Advertisement for orthosearch.org.uk
Results 1 - 20 of 471
Results per page:
Bone & Joint Open
Vol. 5, Issue 1 | Pages 3 - 8
2 Jan 2024
Husum H Hellfritzsch MB Maimburg RD Møller-Madsen B Henriksen M Lapitskaya N Kold S Rahbek O

Aims. The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%. Methods. We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots. Results. We included 2,735 newborns, of whom 754 received a follow-up hip ultrasound within six weeks of age. After exclusion, 1,500 hips were included for analysis. Sex distribution was 372 male and 380 female, and the mean age at examination was 36.6 days (4 to 87). We found a negative linear correlation of PFD to α angles (p < 0.001), FHC (p < 0.001), and FHC during provocation (p < 0.001) with a 1 mm increase in PFD corresponding to a -2.1° (95% confidence interval (CI) -2.3 to -1.9) change in α angle and a -3.4% (95% CI -3.7 to -3.0) change in FHC and a -6.0% (-6.6 to -5.5) change in FHC during provocation. The PFD was significantly higher with increasing Graf types and in displaceable hips (p < 0.001). Conclusion. PFD is strongly correlated to both α angles and hip displaceability, as measured by FHC and FHC during provocation, in ultrasound of newborn hips. The PFD increases as the hips become more dysplastic and/or displaceable. Cite this article: Bone Jt Open 2023;5(1):3–8


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1627 - 1632
4 Oct 2021
Farrow L Hall AJ Ablett AD Johansen A Myint PK

Aims. The aim of this study was to determine the impact of hospital-level service characteristics on hip fracture outcomes and quality of care processes measures. Methods. This was a retrospective analysis of publicly available audit data obtained from the National Hip Fracture Database (NHFD) 2018 benchmark summary and Facilities Survey. Data extraction was performed using a dedicated proforma to identify relevant hospital-level care process and outcome variables for inclusion. The primary outcome measure was adjusted 30-day mortality rate. A random forest-based multivariate imputation by chained equation (MICE) algorithm was used for missing value imputation. Univariable analysis for each hospital level factor was performed using a combination of Tobit regression, Siegal non-parametric linear regression, and Mann-Whitney U test analyses, dependent on the data type. In all analyses, a p-value < 0.05 denoted statistical significance. Results. Analyses included 176 hospitals, with a median of 366 hip fracture cases per year (interquartile range (IQR) 280 to 457). Aggregated data from 66,578 patients were included. The only identified hospital-level variable associated with the primary outcome of 30-day mortality was hip fracture trial involvement (no trial involvement: median 6.3%; trial involvement: median 5.7%; p = 0.039). Significant key associations were also identified between prompt surgery and presence of dedicated hip fracture sessions; reduced acute length of stay and both a higher number of hip fracture cases per year and more dedicated hip fracture operating lists; Best Practice Tariff attainment and greater number of hip fracture cases per year, more dedicated hip fracture operating lists, presence of a dedicated hip fracture ward, and hip fracture trial involvement. Conclusion. Exploratory analyses have identified that improved outcomes in hip fracture may be associated with hospital-level service characteristics, such as hip fracture research trial involvement, larger hip fracture volumes, and the use of theatre lists dedicated to hip fracture surgery. Further research using patient level data is warranted to corroborate these findings. Cite this article: Bone Joint J 2021;103-B(10):1627–1632


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1168 - 1173
1 Oct 2022
Gazendam AM Schneider P Vélez R Ghert M

Aims. The aim of this study was to determine the prevalence and impact of tourniquet use in patients undergoing limb salvage surgery with endoprosthetic reconstruction for a tumour around the knee. Methods. We retrieved data from the Prophylactic Antibiotic Regimens in Tumor Surgery (PARITY) trial; specifically, differences in baseline characteristics, surgical details, and postoperative functional outcomes between patients who had undergone surgery under tourniquet and those who had not. A linear regression model was created to evaluate the impact of tourniquet use on postoperative Toronto Extremity Salvage Scores (TESSs) while controlling for confounding variables. A negative-binomial regression model was constructed to explore predictors of postoperative length of stay (LOS). Results. Of the 604 patients enrolled in the PARITY trial, 421 had tumours around the knee joint, of whom 225 (53%) underwent surgery under tourniquet. The tourniquet group was younger (p = 0.014), more likely to undergo surgery for a tumour of the tibia, and had shorter operating times by a mean of 50 minutes (95% confidence interval 30 to 72; p < 0.001). The adjusted linear regression model found that the use of a tourniquet, a shorter operating time, and a higher baseline TESS independently predicted better function at both three- and six-month follow-up. The negative-binomial regression model showed that tourniquet use, shorter operating time, younger age, and intraoperative tranexamic acid administration independently predicted a shorter LOS in hospital. Conclusion. The results of this study show that in patients undergoing resection of a tumour around the knee and endoprosthetic reconstruction, the use of an intraoperative tourniquet is associated with a shorter operating time, a reduced length of stay in hospital, and a better early functional outcome. Cite this article: Bone Joint J 2022;104-B(10):1168–1173


