header advert
Results 181 - 200 of 1898
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 579 - 583
1 May 2018
Xu S Chen JY Lo NN Chia SL Tay DKJ  Pang HN Hao Y Yeo SJ

Aims. This study investigated the influence of body mass index (BMI) on patients’ function and quality of life ten years after total knee arthroplasty (TKA). Patients and Methods. A total of 126 patients who underwent unilateral TKA in 2006 were prospectively included in this retrospective study. They were categorized into two groups based on BMI: < 30 kg/m. 2. (control) and ≥ 30 kg/m. 2. (obese). Functional outcome was assessed using the Knee Society Function Score (KSFS), Knee Society Knee Score (KSKS), and Oxford Knee Score (OKS). Quality of life was assessed using the Physical (PCS) and Mental Component Scores (MCS) of the 36-Item Short-Form Health Survey. Results. Patients in the obese group underwent TKA at a younger age (mean, 63.0 years, . sd. 8.0) compared with the control group (mean, 65.6 years, . sd. 7.6; p = 0.03). Preoperatively, both groups had comparable functional and quality-of-life scores. Ten years postoperatively, the control group had significantly higher OKS and MCS compared with the obese group (OKS, mean 18 (. sd. 5) vs mean 22 (. sd. 10), p = 0.03; MCS, mean 56 (. sd. 10) vs mean 50 (. sd. 11), p = 0.01). After applying multiple linear regression with the various outcomes scores as dependent variables and age, gender, and Charlson Comorbidity Index as independent variables, there was a clear association between obesity and poorer outcome in KSFS, OKS, and MCS at ten years postoperatively (p < 0.01 in both KSFS and OKS, and p = 0.03 in MCS). Both groups had a high satisfaction rate (97.8% in the control groupvs 87.9% in the obese group, p = 0.11) and fulfillment of expectations at ten years (98.9% in the control group vs 100% in the obese group, p = 0.32). Conclusion. Although both obese and non-obese patients have significant improvements in function and quality of life postoperatively, obese patients tend to have smaller improvements in the OKS and MCS ten years postoperatively. It is important to counsel patients on the importance of weight management to achieve a more sustained outcome after TKA. Cite this article: Bone Joint J 2018;100-B:579–83


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1640 - 1644
1 Dec 2013
Agarwal S Azam A Morgan-Jones R

Bone loss in the proximal tibia and distal femur is frequently encountered in revision knee replacement surgery. The various options for dealing with this depend on the extent of any bone loss. We present our results with the use of cementless metaphyseal metal sleeves in 103 patients (104 knees) with a mean follow-up of 43 months (30 to 65). At final follow-up, sleeves in 102 knees had good osseointegration. Two tibial sleeves were revised for loosening, possibly due to infection.

The average pre-operative Oxford Knee Score was 23 (11 to 36) and this improved to 32 (15 to 46) post-operatively. These early results encourage us to continue with the technique and monitor the outcomes in the long term.

Cite this article: Bone Joint J 2013;95-B:1640–4.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 122 - 126
1 Jan 2014
Bloch BV Patel V Best AJ

Since the introduction of the National Institute for Health and Care Excellence (NICE) guidelines on thromboprophylaxis and the use of extended thromboprophylaxis with new oral agents, there have been reports of complications arising as a result of their use. We have looked at the incidence of wound complications after the introduction of dabigatran for thromboprophylaxis in our unit.

We investigated the rate of venous thromboembolism and wound leakage in 1728 patients undergoing primary joint replacement, both before and after the introduction of dabigatran, and following its subsequent withdrawal from our unit.

We found that the use of dabigatran led to a significant increase in post-operative wound leakage (20% with dabigatran, 5% with a multimodal regimen; p < 0.001), which also resulted in an increased duration of hospital stay. The rate of thromboembolism in patients receiving dabigatran was higher (1.3%) than in those receiving the multimodal thromboprophylaxis regimen, including low molecular weight heparin as an inpatient and the extended use of aspirin (0.3%, p = 0.047). We have ceased the use of dabigatran for thromboprophylaxis in these patients.

Cite this article: Bone Joint J 2014;96-B:122–6.


