Advertisement for orthosearch.org.uk
Results 181 - 200 of 1985
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 548 - 551
1 Aug 1965
Martin NS

1. After almost seventeen years the three metal prostheses remain in approximately the original position in which they were inserted.

2. All three patients are ambulatory and two of them pleased with the result.

3. The youngest patient, now fifty-six, has a solid ankylosis of the hip and leads an active life free of pain.

4. In view of the attritional changes which have been seen to occur as a result of the reaction of bone to metal, it is suggested that resection replacement operations should be reserved for the primary treatment of certain fractures in the elderly and in those patients who are expected to be mostly inactive for the rest of their life. As a rough guide, it is considered that the operation should not be carried out under the age of seventy.


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 4 | Pages 802 - 809
1 Nov 1960
Claffey TJ



The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 852 - 852
1 Sep 1994
Fisher J


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 160 - 160
1 Jan 1993
Chevalier X Larget-Piet B Hernigou P Gherardi R


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 3 | Pages 442 - 444
1 Aug 1954
Palin HC Richmond DA


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 874 - 878
1 Jul 2007
Atilla B Ali H Aksoy MC Caglar O Tokgozoglu AM Alpaslan M

We have reviewed 54 patients who had undergone 61 total hip replacements using bulk femoral autografts to augment a congenitally dysplastic acetabulum. There were 52 women and two men with a mean age of 42.4 years (29 to 76) at the time of the index operation. A variety of different prostheses was used: 28 (45.9%) were cemented and 33 (54.1%) uncemented. The graft technique remained unchanged throughout the series.

Follow-up was at a mean of 8.3 years (3 to 20). The Hospital for Special Surgery hip score improved from a mean of 10.7 (4 to 18) pre-operatively to a mean of 35 (28 to 38) at follow-up.

The position of the acetabular component was anatomical in 37 hips (60.7%), displaced less than 1 cm in 20 (32.7%) and displaced more than 1 cm in four (6.6%). Its cover was between 50% and 75% in 34 hips (55.7%) and less than 50% in 25 (41%). In two cases (3.3%), it was more than 75%.

There was no graft resorption in 36 hips (59%), mild resorption in 21 (34%) and severe resorption in four (6%).

Six hips (9.8%) were revised for aseptic loosening. The overall rate of loosening and revision was 14.8%. Overall survival at 8.3 years was 93.4%.

The only significant factor which predicted failure was the implantation of the acetabular component more than 1 cm from the anatomical centre of rotation of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1281 - 1286
1 Oct 2009
Olsen M Davis ET Chiu M Gamble P Tumia N Boyle RA Schemitsch EH

The computed neck-shaft angle and the size of the femoral component were recorded in 100 consecutive hip resurfacings using imageless computer-navigation and compared with the angle measured before operation and with actual component implanted. The reliability of the registration was further analysed using ten cadaver femora. The mean absolute difference between the measured and navigated neck-shaft angle was 16.3° (0° to 52°). Navigation underestimated the measured neck-shaft angle in 38 patients and the correct implant size in 11. Registration of the cadaver femora tended to overestimate the correct implant size and provided a low level of repeatability in computing the neck-shaft angle.

Prudent pre-operative planning is advisable for use in conjunction with imageless navigation since misleading information may be registered intraoperatively, which could lead to inappropriate sizing and positioning of the femoral component in hip resurfacing.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 150 - 151
1 Jan 2004
KIM HJ


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 371 - 375
1 Apr 2003
Reis ND Schwartz O Militianu D Ramon Y Levin D Norman D Melamed Y Shupak A Goldsher D Zinman C

A vascular necrosis (AVN) of the head of the femur is a potentially crippling disease which mainly affects young adults. Although treatment by exposure to hyperbaric oxygen (HBO) is reported as being beneficial, there has been no study of its use in treated compared with untreated patients. We selected 12 patients who suffered from Steinberg stage-I AVN of the head of the femur (four bilateral) whose lesions were 4 mm or more thick and/or 12.5 mm or more long on MRI. Daily HBO therapy was given for 100 days to each patient. All smaller stage-I lesions and more advanced stages of AVN were excluded. These size criteria were chosen in order to compare outcomes with an identical size of lesion in an untreated group described earlier. Overall, 81% of patients who received HBO therapy showed a return to normal on MRI as compared with 17% in the untreated group. We therefore conclude that hyperbaric oxygen is effective in the treatment of stage-I AVN of the head of the femur.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 681 - 682
1 Jul 1996
LAFFORGUE P CHAGNAUD C ACQUAVIVA PC ARGENSON JN AUBANIAC JM


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 365 - 367
1 May 1993
Fordyce M Solomon L

We used MRI to examine the hips of 32 asymptomatic patients at 9 to 21 months after renal transplantation covered by high-dose corticosteroids. Five hips in three patients showed changes which indicate avascular necrosis, although radiographs, CT scans and isotope scans were normal. These patients had repeat MRI scans after another two years and three years. One patient with bilateral MRI changes developed symptoms and abnormal radiographs and CT and isotope scans in one hip nine months after the abnormal MRI. Intraosseous pressure was found to be raised in both hips, and core biopsies revealed necrotic bone on both sides. The other three hips have remained asymptomatic with unchanged MRI appearances three years after the initial MRI. It seems that idiopathic avascular necrosis does not always progress to bone collapse in the medium term.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 866 - 866
1 Sep 1991
Mills C Hooper J


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 2 | Pages 389 - 389
1 May 1972
Chalmers J


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 2 | Pages 354 - 355
1 May 1969
StougĂȘard J

Two cases of post-traumatic avascular necrosis of the head of the femur without evident dislocation of the head or fracture of the head or neck are recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 4 | Pages 854 - 857
1 Nov 1962
Price ER


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 1 | Pages 28 - 30
1 Feb 1960
Charnley J


The Journal of Bone & Joint Surgery British Volume
Vol. 34-B, Issue 2 | Pages 173 - 180
1 May 1952
Robert Judet J

At the end of this short study we have to sum up our views about the use of the acrylic prosthesis for arthroplasty of the hip. Some fatalities and a proportion of bad or poor results make this operation one to be undertaken only by surgeons well trained in the surgery of the hip and only on patients who really need it. However, the tolerance of the tissues to acrylic resin and the fixation of the stem in the neck of the femur promise to be lasting. We know that a much longer time is necessary to confirm these general statements, which proceed from an experience of only five years and the study of six hundred cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 33-B, Issue 1 | Pages 119 - 121
1 Feb 1951
Gibson A Williams TH


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 530 - 532
1 Nov 1983
Scales J