Advertisement for orthosearch.org.uk
Results 181 - 200 of 381
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 87 - 92
1 Nov 2014
Kwong LM Nielsen ESN Ruiz DR Hsu AH Dines MD Mellano CM

A retrospective review was performed of patients undergoing primary cementless total knee replacement (TKR) using porous tantalum performed by a group of surgical trainees. Clinical and radiological follow-up involved 79 females and 26 males encompassing 115 knees. The mean age was 66.9 years (36 to 85). Mean follow-up was 7 years (2 to 11). Tibial and patellar components were porous tantalum monoblock implants, and femoral components were posterior stabilised (PS) in design with cobalt–chromium fibre mesh. Radiological assessments were made for implant positioning, alignment, radiolucencies, lysis, and loosening. There was 95.7% survival of implants. There was no radiological evidence of loosening and no osteolysis found. No revisions were performed for aseptic loosening. Average tibial component alignment was 1.4° of varus (4°of valgus to 9° varus), and 6.2° (3° anterior to 15° posterior) of posterior slope. Mean femoral component alignment was 6.6° (1° to 11°) of valgus. Mean tibiofemoral alignment was 5.6° of valgus (7° varus to 16° valgus). Patellar tilt was a mean of 2.4° lateral (5° medial to 28° lateral). Patient satisfaction with improvement in pain was 91%. Cementless TKR incorporating porous tantalum yielded good clinical and radiological outcomes at a mean of follow-up of seven-years.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):87–92.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 101 - 104
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

Previous studies of failure mechanisms leading to revision total knee replacement (TKR) performed between 1986 and 2000 determined that many failed early, with a disproportionate amount accounted for by infection and implant-associated factors including wear, loosening and instability. Since then, efforts have been made to improve implant performance and instruct surgeons in best practice. Recently our centre participated in a multi-centre evaluation of 844 revision TKRs from 2010 to 2011. The purpose was to report a detailed analysis of failure mechanisms over time and to see if failure modes have changed over the past 10 to 15 years. Aseptic loosening was the predominant mechanism of failure (31.2%), followed by instability (18.7%), infection (16.2%), polyethylene wear (10.0%), arthrofibrosis (6.9%) and malalignment (6.6%). The mean time to failure was 5.9 years (ten days to 31 years), 35.3% of all revisions occurred at less than two years, and 60.2% in the first five years. With improvements in implant and polyethylene manufacture, polyethylene wear is no longer a leading cause of failure. Early mechanisms of failure are primarily technical errors. In addition to improving implant longevity, industry and surgeons must work together to decrease these technical errors. All reports on failure of TKR contain patients with unexplained pain who not infrequently have unmet expectations. Surgeons must work to achieve realistic patient expectations pre-operatively, and therefore, improve patient satisfaction post-operatively.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):101–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 879 - 886
1 Jul 2007
Howie DW Wimhurst JA McGee MA Carbone TA Badaruddin BS

We investigated 219 revisions of total hip replacement (THR) in 211 patients using a collarless double-taper cemented femoral component. The mean age of the patients was 72 years (30 to 90). The 137 long and 82 standard length stems were analysed separately. The mean follow-up was six years (2 to 18), and no patient was lost to follow-up.

Survival of the long stems to re-revision for aseptic loosening at nine years was 98% (95% confidence interval (CI) 94 to 100), and for the standard stems was 93% (95% CI 85 to 100). At five years, one long stem was definitely loose radiologically and one standard stem was probably loose. Pre-operative femoral bone deficiency did not influence the results for the long stems, and corrective femoral osteotomy was avoided, as were significant subsidence, major stress shielding and persistent thigh pain.

Because of these reliable results, cemented long collarless double-taper femoral components are recommended for routine revision THR in older patients.


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 292 - 299
1 Mar 2015
Karthik K Colegate-Stone T Dasgupta P Tavakkolizadeh A Sinha J

The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics.

Cite this article: Bone Joint J 2015; 97-B:292–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 760 - 768
1 Jun 2011
ten Broeke RHM Alves A Baumann A Arts JJC Geesink RGT

Four uncemented Symax hip stems were extracted at three weeks and nine, 13 and 32 months, respectively, for reasons other than loosening. The reasons for implant removal were infection in two cases, recurrent dislocation in one and acetabular fracture in one. They were analysed to assess the effect and behaviour of an electrochemically deposited, completely resorbable biomimetic BONIT-hydroxyapatite (HA) coating (proximal part) and a DOTIZE surface treatment (distal part) using qualitative histology, quantitative histomorphometry and scanning electron microscopy (SEM). Early and direct bone-implant bonding with signs of active remodelling of bone and the HA coating were demonstrated by histology and SEM. No loose BONIT-HA particles or delamination of the coating were observed, and there was no inflammation or fibrous interposition at the interface.