Bone & Joint 360
Vol. 10, Issue 4 | Pages 5 - 11
1 Aug 2021
Kurien T Scammell BE


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 752 - 758
1 Jun 2014
Scott CEH Murray RC MacDonald DJ Biant LC

We explored the outcome of staged bilateral total knee replacement (TKR) for symmetrical degenerative joint disease and deformity in terms of patient expectations, functional outcome and satisfaction. From 2009 to 2011, 70 consecutive patients (41 female) with a mean age of 71.7 years (43 to 89) underwent 140 staged bilateral TKRs at our institution, with a mean time between operations of 7.8 months (2 to 25). Patients were assessed pre-operatively and at six and 12 months post-operatively using the Short Form-12, Oxford knee score (OKS), expectation questionnaire and satisfaction score. The pre-operative OKS was significantly worse before the first TKR (TKR1), but displayed significantly greater improvement than that observed after the second TKR (TKR2). Expectation level increased from TKR1 to TKR2 in 17% and decreased in 20%. Expectations of pain relief and stair-climbing were less before TKR2; in contrast, expectations of sporting and social activities were greater. Decreased expectations of TKR2 were significantly associated with younger age and high expectations before TKR1. Patient satisfaction was high for both TKR1 (93%) and TKR2 (87%) but did not correlate significantly within individuals. We concluded that satisfaction with one TKR does not necessarily translate to satisfaction following the second. . Cite this article: Bone Joint J 2014;96-B:752–8


Objectives. Tranexamic acid (TXA) is an antifibrinolytic agent used as a blood-sparing technique in total knee arthroplasty (TKA), and is routinely administered by intravenous (IV) or intra-articular (IA) injection. Recently, a novel method of TXA administration, the combined IV and IA application of TXA, has been applied in TKA. However, the scientific evidence of combined administration of TXA in TKA is still meagre. This meta-analysis aimed to investigate the efficacy and safety of combined IV and IA TXA in patients undergoing TKA. Materials and Methods. A systematic search was carried out in PubMed, the Cochrane Clinical Trial Register (Issue12 2015), Embase, Web of Science and the Chinese Biomedical Database. Only randomised controlled trials (RCT) evaluating the efficacy and safety of combined use TXA in TKA were identified. Two authors independently identified the eligible studies, extracted data and assessed the methodological quality of included studies. Meta-analysis was conducted using Review Manager 5.3 software. Results. A total of ten RCTs (1143 patients) were included in this study. All the included studies were randomised and the quality of included studies still needed improvement. The results indicated that, compared with either placebo or the single-dose TXA (IV or IA) group, the combination of IV and IA TXA group had significantly less total blood loss, hidden blood loss, total drain output, a lower transfusion rate and a lower drop in haemoglobin level. There were no statistically significant differences in complications such as wound infection and deep vein thrombosis between the combination group and the placebo or single-dose TXA group. Conclusions. Compared with placebo or the single-dose TXA, the combined use of IV and IA TXA provided significantly better results with respect to all outcomes related to post-operative blood loss without increasing the risk of thromboembolic complications in TKA. Cite this article: Z. F. Yuan, H. Yin, W. P. Ma, D. L. Xing. The combined effect of administration of intravenous and topical tranexamic acid on blood loss and transfusion rate in total knee arthroplasty: combined tranexamic acid for TKA. Bone Joint Res 2016;5:353–361. DOI: 10.1302/2046-3758.58.BJR-2016-0001.R2


Bone & Joint Research
Vol. 11, Issue 4 | Pages 226 - 228
20 Apr 2022
Hiranaka T Suda Y Saitoh A Koide M Tanaka A Arimoto A Fujishiro T Okamoto K


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1321 - 1329
1 Oct 2012
Sarmah SS Patel S Hossain FS Haddad FS

Radiological assessment of total and unicompartmental knee replacement remains an essential part of routine care and follow-up. Appreciation of the various measurements that can be identified radiologically is important. It is likely that routine plain radiographs will continue to be used, although there has been a trend towards using newer technologies such as CT, especially in a failing knee, where it provides more detailed information, albeit with a higher radiation exposure.

