Advertisement for orthosearch.org.uk
Results 181 - 200 of 4189
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 394 - 403
1 Aug 1978
Dunn D Angel J

The stages in adolescent slipping of the upper femoral epiphysis are classified in relation to treatment. The operation of open replacement of the displaced femoral head is described, and the results of a personal series of seventy-three such operations are presented. Open replacement is excellent treatment for severe chronic slipping so long as the growth plate is still open. The greater incidence of avascular necrosis in acute-on-chronic cases is probably due to damage to the blood supply of the head at the time of the acute slip or kinking of the vessels before replacement. Prolonged traction before operation may increase the risk of chondrolysis. Late onset of osteoarthritis when neither avascular necrosis nor chondrolysis has occurred may be due to misfitting of the articular cartilage because of inaccurate reduction


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 51 - 55
1 Jan 2012
Masterson S Lidder S Scott G

We report the long-term results of revision total hip replacement using femoral impaction allografting with both uncemented and cemented Freeman femoral components. A standard design of component was used in both groups, with additional proximal hydroxyapatite coating in the uncemented group. A total of 33 hips in 30 patients received an uncemented component and 31 hips in 30 patients a cemented component. The mean follow-up was 9.8 years (2 to 17) in the uncemented group and 6.2 years (1 to 11) in the cemented group. Revision procedures (for all causes) were required in four patients (four hips) in the uncemented group and in five patients (five hips) in the cemented group. Harris hip scores improved significantly in both groups and were maintained independently of the extent of any migration of the femoral component within the graft or graft–cement mantle


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 697 - 704
1 Sep 1993
Murray D Carr A Bulstrode C

Survival analysis is a powerful tool for analysing the results of total joint replacement, but it has major drawbacks when the failure rates are very low. We have reviewed 35 recent survival analyses of joint replacements to assess the magnitude of these problems and make recommendations as to how they may be avoided


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 604 - 607
1 Aug 1987
Beltran J

Resection arthroplasty of the patella has been found to be a satisfactory procedure for the treatment of patellofemoral pain caused by osteoarthritis. In the present series 60% of the operated cases were pain-free on a 31-month average follow-up. The patients found it easier to climb stairs and to kneel and in most cases the radiographic joint space was good


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1052 - 1056
1 Aug 2013
Lampropoulou-Adamidou K Georgiades G Vlamis J Hartofilakidis G

We evaluated the outcome of 41 consecutive Charnley low-friction arthroplasties (LFAs) performed by a single surgeon in 28 patients aged ≤ 35 years at operation between 23 and 36 years previously. There were 20 women and eight men with a mean age of 32 years (23 to 35) at surgery. Two patients (three hips) were lost to follow-up at 12 and 17 years post-operatively, respectively, and one patient (one hip) died at 13 years post-operatively. These patients were excluded from the final evaluation. The survival rate of the acetabular components was 92.7% (95% confidence interval (CI) 88.7 to 96.7) at ten years, 67.1% (95% CI 59.75 to 74.45) at 20 years and 53.2% (95% CI 45.3 to 61.1) at 25 years. For the femoral component the survival was 95.1% (95% CI 91.8 to 98.5) at ten years, 77.1% (95% CI 73.9 to 80.3) at 20 years and 68.2% (95% CI 60.7 to 75.8) at 25 years. The results indicate that the Charnley LFA remains a reasonable choice in the treatment of young patients and can serve for comparison with newer techniques and implants. Cite this article: Bone Joint J 2013;95-B:1052–6


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1019 - 1024
1 Aug 2007
Hing CB Young DA Dalziel RE Bailey M Back DL Shimmin AJ