Histomorphometry showed bone-implant contact varying between 26.5% at three weeks and 83.5% at 13 months at the HA-coated implant surface. The bone density in the area of investigation was between 24.6% at three weeks and 41.1% at 32 months. The DOTIZE surface treatment of the distal part of the stem completely prevented tissue and bone apposition in all cases, thereby optimising proximal stress transfer.

The overall features of this implant, in terms of geometry and surface texture, suggest a mechanically stable design with a highly active biomimetic coating, resulting in rapid and extensive osseo-integration, exclusively in the metaphyseal part of the stem. Early remodelling of the HA coating does not seem to have a detrimental effect on short-term bone-implant coupling. There were no adverse effects identified from either the BONIT-HA coating or the DOTIZE surface treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1561 - 1566
1 Dec 2007
Nowicki P Chaudhary H

Avascular necrosis of the femoral head creates considerable morbidity in successful renal transplant recipients who are generally young and expect active lifestyles. Total hip replacement is considered the treatment of choice in these patients, but surgeons may be wary because of a supposed increase in the risk of infection and other complications.

A review of the literature reveals that cemented hip arthroplasty provides good to excellent functional outcomes for renal transplant patients. Most authors have found that the risk of infection is not increased despite chronic immunosuppression, but the rates of general complications are and should be anticipated and treated. There is a high rate of early failure in these patients because of their young age and diffuse osteopenia as a result of secondary hyperparathyroidism related to the underlying renal disease and chronic steroid use. Recent studies have found that despite decreased bone stock in these patients, porous-coated prostheses are not contraindicated.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1611 - 1617
1 Dec 2012
Jameson SS Baker PN Mason J Gregg PJ Brewster N Deehan DJ Reed MR

Despite excellent results, the use of cemented total hip replacement (THR) is declining. This retrospective cohort study records survival time to revision following primary cemented THR using the most common combination of components that accounted for almost a quarter of all cemented THRs, exploring risk factors independently associated with failure. All patients with osteoarthritis who had an Exeter V40/Contemporary THR (Stryker) implanted before 31 December 2010 and recorded in the National Joint Registry for England and Wales were included in the analysis. Cox’s proportional hazard models were used to analyse the extent to which risk of revision was related to patient, surgeon and implant covariates, with a significance threshold of p < 0.01. A total of 34 721 THRs were included in the study. The overall seven-year rate of revision for any reason was 1.70% (99% confidence interval (CI) 1.28 to 2.12). In the final adjusted model the risk of revision was significantly higher in THRs with the Contemporary hooded component (hazard ratio (HR) 1.88, p < 0.001) than with the flanged version, and in smaller head sizes (< 28 mm) compared with 28 mm diameter heads (HR 1.50, p = 0.005). The seven-year revision rate was 1.16% (99% CI 0.69 to 1.63) with a 28 mm diameter head and flanged component. The overall risk of revision was independent of age, gender, American Society of Anesthesiologists grade, body mass index, surgeon volume, surgical approach, brand of cement/presence of antibiotic, femoral head material (stainless steel/alumina) and stem taper size/offset. However, the risk of revision for dislocation was significantly higher with a ‘plus’ offset head (HR 2.05, p = 0.003) and a hooded acetabular component (HR 2.34, p < 0.001).

In summary, we found that there were significant differences in failure between different designs of acetabular component and sizes of femoral head after adjustment for a range of covariates.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 23 - 25
1 Aug 2014

The August 2014 Spine Roundup360 looks at: rhBMP complicates cervical spine surgery; posterior longitudinal ligament revisited; thoracolumbar posterior instrumentation without fusion in burst fractures; risk modelling for VTE events in spinal surgery; the consequences of dural tears in microdiscectomy; trends in revision spinal surgery; radiofrequency denervation likely effective in facet joint pain and hooks optimally biomechanically transition posterior instrumentation.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 105 - 111
1 Nov 2014
Vince KG

There are many reasons why a total knee replacement (TKR) may fail and qualify for revision. Successful revision surgery depends as much on accurate assessment of the problem TKR as it does on revision implant design and surgical technique. Specific modes of failure require specific surgical solutions. Causes of failure are often presented as a list or catalogue, without a system or process for making a decision. In addition, strict definitions and consensus on modes of failure are lacking in published series and registry data. How we approach the problem TKR is an essential but neglected aspect of understanding knee replacement surgery. It must be carried out systematically, comprehensively and efficiently. Eight modes of failure are described: 1) sepsis; 2) extensor discontinuity; 3) stiffness; 4) tibial- femoral instability; 5) patellar tracking; 6) aseptic loosening and osteolysis; 7) periprosthetic fracture and 8) component breakage. A ninth ‘category’, unexplained pain is an indication for further investigation but not surgery.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):105–11.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 608 - 615
1 May 2011
Bolland BJRF Culliford DJ Langton DJ Millington JPS Arden NK Latham JM

This study reports the mid-term results of a large-bearing hybrid metal-on-metal total hip replacement in 199 hips (185 patients) with a mean follow-up of 62 months (32 to 83).

