Advertisement for orthosearch.org.uk
Results 1 - 20 of 859
Results per page:
Bone & Joint Open
Vol. 2, Issue 7 | Pages 486 - 492
8 Jul 2021
Phelps EE Tutton E Costa M Hing C

Aims. To explore staff experiences of a multicentre pilot randomized controlled trial (RCT) comparing intramedullary nails and circular frame external fixation for segmental tibial fractures. Methods. A purposeful sample of 19 staff (nine surgeons) involved in the study participated in an interview. Interviews explored participants’ experience and views of the study and the treatments. The interviews drew on phenomenology, were face-to-face or by telephone, and were analyzed using thematic analysis. Results. The findings identify that for the treatment of segmental tibial fractures equipoise was a theoretical ideal that was most likely unattainable in clinical practice. This was conveyed through three themes: the ambiguity of equipoise, where multiple definitions of equipoise and a belief in community equipoise were evident; an illusion of equipoise, created by strong treatment preferences and variation in collective surgical skills; and treating the whole patient, where the complexity and severity of the injury required a patient-centred approach and doing the best for the individual patient took priority over trial recruitment. Conclusion. Equipoise can be unattainable for rare injuries such as segmental tibial fractures, where there are substantially different surgical treatments requiring specific expertise, high levels of complexity, and a concern for poor outcomes. Surgeons are familiar with community equipoise. However, a shared understanding of factors that limit the feasibility of RCTs may identify instances where community equipoise is unlikely to translate into practice. Cite this article: Bone Jt Open 2021;2(7):486–492


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1132 - 1141
1 Oct 2022
Holm-Glad T Røkkum M Röhrl SM Roness S Godang K Reigstad O

Aims. To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour. Methods. A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared. Results. Patient-Rated Wrist and Hand Evaluation (PRWHE) scores, abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) scores, and pain improved similarly and significantly in both groups. Wrist motion improved significantly in the Motec group only, and forearm rotation in the ReMotion group only. Cobalt (Co) and chromium (Cr) blood ion levels were significantly higher in the metal-on-metal (MoM) Motec group than in the metal-on-polyethylene (MoP) ReMotion group. Mean total translation was 0.65 mm (95% confidence interval (CI) 0.26 to 1.12) and 0.27 mm (95% CI 0.14 to 0.47) for the ReMotion carpal and radial components, and 0.32 mm (95% CI 0.22 to 0.45) and 0.26 mm (95% CI 0.20 to 0.34) for the Motec metacarpal and radial components, respectively. Apart from dorsal and volar tilts, which were significantly higher for the radial ReMotion than for the Motec component, no significant differences in absolute migration occurred. BMD around the radial components never returned to baseline. Almost one-third of patients required reoperation due to complications. Two ReMotion implants were revised to Motec TWAs due to carpal component loosening, and three Motec MoM articulations were revised to metal-on-polyether ether ketone due to painful synovitis. Conclusion. Both implants provided matched function and were stable at short-term follow-up, but with a high complication rate. This procedure should be restricted to specialist centres undertaking prospective analysis until its role is clarified. Cite this article: Bone Joint J 2022;104-B(10):1132–1141


Bone & Joint Open
Vol. 5, Issue 3 | Pages 162 - 173
4 Mar 2024
Di Mascio L Hamborg T Mihaylova B Kassam J Shah B Stuart B Griffin XL

