Chen TH Chen WM Huang CK

We reviewed 29 patients who had undergone intercalary resection for malignant tumours. Of these, 14 had received segmental allograft reconstruction and 15 extracorporeally-irradiated autograft.

At a mean follow-up of 71 months (24 to 132), 20 were free from disease, five had died and four were alive with pulmonary metastases. Two patients, one with an allograft and one with an irradiated autograft, had a local recurrence. Reconstruction with extracorporeally-irradiated autograft has a significantly lower rate of nonunion (7% vs 43%, p = 0.031) but an insignificantly higher rate of fracture (20% vs 14%, p = 0.535) than that with segmental allograft. Using the Enneking functional evaluation system, the mean postoperative score for the patients without local recurrence was 87% (80% to 96%) and was similar in both groups.

Extracorporeally-irradiated autograft could be an acceptable alternative for reconstruction after intercalary resection, especially in countries where it is difficult to obtain allografts.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 469 - 474
1 Apr 2009
Gulati A Pandit H Jenkins C Chau R Dodd CAF Murray DW

Varus malalignment after total knee replacement is associated with a poor outcome. Our aim was to determine whether the same was true for medial unicompartmental knee replacement (UKR). The anatomical leg alignment was measured prospectively using a long-arm goniometer in 160 knees with an Oxford UKR. Patients were then grouped according to their mechanical leg alignment as neutral (5° to 10° of valgus), mild varus (0° to 4° of valgus) and marked varus (> 0° of varus). The groups were compared at five years in terms of absolute and change in the Oxford Knee score, American Knee Society score and the incidence of radiolucent lines.

Post-operatively, 29 (18%) patients had mild varus and 13 (8%) had marked varus. The mean American Knee Society score worsened significantly (p < 0.001) with increasing varus. This difference disappeared if a three-point deduction for each degree of malalignment was removed. No other score deteriorated with increasing varus, and the frequency of occurrence of radiolucent lines was the same in each group.

We therefore conclude that after Oxford UKR, about 25% of patients have varus alignment, but that this does not compromise their clinical or radiological outcome. Following UKR the deductions for malalignment in the American Knee Society score are not justified.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 859 - 864
1 Jul 2009
Gwynne-Jones DP Garneti N Wainwright C Matheson JA King R

We reviewed the results at nine to 13 years of 125 total hip replacements in 113 patients using the monoblock uncemented Morscher press-fit acetabular component. The mean age at the time of operation was 56.9 years (36 to 74). The mean clinical follow-up was 11 years (9.7 to 13.5) and the mean radiological follow-up was 9.4 years (7.7 to 13.1). Three hips were revised, one immediately for instability, one for excessive wear and one for deep infection.

No revisions were required for aseptic loosening. A total of eight hips (7.0%) had osteolytic lesions greater than 1 cm, in four around the acetabular component (3.5%). One required bone grafting behind a well-fixed implant. The mean wear rate was 0.11 mm/year (0.06 to 0.78) and was significantly higher in components with a steeper abduction angle.

Kaplan-Meier survival curves at 13 years showed survival of 96.8% (95% confidence interval 90.2 to 99.0) for revision for any cause and of 95.7% (95% confidence interval 88.6 to 98.4) for any acetabular re-operation.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 889 - 895
1 Jul 2009
Gandhi R Tsvetkov D Davey JR Mahomed NN

Using meta-analysis we compared the survival and clinical outcomes of cemented and uncemented techniques in primary total knee replacement. We reviewed randomised controlled trials and observational studies comparing cemented and uncemented fixation. Our primary outcome was survival of the implant free of aseptic loosening. Our secondary outcome was joint function as measured by the Knee Society score. We identified 15 studies that met our final eligibility criteria. The combined odds ratio for failure of the implant due to aseptic loosening for the uncemented group was 4.2 (95% confidence interval (CI) 2.7 to 6.5) (p < 0.0001). Subgroup analysis of data only from randomised controlled trials showed no differences between the groups for odds of aseptic loosening (odds ratio 1.9, 95% CI 0.55 to 6.40, p = 0.314). The weighted mean difference for the Knee Society score was 0.005 (95% CI −0.26 to 0.26) (p = 0.972).