Two patients died of unrelated causes and 13 were lost to follow-up. In all, 17 hips (8.5%) have undergone revision, and a further 14 are awaiting surgery. All revisions were symptomatic. Of the revision cases, 14 hips showed evidence of adverse reactions to metal debris. The patients revised or awaiting revision had significantly higher whole blood cobalt ion levels (p = 0.001), but no significant difference in acetabular component size or position compared with the unrevised patients. Wear analysis (n = 5) showed increased wear at the trunnion-head interface, normal levels of wear at the articulating surfaces and evidence of corrosion on the surface of the stem.

The cumulative survival rate, with revision for any reason, was 92.4% (95% confidence interval 87.4 to 95.4) at five years. Including those awaiting surgery, the revision rate would be 15.1% with a cumulative survival at five years of 89.6% (95% confidence interval 83.9 to 93.4).

This hybrid metal-on-metal total hip replacement series has shown an unacceptably high rate of failure, with evidence of high wear at the trunnion-head interface and passive corrosion of the stem surface. This raises concerns about the use of large heads on conventional 12/14 tapers.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1378 - 1384
1 Oct 2014
Weiser L Korecki MA Sellenschloh K Fensky F Püschel K Morlock MM Rueger JM Lehmann W

It is becoming increasingly common for a patient to have ipsilateral hip and knee replacements. The inter-prosthetic (IP) distance, the distance between the tips of hip and knee prostheses, has been thought to be associated with an increased risk of IP fracture. Small gap distances are generally assumed to act as stress risers, although there is no real biomechanical evidence to support this.

The purpose of this study was to evaluate the influence of IP distance, cortical thickness and bone mineral density on the likelihood of an IP femoral fracture.

A total of 18 human femur specimens were randomised into three groups by bone density and cortical thickness. For each group, a defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing the appropriate lengths of component. The maximum fracture strength was determined using a four-point bending test.

The fracture force of all three groups was similar (p = 0.498). There was a highly significant correlation between the cortical area and the fracture strength (r = 0.804, p <  0.001), whereas bone density showed no influence.

This study suggests that the IP distance has little influence on fracture strength in IP femoral fractures: the thickness of the cortex seems to be the decisive factor.

Cite this article: Bone Joint J 2014;96-B:1378–84.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 44 - 51
1 Jan 2009
Whittaker JP Warren RE Jones RS Gregson PA

When using a staged approach to eradicate chronic infection after total hip replacement, systemic delivery of antibiotics after the first stage is often employed for an extended period of typically six weeks together with the use of an in situ antibiotic-eluting polymethylmethacrylate interval spacer. We report our multi-surgeon experience of 43 consecutive patients (44 hips) who received systemic vancomycin for two weeks in combination with a vancomycin- and gentamicin-eluting spacer system in the course of a two-stage revision procedure for deep infection with a median follow-up of 49 months (25 to 83).

The antibiotic-eluting articulating spacers fractured in six hips (13.9%) and dislocated in five patients (11.6%). Successful elimination of the infecting organisms occurred in 38 (92.7%) of 41 hips with three patients developing superinfection with a new organism.

We conclude that prolonged systemic antibiotic therapy may not be essential in the two-stage treatment of a total hip replacement for Gram-positive infection, provided that a high concentration of antibiotics is delivered locally using an antibiotic-eluting system.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1349 - 1354
1 Oct 2014
Conway J Mansour J Kotze K Specht S Shabtai L

