Advertisement for orthosearch.org.uk
Results 201 - 220 of 754
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1118 - 1123
1 Nov 2004
Singh S Trikha SP Edge AJ

We describe the clinical and radiological results of 38 total hip replacements (THR) using the JRI Furlong hydroxyapatite-ceramic (HAC)-coated femoral component in patients younger than 50 years. The mean age at the time of operation was 42 years (22 to 49) and the mean length of follow-up was ten years (63 to 170 months). All patients receiving a Furlong HAC THR were entered into the study regardless of the primary pathology including patients who had undergone previous hip surgery. The mean Harris hip score improved from 44 before operation to 92 at the last postoperative review. After 12 years the cumulative surivival for the stem was 100% (95% confidence interval 89 to 100). No femoral component was revised. Our results show that the Furlong HAC implant gives excellent long-term results in young patients with high demands


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 614 - 618
1 May 2000
Fujita H Iida H Ido K Matsuda Y Oka M Nakamura T

We evaluated the efficacy and biocompatibility of porous apatite-wollastonite glass ceramic (AW-GC) as an intramedullary plug in total hip replacement (THR) for up to two years in 22 adult beagle dogs. Cylindrical porous AW-GC rods (70% porosity, mean pore size 200 3m) were prepared. Four dogs were killed at 1, 3, 6 and 12 months each and six at 24 months after implantation. Radiological evaluation confirmed the efficacy of porous AW-CG as an intramedullary plug. Histological evaluation showed osteoconduction at one month and resorption of the porous AW-GC, which was replaced by newly-formed bone, at 24 months. Our findings indicate that porous AW-GC can be used clinically as an intramedullary plug in THR


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 725 - 727
1 Sep 1994
James P Butcher I Gardner E Hamblen D

We investigated the incidence of cephalosporin-resistant bacteria in infected hip arthroplasties. Of 740 patients having hip replacement or related procedures performed over three years, 30 had positive bacteriological cultures from tissue removed at the time of surgery. In 18 of the 30 cultures Staphylococcus epidermidis was grown and 12 of these were methicillin-resistant. A prospective study of skin swabs taken from 100 consecutive patients at the time of admission for THR showed methicillin-resistant Staphylococcus epidermidis in 25. This cephalosporin-resistant organism was shown to be the commonest proven cause of infection, and its presence as a skin commensal raises important questions about current antibiotic prophylaxis for joint replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 884 - 891
1 Nov 1996
Malchau H Herberts P Wang YX Kärrholm J Romanus B

We enrolled 98 patients (107 hips) with a mean age of 47 years (SD 8.6) into a prospective study of the Madreporic Lord THR; 34 hips had primary and 73 secondary osteoarthritis. After ten years, the survival rate using revision as the endpoint for failure was 70% (±9) for the cup and 98% (±0.3) for the stem. The combined clinical and radiological survival rates were 46% (±11) and 81% (±10), respectively. Osteoporosis due to stress-shielding was observed in the proximal femur. Hips with radiologically dense bone postoperatively showed the most pronounced bone loss. We recommend continued radiological follow-up of patients with this type of implant to allow revision to be performed before there is severe bony destruction of the pelvis


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 520 - 527
1 Jul 1995
Murray D Carr A Bulstrode C

To assist surgeons to select a total hip replacement (THR) we present comparative information on all such implants on the market in the UK. We identified 62 different primary THRs, manufactured by 19 companies; half had been introduced in the last five years, and only 30% have any results published in peer-reviewed journals. The prices range from 250 pounds to 2000 pounds, and the two cheapest implants have the longest reported follow-up. The number of THR implants available in the UK, and presumably the rest of the world, is rapidly increasing, but there is little or no scientific evidence that the newer, more expensive, implants are better than established designs. Some will undoubtedly be worse. We believe that this situation is unsatisfactory and make recommendations for improvement, in particular that preference be given to implants with good results in published peer-reviewed long-term clinical trials


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 960 - 962
1 Sep 2003
Mehta JS Nicolaou N Kiryluk S Fordyce MJF

Venous ulceration is a chronic disabling complication of deep-vein thrombosis. The aim of this study was to estimate the incidence of venous leg ulcers five years or more after total hip replacement (THR) and to investigate some of the clinical features associated with their development. We carried out a postal survey of all patients who had undergone a THR 5 to 12 years previously. Replies from 816 patients showed that 66 (8.1%) had a history of leg ulcers. The prevalence of active ulceration was 2.6% and 43 patients (5.3%) reported developing ulceration since their hip replacement. A clinical review determined that 31 (3.8%) of these were true venous ulcers. The ulcers occurred more commonly on the operated side and developed at a mean of 5.8 years (18 months to 12 years) after the first arthroplasty. A mean of 1.9 arthroplasties (1 to 5) (primary and revision) were carried out before the ulcers appeared. The overall incidence of ulcers was similar to that in the general population