There was improved survival of the cemented compared to uncemented implants, with no statistically significant difference in the mean Knee Society score between groups for all pooled data.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 940 - 945
1 Jul 2005
Pandit H Ward T Hollinghurst D Beard DJ Gill HS Thomas NP Murray DW

Abnormal sagittal kinematics after total knee replacement (TKR) can adversely affect functional outcome. Two important determinants of knee kinematics are component geometry and the presence or absence of a posterior-stabilising mechanism (cam-post). We investigated the influence of these variables by comparing the kinematics of a TKR with a polyradial femur with a single radius design, both with and without a cam-post mechanism.

We assessed 55 patients, subdivided into four groups, who had undergone a TKR one year earlier by using an established fluoroscopy protocol in order to examine their kinematics in vivo. The kinematic profile was obtained by measuring the patellar tendon angle through the functional knee flexion range (0° to 90°) and the results compared with 14 normal knees. All designs of TKR had abnormal sagittal kinematics compared with the normal knee. There was a significant (p < 0.05) difference between those of the two TKRs near to full extension. The presence of the cam-post mechanism did not influence the kinematics for either TKR design. These differences suggest that surface geometry is a stronger determinant of kinematics than the presence or absence of a cam-post mechanism for these two designs. This may be because the cam-post mechanism is ineffective.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 496 - 500
1 Apr 2005
Mileti J Sperling JW Cofield RH Harrington JR Hoskin TL

There are theoretical and practical advantages to modular rather than monoblock designs of prostheses for shoulder arthroplasty, but there are no reported studies which specifically compare the clinical and radiological results of their use. We have compared the results of unconstrained total shoulder arthroplasty for osteoarthritis using both types of implant. The monoblock design was used between 1992 and 1995 and the modular design after 1995. Both had cemented all-polyethylene glenoids, the monoblock with matched and the modular with mismatched radii of curvature. There were 34 consecutive shoulders in each group with a mean follow-up of 6.1 years in the first and 5.2 years in the second.

There were no significant differences in improvement of pain scores, active elevation, external rotation, internal rotation, patient satisfaction, or the Neer ratings between the two groups. Two of 28 glenoid components in the first group and six of 30 in the second met the criteria for being radiologically at risk for loosening (p = 0.25). There were no significant differences in clinical outcome or radiological changes between the first- and second-generation designs of implant for shoulder arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1096 - 1101
1 Aug 2005
Maynou C Cassagnaud X Mestdagh H

We compared the long-term function of subscapularis after the Latarjet procedure using two surgical approaches. We treated 102 patients (106 shoulders) with a mean age of 26.8 years (15 to 51) with involuntary unidirectional recurrent instability. The operation was carried out through an L-shaped incision with trans-section of the upper two-thirds of the muscle in 69 cases and with a subscapularis split in 37. All clinical results were assessed by the Rowe and the Duplay scores and the function of subscapularis by evaluating the distance and strength at the lift-off position. Bilateral CT was performed in 77 patients for assessment of fatty degeneration. The mean follow-up was 7.5 years (2 to 15) and 18% of cases were lost to follow-up. The mean Duplay score was 82 of 100 for the L-shaped incision group and 90 of 100 for those with a subscapularis split (p = 0.02). The mean fatty degeneration score was 1.18 after an L-shaped incision compared with 0.12 after subscapularis split (p = 0.001). The subscapularis split approach is therefore recommended.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 698 - 703
1 May 2005
Katagiri H Takahashi M Wakai K Sugiura H Kataoka T Nakanishi K

Between 1992 and 1999, we treated 350 patients with skeletal metastases. A multivariable analysis of the patients was conducted using the Cox proportional hazards model. We identified five significant prognostic factors for survival, namely, the site of the primary lesion, the performance status (Eastern Cooperative Oncology Group status 3 or 4), the presence of visceral or cerebral metastases, any previous chemotherapy, and multiple skeletal metastases. The score for each significant factor was derived from the corresponding estimated regression coefficients (natural logarithm of the hazard ratio). The prognostic score was calculated by adding all the scores for individual factors.