The treatment of infected nonunions is difficult. Antibiotic cement-coated (ACC) rods provide stability as well as delivering antibiotics. We conducted a review of 110 infected nonunions treated with ACC rods. Patients were divided into two groups: group A (67 patients) with an infected arthrodesis, and group B (43 patients) with an infected nonunion in a long bone. In group A, infected arthrodesis, the success rate after the first procedure was 38/67 (57%), 29/67 (43%) required further surgery for either control of infection or non-union. At last follow-up, five patients required amputation, representing a limb salvage rate of 62/67 (93%) overall. In all, 29/67 (43%) presented with a bone defect with a mean size of 6.78 cm (2 to 25). Of those with a bone defect, 13/29 (45%) required further surgery and had a mean size of defect of 7.2 cm (3.5 to 25). The cultures were negative in 17/67 (26%) and the most common organism cultured was methicillin-resistant staphylococcus aureus (MRSA) (23/67, (35%)). In group B, long bones nonunion, the success rate after the first procedure was 26/43 (60%), 17/43 (40%) required further surgery for either control of infection or nonunion. The limb salvage rate at last follow-up was 43/43 (100%). A total of 22/43 (51%) had bone defect with a mean size of 4.7 cm (1.5 to 11.5). Of those patients with a bone defect, 93% required further surgery with a mean size of defect of 5.4 cm (3 to 8.5). The cultures were negative in 10/43 (24%) and the most common organism cultured was MRSA, 15/43 (35%). ACC rods are an effective form of treatment for an infected nonunion, with an acceptable rate of complications.

Cite this article: Bone Joint J 2014; 96-B:1349–54


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 875 - 881
1 Jul 2012
Vanhegan IS Morgan-Jones R Barrett DS Haddad FS

This review summarises the opinions and conclusions reached from a symposium on infected total knee replacement (TKR) held at the British Association of Surgery of the Knee (BASK) annual meeting in 2011. The National Joint Registry for England and Wales reported 5082 revision TKRs in 2010, of which 1157 (23%) were caused by infection. The diagnosis of infection beyond the acute post-operative stage relies on the identification of the causative organism by aspiration and analysis of material obtained at arthroscopy. Ideal treatment then involves a two-stage surgical procedure with extensive debridement and washout, followed by antibiotics. An articulating or non-articulating drug-eluting cement spacer is used prior to implantation of the revision prosthesis, guided by the serum level of inflammatory markers. The use of a single-stage revision is gaining popularity and we would advocate its use in certain patients where the causative organism is known, no sinuses are present, the patient is not immunocompromised, and there is no radiological evidence of component loosening or osteitis.

It is our opinion that single-stage revision produces high-quality reproducible results and will soon achieve the same widespread acceptance as it does in infected hip arthroplasty.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1035 - 1040
1 Aug 2014
Meling T Nawab A Harboe K Fosse L

An atypical femoral fracture (AFF), with a transverse fracture radiologically through the lateral cortex is a rare but serious condition. In order to improve our ability to identify patients with this condition, we retrospectively surveyed all subtrochanteric, peri-implant and diaphyseal femoral fractures in patients aged ≥ 65 years who underwent surgical treatment at our hospital between 2004 and 2011.

We describe the incidence of atypical fractures and their characteristics, with observational data including a review of the hospital and general practitioner records. Clinical outcomes were evaluated using the Harris hip score (HHS) and the timed up-and-go (TUG) test.

Atypical fractures only occurred in women with an incidence of 9.8 per 100 000 person-years. The incidence in those who were treated with bisphosphonates was 79.0 per 100 000 person-years; eight of 17 fractures occurred around metal implants. There was a high incidence of delayed union and revision surgery. A total of nine patients (ten AFFs) were available for review at a mean follow-up of 36.5 months (10 to 104). The clinical outcome was poor with a mean HHS of 58.9 (95% CI 47.4 to 70.4) and a mean TUG test of 25.7 s (95% CI 12.7 to 38.8).

The delay in diagnosis and treatment of AFF may result from a lack of knowledge of this condition.

Cite this article: Bone Joint J 2014; 96-B:1035–40.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 75 - 81
1 Jan 2009
Cil A Veillette CJH Sanchez-Sotelo J Sperling JW Schleck C Cofield RH

Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3).

Pre-operatively, 34 patients (97%) had moderate or severe pain; at final follow-up, 29 (83%) had no or only mild pain (p < 0.0001). The mean active abduction improved from 88° to 107° (p < 0.01); and the mean external rotation from 37° to 46° (p = 0.27). Excellent or satisfactory results were achieved in 25 patients (71%) according to the modified Neer rating system. Humeral components were cemented in 29, with ingrowth implants used in nine cases. There were 19 of standard length and 17 were longer (two were custom replacements and are not included). Bone grafting was required for defects in 11 humeri. Only two glenoid components were left unrevised. Intra-operative complications included cement extrusion in eight cases, fracture of the shaft of the humerus is two and of the tuberosity in four. There were four re-operations, one for recurrent humeral loosening, with 89% survival free of re-operations at ten years.

