Abnormal femoral torsion (FT) is increasingly recognized as an additional cause for femoroacetabular impingement (FAI). It is unknown if in-toeing of the foot is a specific diagnostic sign for increased FT in patients with symptomatic FAI. The aims of this study were to determine: 1) the prevalence and diagnostic accuracy of in-toeing to detect increased FT; 2) if foot progression angle (FPA) and tibial torsion (TT) are different among patients with abnormal FT; and 3) if FPA correlates with FT. A retrospective, institutional review board (IRB)-approved, controlled study of 85 symptomatic patients (148 hips) with FAI or hip dysplasia was performed in the gait laboratory. All patients had a measurement of FT (pelvic CT scan), TT (CT scan), and FPA (optical motion capture system). We allocated all patients to three groups with decreased FT (< 10°, 37 hips), increased FT (> 25°, 61 hips), and normal FT (10° to 25°, 50 hips). Cluster analysis was performed.Aims
Patients and Methods
We investigated the long-term performance of the Tripolar Trident acetabular component used for recurrent dislocation in revision total hip arthroplasty. We assessed: 1) rate of re-dislocation; 2) incidence of complications requiring re-operation; and 3) Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain and functional scores. We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1994 and 2008. All patients had undergone revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 after more than three revisions. A total of 75 hips (73 patients) were treated with Tripolar liners due to recurrent instability with abductor deficiency, In addition, six patients had associated cerebral palsy, four had poliomyelitis, two had multiple sclerosis, two had spina bifida, two had spondyloepiphyseal dysplasia, one had previous reversal of an arthrodesis, and 21 had proximal femoral replacements. The mean age of patients at time of Tripolar insertions was 72 years (53 to 89); there were 69 female patients (two bilateral) and 42 male patients. All patients were followed up for a mean of 15 years (10 to 24). Overall, 55 patients (57 hips) died between April 2011 and February 2018, at a mean of 167 months (122 to 217) following their tripolar liner implantation. We extracted demographics, implant data, rate of dislocations, and incidence of other complications.Aims
Patients and Methods
Guided growth using eight-plates is commonly used for correction
of angular limb deformities in growing children. The principle is
of tethering at the physeal periphery while enabling growth in the
rest of the physis. The method is also applied for epiphysiodesis
to correct limb-length discrepancy (LLD). Concerns have been raised
regarding the potential of this method to create an epiphyseal deformity.
However, this has not been investigated. The purpose of this study
was to detect and quantify the occurrence of deformities in the
proximal tibial epiphysis following treatment with eight-plates. A retrospective study was performed including 42 children at
a mean age of 10.8 years (3.7 to 15.7) undergoing eight-plate insertion
in the proximal tibia for correction of coronal plane deformities
or LLD between 2007 and 2015. A total of 64 plates were inserted;
48 plates (34 patients) were inserted to correct angular deformities
and 16 plates (8 patients) for LLD. Medical records, Picture Archive
and Communication System images, and conventional radiographs were
reviewed. Measurements included interscrew angle, lateral and medial
plateau slope angles measured between the plateau surface and the
line between the ends of the physis, and tibial plateau roof angle defined
as 180° minus the sum of both plateau angles. Measurements were
compared between radiographs performed adjacent to surgery and those
at latest follow-up, and between operated and non-operated plateaus. Statistical
analysis was performed using BMDP Statistical Software.Aims
Patients and Methods
Unicompartmental knee arthroplasty (UKA) is one surgical option for treating symptomatic medial osteoarthritis. Clinical studies have shown the functional benefits of UKA; however, the optimal alignment of the tibial component is still debated. The purpose of this study was to evaluate the effects of tibial coronal and sagittal plane alignment in UKA on knee kinematics and cruciate ligament tension, using a musculoskeletal computer simulation. The tibial component was first aligned perpendicular to the mechanical axis of the tibia, with a 7° posterior slope (basic model). Subsequently, coronal and sagittal plane alignments were changed in a simulation programme. Kinematics and cruciate ligament tensions were simulated during weight-bearing deep knee bend and gait motions. Translation was defined as the distance between the most medial and the most lateral femoral positions throughout the cycle.Objectives