The rate of survival was 31% at six months and 11% at one year for the patients with a prognostic score of 6 or more. By contrast, patients with a prognostic score of 2 or less had a rate of survival of 98% at six months and 89% at one year. This scoring system can be used to determine the optimal treatment for patients with pathological fractures or epidural compression.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 713 - 719
1 Jun 2009
Denaro V Papalia R Denaro L Di Martino A Maffulli N

Cervical spinal disc replacement is used in the management of degenerative cervical disc disease in an attempt to preserve cervical spinal movement and to prevent adjacent disc overload and subsequent degeneration. A large number of patients have undergone cervical spinal disc replacement, but the effectiveness of these implants is still uncertain. In most instances, degenerative change at adjacent levels represents the physiological progression of the natural history of the arthritic disc, and is unrelated to the surgeon. Complications of cervical disc replacement include loss of movement from periprosthetic ankylosis and ossification, neurological deficit, loosening and failure of the device, and worsening of any cervical kyphosis. Strict selection criteria and adherence to scientific evidence are necessary. Only prospective, randomised clinical trials with long-term follow-up will establish any real advantage of cervical spinal disc replacement over fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1110 - 1119
1 Aug 2009
Hepp P Osterhoff G Niederhagen M Marquass B Aigner T Bader A Josten C Schulz R

Perilesional changes of chronic focal osteochondral defects were assessed in the knees of 23 sheep. An osteochondral defect was created in the main load-bearing region of the medial condyle of the knees in a controlled, standardised manner. The perilesional cartilage was evaluated macroscopically and biopsies were taken at the time of production of the defect (T0), during a second operation one month later (T1), and after killing animals at three (T3; n = 8), four (T4; n = 8), and seven (T7; n = 8) months. All the samples were histologically assessed by the International Cartilage Repair Society grading system and Mankin histological scores. Biopsies were taken from human patients (n = 10) with chronic articular cartilage lesions and compared with the ovine specimens. The ovine perilesional cartilage presented with macroscopic and histological signs of degeneration. At T1 the International Cartilage Repair Society ‘Subchondral Bone’ score decreased from a mean of 3.0 (sd 0) to a mean of 1.9 (sd 0.3) and the ‘Matrix’ score from a mean of 3.0 (sd 0) to a mean of 2.5 (sd 0.5). This progressed further at T3, with the International Cartilage Repair Society ‘Surface’ grading, the ‘Matrix’ grading, ‘Cell Distribution’ and ‘Cell Viability’ grading further decreasing and the Mankin score rising from a mean of 1.3 (sd 1.4) to a mean of 5.1 (sd 1.6). Human biopsies achieved Mankin grading of a mean of 4.2 (sd 1.6) and were comparable with the ovine histology at T1 and T3.

The perilesional cartilage in the animal model became chronic at one month and its histological appearance may be considered comparable with that seen in human osteochondral defects after trauma.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 310 - 315
1 Mar 2009
Olsen M Davis ET Waddell JP Schemitsch EH

We have investigated the accuracy of placement of the femoral component using imageless navigation in 100 consecutive Birmingham Hip Resurfacings. Pre-operative templating determined the native neck-shaft angle and planned stem-shaft angle of the implant. The latter were verified post-operatively using digital anteroposterior unilateral radiographs of the hip.

The mean neck-shaft angle determined before operation was 132.7° (118° to 160°). The mean planned stem-shaft angle was a relative valgus alignment of 9.7° (sd 2.6). The stem-shaft angle after operation differed from that planned by a mean of 2.8° (sd 2.0) and in 86% of cases the final angle measured within ± 5° of that planned. We had no instances of notching of the neck or varus alignment of the implant in our series. A learning curve was observed in the time taken for navigation, but not for accurate placement of the implant.

