The outcome of high tibial osteotomy (HTO) deteriorates
with time, and additional procedures may be required. The aim of
this study was to compare the clinical and radiological outcomes
between unicompartmental knee replacement (UKR) and total knee replacement
(TKR) after HTO as well as after primary UKR. A total of 63 patients (63
knees) were studied retrospectively and divided into three groups:
UKR after HTO (group A; n = 22), TKR after HTO (group B; n = 18)
and primary UKR (group C; n = 22). The Oxford knee score (OKS),
Knee Society score (KSS), hip–knee–ankle angles, mechanical axis
and patellar height were evaluated pre- and post-operatively. At
a mean of 64 months (19 to 180) post-operatively the mean OKS was
43.8 (33 to 49), 43.3 (30 to 48) and 42.5 (29 to 48) for groups
A, B and C, respectively (p = 0.73). The mean KSS knee score was
88.8 (54 to 100), 88.11 (51 to 100) and 85.3 (45 to 100) for groups
A, B and C, respectively (p = 0.65), and the mean KSS function score
was 85.0 (50 to 100) in group A, 85.8 (20 to 100) in group B and
79.3 (50 to 100) in group C (p = 0.48). Radiologically the results
were comparable for all groups except for patellar height, with
a higher incidence of patella infra following a previous HTO (p
= 0.02). Cite this article:
Bone mineral density (BMD) around the femoral component has been reported to decrease after total knee replacement (TKR) because of stress shielding. Our aim was to determine whether a cemented mobile-bearing component reduced the post-operative loss of BMD. In our study 28 knees receiving a cemented fixed-bearing TKR were matched with 28 receiving a cemented mobile-bearing TKR. They underwent dual-energy x-ray absorptiometry, pre-operatively and at three weeks and at three, six, 12, 18 and 24 months post-operatively. The patients were not taking medication to improve the BMD. The pre-operative differences in the BMD of the femoral neck, wrist, lumbar spine and knee in the two groups were not significant. The BMD of the femur decreased postoperatively in the fixed-bearing group, but not the mobile-bearing group. The difference in the post-operative change in the BMD in the two groups was statistically significant (p <
0.05) at 18 and 24 months. Our findings show that a cemented mobile-bearing TKR has a favourable effect on the BMD of the distal femur after TKR in the short term. Further study is required to determine the long-term effects.
In the absence of patellar resurfacing, we have
previously shown that the use of electrocautery around the margin of
the patella improved the one-year clinical outcome of total knee
replacement (TKR). In this prospective randomised study we compared
the mean 3.7 year (1.1 to 4.2) clinical outcomes of 300 TKRs performed
with and without electrocautery of the patellar rim: this is an
update of a previous report. The overall prevalence of anterior knee
pain was 32% (95% confidence intervals [CI] 26 to 39), and 26% (95%
CI 18 to 35) in the intervention group compared with 38% (95% CI
29 to 48) in the control group (chi-squared test; p = 0.06). The
overall prevalence of anterior knee pain remained unchanged between
the one-year and 3.7 year follow-up (chi-squared test; p = 0.12). The
mean total Western Ontario McMasters Universities Osteoarthritis
Indices and the American Knee Society knee and function scores at
3.7 years’ follow-up were similar in the intervention and control
groups (repeated measures analysis of variance p = 0.43, p = 0.09
and p = 0.59, respectively). There were no complications. A total
of ten patients (intervention group three, control group seven)
required secondary patellar resurfacing after the first year. Our study suggests that the improved clinical outcome with electrocautery
denervation compared with no electrocautery is not maintained at
a mean of 3.7 years’ follow-up. Cite this article:
Despite many claims of good wear properties following
total knee replacement (TKR) with an oxidised zirconium (OxZr) femoral
component, there are conflicting clinical results. We hypothesised
that there would be no difference in either the mid-term clinical
and radiological outcomes or the characteristics of the polyethylene
wear particles (weight, size and shape) in patients using an OxZr
or cobalt-chrome (CoCr) femoral component. In all 331 patients underwent
bilateral TKR, receiving an OxZr femoral component in one knee and
a CoCr femoral component in the other. The mean follow-up was 7.5
years (6 to 8). Following aspiration, polyethylene wear particles
were analysed using thermogravimetric methods and scanning electron
microscopy. At the most recent follow-up, the mean Knee Society
score, Western Ontario and McMaster Universities Osteoarthritis
Index score, range of movement and satisfaction score were not significantly
different in the two groups. The mean weight, size, aspect ratio
and roundness of the aspirated wear particles were similar for each
femoral component. Survivorship of the femoral, tibial and patellar
components was 100% in both groups. In the absence of evidence of an advantage in the medium term
we cannot justify the additional expense of an OxZr femoral component.