Narrowing of the femoral neck after resurfacing arthroplasty of the hip has been described previously in both cemented and uncemented hip resurfacing. The natural history of narrowing of the femoral neck is unknown. We retrospectively measured the diameter of the femoral neck in a series of 163 Birmingham hip resurfacings in 163 patients up to a maximum of six years after operation to determine the extent and progression of narrowing. There were 105 men and 58 women with a mean age of 52 years (18 to 82). At a mean follow-up of five years, the mean Harris hip score was 94.8 (47 to 100) and the mean flexion of the hip 112.5° (80° to 160°). There was some narrowing of the femoral neck in 77% (125) of the patients reviewed, and in 27.6% (45) the narrowing exceeded 10% of the diameter of the neck. A multiple logistic regression analysis showed a significant association (chi-squared test (derived from logistic regression) p = 0.01) of narrowing with female gender and a valgus femoral neck/shaft angle. There was no significant association between the range of movement, position or size of the component or radiological lucent lines and narrowing of the neck (chi-squared test; p = 0.10 (flexion), p = 0.08 (size of femoral component), p = 0.09 (size of acetabular component), p = 0.71 (femoral component angulation), p = 0.99 (lucent lines)). There was no significant difference between the diameter of the neck at a mean of three years (2.5 to 3.5) and that at five years (4.5 to 5.5), indicating that any change in the diameter of the neck had stabilised by three years (sign rank test, p = 0.60). We conclude that narrowing of the femoral neck which is found with the Birmingham hip resurfacing arthroplasty is in most cases associated with no adverse clinical or radiological outcome up to a maximum of six years after the initial operation


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 374 - 380
1 Mar 2016
Kocsis G Thyagarajan DS Fairbairn KJ Wallace WA

Aims. Glenoid bone loss can be a challenging problem when revising a shoulder arthroplasty. Precise pre-operative planning based on plain radiographs or CT scans is essential. We have investigated a new radiological classification system to describe the degree of medialisation of the bony glenoid and that will indicate the amount of bone potentially available for supporting a glenoid component. It depends on the relationship between the most medial part of the articular surface of the glenoid with the base of the coracoid process and the spinoglenoid notch: it classifies the degree of bone loss into three types. It also attempts to predict the type of glenoid reconstruction that may be possible (impaction bone grafting, structural grafting or simple non-augmented arthroplasty) and gives guidance about whether a pre-operative CT scan is indicated. Patients and Methods. Inter-method reliability between plain radiographs and CT scans was assessed retrospectively by three independent observers using data from 39 randomly selected patients. . Inter-observer reliability and test-retest reliability was tested on the same cohort using Cohen's kappa statistics. Correlation of the type of glenoid with the Constant score and its pain component was analysed using the Kruskal-Wallis method on data from 128 patients. Anatomical studies of the scapula were reviewed to explain the findings. Results. Excellent inter-method reliability, inter-observer and test-retest reliability were seen. The system did not correlate with the Constant score, but correlated well with its pain component. . Take home message: Our system of classification is a helpful guide to the degree of glenoid bone loss when embarking on revision shoulder arthroplasty. Cite this article: Bone Joint J 2016;98-B:374–80


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 682 - 684
1 Nov 1984
Inglis G

A retrospective review of medial compartment arthroplasty in 22 patients (22 knees) is reported. The operations were performed between 1973 and 1978. Eighty-six per cent were rated good or excellent using the knee rating system devised by the Hospital for Special Surgery, New York. Excellent or good results were achieved in six patients who had previously had a high tibial osteotomy. At the time of follow-up significant loosening had not occurred, although progression of patellofemoral disease was noted. This study supports the promising results reported for unicompartmental resurfacing arthroplasty in the elderly


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 371 - 374
1 May 1993
Glithero P Grigoris P Harding L Hesslewood McMinn D

