We describe a method of internal fixation for femoral neck fractures which has been newly developed to reduce the frequency of early complications. Two cannulated screws are inserted in the axis of the femoral neck to reach into the subchondral bone of the femoral head. The screws are inserted over guide pins and the tip of the screw is self-tapping and designed to provide good anchorage in the femoral head. We used this method in 44 consecutive patients in a prospective study with no exclusions, followed for a minimum of 24 months. All
Ten patients with humeral shaft fractures and no clinical or radiographic signs of healing after at least six weeks' immobilisation were treated by flexible intramedullary nailing using a closed retrograde technique. Bone grafting was not performed, and active movement was encouraged after operation. Nine
A review of 61 patients with dislocation of the lunate (some with and some without fracture of the scaphoid) showed that the majority had satisfactory results at an average follow-up of three and a half years. Most patients with a simple dislocation had a good or satisfactory result; radiological instability was noted in a quarter of the wrists but was not often associated with symptoms. Two-thirds of the patients with an associated fracture of the scaphoid had a good or satisfactory result. Immediate percutaneous wire fixation of the reduced scaphoid, whether it is fractured or not, is the best way of maintaining normal anatomical relationship while the ligaments and
Diaphyseal fractures of the tibia in 80 patients were treated by external skeletal fixation using a unilateral frame, either in a fixed mode or in a mode which allowed the application of a small amount of predominantly axial micromovement. Patients were allocated to each regime by random selection.
We present a prospective study of the treatment of 32 unstable Colles’ fractures by external fixation and cancellous grafting with minimal exposure. We inserted an external fixator between the radius and the second metacarpal, and maintained ligamentotaxis for five weeks. In 27 patients the result was good or excellent, but five
There is evidence that
From 1987 to 1993 we treated 33 patients with 29 phalangeal and seven metacarpal fractures by external fixation using a mini-Hoffmann device. There were 27 open and 25 comminuted fractures. In 12 patients one or more tendons was involved. The mean follow-up was 4.4 years. Complications occurred in ten fractures; two required repositioning of the fixator. All the
There is evidence to suggest that
It is increasingly appreciated that coordinated regulation of angiogenesis and osteogenesis is needed for bone formation. How this regulation is achieved during peri-implant bone healing, such as osseointegration, is largely unclear. This study examined the relationship between angiogenesis and osteogenesis in a unique model of osseointegration of a mouse tibial implant by pharmacologically blocking the vascular endothelial growth factor (VEGF) pathway. An implant was inserted into the right tibia of 16-week-old female C57BL/6 mice (n = 38). Mice received anti-VEGF receptor-1 (VEGFR-1) antibody (25 mg/kg) and VEGF receptor-2 (VEGFR-2) antibody (25 mg/kg; n = 19) or an isotype control antibody (n = 19). Flow cytometric (n = 4/group) and immunofluorescent (n = 3/group) analyses were performed at two weeks post-implantation to detect the distribution and density of CD31hiEMCNhi endothelium. RNA sequencing analysis was performed using sorted CD31hiEMCNhi endothelial cells (n = 2/group). Osteoblast lineage cells expressing osterix (OSX) and osteopontin (OPN) were also detected with immunofluorescence. Mechanical pull-out testing (n = 12/group) was used at four weeks post-implantation to determine the strength of the bone-implant interface. After pull-out testing, the tissue attached to the implant surface was harvested. Whole mount immunofluorescent staining of OSX and OPN was performed to determine the amount of osteoblast lineage cells.Aims
Materials and Methods
We report 60 benign bone tumours treated by resection and curettage followed by the implantation of calcium hydroxyapatite ceramic (CHA). After follow-up of six to 60 months (average 36), no patient had local recurrence of the tumour or any adverse effects from the implants. In almost all cases radiography showed that the CHA was well-incorporated into the host bone, with new bone formation in and around the CHA. Corrective remodelling of deformed bone and normal
The Medoff sliding plate (MSP) is a new device used to treat intertrochanteric and subtrochanteric fractures. There are three options for sliding; either along the shaft or the neck of the femur, or a combination of both. In a prospective series of 108 consecutive displaced intertrochanteric fractures we used combined dynamic compression. The patients were followed clinically and radiologically for one year. All
In a prospective study, 170 impacted femoral neck fractures were treated by early mobilisation and weight-bearing. The overall mortality at one year was 16%. In the 167 patients who were followed up until
The levels of the active metabolites of vitamin D were measured in the callus and in the epiphyseal growth plate of chicks given radioactive cholecalciferol during
Experimentally produced fractures in long bones studied by light and electron microscopic histochemistry were found to heal by a process of enchondral calcification. There was intense proliferation in the cells of the cambium layer of the periosteum, with differentiation to chondroblasts and osteoblasts, suggesting that this layer was the primary tissue responsible for development of the callus. Cytoplasmic processes of the hypertrophic chondrocytes appeared to bud and produce matrix vesicles. Alkaline phosphatase activity was detected along the plasma membrane of the hypertrophic chondrocytes and around the matrix vesicles, before any signs of mineral deposition. Calcification took place by deposition of hydroxyapatite crystals in and around these matrix vesicles which frequently showed alkaline phosphatase activity. It is suggested that there is a close functional association between alkaline phosphatase activity and calcification in the process of
Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.Aims
Methods
Of 290 Ugandan children and adolescents with proven Burkitt's lymphoma 11 had lesions in the long bones or the pelvis. These started in the medulla as small osteolytic foci which coalesced and penetrated the cortex causing subperiosteal new bone formation in layers or spicules, and giving rise to large soft-tissue masses. Common sites were the femoral and tibial diaphyses and the metaphyses around the knee. Five were in the epiphyses. Other sites were the pelvis, humerus and ulna. One patient had a lymphomatous synovial effusion of the knee. In the lower limbs the lesions were often bilateral and symmetrical. Five patients had pathological fractures. Radiologically the lesions mimicked Ewing's sarcoma, osteosarcoma, osteomyelitis, acute leukaemia, syphilis and yaws, but clinically they were relatively painless, an important differential diagnostic feature. In the five patients with sustained remissions after chemotherapy the lesions and
In the assessment of
A lack of supporting clinical studies have been published to determine the ideal length of intramedullary nail in fixation of trochanteric fractures of the hip. Nevertheless, there has been a trend to use shorter intramedullary nails for the internal fixation of trochanteric hip fractures. Our aim was to determine if the length of nail affected the outcome. We randomized 229 patients with a trochanteric hip fracture between two implants: a ‘standard’ nail of 220 mm and a shorter nail of 175 mm, which had decreased proximal angulation (4° vs 7°) and a reduced diameter at the level of the lesser trochanter. Patients were followed up for one year by a nurse blinded to the type of implant used to determine if there were differences in mobility and pain with two nail designs. Pain was assessed on a scale of 1 (none) to 8 (severe and constant) and mobility on a scale of 1 (full mobility) to 9 (immobile).Aims
Methods