There have been few reports regarding the efficacy
of posterior instrumentation alone as surgical treatment for patients
with pyogenic spondylitis, thus avoiding the morbidity of anterior
surgery. We report the clinical outcomes of six patients with pyogenic
spondylitis treated effectively with a single-stage posterior fusion
without anterior debridement at a mean follow-up of 2.8 years (2
to 5). Haematological data, including white cell count and level
of C-reactive protein, returned to normal in all patients at a mean
of 8.2 weeks (7 to 9) after the posterior fusion. Rigid bony fusion
between the infected vertebrae was observed in five patients at
a mean of 6.3 months (4.5 to 8) post-operatively, with the remaining
patient having partial union. Severe back pain was immediately reduced
following surgery and the activities of daily living showed a marked
improvement. Methicillin-resistant Single-stage posterior fusion may be effective in patients with
pyogenic spondylitis who have relatively minor bony destruction.
We reviewed 1039 revision total hip replacements where an angle-bore acetabular component was used. After a mean follow-up of nine years (0 to 20.6), the incidence of revision for dislocation was 2.1% (22 revisions), a success rate of 97.9%. In 974 revisions, where the indication was other than dislocation, the success rate was 98.5%. Of the 65 revisions for dislocation, 58 (89.2%) were successful after the first revision and a further five after the second revision, an overall success of 96.9%. Two patients elected to have their implants removed. Dislocation after revision of failed total hip replacement is a complex issue. There is often no single cause and no simple solution. The angle-bore acetabular component, in combination with a 22.225-mm diameter femoral head, offers a high level of success.
The June 2012 Wrist &
Hand Roundup360 looks at; radial osteotomy and advanced Kienböck's disease; fixing the Bennett fracture; PEEK plates and four-corner arthrodesis,;carpal tunnel release and haemodialysis; degloved digits and the reverse radial forearm flap; occupational hand injuries; trapeziometacarpal osteoarthritis; fixing the fractured metacarpal neck and pyrocarbon implants for the destroyed PIPJ.
Dislocation of the shoulder may occur during
seizures in epileptics and other patients who have convulsions. Following
the initial injury, recurrent instability is common owing to a tendency
to develop large bony abnormalities of the humeral head and glenoid
and a susceptibility to further seizures. Assessment is difficult
and diagnosis may be missed, resulting in chronic locked dislocations
with protracted morbidity. Many patients have medical comorbidities,
and successful treatment requires a multidisciplinary approach addressing
the underlying seizure disorder in addition to the shoulder pathology.
The use of bony augmentation procedures may have improved the outcomes
after surgical intervention, but currently there is no evidence-based
consensus to guide treatment. This review outlines the epidemiology
and pathoanatomy of seizure-related instability, summarising the
currently-favoured options for treatment, and their results.
The open blast fracture of the pelvis is considered
to be the most severe injury within the spectrum of battlefield trauma.
We report our experience of 29 consecutive patients who had sustained
this injury in Afghanistan between 2008 and 2010. Their median new
injury severity score (NISS) was 41 (8 to 75), and mean blood requirement
in the first 24 hours was 60.3 units (0 to 224). In addition to
their orthopaedic injury, six had an associated vascular injury, seven
had a bowel injury, 11 had a genital injury and seven had a bladder
injury. In all, eight fractures were managed definitively with external
fixation and seven required internal fixation. Of those patients
who underwent internal fixation, four required removal of metalwork
for infection. Faecal diversion was performed in nine cases. The
median length of hospital stay following emergency repatriation
to the United Kingdom was 70.5 days (5 to 357) and the mean total
operating time was 29.6 hours (5 to 187). At a mean follow-up of
20.3 months (13.2 to 29.9), 24 patients (82.8%) were able to walk
and 26 (89.7%) had clinical and radiological evidence of stability
of the pelvic ring. As a result of the increase in terrorism, injuries that were
previously confined exclusively to warfare can now occur anywhere,
with civilian surgeons who are involved in trauma care potentially
required to manage similar injuries. Our study demonstrates that
the management of this injury pattern demands huge resources and significant
multidisciplinary input. Given the nature of the soft-tissue injury,
we would advocate external fixation as the preferred management
of these fractures. With the advent of emerging wound and faecal
management techniques, we do not believe that faecal diversion is
necessary in all cases.