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1057 - 1061
1 Dec 2021
Ahmad SS Weinrich L Giebel GM Beyer MR Stöckle U Konrads C

Aims. The aim of this study was to determine the association between knee alignment and the vertical orientation of the femoral neck in relation to the floor. This could be clinically important because changes of femoral neck orientation might alter chondral joint contact zones and joint reaction forces, potentially inducing problems like pain in pre-existing chondral degeneration. Further, the femoral neck orientation influences the ischiofemoral space and a small ischiofemoral distance can lead to impingement. We hypothesized that a valgus knee alignment is associated with a more vertical orientation of the femoral neck in standing position, compared to a varus knee. We further hypothesized that realignment surgery around the knee alters the vertical orientation of the femoral neck. Methods. Long-leg standing radiographs of patients undergoing realignment surgery around the knee were used. The hip-knee-ankle angle (HKA) and the vertical orientation of the femoral neck in relation to the floor were measured, prior to surgery and after osteotomy-site-union. Linear regression was performed to determine the influence of knee alignment on the vertical orientation of the femoral neck. Results. The cohort included 147 patients who underwent knee realignment-surgery. The mean age was 51.5 years (SD 11). Overall, 106 patients underwent a valgisation-osteotomy, while 41 underwent varisation osteotomy. There was a significant association between the orientation of the knee and the coronal neck-orientation. In the varus group, the median orientation of the femoral neck was 46.5° (interquartile range (IQR) 49.7° to 50.0°), while in the valgus group, the orientation was 52.0° (IQR 46.5° to 56.7°; p < 0.001). Linear regression analysis revealed that HKA demonstrated a direct influence on the coronal neck-orientation (β = 0.5 (95% confidence interval (CI) 0.2 to 0.7); p = 0.002). Linear regression also showed that realignment surgery was associated with a significant influence on the change in the coronal femoral neck orientation (β = 5.6 (95% CI 1.5 to 9.8); p = 0.008). Conclusion. Varus or valgus knee alignment is associated with either a more horizontal or a more vertical femoral neck orientation in standing position, respectively. Subsequently, osteotomies around the knee alter the vertical orientation of the femoral neck. These aspects are of importance when planning osteotomies around the knee in order to appreciate the effects on the adjacent hip joint. The concept may be of even more relevance in dysplastic hips. Cite this article: Bone Jt Open 2021;2(12):1057–1061


Bone & Joint Open
Vol. 3, Issue 1 | Pages 12 - 19
3 Jan 2022
Salih S Grammatopoulos G Burns S Hall-Craggs M Witt J

Aims. The lateral centre-edge angle (LCEA) is a plain radiological measure of superolateral cover of the femoral head. This study aims to establish the correlation between 2D radiological and 3D CT measurements of acetabular morphology, and to describe the relationship between LCEA and femoral head cover (FHC). Methods. This retrospective study included 353 periacetabular osteotomies (PAOs) performed between January 2014 and December 2017. Overall, 97 hips in 75 patients had 3D analysis by Clinical Graphics, giving measurements for LCEA, acetabular index (AI), and FHC. Roentgenographical LCEA, AI, posterior wall index (PWI), and anterior wall index (AWI) were measured from supine AP pelvis radiographs. The correlation between CT and roentgenographical measurements was calculated. Sequential multiple linear regression was performed to determine the relationship between roentgenographical measurements and CT FHC. Results. CT-measured LCEA and AI correlated strongly with roentgenographical LCEA (r = 0.92; p < 0.001) and AI (r = 0.83; p < 0.001). Radiological LCEA correlated very strongly with CT FHC (r = 0.92; p < 0.001). The sum of AWI and PWI also correlated strongly with CTFHC (r = 0.73; p < 0.001). CT measurements of LCEA and AI were 3.4° less and 2.3° greater than radiological LCEA and AI measures. There was a linear relation between radiological LCEA and CT FHC. The linear regression model statistically significantly predicted FHC from LCEA, F(1,96) = 545.1 (p < 0.001), adjusted R. 2. = 85.0%, with the prediction equation: CT FHC(%) = 42.1 + 0.77(XRLCEA). Conclusion. CT and roentgenographical measurement of acetabular parameters are comparable. Currently, a radiological LCEA greater than 25° is considered normal. This study demonstrates that those with hip pain and normal radiological acetabular parameters may still have deficiencies in FHC. More sophisticated imaging techniques such as 3D CT should be considered for those with hip pain to identify deficiencies in FHC. Cite this article: Bone Jt Open 2022;3(1):12–19