Methods
The role of high tibial osteotomy (HTO) is being questioned by
the use of unicompartmental knee arthroplasty (UKA) in the treatment
of medial compartment femorotibial osteoarthritis. Our aim was to
compare the outcomes of revision HTO or UKA to a total knee arthroplasty
(TKA) using computer-assisted surgery in matched groups of patients. We conducted a retrospective study to compare the clinical and
radiological outcome of patients who underwent revision of a HTO
to a TKA (group 1) with those who underwent revision of a medial
UKA to a TKA (group 2). All revision procedures were performed using
computer-assisted surgery. We extracted these groups of patients
from our database. They were matched by age, gender, body mass index,
follow-up and pre-operative functional score. The outcomes included
the Knee Society Scores (KSS), radiological outcomes and the rate
of further revision.Aims
Patients and Methods
The objectives of this study were to compare postoperative pain, analgesia requirements, inpatient functional rehabilitation, time to hospital discharge, and complications in patients undergoing conventional jig-based unicompartmental knee arthroplasty (UKA) This prospective cohort study included 146 patients with symptomatic medial compartment knee osteoarthritis undergoing primary UKA performed by a single surgeon. This included 73 consecutive patients undergoing conventional jig-based mobile bearing UKA, followed by 73 consecutive patients receiving robotic-arm assisted fixed bearing UKA. All surgical procedures were performed using the standard medial parapatellar approach for UKA, and all patients underwent the same postoperative rehabilitation programme. Postoperative pain scores on the numerical rating scale and opiate analgesia consumption were recorded until discharge. Time to attainment of predefined functional rehabilitation outcomes, hospital discharge, and postoperative complications were recorded by independent observers.Aims
Patients and Methods
The factors that predispose to recurrent instability and revision
stabilization procedures after arthroscopic Bankart repair for anterior
glenohumeral instability remain unclear. We sought to determine
the rate and risk factors associated with ongoing instability in
patients undergoing arthroscopic Bankart repair for instability
of the shoulder. We used the Statewide Planning and Research Cooperative System
(SPARCS) database to identify patients with a diagnosis of anterior
instability of the shoulder undergoing arthroscopic Bankart repair
between 2003 and 2011. Patients were followed for a minimum of three
years. Baseline demographics and subsequent further surgery to the ipsilateral
shoulder were analyzed. Multivariate analysis was used to identify
independent risk factors for recurrent instability.Aims
Materials and Methods
The aims of this study were to determine the proportion of patients
with outlier varus or valgus alignment in kinematically aligned
total knee arthroplasty (TKA), whether those with outlier varus
or valgus alignment have higher forces in the medial or lateral
compartments of the knee than those with in-range alignment and
whether measurements of the alignment of the limb, knee and components
predict compartment forces. The intra-operative forces in the medial and lateral compartments
were measured with an instrumented tibial insert in 67 patients
who underwent a kinematically aligned TKA during passive movement.
The mean of the forces at full extension, 45° and 90° of flexion
determined the force in the medial and lateral compartments. Measurements
of the alignment of the limb and the components included the hip-knee-ankle
(HKA) angle, proximal medial tibial angle (PMTA), and distal lateral
femoral angle (DLFA). Measurements of the alignment of the knee
and the components included the tibiofemoral angle (TFA), tibial
component angle (TCA) and femoral component angle (FCA). Alignment was
measured on post-operative, non-weight-bearing anteroposterior (AP)
scanograms and categorised as varus or valgus outlier or in-range
in relation to mechanically aligned criteria.Aims
Patients and Methods
The aim of this study was to investigate the long-term clinical
and radiological outcome of patients who suffer recurrent injuries
to the anterior cruciate ligament (ACL) after reconstruction and
require revision surgery. From a consecutive series of 200 patients who underwent primary
reconstruction following rupture of the ACL, we identified 36 who
sustained a further rupture, 29 of whom underwent revision surgery.