The purpose of this paper is to outline the radiological parameters used to evaluate knee replacements, describe how these are measured or classified, and review the current literature to determine their efficacy where possible.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 144 - 147
1 Nov 2013
Jones RE Russell RD Huo MH

Satisfactory primary wound healing following total joint replacement is essential. Wound healing problems can have devastating consequences for patients. Assessment of their healing capacity is useful in predicting complications. Local factors that influence wound healing include multiple previous incisions, extensive scarring, lymphoedema, and poor vascular perfusion. Systemic factors include diabetes mellitus, inflammatory arthropathy, renal or liver disease, immune compromise, corticosteroid therapy, smoking, and poor nutrition. Modifications in the surgical technique are necessary in selected cases to minimise potential wound complications. Prompt and systematic intervention is necessary to address any wound healing problems to reduce the risks of infection and other potential complications.

Cite this article: Bone Joint J 2013;95-B, Supple A:144–7.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims. Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Methods. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m. 2. (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. Results. At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001). Conclusion. Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025–1032


Bone & Joint Research
Vol. 8, Issue 5 | Pages 207 - 215
1 May 2019
Key S Scott G Stammers JG Freeman MAR Pinskerova V Field RE Skinner J Banks SA

Objectives. The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities. Methods. Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed. Results. Overall, 1717 joint poses were analyzed. At a 1.0 mm detection threshold, 37 instances of surface separation were observed in the lateral compartment and four medially (p < 0.001). Separation was activity-dependent, both laterally and medially (p < 0.001), occurring more commonly during static deep flexion in the lateral compartment, and during static rotation in the medial compartment. Lateral separation occurred more frequently than medial during kneeling (7/14 lateral vs 1/14 medial; p = 0.031) and stepping (20/1022 lateral vs 0/1022 medial; p < 0.001). Separation varied significantly between individuals during dynamic activities. Conclusion. No consistent association between closest distances of the articular surfaces and knee position was found during any activity. Lift-off was infrequent and depended on the activity performed and the individual knee. Lateral separation was consistent with the design rationale. Medial lift-off was rare and mostly in non-weight-bearing activities. Cite this article: S. Key, G. Scott, J. G. Stammers, M. A. R. Freeman†, V. Pinskerova, R. E. Field, J. Skinner, S. A. Banks. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019;8:207–215. DOI: 10.1302/2046-3758.85.BJR-2018-0237.R1


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1490 - 1496
1 Nov 2013
Ong P Pua Y

Early and accurate prediction of hospital length-of-stay (LOS) in patients undergoing knee replacement is important for economic and operational reasons. Few studies have systematically developed a multivariable model to predict LOS. We performed a retrospective cohort study of 1609 patients aged ≥ 50 years who underwent elective, primary total or unicompartmental knee replacements. Pre-operative candidate predictors included patient demographics, knee function, self-reported measures, surgical factors and discharge plans. In order to develop the model, multivariable regression with bootstrap internal validation was used. The median LOS for the sample was four days (interquartile range 4 to 5). Statistically significant predictors of longer stay included older age, greater number of comorbidities, less knee flexion range of movement, frequent feelings of being down and depressed, greater walking aid support required, total (versus unicompartmental) knee replacement, bilateral surgery, low-volume surgeon, absence of carer at home, and expectation to receive step-down care. For ease of use, these ten variables were used to construct a nomogram-based prediction model which showed adequate predictive accuracy (optimism-corrected R2 = 0.32) and calibration. If externally validated, a prediction model using easily and routinely obtained pre-operative measures may be used to predict absolute LOS in patients following knee replacement and help to better manage these patients.

Cite this article: Bone Joint J 2013;95-B:1490–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 200 - 204
1 Feb 2012
Clement ND Jenkins PJ Brenkel IJ Walmsley P

We report the general mortality rate after total knee replacement and identify independent predictors of survival. We studied 2428 patients: there were 1127 men (46%) and 1301 (54%) women with a mean age of 69.3 years (28 to 94). Patients were allocated a predicted life expectancy based on their age and gender.