Bone & Joint Research
Vol. 13, Issue 9 | Pages 474 - 484
10 Sep 2024
Liu Y Li X Jiang L Ma J

Aims. Rotator cuff tear (RCT) is the leading cause of shoulder pain, primarily associated with age-related tendon degeneration. This study aimed to elucidate the potential differential gene expressions in tendons across different age groups, and to investigate their roles in tendon degeneration. Methods. Linear regression and differential expression (DE) analyses were performed on two transcriptome profiling datasets of torn supraspinatus tendons to identify age-related genes. Subsequent functional analyses were conducted on these candidate genes to explore their potential roles in tendon ageing. Additionally, a secondary DE analysis was performed on candidate genes by comparing their expressions between lesioned and normal tendons to explore their correlations with RCTs. Results. We identified 49 genes in torn supraspinatus tendons associated with advancing age. Among them, five age-related genes showed DE in lesioned tendons compared to normal tendons. Functional analyses and previous studies have highlighted their specific enrichments in biological functions, such as muscle development (e.g. myosin heavy chain 3 (MYH3)), transcription regulation (e.g. CCAAT enhancer binding brotein delta (CEBPD)), and metal ion homeostasis (e.g. metallothionein 1X (MT1X)). Conclusion. This study uncovered molecular aspects of tendon ageing and their potential links to RCT development, offering insights for targeted interventions. These findings enhance our understanding of the mechanisms of tendon degeneration, allowing potential strategies to be made for reducing the incidence of RCT. Cite this article: Bone Joint Res 2024;13(9):474–484


Bone & Joint Research
Vol. 13, Issue 11 | Pages 673 - 681
22 Nov 2024
Yue C Xue Z Cheng Y Sun C Liu Y Xu B Guo J

Aims. Pain is the most frequent complaint associated with osteonecrosis of the femoral head (ONFH), but the factors contributing to such pain are poorly understood. This study explored diverse demographic, clinical, radiological, psychological, and neurophysiological factors for their potential contribution to pain in patients with ONFH. Methods. This cross-sectional study was carried out according to the “STrengthening the Reporting of OBservational studies in Epidemiology” statement. Data on 19 variables were collected at a single timepoint from 250 patients with ONFH who were treated at our medical centre between July and December 2023 using validated instruments or, in the case of hip pain, a numerical rating scale. Factors associated with pain severity were identified using hierarchical multifactor linear regression. Results. Regression identified the following characteristics as independently associated with higher pain score, after adjustment for potential confounders: Association Research Circulation Osseous classification stage IIIa or IIIb, bone marrow oedema, grade 3 joint effusion, as well as higher scores on pain catastrophizing, anxiety, and central sensitization. The final model explained 69.7% of observed variance in pain scores, of which clinical and radiological factors explained 37%, while psychological and neurophysiological factors explained 24% and demographic factors explained 8.7%. Conclusion. Multidimensional characteristics jointly contribute to the severity of pain associated with ONFH. These findings highlight the need to comprehensively identify potential contributors to pain, and to personalize management and treatment accordingly. Cite this article: Bone Joint Res 2024;13(11):673–681


Bone & Joint Open
Vol. 3, Issue 10 | Pages 841 - 849
27 Oct 2022
Knight R Keene DJ Dutton SJ Handley R Willett K

