Advertisement for orthosearch.org.uk
Results 201 - 220 of 1995
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1281 - 1286
1 Oct 2009
Olsen M Davis ET Chiu M Gamble P Tumia N Boyle RA Schemitsch EH

The computed neck-shaft angle and the size of the femoral component were recorded in 100 consecutive hip resurfacings using imageless computer-navigation and compared with the angle measured before operation and with actual component implanted. The reliability of the registration was further analysed using ten cadaver femora. The mean absolute difference between the measured and navigated neck-shaft angle was 16.3° (0° to 52°). Navigation underestimated the measured neck-shaft angle in 38 patients and the correct implant size in 11. Registration of the cadaver femora tended to overestimate the correct implant size and provided a low level of repeatability in computing the neck-shaft angle.

Prudent pre-operative planning is advisable for use in conjunction with imageless navigation since misleading information may be registered intraoperatively, which could lead to inappropriate sizing and positioning of the femoral component in hip resurfacing.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 150 - 151
1 Jan 2004
KIM HJ


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 371 - 375
1 Apr 2003
Reis ND Schwartz O Militianu D Ramon Y Levin D Norman D Melamed Y Shupak A Goldsher D Zinman C

A vascular necrosis (AVN) of the head of the femur is a potentially crippling disease which mainly affects young adults. Although treatment by exposure to hyperbaric oxygen (HBO) is reported as being beneficial, there has been no study of its use in treated compared with untreated patients. We selected 12 patients who suffered from Steinberg stage-I AVN of the head of the femur (four bilateral) whose lesions were 4 mm or more thick and/or 12.5 mm or more long on MRI. Daily HBO therapy was given for 100 days to each patient. All smaller stage-I lesions and more advanced stages of AVN were excluded. These size criteria were chosen in order to compare outcomes with an identical size of lesion in an untreated group described earlier. Overall, 81% of patients who received HBO therapy showed a return to normal on MRI as compared with 17% in the untreated group. We therefore conclude that hyperbaric oxygen is effective in the treatment of stage-I AVN of the head of the femur.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 681 - 682
1 Jul 1996
LAFFORGUE P CHAGNAUD C ACQUAVIVA PC ARGENSON JN AUBANIAC JM


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 365 - 367
1 May 1993
Fordyce M Solomon L

We used MRI to examine the hips of 32 asymptomatic patients at 9 to 21 months after renal transplantation covered by high-dose corticosteroids. Five hips in three patients showed changes which indicate avascular necrosis, although radiographs, CT scans and isotope scans were normal. These patients had repeat MRI scans after another two years and three years. One patient with bilateral MRI changes developed symptoms and abnormal radiographs and CT and isotope scans in one hip nine months after the abnormal MRI. Intraosseous pressure was found to be raised in both hips, and core biopsies revealed necrotic bone on both sides. The other three hips have remained asymptomatic with unchanged MRI appearances three years after the initial MRI. It seems that idiopathic avascular necrosis does not always progress to bone collapse in the medium term.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 866 - 866
1 Sep 1991
Mills C Hooper J


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 389 - 389
1 May 1972
Chalmers J


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 2 | Pages 354 - 355
1 May 1969
Stougêard J

Two cases of post-traumatic avascular necrosis of the head of the femur without evident dislocation of the head or fracture of the head or neck are recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 4 | Pages 854 - 857
1 Nov 1962
Price ER


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 1 | Pages 28 - 30
1 Feb 1960
Charnley J


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 2 | Pages 173 - 180
1 May 1952
Robert Judet J

At the end of this short study we have to sum up our views about the use of the acrylic prosthesis for arthroplasty of the hip. Some fatalities and a proportion of bad or poor results make this operation one to be undertaken only by surgeons well trained in the surgery of the hip and only on patients who really need it. However, the tolerance of the tissues to acrylic resin and the fixation of the stem in the neck of the femur promise to be lasting. We know that a much longer time is necessary to confirm these general statements, which proceed from an experience of only five years and the study of six hundred cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 1 | Pages 119 - 121
1 Feb 1951
Gibson A Williams TH


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 530 - 532
1 Nov 1983
Scales J


The Journal of Bone & Joint Surgery British Volume
Vol. 32-B, Issue 2 | Pages 166 - 173
1 May 1950
Judet J Judet R