Patients were reviewed prospectively at one, two, seven, 15 and
about 20 years after their original surgery. Primary outcome measures
were the number of further ruptures, the posterior tibial slope
(PTS), and functional and radiological outcomes. These were compared
with a gender and age matched cohort of patients who underwent primary
ACL reconstruction only.Aims
Patients and Methods
The aim of this study was to report the outcome of the non-operative
treatment of high-grade posterior cruciate ligament (PCL) injuries,
particularly Hughston grade III injuries, which have not previously
been described. This was a prospective study involving 46 consecutive patients
who were athletes with MRI-confirmed isolated PCL injuries presenting
within four weeks of injury. All had Hughston grade II (25 athletes)
or III (21 athletes) injuries. Our non-operative treatment regimen
involved initial bracing, followed by an individualised rehabilitation
programme determined by the symptoms and physical signs. The patients
were reviewed until they had returned to sports-specific training,
and were reviewed again at a mean of 5.2 years (3 to 9).Aims
Patients and Methods
It has been hypothesized that patellofemoral pain, a common knee condition in adolescents and young adults, may be a precursor of degenerative joint changes and may ultimately lead to patellofemoral osteoarthritis. Since both conditions share several mechanical disease characteristics, such as altered contact area between the femur and patella and increased joint stress, we investigated whether these conditions share similar and different shape characteristics of the patella compared with normal controls. This cross-sectional study compared three different study populations: 32 patellofemoral pain subjects (mean age, 32 years (22 to 45); 72% female); 56 isolated radiological patellofemoral osteoarthritis subjects (mean age, 54 years (44 to 58); 89% female); and 80 healthy control subjects (mean age, 52 years (44 to 58); 74% female). Measurements included questionnaires, and lateral and skyline radiographs of the knee. Two separate 30-point 2D statistical shape models of the patella were created from the lateral and skyline radiographs. A general linear model was used to test for differences in standardized shape modes (a specific shape variant of the patella) between patellofemoral osteoarthritis, patellofemoral pain, and controls, using Bonferroni correction and adjustment for body mass index and gender.Objectives
Methods
It is important to consider sagittal pelvic rotation when introducing
the acetabular component at total hip arthroplasty (THA). The purpose
of this study was to identify patients who are at risk of unfavourable
pelvic mobility, which could result in poor outcomes after THA. A consecutive series of 4042 patients undergoing THA had lateral
functional radiographs and a low-dose CT scan to measure supine
pelvic tilt, pelvic incidence, standing pelvic tilt, flexed-seated
pelvic tilt, standing lumbar lordotic angle, flexed-seated lumbar
lordotic angle, and lumbar flexion. Changes in pelvic tilt from
supine-to-standing positions and supine-to-flexed-seated positions
were determined. A change in pelvic tilt of 13° between positions was
deemed unfavourable as it alters functional anteversion by 10° and
effectively places the acetabular component outside the safe zone
of orientation.Aims
Patients and Methods
In patients undergoing medial opening wedge high tibial osteotomy
(MOWHTO), soft tissue opening on the medial side of the knee is
difficult to predict. When the load bearing axis is corrected beyond
a certain point, the knee joint tilts open on the medial side. We
therefore hypothesised that there is a tipping point and defined
this as the coronal hypomochlion. In this prospective study of 150 navigated MOWHTOs (144 consecutive
patients), data were collected before surgery and at three months
post-operatively. In order to calculate the hypomochlion, we compared
the respective changes to the joint line convergence angle (JLCA)
with the post-operative axis of the leg. The change to the medial proximal
tibial angle accounts for only about 80% of the change to the femorotibial
angle; 20% of the correction can therefore be attributed to non-osseous,
soft-tissue changes.Aims
Patients and Methods
The aim of this study was to report the mid-term clinical outcome
of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties
when used in patients with rheumatoid arthritis (RA). We retrospectively reviewed 87 elbows, in 75 patients with RA,
which was replaced using a cemented JACE total elbow arthroplasty
(TEA) between August 2003 and December 2012, with a follow-up of
96%. There were 72 women and three men, with a mean age of 62 years
(35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition
of each elbow before and after surgery was assessed using the Mayo
Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening
was defined as a progressive radiolucent line of >1 mm that was
completely circumferential around the prosthesis.Aims
Patients and Methods
The aim of this study was to investigate the structural integrity of torn and non-torn human acetabular labral tissue. A total of 47 human labral specimens were obtained from a biobank. These included 22 torn specimens and 25 control specimens from patients undergoing total hip arthroplasty with macroscopically normal labra. The specimens underwent dynamic shear analysis using a rheometer to measure storage modulus, as an indicator of structural integrity.Objectives
Methods
The primary aim of this study was to determine the surgical team’s
learning curve for introducing robotic-arm assisted unicompartmental
knee arthroplasty (UKA) into routine surgical practice. The secondary
objective was to compare accuracy of implant positioning in conventional
jig-based UKA versus robotic-arm assisted UKA. This prospective single-surgeon cohort study included 60 consecutive
conventional jig-based UKAs compared with 60 consecutive robotic-arm
assisted UKAs for medial compartment knee osteoarthritis. Patients
undergoing conventional UKA and robotic-arm assisted UKA were well-matched
for baseline characteristics including a mean age of 65.5 years
(Aims
Patients and Methods