We report the results of imaging with labelled white cells in 52 patients before the revision of 54 cemented joint prostheses at which the diagnosis of infection was made from biopsies. Twenty-five hips were imaged with 111In-oxine-labelled cells; 20 hips and 11 knees were imaged with 99mTc-hexamethylpropylene-amineoxime-labelled cells. Of these, 13 hips and five knees proved to be infected. The scans taken together had an accuracy of 82%, a sensitivity of 44% and a specificity of 100%. Indium scans gave 37% sensitivity, 99mTc labelling 50% sensitivity. Infected arthroplasties with positive scans had presented significantly earlier than those with negative scans, the time after the original insertion being 1.1 years for the true-positive scans and 6.1 years for the false-negative scans. The value of labelled white-cell scans in the detection of infection in failed joint replacements is dependent on the activity of the infection. There is reduced sensitivity to the more insidious infections which affect arthroplasties and aspiration under controlled conditions remains an important investigation


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1143 - 1151
1 Sep 2008
Langton DJ Jameson SS Joyce TJ Webb J Nargol AVF

Increased concentrations of metal ions after metal-on-metal resurfacing arthroplasty of the hip remain a concern. Although there has been no proven link to long-term health problems or early prosthetic failure, variables associated with high metal ion concentrations should be identified and, if possible, corrected. Our study provides data on metal ion levels from a series of 76 consecutive patients (76 hips) after resurfacing arthroplasty with the Articular Surface Replacement. Chromium and cobalt ion concentrations in the whole blood of patients with smaller (≤ 51 mm) femoral components were significantly higher than in those with the larger (≥ 53 mm) components (p < 0.01). Ion concentrations in the former group were significantly related to the inclination (p = 0.01) and anteversion (p = 0.01) of the acetabular component. The same relationships were not significant in the patients with larger femoral components (p = 0.61 and p = 0.49, respectively). Accurate positioning of the acetabular component intra-operatively is essential in order to reduce the concentration of metal ions in the blood after hip resurfacing arthroplasty with the Articular Surface Replacement implant


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 300 - 304
1 Aug 1976
Watson Wood H Hill R

Thirty-one patients with rheumatoid arthritis were reviewed after Shiers arthroplasty of the knee joint for which the main indication was intractable pain. Seven patients had the operation done to both knees. This review was done to assess the long-term results two to seven years later. All patients were clinically and radiologically assessed, and our results showed that pain and instability recurred within eighteen months. Thus it is likely that a prosthesis which allows rotation, and in which the bearing surfaces are metal on plastic, will replace the Shiers prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 616 - 623
1 Jul 1993
Joshi A Porter M Trail I Hunt L Murphy J Hardinge K

We report the long-term outcome of 218 Charnley low-friction arthroplasties in 141 patients who were 40 years old or younger at the time of surgery. The minimum follow-up was ten years with a mean of 16 years. The probability of the femoral component surviving 20 years was 86% and of the acetabular component, 84%. The chance that both components would survive for this period was 75%. The pathological diagnosis significantly influenced implant survival. In rheumatoid patients the probability of both components surviving at 20 years was 96% compared with 51% in patients with osteoarthritis. Clinical assessment of 103 patients (166 hips) in whom the arthroplasty was still functioning showed that 94% of hips had minimal pain or none. We conclude that in young patients cemented total hip replacement is a good procedure for those with rheumatoid arthritis but that the results are much less reliable in those with osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 35 - 39
1 Jan 2006
Beaulé PE Campbell PA Hoke R Dorey F

During hip resurfacing arthroplasty, excessive valgus positioning or surgical technique can result in notching of the femoral neck. Although mechanical weakening and subsequent fracture of the femoral neck are well described, the potential damage to the retinacular vessels leading to an ischaemic event is relatively unknown. Using laser Doppler flowmetry, we measured the blood flow in 14 osteoarthritic femoral heads during routine total hip replacement surgery, before and after notching of the femoral neck. In ten hips there was a reduction in blood flow of more than 50% from the baseline value after simulated notching of the femoral neck. Our results suggest that femoral head vascularity in the osteoarthritic state is similar to the non-arthritic state, where damage to the extraosseous vessels can predispose to avascular necrosis. Surgeons who perform resurfacing arthroplasty of the hip should pay careful attention to these vessels by avoiding excessive dissection around the femoral neck and/or notching


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 44 - 47
1 Feb 1976
Haw C Gray D