Aims. Is it feasible to conduct a definitive multicentre trial in community settings of corticosteroid injections (CSI) and hydrodilation (HD) compared to CSI for patients with frozen shoulder? An adequately powered definitive randomized controlled trial (RCT) delivered in primary care will inform clinicians and the public whether hydrodilation is a clinically and cost-effective intervention. In this study, prior to a full RCT, we propose a feasibility trial to evaluate recruitment and retention by patient and clinician willingness of randomization; rates of withdrawal, crossover and attrition; and feasibility of outcome data collection from routine primary and secondary care data. Methods. In the UK, the National Institute for Health and Care Excellence (NICE) advises that prompt early management of frozen shoulder is initiated in primary care settings with analgesia, physiotherapy, and joint injections; most people can be managed without an operation. Currently, there is variation in the type of joint injection: 1) CSI, thought to reduce the inflammation of the capsule reducing pain; and 2) HD, where a small volume of fluid is injected into the shoulder joint along with the steroid, aiming to stretch the capsule of the shoulder to improve pain, but also allowing greater movement. The creation of musculoskeletal hubs nationwide provides infrastructure for the early and effective management of frozen shoulder. This potentially reduces costs to individuals and the wider NHS perhaps negating the need for a secondary care referral. Results. We will conduct a multicentre RCT comparing CSI and HD in combination with CSI alone. Patients aged 18 years and over with a clinical diagnosis of frozen shoulder will be randomized and blinded to receive either CSI and HD in combination, or CSI alone. Feasibility outcomes include the rate of randomization as a proportion of eligible patients and the ability to use routinely collected data for outcome evaluation. This study has involved patients and the public in the trial design, dissemination methods, and how to include groups who are underserved by research. Conclusion. We will disseminate findings among musculoskeletal clinicians via the British Orthopaedic Association, the Chartered Society of Physiotherapy, the Royal College of Radiologists, and the Royal College of General Practitioners. To ensure wide reach we will communicate findings through our established network of charities and organizations, in addition to preparing dissemination findings in Bangla and Urdu (commonly spoken languages in northeast London). If a full trial is shown to be feasible, we will seek additional National Institute for Health and Care Research funding for a definitive RCT. This definitive study will inform NICE guidelines for the management of frozen shoulder. Cite this article: Bone Jt Open 2024;5(3):162–173


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims. The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). Methods. A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years. Results. The BCR-TKA demonstrated a kinematic pattern comparable to the natural knee’s screw-home mechanism in the step-up task. In the lunge task, the medial CP of the BCR-TKA was more anterior in the early flexion phase, while laterally the CP was more posterior during the entire movement cycle. The BCR-TKA group showed higher tibial migration. No differences were found for the clinical and functional outcomes. Conclusion. The BCR-TKA shows a different kinematic pattern in early flexion/late extension compared to the CR-TKA. The difference between both implants is mostly visible in the flexion phase in which the anterior cruciate ligament is effective; however, both designs fail to fully replicate the motion of a natural knee. The higher migration of the BCR-TKA was concerning and highlights the importance of longer follow-up. Cite this article: Bone Joint J 2023;105-B(1):35–46


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 961 - 970
1 Sep 2023
Clement ND Galloway S Baron YJ Smith K Weir DJ Deehan DJ

Aims. The primary aim was to assess whether robotic total knee arthroplasty (rTKA) had a greater early knee-specific outcome when compared to manual TKA (mTKA). Secondary aims were to assess whether rTKA was associated with improved expectation fulfilment, health-related quality of life (HRQoL), and patient satisfaction when compared to mTKA. Methods. A randomized controlled trial was undertaken, and patients were randomized to either mTKA or rTKA. The primary objective was functional improvement at six months. Overall, 100 patients were randomized, 50 to each group, of whom 46 rTKA and 41 mTKA patients were available for review at six months following surgery. There were no differences between the two groups. Results. There was no difference between rTKA and mTKA groups at six months according to the Western Ontario and McMaster Universities osteoarthritis index (WOMAC) functional score (mean difference (MD) 3.8 (95% confidence interval (CI) -5.6 to 13.1); p = 0.425). There was a greater improvement in the WOMAC pain score at two months (MD 9.5 (95% CI 0.6 to 18.3); p = 0.037) in the rTKA group, although by six months no significant difference was observed (MD 6.7 (95% CI -3.6 to 17.1); p = 0.198). The rTKA group were more likely to achieve a minimal important change in their WOMAC pain score when compared to the mTKA group at two months (n = 36 (78.3%) vs n = 24 (58.5%); p = 0.047) and at six months (n = 40 (87.0%) vs n = 29 (68.3%); p = 0.036). There was no difference in satisfaction between the rTKA group (97.8%; n = 45/46) and the mTKA group (87.8%; n = 36/41) at six months (p = 0.096). There were no differences in EuroQol five-dimension questionnaire (EQ-5D) utility gain (p ≥ 0.389) or fulfilment of patient expectation (p ≥ 0.054) between the groups. Conclusion. There were no statistically significant or clinically meaningful differences in the change in WOMAC function between mTKA and rTKA at six months. rTKA was associated with a higher likelihood of achieving a clinically important change in knee pain at two and six months, but no differences in knee-specific function, patient satisfaction, health-related quality of life, or expectation fulfilment were observed. Cite this article: Bone Joint J 2023;105-B(9):961–970