Aims. The rationale for exacting restoration of skeletal anatomy after unstable ankle fracture is to improve outcomes by reducing complications from malunion; however, current definitions of malunion lack confirmatory clinical evidence. Methods. Radiological (absolute radiological measurements aided by computer software) and clinical (clinical interpretation of radiographs) definitions of malunion were compared within the Ankle Injury Management (AIM) trial cohort, including people aged ≥ 60 years with an unstable ankle fracture. Linear regressions were used to explore the relationship between radiological malunion (RM) at six months and changes in function at three years. Function was assessed with the Olerud-Molander Ankle Score (OMAS), with a minimal clinically important difference set as six points, as per the AIM trial. Piecewise linear models were used to investigate new radiological thresholds which better explain symptom impact on ankle function. Results. Previously described measures of RM and surgeon opinion of clinically significant malunion (CSM) were shown to be related but with important differences. CSM was more strongly related to outcome (-13.9 points on the OMAS; 95% confidence interval (CI) -21.9 to -5.4) than RM (-5.5 points; 95% CI -9.8 to -1.2). Existing malunion thresholds for talar tilt and tibiofibular clear space were shown to be slightly conservative; new thresholds which better explain function were identified (talar tilt > 2.4°; tibiofibular clear space > 6 mm). Based on this new definition the presence of RM had an impact on function, which was statistically significant, but the clinical significance was uncertain (-9.1 points; 95% CI -13.8 to -4.4). In subsequent analysis, RM of a posterior malleolar fracture was shown to have a statistically significant impact on OMAS change scores, but the clinical significance was uncertain (-11.6 points; 95% CI -21.9 to -0.6). Conclusion. These results provide clinical evidence which supports the previously accepted definitions. Further research to investigate more conservative clinical thresholds for malunion is indicated. Cite this article: Bone Jt Open 2022;3(10):841–849


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 687 - 695
1 Jun 2022
Sabah SA Knight R Alvand A Beard DJ Price AJ

Aims. Routinely collected patient-reported outcome measures (PROMs) have been useful to quantify and quality-assess provision of total hip arthroplasty (THA) and total knee arthroplasty (TKA) in the UK for the past decade. This study aimed to explore whether the outcome following primary THA and TKA had improved over the past seven years. Methods. Secondary data analysis of 277,430 primary THAs and 308,007 primary TKAs from the NHS PROMs programme was undertaken. Outcome measures were: postoperative Oxford Hip/Knee Score (OHS/OKS); proportion of patients achieving a clinically important improvement in joint function (responders); quality of life; patient satisfaction; perceived success; and complication rates. Outcome measures were compared based on year of surgery using multiple linear and logistic regression models. Results. For primary THA, multiple linear regression modelling found that more recent year of surgery was associated with higher postoperative OHS (unstandardized coefficient (B) 0.15 points (95% confidence interval (CI) 0.14 to 0.17); p < 0.001) and higher EuroQol five-dimension index (EQ-5D) utility (B 0.002 (95% CI 0.001 to 0.002); p < 0.001). The odds of being a responder (odds ratio (OR) 1.02 (95% CI 1.02 to 1.03); p < 0.001) and patient satisfaction (OR 1.02 (95% CI 1.01 to 1.03); p < 0.001) increased with year of surgery, while the odds of any complication reduced (OR 0.97 (95% CI 0.97 to 0.98); p < 0.001). No trend was found for perceived success (p = 0.555). For primary TKA, multiple linear regression modelling found that more recent year of surgery was associated with higher postoperative OKS (B 0.21 points (95% CI 0.19 to 0.22); p < 0.001) and higher EQ-5D utility (B 0.002 (95% CI 0.002 to 0.003); p < 0.001). The odds of being a responder (OR 1.04 (95% CI 1.03 to 1.04); p < 0.001), perceived success (OR 1.02 (95% CI 1.01 to 1.02); p < 0.001), and patient satisfaction (OR 1.02 (95% CI 1.01 to 1.02); p < 0.001) all increased with year of surgery, while the odds of any complication reduced (OR 0.97 (95% CI 0.97 to 0.97); p < 0.001). Conclusion. Nearly all patient-reported outcomes following primary THA/TKA improved by a small amount over the past seven years. Due to the high proportion of patients achieving good outcomes, PROMs following THA and TKA may need to focus on better discrimination of patients achieving high scores to be able to continue to measure improvement in outcomes. Cite this article: Bone Joint J 2022;104-B(6):687–695


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 85 - 90
1 Jun 2020
Blevins JL Rao V Chiu Y Lyman S Westrich GH