We prospectively followed 171 patients who underwent
bilateral unicompartmental knee replacement (UKR) over a period
of two years. Of these, 124 (72.5%) underwent a simultaneous bilateral
procedure and 47 (27.5%) underwent a staged procedure. The mean
cumulative operating time and length of hospital stay were both
shorter in the simultaneous group, by 22.5 minutes (p <
0.001)
and three days (p <
0.001), respectively. The mean reduction
in haemoglobin level post-operatively was greater by 0.15 g/dl in
the simultaneous group (p = 0.023), but this did not translate into
a significant increase in the number of patients requiring blood
transfusion (p = 1.000). The mean hospital cost was lower by $8892
in the simultaneous group (p <
0.001). There was no significant
difference in the rate of complications between the groups, and
at two-year follow-up there was no difference in the outcomes between
the two groups. We conclude that simultaneous bilateral UKR can be recommended
as an appropriate treatment for patients with bilateral medial compartment
osteoarthritis of the knee. Cite this article:
Radiological evidence of post-traumatic osteoarthritis
(PTOA) after fracture of the tibial plateau is common but end-stage arthritis
which requires total knee arthroplasty is much rarer. The aim of this study was to examine the indications for, and
outcomes of, total knee arthroplasty after fracture of the tibial
plateau and to compare this with an age and gender-matched cohort
of TKAs carried out for primary osteoarthritis. Between 1997 and 2011, 31 consecutive patients (23 women, eight
men) with a mean age of 65 years (40 to 89) underwent TKA at a mean
of 24 months (2 to 124) after a fracture of the tibial plateau.
Of these, 24 had undergone ORIF and seven had been treated non-operatively.
Patients were assessed pre-operatively and at 6, 12 and >
60 months
using the Short Form-12, Oxford Knee Score and a patient satisfaction
score. Patients with instability or nonunion needed total knee arthroplasty
earlier (14 and 13.3 months post-injury) than those with intra-articular
malunion (50 months, p <
0.001). Primary cruciate-retaining implants
were used in 27 (87%) patients. Complication rates were higher in
the PTOA cohort and included wound complications (13% Total knee arthroplasty undertaken after fracture of the tibial
plateau has a higher rate of complications than that undertaken
for primary osteoarthritis, but patient-reported outcomes and satisfaction
are comparable. Cite this article:
This prospective study compares the outcome of
157 hydroxyapatite (HA)-coated tibial components with 164 cemented
components in the ROCC Rotating Platform total knee replacement
in 291 patients. The mean follow-up was 7.6 years (5.2 to 11). There
were two revisions for loosening: one for an HA-coated and one for
a cemented tibial component. Radiological evaluation demonstrated
no radiolucent lines with the HA-coated femoral components. A total
of three HA-coated tibial components exhibited radiolucent lines
at three months post-operatively and these disappeared after three
further months of protected weight-bearing. With HA-coated components
the operating time was shorter (p <
0.006) and the radiological
assessment of the tibial interface was more stable (p <
0.01).
Using revision for aseptic loosening of the tibial component as
the end point, the survival rates at nine years was identical for
both groups at 99.1%. Our results suggest that HA-coated components perform at least
as well as the same design with cemented components and compare
favourably with those of series describing cemented or porous-coated
knee replacements, suggesting that fixation of both components with
hydroxyapatite is a reliable option in primary total knee replacement.