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 93 - 98
1 Jan 1997
Britton AR Murray DW Bulstrode CJ McPherson K Denham RA

We have assessed the relative value of various outcome measures after THR, by the analysis of follow-up data from over 2000 patients. They had been reviewed clinically and radiologically six months after operation, at one year, and then every two years, some for 16 years. At each review their pain level, stiffness and opinion of progress were scored and a radiograph taken. We found that pain level was the most informative outcome as a predictor of revision and correlated well with the patients’ opinions. We made a comparison between the six types of implant in the series, using survival analysis and log-rank testing with different pain levels as endpoints. This analysis revealed differences which were not detected by survival analysis using the traditional endpoint of revision. We therefore recommend the use of different levels of pain as the main outcome measures after total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 185 - 190
1 Mar 1996
Dawson J Fitzpatrick R Carr A Murray D

We developed a 12-item questionnaire for completion by patients having total hip replacement (THR). A prospective study of 220 patients was undertaken before operation and at follow-up six months later. Each completed the new questionnaire as well as the SF36, and some the Arthritis Impact Measurement Scales (AIMS). An orthopaedic surgeon assessed the Charnley hip score. The single score derived from the questionnaire had a high internal consistency. Reproducibility was examined by test-retest reliability and was found to be satisfactory. The validity of the questionnaire was established by obtaining significant correlation in the expected direction with the Charnley scores and relevant scales of the SF36 and the AIMS. Sensitivity to change was assessed by analysing the differences between the preoperative scores and those at the follow-up. The standardised effect size for the new questionnaire compared favourably with that for the SF36 and the AIMS. The new questionnaire provides a measure of outcome for THR which is short, practical, reliable, valid and sensitive to clinically important changes


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 715 - 719
1 Sep 1995
Warwick D Bannister G Glew D Mitchelmore A Thornton M Peters T Brookes S

In previous randomised clinical trials of thromboprophylaxis after total hip replacement, low-molecular-weight heparin has been given for an arbitrary 7 to 14 days. The risk factors are mainly perioperative and it is possible that a shorter course may be adequate. We assessed the safety and effectiveness of a three-day course. We assessed 156 primary THR patients after randomisation to either a control group or to receive enoxaparin at 12 hours preoperatively and 12 and 36 hours postoperatively. Thrombosis was diagnosed by routine venography. Haemorrhagic side-effects were assessed by measurement of blood loss, and soft-tissue side-effects by descriptive scores for wound discharge and bruising of the leg. The prevalence of calf thrombosis was 15.4% in the enoxaparin group and 32.1% in the control group (p = 0.01); the prevalence of proximal thrombosis was 15.4% and 17.9% respectively (not significant). There was no difference in haemorrhagic side-effects or wound discharge, but there was more bruising in the enoxaparin group


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 646 - 649
1 Jul 2003
Sterling GJ Crawford S Potter JH Koerbin G Crawford R

We prospectively investigated a consecutive series of ten patients undergoing a cemented primary total hip replacement (THR) for osteoarthritis in order to establish the elution characteristics of Simplex-tobramycin bone cement (Howmedica, Limerick, Ireland). Specimens of blood, urine and drainage fluid were collected for 72 hours postoperatively. Very high concentrations of tobramycin were found in the drainage fluid, with mean levels at one hour of 103 mg/l, which steadily declined to 15.1 mg/l after 48 hours. The mean serum tobramycin levels reached a peak of 0.94 mg/l at three hours and declined rapidly to 0.2 mg/l by 48 hours. The mean urinary tobramycin levels peaked at 57.8 mg/l at 12 hours with a rapid decline to 12.6 mg/l by 24 hours. There was a direct correlation between the amount of tobramycin bone cement which was implanted and the amount of tobramycin systemically absorbed. Excellent local delivery was achieved with minimal systemic concentrations. Simplex-tobramycin bone cement is an efficient and safe method for the delivery of antibiotics after THR


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 838 - 842
1 Aug 2001
Chambers IR Fender D McCaskie AW Reeves BC Gregg PJ

The radiological features of the cement mantle around total hip replacements (THRs) have been used to assess aseptic loosening. In this case-control study we investigated the risk of failure of THR as predictable by a range of such features using data from patients recruited to the Trent Regional Arthroplasty Study (TRAS). An independent radiological assessment was undertaken on Charnley THRs with aseptic loosening within five years of surgery and on a control group from the TRAS database. Chi-squared tests were used to test the probability of obtaining the observed data by chance, and odds ratios were calculated to estimate the strength of association for different features. Several features were associated with a clinically important increase (> twofold) in the risk of loosening, which was statistically significant for four features (p < 0.01). Inadequate cementation (Barrack C and D grades) was the most significant feature, with an estimated odds ratio of 9.5 (95% confidence interval 3.2 to 28.4, p < 0.0001) for failure