Aims. The purpose of this investigation was to determine the relationship between height, weight, and sex with implant size in total knee arthroplasty (TKA) using a multivariate linear regression model and a Bayesian model. Methods. A retrospective review of an institutional registry was performed of primary TKAs performed between January 2005 and December 2016. Patient demographics including patient age, sex, height, weight, and body mass index (BMI) were obtained from registry and medical record review. In total, 8,100 primary TKAs were included. The mean age was 67.3 years (SD 9.5) with a mean BMI of 30.4 kg/m. 2. (SD 6.3). The TKAs were randomly split into a training cohort (n = 4,022) and a testing cohort (n = 4,078). A multivariate linear regression model was created on the training cohort and then applied to the testing cohort . A Bayesian model was created based on the frequencies of implant sizes in the training cohort. The model was then applied to the testing cohort to determine the accuracy of the model at 1%, 5%, and 10% tolerance of inaccuracy. Results. Height had a relatively strong correlation with implant size (femoral component anteroposterior (AP) Pearson correlation coefficient (ρ) = 0.73, p < 0.001; tibial component mediolateral (ML) ρ = 0.77, p < 0.001). Weight had a moderately strong correlation with implant size, (femoral component AP ρ = 0.46, p < 0.001; tibial ML ρ = 0.48, p < 0.001). There was a significant linear correlation with height, weight, and sex with implant size (femoral component R. 2. = 0.607, p < 0.001; tibial R. 2. = 0.695, p < 0.001). The Bayesian model showed high accuracy in predicting the range of required implant sizes (94.4% for the femur and 96.6% for the tibia) accepting a 5% risk of inaccuracy. Conclusion. Implant size was correlated with basic demographic variables including height, weight, and sex. The linear regression and Bayesian models accurately predicted required implant sizes across multiple manufacturers based on height, weight, and sex alone. These types of predictive models may help improve operating room and implant supply chain efficiency. Level of Evidence: Level IV. Cite this article: Bone Joint J 2020;102-B(6 Supple A):85–90


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1003 - 1012
8 Nov 2024
Gabr A Fontalis A Robinson J Hage W O'Leary S Spalding T Haddad FS

Aims. The aim of this study was to compare patient-reported outcomes (PROMs) following isolated anterior cruciate ligament reconstruction (ACLR), with those following ACLR and concomitant meniscal resection or repair. Methods. We reviewed prospectively collected data from the UK National Ligament Registry for patients who underwent primary ACLR between January 2013 and December 2022. Patients were categorized into five groups: isolated ACLR, ACLR with medial meniscus (MM) repair, ACLR with MM resection, ACLR with lateral meniscus (LM) repair, and ACLR with LM resection. Linear regression analysis, with isolated ACLR as the reference, was performed after adjusting for confounders. Results. From 14,895 ACLR patients, 4,400 had two- or five-year Knee injury and Osteoarthritis Outcome Scores (KOOS) available. At two years postoperatively, the MM repair group demonstrated inferior scores in KOOS pain (β = −3.63, p < 0.001), symptoms (β = − 4.88, p < 0.001), ADL (β = − 2.43, p = 0.002), sport and recreation (β = − 5.23, p < 0.001), quality of life (QoL) (β = − 5.73, p < 0.001), and International Knee Documentation Committee (β = − 4.1, p < 0.001) compared with the isolated ACLR group. The LM repair group was associated with worse KOOS sports and recreation scores at two years (β = − 4.264, p < 0.001). At five years, PROMs were comparable between the groups. At five years, PROMs were comparable between the groups. Participants undergoing ACLR surgery within 12 weeks from index injury demonstrated superior PROMs at two and five years. Conclusion. Our study showed that MM repair, and to a lesser extent LM repairs in combination with ACLR, were associated with inferior patient-reported outcome measures (PROMs) compared to isolated ACLR at two years postoperatively, while meniscal resection groups exhibited comparable outcomes. However, by five years postoperation, no significant differences in PROMs were evident. Further longer-term, cross-sectional studies are warranted to investigate the outcomes of ACLR and concomitant meniscal surgery


Bone & Joint Research
Vol. 12, Issue 5 | Pages 313 - 320
8 May 2023
Saiki Y Kabata T Ojima T Kajino Y Kubo N Tsuchiya H

Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements. Results. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R. 2. of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3° fixed error in the extension position, compared to radiography. Conclusion. OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner’s skills. Cite this article: Bone Joint Res 2023;12(5):313–320