Total knee arthroplasty (TKA) is an established
and successful procedure. However, the design of prostheses continues
to be modified in an attempt to optimise the functional outcome
of the patient. The aim of this study was to determine if patient outcome after
TKA was influenced by the design of the prosthesis used. A total of 212 patients (mean age 69; 43 to 92; 131 female (62%),
81 male (32%)) were enrolled in a single centre double-blind trial
and randomised to receive either a Kinemax (group 1) or a Triathlon
(group 2) TKA. Patients were assessed pre-operatively, at six weeks, six months,
one year and three years after surgery. The outcome assessments
used were the Oxford Knee Score; range of movement; pain numerical
rating scales; lower limb power output; timed functional assessment
battery and a satisfaction survey. Data were assessed incorporating
change over all assessment time points, using repeated measures
analysis of variance longitudinal mixed models. Implant group 2
showed a significantly greater range of movement (p = 0.009), greater
lower limb power output (p = 0.026) and reduced report of ‘worst
daily pain’ (p = 0.003) over the three years of follow-up. Differences
in Oxford Knee Score (p = 0.09), report of ‘average daily pain’
(p = 0.57) and timed functional performance tasks (p = 0.23) did
not reach statistical significance. Satisfaction with outcome was
significantly better in group 2 (p = 0.001). These results suggest that patient outcome after TKA can be influenced
by the prosthesis used. Cite this article:
The February 2013 Knee Roundup360 looks at: mobile-bearing TKRs; arthroscopic ACL reconstruction; the use of chondrocytes for osteochondral defects; ACL reconstruction and the return to pivoting sports; ACLs and the MOON study; the benefit of knee navigation; and trabecular metal.
Intra-articular resection of bone with soft-tissue balancing and total knee replacement (TKR) has been described for the treatment of patients with severe osteoarthritis of the knee associated with an ipsilateral malunited femoral fracture. However, the extent to which deformity in the sagittal plane can be corrected has not been addressed. We treated 12 patients with severe arthritis of the knee and an extra-articular malunion of the femur by TKR with intra-articular resection of bone and soft-tissue balancing. The femora had a mean varus deformity of 16° (8° to 23°) in the coronal plane. There were seven recurvatum deformities with a mean angulation of 11° (6° to 15°) and five antecurvatum deformities with a mean angulation of 12° (6° to 15°). The mean follow-up was 93 months (30 to 155). The median Knee Society knee and function scores improved from 18.7 (0 to 49) and 24.5 (10 to 50) points pre-operatively to 93 (83 to 100) and 90 (70 to 100) points at the time of the last follow-up, respectively. The mean mechanical axis of the knee improved from 22.6° of varus (15° to 27° pre-operatively to 1.5° of varus (3° of varus to 2° of valgus) at the last follow-up. The recurvatum deformities improved from a mean of 11° (6° to 15°) pre-operatively to 3° (0° to 6°) at the last follow-up. The antecurvatum deformities in the sagittal plane improved from a mean of 12° (6° to 16°) pre-operatively to 4.4° (0° to 8°) at the last follow-up. Apart from varus deformities, TKR with intra-articular bone resection effectively corrected the extra-articular deformity of the femur in the presence of antecurvatum of up to 16° and recurvatum of up to 15°.
The October 2013 Knee Roundup360 looks at: Make it easy, release the MCL; Do patients remember clinical information in day surgery?; Osteoarthritis and arthroscopy?; How best to double your bundles; When to operate for infection; Cementless unicompartment knee replacement?; Tibial tubercle-trochlear groove confusion; Tarts, cherries and osteoarthritis
We have examined the differences in clinical outcome of total knee replacement (TKR) with and without patellar resurfacing in a prospective, randomised study of 181 osteoarthritic knees in 142 patients using the Profix total knee system which has a femoral component with features considered to be anatomical and a domed patellar implant. The procedures were carried out between February 1998 and November 2002. A total of 159 TKRs in 142 patients were available for review at a mean of four years (3 to 7). The patients and the clinical evaluator were blinded in this prospective study. Evaluation was undertaken annually by an independent observer using the knee pain scale and the Knee Society clinical rating system. Specific evaluation of anterior knee pain, stair-climbing and rising from a seated to a standing position was also undertaken. No benefit was shown of TKR with patellar resurfacing over that without resurfacing with respect to any of the measured outcomes. In 22 of 73 knees (30.1%) with and 18 of 86 knees (20.9%) without patellar resurfacing there was some degree of anterior knee pain (p = 0.183). No revisions related to the patellofemoral joint were performed in either group. Only one TKR in each group underwent a re-operation related to the patellofemoral joint. A significant association between knee flexion contracture and anterior knee pain was observed in those knees with patellar resurfacing (p = 0.006).