Bone & Joint Research
Vol. 10, Issue 12 | Pages 807 - 819
1 Dec 2021
Wong RMY Wong PY Liu C Chung YL Wong KC Tso CY Chow SK Cheung W Yung PS Chui CS Law SW

Aims. The use of 3D printing has become increasingly popular and has been widely used in orthopaedic surgery. There has been a trend towards an increasing number of publications in this field, but existing literature incorporates limited high-quality studies, and there is a lack of reports on outcomes. The aim of this study was to perform a scoping review with Level I evidence on the application and effectiveness of 3D printing. Methods. A literature search was performed in PubMed, Embase, and Web of Science databases. The keywords used for the search criteria were ((3d print*) OR (rapid prototyp*) OR (additive manufactur*)) AND (orthopaedic). The inclusion criteria were: 1) use of 3D printing in orthopaedics, 2) randomized controlled trials, and 3) studies with participants/patients. Risk of bias was assessed with Cochrane Collaboration Tool and PEDro Score. Pooled analysis was performed. Results. Overall, 21 studies were included in our study with a pooled total of 932 participants. Pooled analysis showed that operating time (p < 0.001), blood loss (p < 0.001), fluoroscopy times (p < 0.001), bone union time (p < 0.001), pain (p = 0.040), accuracy (p < 0.001), and functional scores (p < 0.001) were significantly improved with 3D printing compared to the control group. There were no significant differences in complications. Conclusion. 3D printing is a rapidly developing field in orthopaedics. Our findings show that 3D printing is advantageous in terms of operating time, blood loss, fluoroscopy times, bone union time, pain, accuracy, and function. The use of 3D printing did not increase the risk of complications. Cite this article: Bone Joint Res 2021;10(12):807–819


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 728 - 734
1 Jul 2024
Poppelaars MA van der Water L Koenraadt-van Oost I Boele van Hensbroek P van Bergen CJA

Aims. Paediatric fractures are highly prevalent and are most often treated with plaster. The application and removal of plaster is often an anxiety-inducing experience for children. Decreasing the anxiety level may improve the patients’ satisfaction and the quality of healthcare. Virtual reality (VR) has proven to effectively distract children and reduce their anxiety in other clinical settings, and it seems to have a similar effect during plaster treatment. This study aims to further investigate the effect of VR on the anxiety level of children with fractures who undergo plaster removal or replacement in the plaster room. Methods. A randomized controlled trial was conducted. A total of 255 patients were included, aged five to 17 years, who needed plaster treatment for a fracture of the upper or lower limb. Randomization was stratified for age (five to 11 and 12 to 17 years). The intervention group was distracted with VR goggles and headphones during the plaster treatment, whereas the control group received standard care. As the primary outcome, the post-procedural level of anxiety was measured with the Child Fear Scale (CFS). Secondary outcomes included the children’s anxiety reduction (difference between CFS after and CFS before plaster procedure), numerical rating scale (NRS) pain, NRS satisfaction of the children and accompanying parents/guardians, and the children’s heart rates during the procedure. An independent-samples t-test and Mann-Whitney U test (depending on the data distribution) were used to analyze the data. Results. The post-procedural CFS was significantly lower (p < 0.001) in the intervention group (proportion of children with no anxiety = 78.6%) than in the control group (56.8%). The anxiety reduction, NRS pain and satisfaction scores, and heart rates showed no significant differences between the control group and the intervention group. Subanalyses showed an increased effect of VR on anxiety levels in young patients, females, upper limb fractures, and those who had had previous plaster treatment. Conclusion. VR effectively reduces the anxiety levels of children in the plaster room, especially in young girls. No statistically significant effects were seen regarding pain, heart rate, or satisfaction scores. Cite this article: Bone Joint J 2024;106-B(7):728–734


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 619 - 626
1 Apr 2021
Tolk JJ Janssen RPA Haanstra TM van der Steen MC Bierma-Zeinstra SMA Reijman M