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1025 - 1031
1 Sep 2022
Thummala AR Xi Y Middleton E Kohli A Chhabra A Wells J

Aims. Pelvic tilt is believed to affect the symptomology of osteoarthritis (OA) of the hip by alterations in joint movement, dysplasia of the hip by modification of acetabular cover, and femoroacetabular impingement by influencing the impingement-free range of motion. While the apparent role of pelvic tilt in hip pathology has been reported, the exact effects of many forms of treatment on pelvic tilt are unknown. The primary aim of this study was to investigate the effects of surgery on pelvic tilt in these three groups of patients. Methods. The demographic, radiological, and outcome data for all patients operated on by the senior author between October 2016 and January 2020 were identified from a prospective registry, and all those who underwent surgery with a primary diagnosis of OA, dysplasia, or femoroacetabular impingement were considered for inclusion. Pelvic tilt was assessed on anteroposterior (AP) standing radiographs using the pre- and postoperative pubic symphysis to sacroiliac joint (PS-SI) distance, and the outcomes were assessed with the Hip Outcome Score (HOS), International Hip Outcome Tool (iHOT-12), and Harris Hip Score (HHS). Results. The linear regression model revealed a significant negative predictive association between the standing pre- and postoperative PS-SI distances for all three groups of patients (all p < 0.001). There was a significant improvement in all three outcome measures between the pre- and postoperative values (p < 0.05). Conclusion. There is a statistically significant decrease in pelvic tilt after surgery in patients with OA of the hip, dysplasia, and femoroacetabular impingement. These results confirm that surgery significantly alters the pelvic orientation. Pelvic tilt significantly decreased after total hip arthroplasty, periacetabular osteotomy, and arthroscopy/surgical hip dislocation. The impact of surgery on pelvic tilt should be considered within the therapeutic plan in order to optimize pelvic orientation in these patients. Cite this article: Bone Joint J 2022;104-B(9):1025–1031


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 394 - 400
1 Apr 2024
Kjærvik C Gjertsen J Stensland E Dybvik EH Soereide O

Aims. The aims of this study were to assess quality of life after hip fractures, to characterize respondents to patient-reported outcome measures (PROMs), and to describe the recovery trajectory of hip fracture patients. Methods. Data on 35,206 hip fractures (2014 to 2018; 67.2% female) in the Norwegian Hip Fracture Register were linked to data from the Norwegian Patient Registry and Statistics Norway. PROMs data were collected using the EuroQol five-dimension three-level questionnaire (EQ-5D-3L) scoring instrument and living patients were invited to respond at four, 12, and 36 months post fracture. Multiple imputation procedures were performed as a model to substitute missing PROM data. Differences in response rates between categories of covariates were analyzed using chi-squared test statistics. The association between patient and socioeconomic characteristics and the reported EQ-5D-3L scores was analyzed using linear regression. Results. The median age was 83 years (interquartile range 76 to 90), and 3,561 (10%) lived in a healthcare facility. Observed mean pre-fracture EQ-5D-3L index score was 0.81 (95% confidence interval 0.803 to 0.810), which decreased to 0.66 at four months, to 0.70 at 12 months, and to 0.73 at 36 months. In the imputed datasets, the reduction from pre-fracture was similar (0.15 points) but an improvement up to 36 months was modest (0.01 to 0.03 points). Patients with higher age, male sex, severe comorbidity, cognitive impairment, lower income, lower education, and those in residential care facilities had a lower proportion of respondents, and systematically reported a lower health-related quality of life (HRQoL). The response pattern of patients influenced scores significantly, and the highest scores are found in patients reporting scores at all observation times. Conclusion. Hip fracture leads to a persistent reduction in measured HRQoL, up to 36 months. The patients’ health and socioeconomic status were associated with the proportion of patients returning PROM data for analysis, and affected the results reported. Observed EQ-5D-3L scores are affected by attrition and selection bias mechanisms and motivate the use of statistical modelling for adjustment. Cite this article: Bone Joint J 2024;106-B(4):394–400


Bone & Joint Open
Vol. 3, Issue 7 | Pages 573 - 581
1 Jul 2022
Clement ND Afzal I Peacock CJH MacDonald D Macpherson GJ Patton JT Asopa V Sochart DH Kader DF