Patients with skeletal dysplasia are prone to
developing advanced osteoarthritis of the knee requiring total knee replacement
(TKR) at a younger age than the general population. TKR in this
unique group of patients is a technically demanding procedure owing
to the deformity, flexion contracture, generalised hypotonia and ligamentous
laxity. We retrospectively reviewed the outcome of 11 TKRs performed
in eight patients with skeletal dysplasia at our institution using
the Stanmore Modular Individualised Lower Extremity System (SMILES)
custom-made rotating-hinge TKR. There were three men and five women
with mean age of 57 years (41 to 79). Patients were followed clinically
and radiologically for a mean of seven years (3 to 11.5). The mean
Knee Society clinical and function scores improved from 24 (14 to
36) and 20 (5 to 40) pre-operatively, respectively, to 68 (28 to
80) and 50 (22 to 74), respectively, at final follow-up. Four complications
were recorded, including a patellar fracture following a fall, a
tibial peri-prosthetic fracture, persistent anterior knee pain,
and aseptic loosening of a femoral component requiring revision.
Our results demonstrate that custom primary rotating-hinge TKR in
patients with skeletal dysplasia is effective at relieving pain,
with a satisfactory range of movement and improved function. It compensates
for bony deformity and ligament deficiency and reduces the likelihood
of corrective osteotomy. Patellofemoral joint complications are
frequent and functional outcome is worse than with primary TKR in
the general population.
We present a comparison of patient-reported outcomes
(PROMs) in relation to patient age, in patients who had received
a total (TKR) or unicompartmental knee replacement (UKR). The outcome
was evaluated using the Oxford knee score (OKS), EuroQol (EQ-5D)
and satisfaction scores. Patients aged 65 to 84 years demonstrated
better pre-operative function scores than those aged <
65 years
(OKS, p = 0.03; EQ-5D, p = 0.048) and those aged
≥ 85 years (OKS, p = 0.03). Post-operative scores were comparable
across age groups, but a linear trend for greater post-operative
improvement in OKS and EQ-5D was seen with decreasing age (p <
0.033). The overall mean satisfaction score at six months was 84.9,
but those aged <
55 years exhibited a lower mean level of satisfaction (78.3)
compared with all other age groups (all p <
0.031). The cumulative
overall two-year revision rate was 1.3%. This study demonstrates
that good early outcomes, as measured by the OKS and EQ-5D, can
be anticipated following knee replacement regardless of the patient’s
age, although younger patients gain greater improvement. However,
the lower satisfaction in those aged
<
55 years is a concern, and suggests that outcome is not fully
encapsulated by the OKS and EQ-5D evaluation, and raises the question
whether the OKS alone is an appropriate measure of pain and function
in younger, more active individuals. Cite this article:
A total of 445 consecutive primary total knee
replacements (TKRs) were followed up prospectively at six and 18 months
and three, six and nine years. Patients were divided into two groups:
non-obese (body mass index (BMI) <
30 kg/m2) and obese
(BMI ≥ 30 kg/m2). The obese group was subdivided into
mildly obese (BMI 30 to 35 kg/m2) and highly obese (BMI ≥ 35
kg/m2) in order to determine the effects of increasing
obesity on outcome. The clinical data analysed included the Knee
Society score, peri-operative complications and implant survival.
There was no difference in the overall complication rates or implant
survival between the two groups. Obesity appears to have a small but significant adverse effect
on clinical outcome, with highly obese patients showing lower function
scores than non-obese patients. However, significant improvements
in outcome are sustained in all groups nine years after TKR. Given
the substantial, sustainable relief of symptoms after TKR and the low
peri-operative complication and revision rates in these two groups,
we have found no reason to limit access to TKR in obese patients.