Revision surgery for aseptic loosening of the humeral component provides reliable pain relief and modest improvement of movement, although there is a substantial risk of intra-operative complications. Revision to a total shoulder replacement gives better results than to a hemiarthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1084 - 1089
1 Aug 2008
Guo W Ji T Yang R Tang X Yang Y

In developing countries locally-made low-cost prostheses are mainly used in limb-salvage surgery to alleviate the economic burden.

We retrospectively collected data on 104 patients treated by limb-salvage surgery between July 1997 and July 2005. We used a locally-designed and fabricated stainless-steel endoprosthesis in each case. Oncological and functional outcomes were evaluated at a mean follow-up of 47 months (12 to 118).

A total of 73 patients (70.2%) were free from disease, nine (8.7%) were alive with disease, 19 (18.2%) had died from their disease and three (2.9%) from unrelated causes. According to the Musculoskeletal Tumor Society scoring system, the mean functional score was 76.3% (SD 17.8). The five-year survival for the implant was 70.5%. There were nine cases (8.7%) of infection, seven early and two late, seven (6.7%) of breakage of the prosthesis, three (2.9%) of aseptic loosening and two (1.9%) of failure of the polyethylene bushing. Multivariate analysis showed that a proximal tibial prosthesis and a resection length of 14 cm or more were significant negative prognostic factors.

Our survival rates and Musculoskeletal Tumor Society functional scores are similar to those reported in the literature. Although longer follow-up is needed to confirm our results, we believe that a low-cost custom-made endoprosthesis is a cost-effective and reliable reconstructive option for limb salvage in developing countries.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1192 - 1197
1 Sep 2014
Egol KA Marcano AI Lewis L Tejwani NC McLaurin TM Davidovitch RI

In March 2012, an algorithm for the treatment of intertrochanteric fractures of the hip was introduced in our academic department of Orthopaedic Surgery. It included the use of specified implants for particular patterns of fracture. In this cohort study, 102 consecutive patients presenting with an intertrochanteric fracture were followed prospectively (post-algorithm group). Another 117 consecutive patients who had been treated immediately prior to the implementation of the algorithm were identified retrospectively as a control group (pre-algorithm group). The total cost of the implants prior to implementation of the algorithm was $357 457 (mean: $3055 (1947 to 4133)); compared with $255 120 (mean: $2501 (1052 to 4133)) after its implementation. There was a trend toward fewer complications in patients who were treated using the algorithm (33% pre- versus 22.5% post-algorithm; p = 0.088). Application of the algorithm to the pre-algorithm group revealed a potential overall cost saving of $70 295.

The implementation of an evidence-based algorithm for the treatment of intertrochanteric fractures reduced costs while maintaining quality of care with a lower rate of complications and re-admissions.

Cite this article: Bone Joint J 2014;96-B:1192–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1299 - 1302
1 Oct 2006
Tillman R Kalra S Grimer R Carter S Abudu A

Peri- and sub-prosthetic fractures, or pathological fractures below an existing well-fixed femoral component, with or without an ipsilateral knee replacement, present a difficult surgical challenge.

We describe a simple solution, in which a custom-made prosthesis with a cylindrical design is cemented proximally to the stem of an existing, well-fixed femoral component. This effectively treats the fracture without sacrificing the good hip. We describe five patients with a mean age of 73 years (60 to 81) and a mean follow-up of 47 months (6 to 108).

The mean overlap of the prosthesis over the femoral component was 7.5 cm (5.5 to 10). There have been no mechanical failures, no new infections and no re-operations. We suggest that in highly selected cases, in which conventional fixation is not feasible, this technique offers a durable option and avoids the morbidity of a total femoral replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1632 - 1637
1 Dec 2011
Robinson CM Stone OD Murray IR

We identified 16 patients with a mean age of 56.5 years (31 to 86) from a large consecutive series of patients with proximal humeral fractures over a 15-year period, who had sustained a fracture with skin compromise after a blunt injury. The study group represented 0.2% of 7825 proximal humeral fractures treated during this period and all had a displaced Neer two-part fracture pattern. Two patterns of skin injury were identified: in ten patients there was skin penetration at the time of the original injury, and the other six patients initially had closed injuries. These six patients had fracture fragments penetrating the muscular envelope to lie subcutaneously producing either early skin tethering (two patients) or delayed skin penetration and sinus formation (four patients). The pattern of injury to the soft-tissue envelope and the fracture pattern were similar for all injuries. Treatment of these injuries was determined by the initial severity of the soft-tissue injury and the medical status of the patient. We currently favour open reduction and internal fixation of these fractures wherever possible, owing to the high rate of nonunion with non-operative management.