Navigation in hip resurfacing may afford the surgeon a reliable and accurate method of placement of the femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 351 - 356
1 Mar 2009
Parratte S Argenson JA Pearce O Pauly V Auquier P Aubaniac J

We retrospectively reviewed 35 cemented unicompartmental knee replacements performed for medial unicompartmental osteoarthritis of the knee in 31 patients ≤50 years old (mean 46, 31 to 49). Patients were assessed clinically and radiologically using the Knee Society scores at a mean follow-up of 9.7 years (5 to 16) and survival at 12 years was calculated. The mean Knee Society Function Score improved from 54 points (25 to 64) pre-operatively to 89 (80 to 100) post-operatively (p < 0.0001). Six knees required revision, four for polyethylene wear treated with an isolated exchange of the tibial insert, one for aseptic loosening and one for progression of osteoarthritis.

The 12-year survival according to Kaplan-Meier was 80.6% with revision for any reason as the endpoint. Despite encouraging clinical results, polyethylene wear remains a major concern affecting the survival of unicompartmental knee replacement in patients younger than 50.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 885 - 888
1 Jul 2008
Thomason K Eyres KS

Salvage of a failed total ankle replacement is technically challenging and although a revision procedure may be desirable, a large amount of bone loss or infection may preclude this. Arthrodesis can be difficult to achieve and is usually associated with considerable shortening of the limb.

We describe a technique for restoring talar height using an allograft from the femoral head compressed by an intramedullary nail. Three patients with aseptic loosening were treated successfully by this method with excellent symptomatic relief at a mean follow-up of 32 months (13 to 50).


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1055 - 1058
1 Aug 2008
Lee HS Kim JS Park S Lee D Park JM Wapner KL

We studied 11 patients with checkrein deformities of the hallux who underwent surgical treatment. Six had lengthening of the flexor hallucis longus tendon by Z-plasty in the midfoot, and five underwent release of adhesions and lengthening of the tendon by Z-plasty at the musculotendinous junction at the fracture site.

All six patients who underwent Z-plasty at the midfoot showed complete correction of the deformity without recurrence. Of the five who had release of adhesions and Z-plasty of the tendon at the fracture site, two showed partial and one showed complete recurrence.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 91 - 96
1 Jan 2009
Labbe J Peres O Leclair O Goulon R Scemama P Jourdel F

We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These unstable fractures need early posterior stabilisation and fusion or, if treated conservatively, a very close follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 52 - 57
1 Jan 2009
Newman J Pydisetty RV Ackroyd C

Between 1989 and 1992 we had 102 knees suitable for unicompartmental knee replacement (UKR). They were randomised to receive either a St Georg Sled UKR or a Kinematic modular total knee replacement (TKR). The early results demonstrated that the UKR group had less complications and more rapid rehabilitation than the TKR group. At five years there were an equal number of failures in the two groups but the UKR group had more excellent results and a greater range of movement.

The cases were reviewed by a research nurse at 8, 10 and 12 years after operation. We report the outcome at 15 years follow-up. A total of 43 patients (45 knees) died with their prosthetic knees intact. Throughout the review period the Bristol knee scores of the UKR group have been better and at 15 years 15 (71.4%) of the surviving UKRs and 10 (52.6%) of the surviving TKRs had achieved an excellent score. The 15 years survivorship rate based on revision or failure for any reason was 24 (89.8%) for UKR and 19 (78.7%) for TKR. During the 15 years of the review four UKRs and six TKRs failed.