Scapulothoracic fusion (STF) for painful winging
of the scapula in neuromuscular disorders can provide effective pain
relief and functional improvement, but there is little information
comparing outcomes between patients with dystrophic and non-dystrophic
conditions. We performed a retrospective review of 42 STFs in 34
patients with dystrophic and non-dystrophic conditions using a multifilament
trans-scapular, subcostal cable technique supported by a dorsal
one-third semi-tubular plate. There were 16 males and 18 females
with a mean age of 30 years (15 to 75) and a mean follow-up of 5.0
years (2.0 to 10.6). The mean Oxford shoulder score improved from
20 (4 to 39) to 31 (4 to 48). Patients with non-dystrophic conditions
had lower overall functional scores but achieved greater improvements
following STF. The mean active forward elevation increased from
59° (20° to 90°) to 97° (30° to 150°), and abduction from 51° (10°
to 90°) to 83° (30° to 130°) with a greater range of movement achieved
in the dystrophic group. Revision fusion for nonunion was undertaken
in five patients at a mean time of 17 months (7 to 31) and two required
revision for fracture. There were three pneumothoraces, two rib
fractures, three pleural effusions and six nonunions. The main risk
factors for nonunion were smoking, age and previous shoulder girdle surgery. STF is a salvage procedure that can provide good patient satisfaction
in 82% of patients with both dystrophic and non-dystrophic pathologies,
but there was a relatively high failure rate (26%) when poor outcomes
were analysed. Overall function was better in patients with dystrophic
conditions which correlated with better range of movement; however,
patients with non-dystrophic conditions achieved greater functional
improvement.
This review summarises the opinions and conclusions
reached from a symposium on infected total knee replacement (TKR)
held at the British Association of Surgery of the Knee (BASK) annual
meeting in 2011. The National Joint Registry for England and Wales
reported 5082 revision TKRs in 2010, of which 1157 (23%) were caused
by infection. The diagnosis of infection beyond the acute post-operative
stage relies on the identification of the causative organism by
aspiration and analysis of material obtained at arthroscopy. Ideal
treatment then involves a two-stage surgical procedure with extensive
debridement and washout, followed by antibiotics. An articulating
or non-articulating drug-eluting cement spacer is used prior to
implantation of the revision prosthesis, guided by the serum level
of inflammatory markers. The use of a single-stage revision is gaining popularity
and we would advocate its use in certain patients where the causative
organism is known, no sinuses are present, the patient is not immunocompromised,
and there is no radiological evidence of component loosening or
osteitis. It is our opinion that single-stage revision produces high-quality
reproducible results and will soon achieve the same widespread acceptance
as it does in infected hip arthroplasty.
Although it is widely accepted that grade IIIB open tibial fractures require combined specialised orthopaedic and plastic surgery, the majority of patients in the UK initially present to local hospitals without access to specialised trauma facilities. The aim of this study was to compare the outcome of patients presenting directly to a specialist centre (primary group) with that of patients initially managed at local centres (tertiary group). We reviewed 73 consecutive grade IIIB open tibial shaft fractures with a mean follow-up of 14 months (8 to 48). There were 26 fractures in the primary and 47 in the tertiary group. The initial skeletal fixation required revision in 22 (47%) of the tertiary patients. Although there was no statistically-significant relationship between flap timing and flap failure, all the failures (6 of 63; 9.5%) occurred in the tertiary group. The overall mean time to union of 28 weeks was not influenced by the type of skeletal fixation. Deep infection occurred in 8.5% of patients, but there were no persistently infected fractures. The infection rate was not increased in those patients debrided more than six hours after injury. The limb salvage rate was 93%. The mean limb functional score was 74% of that of the normal limb. At review, 67% of patients had returned to employment, with a further 10% considering a return after rehabilitation. The times to union, infection rates and Enneking limb reconstruction scores were not statistically different between the primary and tertiary groups. The increased complications and revision surgery encountered in the tertiary group suggest that severe open tibial fractures should be referred directly to specialist centres for simultaneous combined management by orthopaedic and plastic surgeons.