Aims. The aims of this study were to assess mapping models to predict the three-level version of EuroQoL five-dimension utility index (EQ-5D-3L) from the Oxford Knee Score (OKS) and validate these before and after total knee arthroplasty (TKA). Methods. A retrospective cohort of 5,857 patients was used to create the prediction models, and a second cohort of 721 patients from a different centre was used to validate the models, all of whom underwent TKA. Patient characteristics, BMI, OKS, and EQ-5D-3L were collected preoperatively and one year postoperatively. Generalized linear regression was used to formulate the prediction models. Results. There were significant correlations between the OKS and EQ-5D-3L preoperatively (r = 0.68; p < 0.001) and postoperatively (r = 0.77; p < 0.001) and for the change in the scores (r = 0.61; p < 0.001). Three different models (preoperative, postoperative, and change) were created. There were no significant differences between the actual and predicted mean EQ-5D-3L utilities at any timepoint or for change in the scores (p > 0.090) in the validation cohort. There was a significant correlation between the actual and predicted EQ-5D-3L utilities preoperatively (r = 0.63; p < 0.001) and postoperatively (r = 0.77; p < 0.001) and for the change in the scores (r = 0.56; p < 0.001). Bland-Altman plots demonstrated that a lower utility was overestimated, and higher utility was underestimated. The individual predicted EQ-5D-3L that was within ± 0.05 and ± 0.010 (minimal clinically important difference (MCID)) of the actual EQ-5D-3L varied between 13% to 35% and 26% to 64%, respectively, according to timepoint assessed and change in the scores, but was not significantly different between the modelling and validation cohorts (p ≥ 0.148). Conclusion. The OKS can be used to estimate EQ-5D-3L. Predicted individual patient utility error beyond the MCID varied from one-third to two-thirds depending on timepoint assessed, but the mean for a cohort did not differ and could be employed for this purpose. Cite this article: Bone Jt Open 2022;3(7):573–581


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 336 - 343
1 Apr 2024
Haertlé M Becker N Windhagen H Ahmad SS

Aims. Periacetabular osteotomy (PAO) is widely recognized as a demanding surgical procedure for acetabular reorientation. Reports about the learning curve have primarily focused on complication rates during the initial learning phase. Therefore, our aim was to assess the PAO learning curve from an analytical perspective by determining the number of PAOs required for the duration of surgery to plateau and the accuracy to improve. Methods. The study included 118 consecutive PAOs in 106 patients. Of these, 28 were male (23.7%) and 90 were female (76.3%). The primary endpoint was surgical time. Secondary outcome measures included radiological parameters. Cumulative summation analysis was used to determine changes in surgical duration. A multivariate linear regression model was used to identify independent factors influencing surgical time. Results. The learning curve in this series was 26 PAOs in a period of six months. After 26 PAO procedures, a significant drop in surgical time was observed and a plateau was also achieved. The mean duration of surgery during the learning curve was 103.8 minutes (SD 33.2), and 69.7 minutes (SD 18.6) thereafter (p < 0.001). Radiological correction of acetabular retroversion showed a significant improvement after having performed a total of 93 PAOs, including anteverting PAOs on 35 hips with a retroverted acetabular morphology (p = 0.005). Several factors were identified as independent variables influencing duration of surgery, including patient weight (β = 0.5 (95% confidence interval (CI) 0.2 to 0.7); p < 0.001), learning curve procedure phase of 26 procedures (β = 34.0 (95% CI 24.3 to 43.8); p < 0.001), and the degree of lateral correction expressed as the change in the lateral centre-edge angle (β = 0.7 (95% CI 0.001 to 1.3); p = 0.048). Conclusion. The learning curve for PAO surgery requires extensive surgical training at a high-volume centre, with a minimum of 50 PAOs per surgeon per year. This study defined a cut-off value of 26 PAO procedures, after which a significant drop in surgical duration occurred. Furthermore, it was observed that a retroverted morphology of the acetabulum required a greater number of procedures to acquire proficiency in consistently eliminating the crossover sign. These findings are relevant for fellows and fellowship programme directors in establishing the extent of training required to impart competence in PAO. Cite this article: Bone Joint J 2024;106-B(4):336–343


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1695 - 1701
1 Nov 2021
Currier JH Currier BH Abdel MP Berry DJ Titus AJ Van Citters DW