Aims. Meeting preoperative expectations is known to be of major influence on postoperative satisfaction after total knee arthroplasty (TKA). Improved management of expectation, resulting in more realistic expectations can potentially lead to higher postoperative satisfaction. The objective of this study was to assess the effect of an additional preoperative education module, addressing realistic expectations for long-term functional recovery, on postoperative satisfaction and expectation fulfilment. Methods. In total, 204 primary TKA patients with osteoarthritis were enrolled in this randomized controlled trial (RCT). Patients were allocated to either usual preoperative education (control group) or usual education plus an additional module on realistic expectations (intervention group). Primary outcome was being very satisfied (numerical rating scale for satisfaction ≥ 8) with the treatment result at 12 months' follow-up. Other outcomes were change in preoperative expectations and postoperative expectation fulfilment. Results. A total of 187 patients (91.7%) were available for analysis at follow-up. In the intention-to-treat analysis, 58.5% (55/94) of patients were very satisfied with the treatment result in the control group, and 69.9% (65/93) of patients in the intervention group (adjusted odds ratio (AOR) 1.72, 95% confidence interval (CI) 0.90 to 3.29). A per-protocol analysis for patients who attended the education session (92.0%, n = 172) showed that 56.9% (49/86) of patients were very satisfied in the control group and 74.4% (61/86) in the intervention group (AOR 2.44, 95% CI 1.21 to 4.91). After preoperative education, the expectation scores in the intervention group were significantly lower (mean difference -6.9 (95% CI -10.2 to -3.6)) and did not alter in the control group (mean difference 0.5 (95% CI -2.9 to 3.9)). Overall, fulfilment of expectations at 12 months was significantly higher in the intervention group (mean difference 11.4% (95% CI 2.3 to 20.5)). Conclusion. Improved preoperative patient education can modify patient expectations, resulting in higher postoperative fulfilment of expectation and higher satisfaction in the group that attended the preoperative education. This is the first RCT to confirm the potential of improved expectation management on satisfaction after TKA. Cite this article: Bone Joint J 2021;103-B(4):619–626


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1081 - 1088
1 Sep 2022
Behman AL Bradley CS Maddock CL Sharma S Kelley SP

Aims. There is no consensus regarding optimum timing and frequency of ultrasound (US) for monitoring response to Pavlik harness (PH) treatment in developmental dysplasia of the hip (DDH). The purpose of our study was to determine if a limited-frequency hip US assessment had an adverse effect on treatment outcomes compared to traditional comprehensive US monitoring. Methods. This study was a single-centre noninferiority randomized controlled trial. Infants aged under six months whose hips were reduced and centred in the harness at initiation of treatment (stable dysplastic or subluxable), or initially decentred (subluxated or dislocated) but reduced and centred within four weeks of PH treatment, were randomized to our current standard US monitoring protocol (every clinic visit) or to a limited-frequency US protocol (US only at end of treatment). Groups were compared based on α angle and femoral head coverage at the end of PH treatment, acetabular indices, and International Hip Dysplasia Institute (IHDI) grade on one-year follow-up radiographs. Results. Overall, 100 patients were included; 42 patients completed the standard protocol (SP) and 40 completed the limited protocol (LP). There was no significant difference in mean right α angle at the end of treatment (SP 70.0° (SD 3.2°) ; LP 68.7° (SD 2.9°); p = 0.033), nor on the left (SP 69.0° (SD 3.5°); LP 68.1° (SD 3.3°); p = 0.128). There was no significant difference in mean right acetabular index at follow-up (SP 23.1° (SD 4.3°); LP 22.0° (SD 4.1°); p = 0.129), nor on the left (SP 23.3° (SD 4.2°); LP 22.8° (SD 3.9°); p = 0.284). All hips had femoral head coverage of > 50% at end of treatment, and all were IHDI grade 1 at follow-up. In addition, the LP group underwent a 60% reduction in US use once stable. Conclusion. Our study supports reducing the frequency of US assessment during PH treatment of DDH once a hip is reduced and centred. Cite this article: Bone Joint J 2022;104-B(9):1081–1088


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 324 - 335
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS

Aims. Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. Methods. This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery. Results. There were no significant differences for any of the baseline characteristics including spinopelvic mobility. The absolute error for achieving the planned horizontal COR was median 1.4 mm (interquartile range (IQR) 0.87 to 3.42) in RO THA versus 4.3 mm (IQR 3 to 6.8; p < 0.001); vertical COR mean 0.91 mm (SD 0.73) in RO THA versus 2.3 mm (SD 1.3; p < 0.001); and combined offset median 2 mm (IQR 0.97 to 5.45) in RO THA versus 3.9 mm (IQR 2 to 7.9; p = 0.019). Improved accuracy was observed with RO THA in achieving the desired acetabular component positioning (root mean square error for anteversion and inclination was 2.6 and 1.3 vs 8.9 and 5.3, repectively) and leg length (mean 0.6 mm vs 1.4 mm; p < 0.001). Patient-reported outcome measures were comparable between the two groups at baseline and one year. Participants in the RO THA group needed fewer physiotherapy sessions postoperatively (median six (IQR 4.5 to 8) vs eight (IQR 6 to 11; p = 0.005). Conclusion. This RCT suggested that robotic-arm assistance in THA was associated with improved accuracy in restoring the native COR, better preservation of the combined offset, leg length correction, and superior accuracy in achieving the desired acetabular component positioning. Further evaluation through long-term and registry data is necessary to assess whether these findings translate into improved implant survival and functional outcomes. Cite this article: Bone Joint J 2024;106-B(4):324–335