We have endeavoured to make known the results of a simple type of arthroplasty of the hip which is well tolerated even by elderly patients. It has not been the purpose of this article to compare former operations with our own, a newcomer in the field of surgery of the hip. In particular we do not wish to compare our comparatively recent results with Smith-Petersen's well-established method of cup arthroplasty—a magnificent contribution to the surgery of the region. The results we have already obtained, however, appear sufficiently favourable to merit further study and development of the method. If the future confirms the value of our early results, we shall perhaps be able to suggest operation to patients who suffer more from loss of function than from pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 781 - 786
1 Jun 2010
Zhao G Yamamoto T Ikemura S Motomura G Mawatari T Nakashima Y Iwamoto Y

We investigated the factors related to the radiological outcome of a transtrochanteric curved varus osteotomy in patients with osteonecrosis of the hip. We reviewed 73 hips in 62 patients with a mean follow-up of 12.4 years (5 to 31.1). There were 28 men and 34 women, with a mean age of 33.3 years (15 to 68) at the time of surgery. The 73 hips were divided into two groups according to their radiological findings: group 1 showed progression of collapse and/or joint-space narrowing; group 2 had neither progressive collapse nor joint-space narrowing. Both of these factors and the radiological outcomes were analysed by a stepwise discriminant analysis. A total of 12 hips were categorised as group 1 and 61 as group 2. Both the post-operative intact ratio and the localisation of the necrotic lesion correlated with the radiological outcome. The cut-off point of the postoperative intact ratio to prevent the progression of collapse was 33.6%, and the cut-off point to prevent both the progression of collapse and joint-space narrowing was 41.9%.

The results of this study indicate that a post-operative intact ratio of 33.0% is necessary if a satisfactory outcome is to be achieved after this varus osteotomy.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 462 - 462
1 Apr 2003
BEAULÉ PE


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 3 - 9
1 Jan 1985
Ficat R


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1610 - 1617
1 Dec 2014
Lainiala O Eskelinen A Elo P Puolakka T Korhonen J Moilanen T

We conducted a retrospective study to assess the prevalence of adverse reactions to metal debris (ARMD) in patients operated on at our institution with metal-on-metal (MoM) total hip replacements with 36 mm heads using a Pinnacle acetabular shell. A total of 326 patients (150 males, 175 hips; 176 females, 203 hips) with a mean age of 62.7 years (28 to 85) and mean follow-up of 7.5 years (0.1 to 10.8) participating in our in-depth modern MoM follow-up programme were included in the study, which involved recording whole blood cobalt and chromium ion measurements, Oxford hip scores (OHS) and plain radiographs of the hip and targeted cross-sectional imaging. Elevated blood metal ion levels (> 5 parts per billion) were seen in 32 (16.1%) of the 199 patients who underwent unilateral replacement. At 23 months after the start of our modern MoM follow-up programme, 29 new cases of ARMD had been revealed. Hence, the nine-year survival of this cohort declined from 96% (95% CI 95 to 98) with the old surveillance routine to 86% (95% CI 82 to 90) following the new protocol. Although ARMD may not be as common in 36 mm MoM THRs as in those with larger heads, these results support the Medicines and Healthcare Products Regulatory Agency guidelines on regular reviews and further investigations, and emphasise the need for specific a follow-up programme for patients with MoM THRs.

Cite this article: Bone Joint J 2014; 96-B:1610–17.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 447 - 451
1 Apr 2002
Eggli S z’Brun S Gerber C Ganz R

In this prospective, randomised study, we have compared the wear rate of cemented, acetabular polyethylene cups articulating with either a 22 mm or a 32 mm cobalt-chromium head. We evaluated 89 patients who had a total of 484 radiographs. The mean follow-up period was 71.4 months (SD 29.1). All the radiographs were digitised and electronically measured.

The linear wear rate was significantly higher during the first two years and decreased after this period to a constant value. We suggest that this is partly due to a ‘run-in’ process caused by irregularities between surfaces of the cup and head and an initial plastic deformation of the polyethylene. The mean volumetric wear was 120.3 mm3/year for the 32 mm head, which was significantly higher than the 41.5 mm3/year for the 22 mm heads. The mean linear wear rate was not significantly different. We were, however, unable to find radiological signs of osteolysis in the patients who had higher wear rates.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 794 - 796
1 Sep 1990
Richards R Evans G Egan J Shearer

We compared, under laboratory conditions, the resistance to cutting out of the AO dynamic hip screw and the Pugh sliding nail. The mean load at cut out, adjusted for bone strength, was 70% greater for the Pugh sliding nail. The reasons for this difference are discussed.