Our aim was to perform a systematic review of the literature
to assess the incidence of post-operative epidural haematomas and
wound infections after one-, or two-level, non-complex, lumbar surgery
for degenerative disease in patients with, or without post-operative
wound drainage. Studies were identified from PubMed and EMBASE, up to and including
27 August 2015, for papers describing one- or two-level lumbar discectomy
and/or laminectomy for degenerative disease in adults which reported
any form of subcutaneous or subfascial drainage.Aims
Patients and Methods
The objective of this five-year prospective, blinded, randomised
controlled trial (RCT) was to compare femoral head penetration into
a vitamin E diffused highly cross-linked polyethylene (HXLPE) liner
with penetration into a medium cross-linked polyethylene control
liner using radiostereometric analysis. Patients scheduled for total hip arthroplasty (THA) were randomised
to receive either the study E1 (32 patients) or the control ArComXL
polyethylene (35 patients). The median age (range) of the overall
cohort was 66 years (40 to 76).Aims
Patients and Methods
The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.Objectives
Patients and Methods
Modular or custom-made femoral components have been preferred
for total hip arthroplasty (THA) in patients with a history of Perthes’
disease because of the distortion in the anatomy of the proximal
femur. However, it has not been established whether a monobloc cementless
stem will fit the distorted proximal femur or whether the results
of the procedure are satisfactory in this group of patients. We reviewed 68 consecutive patients who had undergone THA for
childhood Perthes’ disease between June 2003 and December 2008.
There were 35 men and 33 women with a mean age of 48 years (16 to
73) at the time of index arthroplasty. Their mean body mass index
was 24.4 (18.3 to 32.9). Of the 68 hips, 32 were classified as Stulberg
class III and 36 as class IV. The mean pre-operative shortening
of the affected leg was 17.2 mm (5 to 34). The minimum follow-up
was five years (mean 8.5 years; 5.2 to 10).Aims
Patients and Methods
Our aim was to determine whether, based on the current literature,
bariatric surgery prior to total hip (THA) or total knee arthroplasty
(TKA) reduces the complication rates and improves the outcome following
arthroplasty in obese patients. A systematic literature search was undertaken of published and
unpublished databases on the 5 November 2015. All papers reporting
studies comparing obese patients who had undergone bariatric surgery
prior to arthroplasty, or not, were included. Each study was assessed
using the Downs and Black appraisal tool. A meta-analysis of risk ratios
(RR) and 95% confidence intervals (CI) was performed to determine
the incidence of complications including wound infection, deep vein
thrombosis (DVT), pulmonary embolism (PE), revision surgery and
mortality.Aims
Methods
We evaluated the short-term functional outcome and prevalence
of bearing-specific generation of audible noise in 301 patients
(336 hips) operated on with fourth generation (Delta) medium diameter
head, ceramic-on-ceramic (CoC) total hip arthroplasties (THAs). There were 191 female (63%) and 110 male patients (37%) with
a mean age of 61 years (29 to 78) and mean follow-up of 2.1 years
(1.3 to 3.4). Patients completed three questionnaires: Oxford Hip
Score (OHS), Research and Development 36-item health survey (RAND-36)
and a noise-specific symptom questionnaire. Plain radiographs were also
analysed. A total of three hips (0.9%) were revised. Aims
Patients and Methods
Our aim was to examine the clinical and radiographic outcomes
in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs)
(238 patients), five years post-operatively. A retrospective evaluation was undertaken of patients treated
between April 2008 and October 2010 in a regional centre by two
non-designing surgeons with no previous experience of UKAs. The
Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned
radiographs were assessed post-operatively at one and five years.Aims
Patients and Methods
We performed a retrospective, comparative study of elderly patients
with an increased risk from anaesthesia who had undergone either
anterior screw fixation (ASF) or halo vest immobilisation (HVI)
for a type II odontoid fracture. A total of 80 patients aged 65 years or more who had undergone
either ASF or HVI for a type II odontoid fracture between 1988 and
2013 were reviewed. There were 47 women and 33 men with a mean age
of 73 (65 to 96; standard deviation 7). All had an American Society
of Anesthesiologists score of 2 or more.Aims
Patients and Methods
To determine the normal values and usefulness of the C1/4 space
available for spinal cord (SAC) ratio and C1 inclination angle,
which are new radiological parameters for assessing atlantoaxial
instability in children with Down syndrome. We recruited 272 children with Down syndrome (including 14 who
underwent surgical treatment), and 141 children in the control group.