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 875 - 883
1 Jul 2022
Mills K Wymenga AB van Hellemondt GG Heesterbeek PJC

Aims. Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). Methods. This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction). Results. The median total femoral translation and rotation at ten years were 0.39 mm (interquartile range (IQR) 0.20 to 0.54) and 0.59° (IQR 0.46° to 0.73°) for the cemented group and 0.70 mm (IQR 0.15 to 0.77) and 0.78° (IQR 0.47° to 1.43°) for the hybrid group. For the tibial components this was 0.38 mm (IQR 0.33 to 0.85) and 0.98° (IQR 0.38° to 1.34°) for the cemented group and 0.42 mm (IQR 0.30 to 0.52) and 0.72° (IQR 0.62° to 0.82°) for the hybrid group. None of these values were significantly different between the two groups and there were no significant differences between the clinical scores in the two groups at this time. There was only one re-revision, in the hybrid group, for infection and not for aseptic loosening. Conclusion. These results show good long-term fixation with no difference in micromotion and clinical outcome between fully cemented and hybrid fixation in rTKA, which builds on earlier short- to mid-term results. The patients all had type I or II osseous defects, which may in part explain the good results. Cite this article: Bone Joint J 2022;104-B(7):875–883


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1093 - 1099
1 Sep 2019
Bradley KE Ryan SP Penrose CT Grant SA Wellman SS Attarian DE Green CL Risoli T Bolognesi MP

Aims. Antifibrinolytic agents, including tranexamic acid (TXA) and epsilon-aminocaproic acid (EACA), have been shown to be safe and effective for decreasing perioperative blood loss and transfusion following total hip arthroplasty (THA) and total knee arthroplasty (TKA). However, there are few prospective studies that directly compare these agents. The purpose of this study was to compare the benefits of intraoperative intravenous TXA with EACA. Patients and Methods. A total of 235 patients (90 THA and 145 TKA) were enrolled in this prospective, randomized controlled trial at a single tertiary-care referral centre. In the THA cohort, 53.3% of the patients were female with a median age of 59.8 years (interquartile range (IQR) 53.3 to 68.1). In the TKA cohort, 63.4% of the patients were female with a median age of 65.1 years (IQR 59.4 to 69.5). Patients received either TXA (n = 119) or EACA (n = 116) in two doses intraoperatively. The primary outcome measures included change in haemoglobin level and blood volume, postoperative drainage, and rate of transfusion. Secondary outcome measures included postoperative complications, cost, and length of stay (LOS). Results. TKA patients who received EACA had greater drainage (median 320 ml (IQR 185 to 420) vs 158 ml (IQR 110 to 238); p < 0.001), increased loss of blood volume (891 ml (IQR 612 to 1203) vs 661 ml (IQR 514 to 980); p = 0.014), and increased haemoglobin change from the preoperative level (2.1 ml (IQR 1.7 to 2.8) vs 1.9 ml (IQR 1.2 to 2.4); p = 0.016) compared with patients who received TXA. For the THA cohort, no statistically significant differences were observed in any haematological outcome measure. One patient in the EACA group required transfusion. No patient in the TXA group required transfusion. There were no statistically significant differences in number or type of postoperative complications or LOS for either THA or TKA patients regardless of whether they received TXA or EACA. Conclusion. For hip and knee arthroplasty procedures, EACA is associated with increased perioperative blood loss compared with TXA. However, there is no significant difference in transfusion rate. While further prospective studies are needed to compare the efficacy of each agent, we currently recommend orthopaedic surgeons to select their antifibrinolytic based on cost and regional availability. Cite this article: Bone Joint J 2019;101-B:1093–1099