There were 223 deaths during the study period. This represented an overall survivorship of 99% (95% confidence interval (CI) 98 to 99) at one year, 90% (95% CI 89 to 92) at five years, and 84% (95% CI 82 to 86) at ten years. There was no difference in survival by gender. A greater mortality rate was associated with increasing age (p < 0.001), American Society of Anesthesiologists (ASA) grade (p < 0.001), smoking (p < 0.001), body mass index (BMI) <  20 kg/m2 (p < 0.001) and rheumatoid arthritis (p < 0.001). Multivariate modelling confirmed the independent effect of age, ASA grade, BMI, and rheumatoid disease on mortality. Based on the predicted average mortality, 114 patients were predicted to have died, whereas 217 actually died. This resulted in an overall excess standardised mortality ratio of 1.90. Patient mortality after TKR is predicted by their demographics: these could be used to assign an individual mortality risk after surgery.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 105 - 111
1 Nov 2014
Vince KG

There are many reasons why a total knee replacement (TKR) may fail and qualify for revision. Successful revision surgery depends as much on accurate assessment of the problem TKR as it does on revision implant design and surgical technique. Specific modes of failure require specific surgical solutions. Causes of failure are often presented as a list or catalogue, without a system or process for making a decision. In addition, strict definitions and consensus on modes of failure are lacking in published series and registry data. How we approach the problem TKR is an essential but neglected aspect of understanding knee replacement surgery. It must be carried out systematically, comprehensively and efficiently. Eight modes of failure are described: 1) sepsis; 2) extensor discontinuity; 3) stiffness; 4) tibial- femoral instability; 5) patellar tracking; 6) aseptic loosening and osteolysis; 7) periprosthetic fracture and 8) component breakage. A ninth ‘category’, unexplained pain is an indication for further investigation but not surgery. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):105–11


Bone & Joint Research
Vol. 5, Issue 3 | Pages 80 - 86
1 Mar 2016
Scott G Imam MA Eifert A Freeman MAR Pinskerova V Field RE Skinner J Banks SA

Objectives. Throughout the 20th Century, it has been postulated that the knee moves on the basis of a four-bar link mechanism composed of the cruciate ligaments, the femur and the tibia. As a consequence, the femur has been thought to roll back with flexion, and total knee arthroplasty (TKA) prostheses have been designed on this basis. Recent work, however, has proposed that at a position of between 0° and 120° the medial femoral condyle does not move anteroposteriorly whereas the lateral femoral condyle tends, but is not obliged, to roll back – a combination of movements which equates to tibial internal/ femoral external rotation with flexion. The aim of this paper was to assess if the articular geometry of the GMK Sphere TKA could recreate the natural knee movements in situ/in vivo. Methods. The pattern of knee movement was studied in 15 patients (six male: nine female; one male with bilateral TKAs) with 16 GMK Sphere implants, at a mean age of 66 years (53 to 76) with a mean BMI of 30 kg/m. 2. (20 to 35). The motions of all 16 knees were observed using pulsed fluoroscopy during a number of weight-bearing and non-weight-bearing static and dynamic activities. Results. During maximally flexed kneeling and lunging activities, the mean tibial internal rotation was 8° (standard deviation (. sd. ) 6). At a mean 112° flexion (. sd. 16) during lunging, the medial and lateral condyles were a mean of 2 mm (. sd. 3) and 8 mm (. sd. 4) posterior to a transverse line passing through the centre of the medial tibial concavity. With a mean flexion of 117° (. sd. 14) during kneeling, the medial and lateral condyles were a mean of 1 mm (. sd. 4) anterior and 6 mm (. sd. 4) posterior to the same line. During dynamic stair and pivoting activities, there was a mean anteroposterior translation of 0 mm to 2 mm of the medial femoral condyle. Backward lateral condylar translation occurred and was linearly related to tibial rotation. Conclusion. The GMK Sphere TKA in our study group shows movements similar in pattern, although reduced in magnitude, to those in recent reports relating to normal knees during several activities. Specifically, little or no translation of the medial femoral condyle was observed during flexion, but there was posterior roll-back of the lateral femoral condyle, equating to tibiofemoral rotation. We conclude that the GMK Sphere is anteroposteriorly stable medially and permits rotation about the medial compartment. Cite this article: Professor G. Scott. Can a total knee arthroplasty be both rotationally unconstrained and anteroposteriorly stabilised?: A pulsed fluoroscopic investigation. Bone Joint Res 2016;5:80–86. DOI: 10.1302/2046-3758.53.2000621


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 497 - 503
1 Apr 2012
Bercovy M Beldame J Lefebvre B Duron A

This prospective study compares the outcome of 157 hydroxyapatite (HA)-coated tibial components with 164 cemented components in the ROCC Rotating Platform total knee replacement in 291 patients. The mean follow-up was 7.6 years (5.2 to 11). There were two revisions for loosening: one for an HA-coated and one for a cemented tibial component. Radiological evaluation demonstrated no radiolucent lines with the HA-coated femoral components. A total of three HA-coated tibial components exhibited radiolucent lines at three months post-operatively and these disappeared after three further months of protected weight-bearing. With HA-coated components the operating time was shorter (p <  0.006) and the radiological assessment of the tibial interface was more stable (p < 0.01). Using revision for aseptic loosening of the tibial component as the end point, the survival rates at nine years was identical for both groups at 99.1%.