All were aged between two and 11 years. The C1/4 SAC ratio, C1 inclination
angle, atlas-dens interval (ADI), and SAC were measured in those
with Down syndrome, and the C1/4 SAC ratio and C1 inclination angle
were measured in the control group.Aims
Patients and Methods
The aim of this double-blind prospective randomised controlled
trial was to assess whether low intensity pulsed ultrasound (LIPUS)
accelerated or enhanced the rate of bone healing in adult patients
undergoing distraction osteogenesis. A total of 62 adult patients undergoing limb lengthening or bone
transport by distraction osteogenesis were randomised to treatment
with either an active (n = 32) or a placebo (n = 30) ultrasound
device. A standardised corticotomy was performed in the proximal
tibial metaphysis and a circular Ilizarov frame was used in all
patients. The rate of distraction was also standardised. The primary
outcome measure was the time to removal of the frame after adjusting
for the length of distraction in days/cm for both the per protocol
(PP) and the intention-to-treat (ITT) groups. The assessor was blinded
to the form of treatment. A secondary outcome was to identify covariates affecting
the time to removal of the frame.Aims
Patients and Methods
Loss or absence of proximal femoral bone in revision total hip
arthroplasty (THA) remains a significant challenge. While the main
indication for the use of proximal femoral replacements (PFRs) is
in the treatment of malignant disease, they have a valuable role
in revision THA for loosening, fracture and infection in patients
with bone loss. Our aim was to determine the clinical outcomes,
implant survivorship, and complications of PFRs used in revision
THA for indications other than malignancy. A retrospective review of 44 patients who underwent revision
THA using a PFR between 2000 and 2013 was undertaken. Their mean
age was 79 years (53 to 97); 31 (70%) were women. The bone loss
was classified as Paprosky IIIB or IV in all patients. The mean
follow-up was six years (2 to 12), at which time 22 patients had
died and five were lost to follow-up.Aims
Patients and Methods
Following the introduction of national standards in 2009, most
major paediatric trauma is now triaged to specialist units offering
combined orthopaedic and plastic surgical expertise. We investigated
the management of open tibia fractures at a paediatric trauma centre,
primarily reporting the risk of infection and rate of union. A retrospective review was performed on 61 children who between
2007 and 2015 presented with an open tibia fracture. Their mean
age was nine years (2 to 16) and the median follow-up was ten months
(interquartile range 5 to 18). Management involved IV antibiotics,
early debridement and combined treatment of the skeletal and soft-tissue injuries
in line with standards proposed by the British Orthopaedic Association.Aims
Patients and Methods
Patients with an acute Achilles tendon rupture (ATR) take a long
time to heal, have a high incidence of deep vein thrombosis (DVT)
and widely variable functional outcomes. This variation in outcome
may be explained by a lack of knowledge of adverse factors, and
a subsequent shortage of appropriate interventions. A total of 111 patients (95 men, 16 women; mean age 40.3, standard
deviation 8.4) with an acute total ATR were prospectively assessed.
At one year post-operatively a uniform outcome score, Achilles Combined
Outcome Score (ACOS), was obtained by combining three validated,
independent, outcome measures: Achilles tendon Total Rupture Score,
heel-rise height test, and limb symmetry heel-rise height. Predictors
of ACOS included treatment; gender; age; smoking; body mass index;
time to surgery; physical activity level pre- and post-injury; symptoms; quality
of life and incidence of DVT. Aims
Patients and Methods
It is widely held that most Baker’s cysts resolve after treatment
of the intra-articular knee pathology. The present study aimed to
evaluate the fate of Baker’s cysts and their associated symptoms
after total knee arthroplasty (TKA). In this prospective cohort study, 102 patients with (105 were
included, however three were lost to follow-up) an MRI-verified
Baker’s cyst, primary osteoarthritis and scheduled for TKA were
included. Ultrasound was performed to evaluate the existence and
the gross size of the cyst before and at one year after TKA. Additionally,
associated symptoms of Baker's cyst were recorded pre- and post-operatively.Aims
Patients and Methods