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 382 - 390
1 May 1998
Eggli S Pisan M Müller ME

To analyse the value and accuracy of preoperative planning for total hip replacement (THR) we digitised electronically and compared the hand-sketched preoperative plans with the pre- and postoperative radiographs of 100 consecutive primary THRs. The correct type of prosthesis was planned in 98%; the agreement between planned and actually used components was 92% on the femoral side and 90% on the acetabular side. The mean (± SD) absolute difference between the planned and actual position of the centre of rotation of the hip was 2.5 ± 1.1 mm vertically and 4.4 ± 2.1 mm horizontally. On average, the inclination of the acetabular component differed by 7 ± 2° and anteversion by 9 ± 3° from the preoperative plans. The mean postoperative leg-length difference was 0.3 ± 0.1 cm clinically and 0.2 ± 0.1 cm radiologically. More than 80% of intraoperative difficulties were anticipated. Preoperative planning is of significant value for the successful performance of THR


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 229 - 234
1 Mar 1994
Wright J Rudicel S Feinstein A

We aimed to assess individual differences in complaints in patients just before total hip replacement (THR) and the importance attached to the relief of each of them. In a pilot study, using open-ended interviews, we identified 16 main complaints, four of which (night pain, unequal leg length and discomfort during sexual and recreational activities) were not included in any of the six hip-rating scales in general use. Each of the 16 complaints was then assessed in 72 patients and rated for severity and the relative importance of relief. From this we calculated a severity-importance rating for each complaint and a patient-specific score for all complaints. The 72 patients had a mean age of 64 years (17 to 92) and 51% were men. The most important reasons for wanting a THR were day pain and walking difficulty, but the complaints mentioned above and not included in standard hip scores were also important. Greater attention to the individual requirements of patients might improve evaluation of the outcome of orthopaedic treatments


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 611 - 613
1 Jul 1998
Clarke MT Green JS Harper WM Gregg PJ

A total of 110 total knee replacements (TKRs) was randomised to receive either a cemented or an uncemented prosthesis. Postoperative venography at five to seven days was used to compare the prevalence, site and size of deep-vein thrombosis (DVT). We also compared the findings with those of postoperative venography in a group of patients with cemented total hip replacements (THRs). The total prevalence of DVT was significantly greater after uncemented (81%) than after cemented TKR (55%). Both knee groups had a significantly higher prevalence of DVT than in cemented hip replacements (32%). We found no difference in the proportion with proximal DVT in the three groups (14%, 15% and 16%). The median length of the thrombi was significantly greater after cemented (26.5 cm) than after uncemented TKR (11 cm) or after cemented THR (7 cm). This difference was mainly due to greater lengths of distal rather than proximal thrombi. We conclude that the use of cement may affect the formation of DVT after joint replacement, but does not appear to lead to an increased incidence


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 439 - 443
1 May 1994
Johnsson R Franzen H Nilsson L

From 1970 to 1980 cemented metal-on-plastic total hip replacement was performed on 799 hips with primary osteoarthritis using one surgical technique. At the 10- to 20-year follow-up there had been 97 revisions for mechanical loosening. Univariate survivorship analysis showed that an increased risk of revision was associated with male gender, young age at primary THR, the Brunswik and Lubinus snap-fit prostheses with large femoral heads (as compared with the Charnley prosthesis), and varying experience of the surgeon. Multivariate statistical analysis showed a three-fold increased risk of revision for men (p < 0.0001), an increase in relative risk of 1.8 per 10 years younger at surgery (p < 0.0001), a fivefold increase in risk for the Brunswik prosthesis (p < 0.0001) and a twofold increase for the Lubinus prosthesis (p = 0.0067). Inexperience of the surgeon, however, was not validated as a risk factor. The study shows that the true risk factors for revision can be identified accurately by combining univariate survivorship and multivariate statistical analyses


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 191 - 194
1 Mar 1996
McCaskie AW Brown AR Thompson JR Gregg PJ

Three radiological methods are commonly used to assess the outcome of total hip replacement (THR). They aim to record the appearance of lucent areas and migration of the prosthesis in a reproducible manner. Two of them were designed to monitor the implant through time and one to grade the quality of cementing. We have measured the level of inter- and intraobserver agreement in all three systems. We randomised 30 patients to receive either finger packing or retrograde gun cementing during Charnley hip replacements. The postoperative departmental radiographs were evaluated in a blinded study by two orthopaedic trainees, two consultants and two experts in THR. The trainees and consultants repeated the exercise at least two weeks later. We used the unweighted kappa statistic to establish the levels of agreement. In general, intraobserver agreement was moderate but interobserver agreement was poor, with levels similar to or less than those expected by chance. Our results indicate that such systems cannot provide reliable data from centres in different parts of the world, with various levels of surgeon evaluating radiographs at differing time intervals. We discuss the problem and suggest some methods of improvement