Our results suggest that HA-coated components perform at least as well as the same design with cemented components and compare favourably with those of series describing cemented or porous-coated knee replacements, suggesting that fixation of both components with hydroxyapatite is a reliable option in primary total knee replacement.


Bone & Joint Research
Vol. 1, Issue 12 | Pages 315 - 323
1 Dec 2012
Molt M Ljung P Toksvig-Larsen S

Objectives

The objective of this study was to compare the early migration characteristics and functional outcome of the Triathlon cemented knee prosthesis with its predecessor, the Duracon cemented knee prosthesis (both Stryker).

Methods

A total 60 patients were prospectively randomised and tibial component migration was measured by radiostereometric analysis (RSA) at three months, one year and two years; clinical outcome was measured by the American Knee Society score and the Knee Osteoarthritis and Injury Outcome Score.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 133 - 134
1 Nov 2013
Parvizi J Diaz-Ledezma C

Total knee replacement (TKR) is an operation that can be performed with or without the use of a tourniquet. Meta-analyses of the available Level-1 studies have demonstrated that the use of a tourniquet leads to a significant reduction in blood loss. The opponents for use of a tourniquet cite development of complications such as skin bruising, neurovascular injury, and metabolic disturbance as drawbacks. Although there may certainly be reason for concern in arteriopathic patients, there is little evidence that routine use of a tourniquet during TKR results in any of the above complications. The use of a tourniquet, on the other hand, provides a bloodless field that allows the surgeon to perform the procedure with expediency and optimal visualisation. Blood conservation has gained great importance in recent years due to increased understanding of the problems associated with blood transfusion, such as increased surgical site infection (due to immunomodulation effect), increased length of hospital stay and increased cost. Based on the authors’ understanding of the available evidence, the routine use of a tourniquet during TKR is justified as good surgical practice. . Cite this article: Bone Joint J 2013;95-B, Supple A:133–4


Bone & Joint 360
Vol. 5, Issue 4 | Pages 4 - 15
1 Aug 2016
Sehat K

Anatomical total knee arthroplasty alignment versus conventional mechanical alignment; or a combination?


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 647 - 652
1 May 2017
Abdel MP Ledford CK Kobic A Taunton MJ Hanssen AD

Aims. The number of revision total knee arthroplasties (TKA) that are performed is expected to increase. However, previous reports of the causes of failure after TKA are limited in that they report the causes at specific institutions, which are often dependent on referral patterns. Our aim was to report the most common indications for re-operations and revisions in a large series of posterior-stabilised TKAs undertaken at a single institution, excluding referrals from elsewhere, which may bias the causes of failure. Patients and Methods. A total of 5098 TKAs which were undertaken between 2000 and 2012 were included in the study. Re-operations, revisions with modular component exchange, and revisions with non-modular component replacement or removal were identified from the medical records. The mean follow-up was five years (two to 12). Results. The Kaplan-Meier ten-year survival without a re-operation, modular component revision and non-modular component revision was 95.7%, 99.3% and 95.3%, respectively. The most common indications for a re-operation were: post-operative stiffness (58%), delayed wound healing (21%), and patellar clunk (11%). The indications for isolated modular component revision were acute periprosthetic joint infection (PJI) (64%) and instability (36%). The most common indications for non-modular component revision were chronic PJI (52%), aseptic loosening (17%), periprosthetic fracture (10%), and instability (10%). Conclusion. Post-operative stiffness remains the most common indication for re-operation after TKA. Infection is the most common indication for modular and non-modular component revision. Aseptic loosening was not an uncommon cause of failure, however, it was much less common than in national registry and non-registry data. Focusing on posterior-stabilised TKAs initially performed at our institution allowed for an accurate assessment of the causes of failure in a contemporary specialty practice. Cite this article: Bone Joint J 2017;99-B:647–52