Bone & Joint Open
Vol. 2, Issue 8 | Pages 631 - 637
10 Aug 2021
Realpe AX Blackstone J Griffin DR Bing AJF Karski M Milner SA Siddique M Goldberg A

Aims. A multicentre, randomized, clinician-led, pragmatic, parallel-group orthopaedic trial of two surgical procedures was set up to obtain high-quality evidence of effectiveness. However, the trial faced recruitment challenges and struggled to maintain recruitment rates over 30%, although this is not unusual for surgical trials. We conducted a qualitative study with the aim of gathering information about recruitment practices to identify barriers to patient consent and participation to an orthopaedic trial. Methods. We collected 11 audio recordings of recruitment appointments and interviews of research team members (principal investigators and research nurses) from five hospitals involved in recruitment to an orthopaedic trial. We analyzed the qualitative data sets thematically with the aim of identifying aspects of informed consent and information provision that was either unclear, disrupted, or hindered trial recruitment. Results. Recruiters faced four common obstacles when recruiting to a surgical orthopaedic trial: patient preferences for an intervention; a complex recruitment pathway; various logistical issues; and conflicting views on equipoise. Clinicians expressed concerns that the trial may not show significant differences in the treatments, validating their equipoise. However, they experienced role conflicts due to their own preference and perceived patient preference for an intervention arm. Conclusion. This study provided initial information about barriers to recruitment to an orthopaedic randomized controlled trial. We shared these findings in an all-site investigators’ meeting and encouraged researchers to find solutions to identified barriers; this led to the successful completion of recruitment. Complex trials may benefit for using of a mixed-methods approach to mitigate against recruitment failure, and to improve patient participation and informed consent. Cite this article: Bone Jt Open 2021;2(8):631–637


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 949 - 956
1 Sep 2024
Matthews PA Scammell BE Coughlin TA Nightingale J Ollivere BJ

Aims. This study aimed to compare the outcomes of two different postoperative management approaches following surgical fixation of ankle fractures: traditional cast immobilization versus the Early Motion and Directed Exercise (EMADE) programme. Methods. A total of 157 patients aged 18 years or older who underwent successful open reduction and internal fixation (ORIF) of Weber B (AO44B) ankle fractures were recruited to this randomized controlled trial. At two weeks post-surgical fixation, participants were randomized to either light-weight cast-immobilization or the EMADE programme, consisting of progressive home exercises and weekly advice and education. Both groups were restricted to non-weightbearing until six weeks post-surgery. The primary outcome was assessed using the Olerud-Molander Ankle Score (OMAS) questionnaire at 12 weeks post-surgery, with secondary measures at two, six, 24, and 52 weeks. Exploratory cost-effectiveness analyses were also performed. Results. Overall, 130 participants returned their 12-week OMAS questionnaires. The mean OMAS was significantly higher in the EMADE group compared with the immobilized group (62.0 (SD 20.9) vs 48.8 (SD 22.5)), with a clinically meaningful mean difference of 13.2 (95% CI 5.66 to 20.73; p < 0.001). These differences were maintained at week 24, with convergence by week 52. No intervention-related adverse events, including instability, were reported. Conclusion. The EMADE programme demonstrated an accelerated recovery compared to traditional six-week cast immobilization for those who have undergone ORIF surgery to stabilize Weber B (AO44B) ankle fractures. The study found the EMADE intervention to be safe. Cite this article: Bone Joint J 2024;106-B(9):949–956


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 91 - 97
1 Jul 2021
Crawford DA Lombardi AV Berend KR Huddleston JI Peters CL DeHaan A Zimmerman EK Duwelius PJ