Substantial healthcare resources have been devoted
to computer navigation and patient-specific instrumentation systems
that improve the reproducibility with which neutral mechanical alignment
can be achieved following total knee replacement (TKR). This choice of
alignment is based on the long-held tenet that the alignment of
the limb post-operatively should be within 3° of a neutral mechanical
axis. Several recent studies have demonstrated no significant difference
in survivorship when comparing well aligned Review of the literature suggests that a neutral mechanical axis
remains the optimal guide to alignment. Cite this article:
We retrospectively reviewed 30 patients with
a diffuse-type giant-cell tumour (Dt-GCT) (previously known as pigmented
villonodular synovitis) around the knee in order to assess the influence
of the type of surgery on the functional outcome and quality of
life (QOL). Between 1980 and 2001, 15 of these tumours had been
treated primarily at our tertiary referral centre and 15 had been
referred from elsewhere with recurrent lesions. The mean follow-up was 64 months (24 to 393). Functional outcome
and QOL were assessed with range of movement and the Knee injury
and Osteoarthritis Outcome Score (KOOS), the Musculoskeletal Tumour
Society (MSTS) score, the Toronto Extremity Salvage Score (TESS)
and the SF-36 questionnaire. There was recurrence in four of 14
patients treated initially by open synovectomy. Local control was
achieved after a second operation in 13 of 14 (93%). Recurrence
occurred in 15 of 16 patients treated initially by arthroscopic
synovectomy. These patients underwent a mean of 1.8 arthroscopies
(one to eight) before open synovectomy. This achieved local control
in 8 of 15 (53%) after the first synovectomy and in 12 of 15 (80%)
after two. The functional outcome and QOL of patients who had undergone
primary arthroscopic synovectomy and its attendant subsequent surgical
procedures were compared with those who had had a primary open synovectomy
using the following measures: range of movement (114º Those who had undergone open synovectomy needed fewer subsequent
operations. Most patients who had been referred with a recurrence
had undergone an initial arthroscopic synovectomy followed by multiple
further synovectomies. At the final follow-up of eight years (2
to 32), these patients had impaired function and QOL compared with
those who had undergone open synovectomy initially. We conclude that the natural history of Dt-GCT in patients who
are treated by arthroscopic synovectomy has an unfavourable outcome,
and that primary open synovectomy should be undertaken to prevent
recurrence or residual disease. Cite this article:
Patellofemoral joint degeneration is often considered a contraindication to medial unicompartmental knee replacement. We examined the validity of this preconception using information gathered prospectively on the intra-operative status of the patellofemoral joint in 824 knees in 793 consecutive patients who underwent Oxford unicondylar knee replacement for anteromedial osteoarthritis. All operations were performed between January 1998 and September 2005. A five-point grading system classified degeneration of the patellofemoral joint from none to full-thickness cartilage loss. A subclassification of the presence or absence of any full-thickness cartilage loss was subsequently performed to test selected hypotheses. Outcome was evaluated independently by physiotherapists using the Oxford and the American Knee Society Scores with a minimum follow-up of one year. Full-thickness cartilage loss on the trochlear surface was observed in 100 of 785 knees (13%), on the medial facet of the patella in 69 of 782 knees (9%) and on the lateral facet in 29 of 784 knees (4%). Full-thickness cartilage loss at any location was seen in 128 knees (16%) and did not produce a significantly worse outcome than those with a normal or near-normal joint surface. The severity of the degeneration at any of the intra-articular locations also had no influence on outcome. We concluded that, provided there is not bone loss and grooving of the lateral facet, damage to the articular cartilage of the patellofemoral joint to the extent of full-thickness cartilage loss is not a contraindication to the Oxford mobile-bearing unicompartmental knee replacement.
Bone defects are occasionally encountered during
primary total knee replacement (TKR) and cause difficulty in establishing
a stable well-aligned bone-implant interface. Between March 1999
and November 2005, 59 knees in 43 patients underwent primary TKR
with a metal block augmentation for tibial bone deficiency. In all,
six patients (eight knees) died less than four years post-operatively,
and four patients (five knees) were lost to follow-up leaving 46 knees
in 33 patients available for review at a mean of 78.6 months (62
to 129). The clinical results obtained, including range of movement,
American Knee Society and Oxford knee scores, and the Western Ontario
and McMaster Universities osteoarthritis index, were good to excellent,
with no failures. Radiolucent lines at the block-cement-bone interface
were noted in five knees (11%) during the first post-operative year,
but these did not progress. Modular rectangular metal augmentation for tibial bone deficiency
is a useful option. No deterioration of the block-prosthesis or
block-cement-bone interface was seen at minimum of five years follow-up.
Between 2003 and 2007, 99 knees in 77 patients
underwent opening wedge high tibial osteotomy. We evaluated the effect
of initial stable fixation combined with an artificial bone substitute
on the mid- to long-term outcome after medial opening-wedge high
tibial osteotomy (HTO) for medial compartmental osteoarthritis or
spontaneous osteonecrosis of the knee in 78 knees in 64 patients
available for review at a minimum of five years (mean age 68 years;
49 to 82). The mean follow-up was 6.5 years (5 to 10). The mean
Knee