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 681 - 687
1 Sep 1993
Soballe K Toksvig-Larsen S Gelineck J Fruensgaard S Hansen E Ryd L Lucht U Bunger C

We allocated randomly 27 patients undergoing 28 primary uncemented total hip replacements (THR) to receive prosthetic components of similar design with either plasma-sprayed titanium alloy (Ti) coating (n = 13) or hydroxyapatite (HA) coating (n = 15). After some exclusions, 15 of the patients (15 THR; 7 with HA- and 8 with Ti-coating) were followed by roentgen stereophotogrammetric analysis at 3, 6 and 12 months to measure migration of the femoral component. Twenty-six of the patients (26 THR) were followed clinically and by conventional radiography. All the femoral components had migrated at 3 months. From 3 to 12 months, the migration of Ti-coated components continued whereas the HA-coated components had stabilised. At 12 months there was significantly less migration of the HA-coated components (p < 0.05). The maximum subsidence was 0.2 mm in both groups. The Harris hip score was equal in the two groups preoperatively but at follow-up it was better in the HA-coated group (p < 0.05) and visual analogue scale scores showed that they had less pain (p < 0.05)


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 896 - 899
1 Nov 1997
Fender D Harper WM Thompson JR Gregg PJ

We calculated the rates for perioperative mortality and fatal pulmonary embolism (PE) after primary total hip replacement in a single UK health region, using a regional arthroplasty register and the tracing service of the Office of National Statistics. During 1990, there were 2111 consecutive primary replacements in 2090 separate procedures. Within 42 days of operation a total of 19 patients had died (0.91%, 95% CI 0.55 to 1.42). Postmortem examination showed that four deaths (0.19%, 95% CI 0.05 to 0.49) were definitely due to PE. The overall perioperative mortality and fatal PE rates are low and in our study did not appear to be altered by the use of chemical thromboprophylaxis (perioperative mortality rate: one-tailed Fisher’s exact test, p = 0.39; fatal PE rate: one-tailed Fisher’s exact test, p = 0.56). The routine use of chemical thromboprophylaxis for primary THR is still controversial. The issue should be addressed by an appropriate randomised, prospective study using overall mortality and fatal PE rate as the main outcome measures, but the feasibility of such a study is questioned


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 899 - 902
1 Nov 1996
Weale AE Newman P Ferguson IT Bannister GC

Nerve injury is a rare complication of total hip replacement which may be related to the exposure used for the operation. The posterior approach is traditionally associated with injury to the sciatic nerve. We have compared the incidence of nerve injury after primary total hip replacement (THR) using either a posterior or a direct lateral approach. We studied 42 consecutive patients undergoing primary total hip replacement. The surgeons used a posterior (22 patients) or direct lateral (20 patients) approach in accordance with their normal practice. The obturator, femoral, posterior tibial and common peroneal nerves were assessed clinically and electrophysiologically by electromyography (EMG) and measurement of the velocity of nerve conduction before operation and at four weeks after. All patients were free from symptoms of nerve injury after operation but five lesions were identified in four patients by the electrophysiological studies; the obturator nerve was involved in two, the femoral in one, the common peroneal in one and the posterior tibial in one. All these injuries occurred using the lateral approach. Clinical assessment alone underestimates the incidence of nerve injury complicating THR. Our study does not confirm the association of nerve injury with the posterior approach which had been described previously


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 546 - 549
1 Jul 1996
Haddad FS Cobb AG Bentley G Levell NJ Dowd PM

Aseptic loosening is seen in a significant proportion of cemented total hip replacements (THR). In a small subgroup of patients who suffer early loosening polyethylene debris is unlikely to be responsible. We recently reported one case of allergic contact dermatitis to N,N-dimethylparatoluidine (DMT), an accelerator used in bone cement. We have therefore investigated this using skin-patch tests to a variety of substances including metals, polyethylene and the separated individual components of Simplex cement. We studied 70 patients, 15 with aseptic loosening less than two years after THR, 25 with satisfactory long-term cemented fixation, five with infected loosening of cemented THRs and 25 awaiting hip arthroplasty. We found seven positive reactions to DMT, all of them in patients with the rapid onset of aseptic loosening. Allergy to DMT is recognised in the dental profession in respect of the ‘denture sore mouth’ syndrome, and could also be an occupational hazard since some industrial glues contain DMT. Our results suggest the need for awareness of possible previous dental or occupational exposure to the constituents of bone cement. We recommend the use of skin-patch testing in high-risk cases