Advertisement for orthosearch.org.uk
Results 181 - 200 of 1896
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 149 - 149
1 Jan 2004
FRÖLKE JPM REELING BROUWER GC


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 169 - 169
1 Jan 1996
Kenwright J


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 812 - 816
1 Nov 1987
Lynch M Taylor J

Growth at the proximal tibial epiphyseal plate of the rat has been measured following three different growth-stimulating procedures. These were proximal periosteal release, distal periosteal release and full periosteal stripping of the diaphysis. A new radiographic method using a photographic technique has made it possible to take accurate measurements of the rate of long-bone growth in small experimental animals. From the results of this animal series we conclude that proximal tibial periosteal division is likely to be the most effective of the three procedures when used to correct leg-length discrepancy in the growing child.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 441 - 447
1 May 1987
Smith M Jones E Strachan R Nicoll J Best J Tothill P Hughes S

The uptake of 99mTc-MDP was studied in 73 patients after a tibial fracture. The image obtained five minutes after injection during a period between one and four weeks after fracture was found to be related to the incidence of non-union after six months. A ratio of 1.3 between the uptake at the fracture site and at normal bone adjacent to it predicted non-union in an individual patient with a sensitivity of about 70% and a specificity of 90%.


The Journal of Bone & Joint Surgery British Volume
Vol. 43-B, Issue 4 | Pages 672 - 679
1 Nov 1961
Forbes DB

The use of a subcortical graft of autogenous iliac bone in patients with delayed union or non-union of fractured tibiae is described together with the results in twenty-nine patients. This procedure when performed early even in the presence of mild sepsis makes it possible to shorten the time of healing without any undue risk.


The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 1 | Pages 185 - 203
1 Feb 1959
Morgan JD


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 1 | Pages 83 - 94
1 Feb 1956
Burrows HJ

1. A defect of the middle of one tibial crest is described in young healthy ballet dancers.

2. The clinical and radiological characteristics have been studied in four cases, and the histological appearances in two.

3. The defect is concluded to be an incomplete fatigue fracture—a fatigue infraction.

4. A fifth, uncertain, case has been added tentatively, as presenting a possible serious complication, namely acute fracture from muscle action.

5. The diagnosis, treatment and prognosis are mentioned, with emphasis on the importance of adequate clinical and radiological examination in cases of obscure mid-tibial pain, tenderness or swelling.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 370 - 375
1 May 1990
Burr D Milgrom C Boyd R Higgins W Robin G Radin E

We have shown that stress fractures can be induced in the tibial diaphysis of an animal model by the repeated application of non-traumatic impulsive loads. The right hind limbs of 31 rabbits were loaded for three to nine weeks and changes in the bone were monitored by radiography and bone scintigraphy. The presence of stress fractures was confirmed histologically in some cases. Most animals sustained a stress fracture within six weeks and there was a positive correspondence between scintigraphic change and radiological evidence. Microscopic damage was evident at the sites of positive bone scans. The progression, location, and time of onset of stress fractures in this animal model were similar to those in clinical reports, making the model a useful one for the study of the aetiology of stress fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 309 - 311
1 Mar 1990
De Santis G Williams J Dvir E O'Brien B Hurley J Goldberg I

A dose of 48 Gy of X-irradiation given over two to five weeks after grafting caused no significant delay in the rate of healing and only a small and statistically non-significant decrease in the torsional strength of the graft-bone junction of either vascularised or non-vascularised bone grafts of the tibiae of rabbits. Healing was faster and the union between the graft and adjacent bone developed torsional strength significantly more rapidly with vascularised than with non-vascularised grafts. These findings suggest that postoperative radiotherapy is unlikely to have a significantly deleterious effect on the healing of bone grafts used to repair defects produced by excision of malignant bone tumours.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 246 - 254
1 Mar 1986
Behrens F Searls K

External fixation of fractures of the leg may give uneven results and a high rate of complications. We postulate that three basic principles can govern the optimal use of these devices. The external fixation frame should avoid damage to vital anatomical structures, it should allow access to the injured area and it should meet the mechanical demands of the patient and the injury. From 1978 to 1981 these principles were evaluated prospectively in 75 consecutive cases of complex tibial injury treated with an external frame. Most were open fractures. The study confirmed that the principles were safe and effective; they have general application and do not depend on the use of a particular frame or device. By following them we have eliminated the majority of complications seen after traditional methods of external fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 385 - 387
1 Mar 2009
Pichler W Grechenig W Tesch NP Weinberg AM Heidari N Clement H

Percutaneous stabilisation of tibial fractures by locking plates has become an accepted form of osteosynthesis. A potential disadvantage of this technique is the risk of damage to the neurovascular bundles in the anterior and peroneal compartments. Our aim in this anatomical study was to examine the relationship of the deep peroneal nerve to a percutaneously-inserted Less Invasive Stabilisation System tibial plate in the lower limbs of 18 cadavers. Screws were inserted through stab incisions. The neurovascular bundle was dissected to reveal its relationship to the plate and screws.

