoral and tibial shafts. 1. In patients under the age of sixty years with femoral shaft fractures there seems to be a significant improvement in the speed and quality of union when internal fixation is delayed. In patients over the age of sixty years the results of delayed fixation are worse than those of early fixation, and in any case the dangers of prolonged recumbency make the latter method preferable. 2. Delaying fixation for tibial shaft fractures does not affect speed of union or functional result. However, the incidence of non-union in these fractures is reduced by over 50 per cent by delaying fixation. This is a good reason for delaying fixation of this fracture too. Some possible reasons for the improved results after delayed fixation have been discussed