The better early results with UKR are maintained at 15 years with no greater failure rate. The median Bristol knee score of the UKR group was 91.1 at five years and 92 at 15 years, suggesting little functional deterioration in either the prosthesis or the remainder of the joint. These results justify the increased use of UKR.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 234 - 239
1 Feb 2009
Puri A Subin BS Agarwal MG

We evaluated the results of fibular centralisation as a stand alone technique to reconstruct defects that occurred after resection of tumours involving the tibial diaphysis and distal metaphysis.

Between January 2003 and December 2006, 15 patients underwent excision of tumours of the tibial diaphysis or distal metaphysis and reconstruction by fibular centralisation. Their mean age was 17 years (7 to 40). Two patients were excluded; one died from the complications of chemotherapy and a second needed a below-knee amputation for a recurrent giant-cell tumour. A total of 13 patients were reviewed after a mean follow-up of 29 months (16 to 48). Only 16 of 26 host graft junctions united primarily. Ten junctions in ten patients needed one or more further procedure before union was achieved. At final follow-up 12 of the 13 patients had fully united grafts; 11 walked without aids. The mean time to union at the junctions that united was 12 months (3 to 36). The mean Musculoskeletal Tumor Society Score was 24.7 (16 to 30).

Fibular centralisation is a durable reconstruction for defects of the tibial diaphysis and distal metaphysis with an acceptable functional outcome. Stable osteosynthesis is the key to successful union. Additional bone grafting is recommended for patients who need postoperative radiotherapy.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 47 - 53
1 Jan 2005
Whaley A Morrey BF Adams R

We examined the effects of previous resection of the radial head and synovectomy on the outcome of subsequent total elbow arthroplasty in patients with rheumatoid arthritis.

Fifteen elbows with a history of resection and synovectomy were compared with a control group of patients who had elbow arthroplasty with an implant of the same design. The mean age in both groups was 63 years. In the study group, resection of the radial head and synovectomy had been undertaken at a mean of 8.9 years before arthroplasty. The mean radiological follow-up for the 13 available patients in the study group was 5.89 years (0.3 to 11.0) and in the control group was 6.6 years (2.2 to 12.6). There were no revisions in either group. The mean Mayo elbow performance score improved from 29 to 96 in the study group, with similar improvement in the control group (28 to 87). The study group had excellent results in 13 elbows and good results in two. The control group had excellent results in seven and good results in six.

Our experience indicates that previous resection of the radial head and synovectomy are not associated with an increased rate of revision following subsequent arthroplasty of the elbow. However, there was a higher rate of complication in the study group compared with the control group.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 82 - 87
1 Jan 2009
Charalambous CP Stanley JK Siddique I Aster A Gagey O

The lateral ligament complex is the primary constraint to posterolateral rotatory laxity of the elbow, and if it is disrupted during surgery, posterolateral instability may ensue. The Wrightington approach to the head of the radius involves osteotomising the ulnar insertion of this ligament, rather than incising through it as in the classic posterolateral (Kocher) approach. In this biomechanical study of 17 human cadaver elbows, we demonstrate that the surgical approach to the head can influence posterolateral laxity, with the Wrightington approach producing less posterolateral rotatory laxity than the posterolateral approach.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 395 - 400
1 Mar 2009
Krieg AH Mani M Speth BM Stalley PD

We review the treatment of pelvic Ewing’s sarcoma by the implantation of extracorporeally-irradiated (ECI) autografts and compare the outcome with that of other reported methods.

We treated 13 patients with ECI autografts between 1994 and 2004. There were seven males and six females with a median age of 15.7 years (interquartile range (IQR) 12.2 to 21.7). At a median follow-up of five years (IQR 1.8 to 7.4), the disease-free survival was 69% overall, and 75% if one patient with local recurrence after initial treatment elsewhere was excluded. Four patients died from distant metastases at a mean of 17 months (13 to 23). There were three complications which required operative intervention; one was a deep infection which required removal of the graft. The functional results gave a mean Musculoskeletal Tumor Society score of 85% (60% to 97%), a mean Toronto extremity salvage score of 86% (69% to 100%) and a mean Harris hip score of 92 (67 to 100).