In all cases, the deep peroneal nerve was in direct contact with the plate between the 11th and the 13th holes. In ten specimens the nerve crossed superficial to the plate, in six it was interposed between the plate and the bone and in the remaining two specimens it coursed at the edge of the plate.

Percutaneous insertion of plates with more than ten holes is not recommended because of the risk of injury to the neurovascular structures. When longer plates are required we suggest distal exposure so that the neurovascular bundle may be displayed and protected.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 462 - 466
1 May 1986
Bostman O

We have analysed the initial displacement and the retention of position after reduction of 192 spiral fractures of the tibial shaft. In fractures with an initial lateral displacement of one half the width of the shaft or more, successful retention of position after the primary closed reduction was achieved in only 18%. The direction of displacement between the tibial fragments showed little variation; the proximal fragment was always medial and anterior to the distal. This resulted in an increased space between the proximal tibial fragment and the shaft of the fibula in the plane of the interosseous membrane. There was a strong correlation between the initial displacement and the initial shortening. No evidence of a posterior soft-tissue hinge, able to facilitate closed reduction, could be found. Consequently, in treating severely displaced spiral fractures, open reduction and internal fixation or a few weeks' initial calcaneal traction seem to be the rational alternatives.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 2 | Pages 178 - 184
1 May 1981
Dekel S Francis M

Osteomyelitis was induced in the tibiae of rabbits by injecting a suspension of Staphylococcus aureus and sodium tetradecylsulphate, a sclerosing agent. These rabbits were then divided into two groups: one group remained untreated and the other was fed a diet containing sodium salicylate. Two and four weeks after induction of osteomyelitis the tibiae taken from untreated rabbits with osteomyelitis and incubated in vitro released significantly more prostaglandin E and F than the control uninjected or uninfected tibiae. Tibiae taken from rabbits treated with sodium salicylate showed minimal radiographic changes and a significantly decreased release of prostaglandin E and F compared to the untreated rabbits. Prostaglandins are known to be potent bone resorbing agents and the results of this study suggest that they may also be involved in the destruction of bone which is characteristic of osteomyelitis. The treatment of rabbits with osteomyelitis using anti-inflammatory drugs, which block synthesis of prostaglandins, in addition to antibiotics, may prevent the destruction of bone and possible sequestration thereby decreasing the risk of chronic disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 1 | Pages 31 - 39
1 Feb 1978
Jones D Barnes J Lloyd-Roberts G


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 495 - 499
1 Aug 1971
Pashayan H Fraser FC McIntyre JM Dunbar JS

1. A family is reported in which tibial aplasia with polydactyly of hands and feet and absent thumbs occurred in a father and daughter.

2. The evidence suggests the existence of an autosomal dominant mutant gene that causes absent thumbs and manual polydactyly, with or without varying degrees of tibial hypoplasia and pedal polydactyly.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 326 - 331
1 Apr 2000
Gaston P Will E McQueen MM Elton RA Court-Brown CM

We examined the recovery of power in the muscles of the lower limb after fracture of the tibial diaphysis, using a Biodex dynamometer. Recovery in all muscle groups was rapid for 15 to 20 weeks following fracture after which it slowed. Two weeks after fracture the knee flexors and extensors have about 40% of normal power, which rises to 75% to 85% after one year. The dorsiflexors and plantar flexors of the ankle and the invertors and evertors of the subtalar joint are much weaker two weeks after injury, but at one year their mean power is more than that of the knee flexors and extensors.

Our findings showed that age, the mode of injury, fracture morphology, the presence of an open wound and the Tscherne grade of closed fractures correlated with muscle power. It is age, however, which mainly determines muscle recovery after fracture of the tibial diaphysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 773 - 774
1 Jul 2001
MEHTA S WILLIAMS W


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 309 - 309
1 Mar 2001
STARR AJ


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 781 - 787
1 Sep 1995
Robinson C McLauchlan G McLean I Court-Brown C

We reviewed 63 patients with fractures of the distal tibial metaphysis, with or without minimally displaced extension into the ankle joint. The fractures had been caused by two distinct mechanisms, either a direct bending force or a twisting injury. This influenced the pattern of the fracture and its time to union. All fractures were managed by statically locked intramedullary nailing, with some modifications of the procedure used for diaphyseal fractures. There were few intra-operative complications. At a mean of 46 months, all but five patients had a satisfactory functional outcome. The poor outcomes were associated with either technical error or the presence of other injuries. We conclude that closed intramedullary nailing is a safe and effective method of managing these fractures.


Bone & Joint 360
Vol. 12, Issue 4 | Pages 32 - 35
1 Aug 2023

The August 2023 Trauma Roundup. 360. looks at: A comparison of functional cast and volar-flexion ulnar deviation for dorsally displaced distal radius fractures; Give your stable ankle fractures some AIR!; Early stabilization of rib fractures – an effective thing to do?; Locked plating versus nailing for proximal tibia fractures: A multicentre randomized controlled trial; Time to flap coverage in open tibia fractures; Does tranexamic acid affect the incidence of heterotropic ossification around the elbow?; High BMI – good or bad in surgical fixation of hip fractures?