The results of excision arthroplasty on forty hips in thirty-two patients have been studied by personal review. The mean follow-up was ten years and the results were graded in the Lazansky system. The outcome was fairly predictable, most patients achieving a fair to good result. The patients were satisfied with the operation in unilateral cases as a secondary operation, but it was generally unsatisfactory as a primary procedure or when performed bilaterally. Pain relief was satisfactory, and previously infected hips achieved sound wound and bone healing. Half could walk with no aid or one stick. No correlation could be found between the radiological appearances and the quality of the result


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 548 - 551
1 Aug 1965
Martin NS

1. After almost seventeen years the three metal prostheses remain in approximately the original position in which they were inserted. 2. All three patients are ambulatory and two of them pleased with the result. 3. The youngest patient, now fifty-six, has a solid ankylosis of the hip and leads an active life free of pain. 4. In view of the attritional changes which have been seen to occur as a result of the reaction of bone to metal, it is suggested that resection replacement operations should be reserved for the primary treatment of certain fractures in the elderly and in those patients who are expected to be mostly inactive for the rest of their life. As a rough guide, it is considered that the operation should not be carried out under the age of seventy


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1175 - 1182
1 Sep 2015
Bisseling P de Wit BWK Hol AM van Gorp MJ van Kampen A van Susante JLC

Patients from a randomised trial on resurfacing hip arthroplasty (RHA) (n = 36, 19 males; median age 57 years, 24 to 65) comparing a conventional 28 mm metal-on-metal total hip arthroplasty (MoM THA) (n = 28, 17 males; median age 59 years, 37 to 65) and a matched control group of asymptomatic patients with a 32 mm ceramic-on-polyethylene (CoP) THA (n = 33, 18 males; median age 63 years, 38 to 71) were cross-sectionally screened with metal artefact reducing sequence-MRI (MARS-MRI) for pseudotumour formation at a median of 55 months (23 to 72) post-operatively. MRIs were scored by consensus according to three different classification systems for pseudotumour formation. . Clinical scores were available for all patients and metal ion levels for MoM bearing patients. . Periprosthetic lesions with a median volume of 16 mL (1.5 to 35.9) were diagnosed in six patients in the RHA group (17%), one in the MoM THA group (4%) and six in the CoP group (18%). The classification systems revealed no clear differences between the groups. Solid lesions (n = 3) were exclusively encountered in the RHA group. Two patients in the RHA group and one in the MoM THA group underwent a revision for pseudotumour formation. There was no statistically significant relationship between clinical scoring, metal ion levels and periprosthetic lesions in any of the groups. . Periprosthetic fluid collections are seen on MARS-MRI after conventional CoP THA and RHA and may reflect a soft-tissue collection or effusion. . Currently available MRI classification systems seem to score these collections as pseudotumours, causing an-overestimatation of the incidence of pseudotumours. . Cite this article: Bone Joint J 2015;97-B:1175–82


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1352 - 1355
1 Oct 2007
Jeys LM Luscombe JS Grimer RJ Abudu A Tillman RM Carter SR

Between 1966 and 2001, 1254 patients underwent excision of a bone tumour with endoprosthetic replacement. All patients who had radiotherapy were identified. Their clinical details were retrieved from their records. A total of 63 patients (5%) had received adjunctive radiotherapy, 29 pre-operatively and 34 post-operatively. The mean post-operative Musculoskeletal Tumor Society scores of irradiated patients were significantly lower (log-rank test, p = 0.009). The infection rate in the group who had not been irradiated was 9.8% (117 of 1191), compared with 20.7% (6 of 29) in those who had pre-operative radiotherapy and 35.3% (12 of 34) in those who radiotherapy post-operatively. The infection-free survival rate at ten years was 85.5% for patients without radiotherapy, 74.1% for those who had pre-operative radiotherapy and 44.8% for those who had post-operative radiotherapy (log-rank test, p < 0.001). The ten-year limb salvage rate was 89% for those who did not have radiotherapy and 76% for those who did (log-rank test, p = 0.02). Radiotherapy increased the risk of revision (log-rank test, p = 0.015). A total of ten amputations were necessary to control infection, of which nine were successful. Radiotherapy may be necessary for the treatment of a bone sarcoma but increases the risk of deep infection for which amputation may be the only solution