We describe 261 peripheral nerve injuries sustained
in war by 100 consecutive service men and women injured in Iraq
and Afghanistan. Their mean age was 26.5 years (18.1 to 42.6), the
median interval between injury and first review was 4.2 months (mean
8.4 months (0.36 to 48.49)) and median follow-up was 28.4 months
(mean 20.5 months (1.3 to 64.2)). The nerve lesions were predominantly
focal prolonged conduction block/neurapraxia in 116 (45%), axonotmesis
in 92 (35%) and neurotmesis in 53 (20%) and were evenly distributed
between the upper and the lower limbs. Explosions accounted for
164 (63%): 213 (82%) nerve injuries were associated with open wounds.
Two or more main nerves were injured in 70 patients. The ulnar,
common peroneal and tibial nerves were most commonly injured. In
69 patients there was a vascular injury, fracture, or both at the
level of the nerve lesion. Major tissue loss was present in 50 patients:
amputation of at least one limb was needed in 18. A total of 36 patients
continued in severe neuropathic pain. This paper outlines the methods used in the assessment of these
injuries and provides information about the depth and distribution
of the nerve lesions, their associated injuries and neuropathic
pain syndromes.
The current indications for functional restoration
of extension of the knee following quadriceps resection or loss require
reappraisal. The contribution of pedicled and free functional muscle
transfer is likely to be over-emphasised in many studies, with good
functional outcomes predominantly reported only in the context of
cases with residual quadriceps function. In cases with total quadriceps
resection or loss, all forms of reconstruction perform poorly. Furthermore,
in smaller resections with loss of two or fewer components of the
quadriceps, minimal impairment of function occurs in the absence
of functional reconstruction, suggesting that functional restoration
may not be warranted. Thus there is a paradox in the current approach
to quadriceps reconstruction, in that small resections are likely
to be over-treated and large resections remain under-treated. This review suggests a shift is required in the approach and
rationale for reconstructing functional extension of the knee after
quadriceps resection or loss. A classification based on current
evidence is suggested that emphasises more clearly the indications
and rationale for functional transfers.
Radial osteotomy is currently advocated for patients
with Lichtman’s stages II and IIIA of Kienböck’s disease; its place
in the treatment of patients with stage IIIB disease remains controversial.
The purpose of this study was to evaluate the medium-term results
of this procedure and to compare the outcome in patients with stage
IIIB disease and those with earlier stages (II and IIIA). A total
of 18 patients (18 osteotomies) were evaluated both clinically and radiologically
at a mean follow-up of 10.3 years (4 to 18). Range of movement,
grip strength and pain improved significantly in all patients; the
functional score (Nakamura Scoring System (NSSK)) was high and self-reported disability
(Disabilities of Arm, Shoulder and Hand questionnaire) was low at
the final follow-up in all patients evaluated. Patients with stage
IIIB disease, however, had a significantly lower grip strength,
lower NSSK scores and higher disability than those in less advanced
stages. Radiological progression of the disease was not noted in
either group, despite the stage. Radial osteotomy seems effective
in halting the progression of disease and improving symptoms in
stages II, IIIA and IIIB. Patients with less advanced disease should
be expected to have better clinical results.