Aims. The purpose of this study is to evaluate early outcomes with the use of a smartphone-based exercise and educational care management system after total hip arthroplasty (THA) and demonstrate decreased use of in-person physiotherapy (PT). Methods. A multicentre, prospective randomized controlled trial was conducted to evaluate a smartphone-based care platform for primary THA. Patients randomized to the control group (198) received the institution’s standard of care. Those randomized to the treatment group (167) were provided with a smartwatch and smartphone application. PT use, THA complications, readmissions, emergency department/urgent care visits, and physician office visits were evaluated. Outcome scores include the Hip disability and Osteoarthritis Outcome Score (HOOS, JR), health-related quality-of-life EuroQol five-dimension five-level score (EQ-5D-5L), single leg stance (SLS) test, and the Timed Up and Go (TUG) test. Results. The control group was significantly younger by a mean 3.0 years (SD 9.8 for control, 10.4 for treatment group; p = 0.007), but there were no significant differences between groups in BMI, sex, or preoperative diagnosis. Postoperative PT use was significantly lower in the treatment group (34%) than in the control group (55.4%; p = 0.001). There were no statistically significant differences in complications, readmissions, or outpatient visits. The 90-day outcomes showed no significant differences in mean hip flexion between controls (101° (SD 10.8)) and treatment (100° (SD 11.3); p = 0.507) groups. The HOOS, JR scores were not significantly different between control group (73 points (SD 13.8)) and treatment group (73.6 points (SD 13); p = 0.660). Mean 30-day SLS time was 22.9 seconds (SD 19.8) in the control group and 20.7 seconds (SD 19.5) in the treatment group (p = 0.342). Mean TUG time was 11.8 seconds (SD 5.1) for the control group and 11.9 (SD 5) seconds for the treatment group (p = 0.859). Conclusion. The use of the smartphone care management system demonstrated similar early outcomes to those achieved using traditional care models, along with a significant decrease in PT use. Noninferiority was demonstrated with regard to complications, readmissions, and ED and urgent care visits. This technology allows patients to rehabilitate on a more flexible schedule and avoid unnecessary healthcare visits, as well as potentially reducing overall healthcare costs. Cite this article: Bone Joint J 2021;103-B(7 Supple B):91–97


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 382 - 388
15 Mar 2023
Haque A Parsons H Parsons N Costa ML Redmond AC Mason J Nwankwo H Kearney RS

Aims. The aim of this study was to compare the longer-term outcomes of operatively and nonoperatively managed patients treated with a removable brace (fixed-angle removable orthosis) or a plaster cast immobilization for an acute ankle fracture. Methods. This is a secondary analysis of a multicentre randomized controlled trial comparing adults with an acute ankle fracture, initially managed either by operative or nonoperative care. Patients were randomly allocated to receive either a cast immobilization or a fixed-angle removable orthosis (removable brace). Data were collected on baseline characteristics, ankle function, quality of life, and complications. The Olerud-Molander Ankle Score (OMAS) was the primary outcome which was used to measure the participant’s ankle function. The primary endpoint was at 16 weeks, with longer-term follow-up at 24 weeks and two years. Results. Overall, 436 patients (65%) completed the final two-year follow-up. The mean difference in OMAS at two years was -0.3 points favouring the plaster cast (95% confidence interval -3.9 to 3.4), indicating no statistically significant difference between the interventions. There was no evidence of differences in patient quality of life (measured using the EuroQol five-dimension five-level questionnaire) or Disability Rating Index. Conclusion. This study demonstrated that patients treated with a removable brace had similar outcomes to those treated with a plaster cast in the first two years after injury. A removable brace is an effective alternative to traditional immobilization in a plaster cast for patients with an ankle fracture. Cite this article: Bone Joint J 2023;105-B(4):382–388


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 833 - 843
1 Jul 2022
Kayani B Baawa-Ameyaw J Fontalis A Tahmassebi J Wardle N Middleton R Stephen A Hutchinson J Haddad FS

Aims. This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). Methods. Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years’ follow-up. Results. Patients in Group C were associated with increased mean liner wear rates compared to patients in Group A (0.133 mm/yr (SD 0.21) vs 0.031 mm/yr (SD 0.07), respectively; p < 0.001) and Group B (0.133 mm/yr (SD 0.21) vs 0.022 mm/yr (SD 0.05), respectively; p < 0.001) at ten years’ follow-up. Patients in Group C were also associated with increased risk of osteolysis and aseptic loosening requiring revision surgery, compared with patients in Group A (7/133 vs 0/133, respectively; p = 0.007) and Group B (7/133 vs 0/135, respectively; p = 0.007). There was a non-statistically significant trend towards increased mean liner wear rates in Group A compared with Group B (0.031 mm/yr (SD 0.07) vs 0.022 mm/yr (SD 0.05), respectively; p = 0.128). All three groups were statistically comparable preoperatively and at ten years’ follow-up when measuring normalized Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.410), 36-Item Short Form Health Survey (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p = 0.451). Conclusion. The use of UHMWPE was associated with progressively increased annual liner wear rates after THA compared to XLPE. At ten years’ follow-up, the group receiving UHMWPE demonstrated an increased incidence of osteolysis and aseptic loosening requiring revision surgery compared to XLPE. Femoral heads composed of OxZr were associated with trend towards reduced wear rates compared to CoCr, but this did not reach statistical significance and did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two femoral head components. Cite this article: Bone Joint J 2022;104-B(7):833–843