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 233 - 238
1 Mar 2000
Cheng SL Morrey BF

Between 1986 and 1994, 13 patients with mobile painful arthritic elbows were treated by distraction interposition arthroplasty using fascia lata. The mean period of follow-up was 63 months. An elbow distractor/fixator was applied for three to four weeks to separate the articular surfaces and to protect the fascial graft. Nine of the 13 patients (69%) had satisfactory relief from pain; eight (62%) had an excellent or good result by the objective criteria of the Mayo Elbow Performance score. Four have required revision to total elbow arthroplasty at a mean of 30 months with good results to date. Instability of the elbow, both before and after surgery, was found to be associated with unsatisfactory results. The rate of success when the procedure was performed for inflammatory arthritis was similar to that for post-traumatic arthritis, about 67%. Eight complications occurred in six patients, all in the group with post-traumatic arthritis. Two of these required further surgical procedures such as transposition of the ulnar nerve or repair of hernia of the fascia lata. Although less reliable than prosthetic replacement, distraction interposition arthroplasty is a useful option in the treatment of young, high-demand patients with arthritis of the elbow. It is rarely indicated in the presence of generalised inflammatory arthritis, but may be of value in those patients in whom the disease is limited primarily to the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 1 | Pages 76 - 87
1 Feb 1969
Platt G Pepler C

1. Stainless steel mould arthroplasty of the knee is described and a ten-year follow-up study of sixty-two operations is reported. Fifty-four were for rheumatoid arthritis and eight for osteoarthritis. 2. Forty-nine of the sixty-two joints retained mobility, six had become ankylosed and five were later arthrodesed ; two limbs were amputated. The forty-nine mobile knees included twenty-seven which were painless at all times, and fourteen in which only an occasional twinge was felt. 3. The range of movement was increased in twenty-two joints as compared with the state before operation, diminished in twelve and unaltered in five. In ten knees measurements before operation were not available. 4. Flexion deformity, swelling, stability and function were improved in a significant number of joints. 5. Patients suffering from active rheumatoid arthritis often found that the joint operated upon no longer took part in generalised flares of the disease


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 729 - 734
1 Jun 2012
Kakkos SK Warwick D Nicolaides AN Stansby GP Tsolakis IA

We performed a systematic review and meta-analysis to compare the efficacy of intermittent mechanical compression combined with pharmacological thromboprophylaxis, against either mechanical compression or pharmacological prophylaxis in preventing deep-vein thrombosis (DVT) and pulmonary embolism in patients undergoing hip or knee replacement. A total of six randomised controlled trials, evaluating a total of 1399 patients, were identified. In knee arthroplasty, the rate of DVT was reduced from 18.7% with anticoagulation alone to 3.7% with combined modalities (risk ratio (RR) 0.27, p = 0.03; number needed to treat: seven). There was moderate, albeit non-significant, heterogeneity (I. 2. = 42%). In hip replacement, there was a non-significant reduction in DVT from 8.7% with mechanical compression alone to 7.2% with additional pharmacological prophylaxis (RR 0.84) and a significant reduction in DVT from 9.7% with anticoagulation alone to 0.9% with additional mechanical compression (RR 0.17, p < 0.001; number needed to treat: 12), with no heterogeneity (I. 2. = 0%). The included studies had insufficient power to demonstrate an effect on pulmonary embolism. We conclude that the addition of intermittent mechanical leg compression augments the efficacy of anticoagulation in preventing DVT in patients undergoing both knee and hip replacement. Further research on the role of combined modalities in thromboprophylaxis in joint replacement and in other high-risk situations, such as fracture of the hip, is warranted