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
We report the effectiveness of revision of total
elbow replacement by re-cementing. Between 1982 and 2004, 53 elbows
in 52 patients were treated with re-cementing of a total elbow replacement
into part or all of the existing cement mantle or into the debrided
host-bone interface, without the use of structural bone augmentation
or a custom prosthesis. The original implant revision was still
We evaluated the safety and efficacy of total
knee replacement in patients receiving continuous warfarin therapy. We identified 24 consecutive patients receiving long-term warfarin
therapy who underwent total knee replacement between 2006 and 2008
and compared them with a group of age- and gender-matched patients
not on long-term anticoagulation. Primary observations were changes
in haemoglobin, transfusion rates and complications. Secondary observations
were fluctuations in the international normalised ratio (INR) and
post-operative range of movement. There was no significant difference between the two groups in
pre- or post-operative haemoglobin, incidence of transfusion or
incidence of post-operative complications. There were no surgical
delays due to a high INR level. The mean change in INR during the
peri-operative phase was minimal (mean 0.4; Current American College of Chest Physicians guidelines recommend
bridging therapy for high-risk patients receiving oral anticoagulation
and undergoing major orthopaedic procedures. We have shown that
a safe alternative is to continue the steady-state warfarin peri-operatively
in patients on long-term anticoagulation requiring total knee replacement.
We report the consensus of surgical opinions of an international faculty of expert metal-on-metal hip resurfacing surgeons, with a combined experience of over 18 000 cases, covering required experience, indications, surgical technique, rehabilitation and the management of problematic cases.
Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device. The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.
The best method of reconstruction after resection of malignant tumours of the tibial diaphysis is unknown. In the absence of any long-term studies analysing the results of intercalary endoprosthetic replacement, we present a retrospective review of 18 patients who underwent limb salvage using a tibial diaphyseal endoprosthetic replacement following excision of a malignant bone tumour. There were ten men and eight women with a mean age of 42.5 years (16 to 76). Mean follow-up was 58.5 months (20 to 141) for all patients and 69.3 months (20 to 141) for the 12 patients still alive. Cumulative patient survival was 59% (95% confidence interval (CI) 32 to 84) at five years. Implant survival was 63% (95% CI 35 to 90) at ten years. Four patients required revision to a proximal tibial replacement at a mean follow-up of 29 months (10 to 54). Complications included metastases in five patients, aseptic loosening in four, peri-prosthetic fracture in two, infection in one and local recurrence in one. The mean Musculoskeletal Tumor Society score and the mean Toronto Extremity Salvage Score were 23 (17 to 28) and 74% (53 to 91), respectively. Although rates of complication and revision were high, custom-made tibial diaphyseal replacement following resection of malignant bone tumours enables early return to function and provides an attractive alternative to other surgical options, without apparent compromise of patient survival.
Disarticulation of the hip in patients with high-grade tumours in the upper thigh results in significant morbidity. In patients with no disease of the proximal soft tissue a femoral stump may be preserved, leaving a fulcrum for movement and weight-bearing. We reviewed nine patients in whom the oncological decision would normally be to disarticulate, but who were treated by implantation of an endoprosthesis in order to create a functioning femoral stump. The surgery was undertaken for chondrosarcoma in four patients, pleomorphic sarcoma in three, osteosarcoma in one and fibrous dysplasia in one. At follow-up at a mean of 80 months (34 to 132), seven patients were alive and free from disease, one had died from lung metastases and another from a myocardial infarction. The mean functional outcome assessment was 50 (musculoskeletal tumor society), 50 and 60 (physical and mental Short-form 36 scores). Implantation of an endoprosthesis into the stump in carefully selected patients allows fitting of an above-knee prosthesis and improves wellbeing and the functional outcome.
We prospectively evaluated the long-term outcome of 158 consecutive patients who underwent revision total hip replacement using uncemented computer-assisted design-computer-assisted manufacture femoral components. There were 97 men and 61 women. Their mean age was 63.1 years (34.6 to 85.9). The mean follow-up was 10.8 years (10 to 12). The mean Oxford, Harris and Western Ontario and McMaster hip scores improved from 41.1, 44.2 and 52.4 pre-operatively to 18.2, 89.3 and 12.3, respectively (p <
0.0001, for each). Six patients required further surgery. The overall survival of the femoral component was 97% (95% confidence interval 94.5 to 99.7). These results are comparable to those of previously published reports for revision total hip replacement using either cemented or uncemented components.