Aims. Nearly 99,000 total knee arthroplasties (TKAs) are performed in UK annually. Despite plenty of research, the satisfaction rate of this surgery is around 80%. One of the important intraoperative factors affecting the outcome is alignment. The relationship between joint obliquity and functional outcomes is not well understood. Therefore, a study is required to investigate and compare the effects of two types of alignment (mechanical and kinematic) on functional outcomes and range of motion. Methods. The aim of the study is to compare navigated kinematically aligned TKAs (KA TKAs) with navigated mechanically aligned TKA (MA TKA) in terms of function and ROM. We aim to recruit a total of 96 patients in the trial. The patients will be recruited from clinics of various consultants working in the trust after screening them for eligibility criteria and obtaining their informed consent to participate in this study. Randomization will be done prior to surgery by a software. The primary outcome measure will be the Knee injury and Osteoarthritis Outcome Score The secondary outcome measures include Oxford Knee Score, ROM, EuroQol five-dimension questionnaire, EuroQol visual analogue scale, 12-Item Short-Form Health Survey (SF-12), and Forgotten Joint Score. The scores will be calculated preoperatively and then at six weeks, six months, and one year after surgery. The scores will undergo a statistical analysis. Discussion. There is no clear evidence on the best alignment for a knee arthroplasty. This randomized controlled trial will test the null hypothesis that navigated KA TKAs do not perform better than navigated MA TKAs. Cite this article: Bone Jt Open 2021;2(11):945–950


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1561 - 1570
1 Oct 2021
Blyth MJG Banger MS Doonan J Jones BG MacLean AD Rowe PJ

Aims. The aim of this study was to compare the clinical outcomes of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) during the first six weeks and at one year postoperatively. Methods. A per protocol analysis of 76 patients, 43 of whom underwent TKA and 34 of whom underwent bi-UKA, was performed from a prospective, single-centre, randomized controlled trial. Diaries kept by the patients recorded pain, function, and the use of analgesics daily throughout the first week and weekly between the second and sixth weeks. Patient-reported outcome measures (PROMs) were compared preoperatively, and at three months and one year postoperatively. Data were also compared longitudinally and a subgroup analysis was conducted, stratified by preoperative PROM status. Results. Both operations were shown to offer comparable outcomes, with no significant differences between the groups across all timepoints and outcome measures. Both groups also had similarly low rates of complications. Subgroup analysis for preoperative psychological state, activity levels, and BMI showed no difference in outcomes between the two groups. Conclusion. Robotic arm-assisted, cruciate-sparing bi-UKA offered similar early clinical outcomes and rates of complications to a mechanically aligned TKA, both in the immediate postoperative period and up to one year following surgery. Further work is required to identify which patients with osteoarthritis of the knee will derive benefit from a cruciate-sparing bi-UKA. Cite this article: Bone Joint J 2021;103-B(10):1561–1570


Aims. The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. Methods. A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model. Results. Both interventions were shown to be effective treatment options, with no significant differences shown between interventions for the primary outcome of this study (18/35 (51.4%) biphasic TKA patients vs 20/31 (64.5%) biphasic bi-UKA patients; p = 0.558). All outcomes were compared to an age-matched, healthy cohort that outperformed both groups, indicating residual deficits exists following surgery. Logistic regression analysis of primary outcome with secondary outcomes indicated that the most significant predictor of postoperative biphasic knee moments was preoperative knee moment profile and trochlear degradation (Outerbridge) (R. 2. = 0.381; p = 0.002, p = 0.046). A separate regression of alignment against primary outcome indicated significant bi-UKA femoral and tibial axial alignment (R. 2. = 0.352; p = 0.029), and TKA femoral sagittal alignment (R. 2. = 0.252; p = 0.016). The bi-UKA group showed a significant increased ability in the proprioceptive joint position test, but no difference was found in more dynamic testing of proprioception. Conclusion. Robotic arm-assisted bi-UKA demonstrated equivalence to TKA in achieving a biphasic gait pattern after surgery for osteoarthritis of the knee. Both treatments are successful at improving gait, but both leave the patients with a functional limitation that is not present in healthy age-matched controls. Cite this article: Bone Joint J 2022;103-B(4):433–443