Aims. Wear of the polyethylene (PE) tibial insert of total knee arthroplasty (TKA) increases the risk of revision surgery with a significant cost burden on the healthcare system. This study quantifies wear performance of tibial inserts in a large and diverse series of retrieved TKAs to evaluate the effect of factors related to the patient, knee design, and bearing material on tibial insert wear performance. Methods. An institutional review board-approved retrieval archive was surveyed for modular PE tibial inserts over a range of in vivo duration (mean 58 months (0 to 290)). Five knee designs, totalling 1,585 devices, were studied. Insert wear was estimated from measured thickness change using a previously published method. Linear regression statistical analyses were used to test association of 12 patient and implant design variables with calculated wear rate. Results. Five patient-specific variables and seven implant-specific variables were evaluated for significant association with lower insert wear rate. Six were significant when controlling for other factors: greater patient age, female sex, shorter duration in vivo, polished tray, highly cross-linked PE (HXLPE), and constrained knee design. Conclusion. This study confirmed that knee wear rate increased with duration in vivo. Older patients and females had significantly lower wear rates. Polished modular tibial tray surfaces, HXLPE, and constrained TKA designs were device design factors associated with significantly reduced wear rate. Cite this article: Bone Joint J 2021;103-B(11):1695–1701


Bone & Joint Open
Vol. 3, Issue 4 | Pages 291 - 301
4 Apr 2022
Holleyman RJ Lyman S Bankes MJK Board TN Conroy JL McBryde CW Andrade AJ Malviya A Khanduja V

Aims. This study uses prospective registry data to compare early patient outcomes following arthroscopic repair or debridement of the acetabular labrum. Methods. Data on adult patients who underwent arthroscopic labral debridement or repair between 1 January 2012 and 31 July 2019 were extracted from the UK Non-Arthroplasty Hip Registry. Patients who underwent microfracture, osteophyte excision, or a concurrent extra-articular procedure were excluded. The EuroQol five-dimension (EQ-5D) and International Hip Outcome Tool 12 (iHOT-12) questionnaires were collected preoperatively and at six and 12 months post-operatively. Due to concerns over differential questionnaire non-response between the two groups, a combination of random sampling, propensity score matching, and pooled multivariable linear regression models were employed to compare iHOT-12 improvement. Results. A total of 2,025 labral debridements (55%) and 1,659 labral repairs (45%) were identified. Both groups saw significant (p < 0.001) EQ-5D and iHOT-12 gain compared to preoperative scores at 12 months (iHOT-12 improvement: labral repair = +28.7 (95% confidence interval (CI) 26.4 to 30.9), labral debridement = +24.7 (95% CI 22.5 to 27.0)), however there was no significant difference between procedures after multivariable modelling. Overall, 66% of cases achieved the minimum clinically important difference (MCID) and 48% achieved substantial clinical benefit at 12 months. Conclusion. Both labral procedures were successful in significantly improving early functional outcome following hip arthroscopy, regardless of age or sex. Labral repair was associated with superior outcomes in univariable analysis, however there was no significant superiority demonstrated in the multivariable model. Level of evidence: III. Cite this article: Bone Jt Open 2022;3(4):291–301


Bone & Joint Research
Vol. 10, Issue 11 | Pages 734 - 741
1 Nov 2021
Cheng B Wen Y Yang X Cheng S Liu L Chu X Ye J Liang C Yao Y Jia Y Zhang F

Aims. Despite the interest in the association of gut microbiota with bone health, limited population-based studies of gut microbiota and bone mineral density (BMD) have been made. Our aim is to explore the possible association between gut microbiota and BMD. Methods. A total of 3,321 independent loci of gut microbiota were used to calculate the individual polygenic risk score (PRS) for 114 gut microbiota-related traits. The individual genotype data were obtained from UK Biobank cohort. Linear regressions were then conducted to evaluate the possible association of gut microbiota with L1-L4 BMD (n = 4,070), total BMD (n = 4,056), and femur total BMD (n = 4,054), respectively. PLINK 2.0 was used to detect the single-nucleotide polymorphism (SNP) × gut microbiota interaction effect on the risks of L1-L4 BMD, total BMD, and femur total BMD, respectively. Results. We detected five, three, and seven candidate gut microbiota-related traits for L1-L4 BMD, total BMD, and femur BMD, respectively, such as genus Dialister (p = 0.004) for L1-L4 BMD, and genus Eisenbergiella (p = 0.046) for total BMD. We also detected two common gut microbiota-related traits shared by L1-L4 BMD, total BMD, and femur total BMD, including genus Escherichia Shigella and genus Lactococcus. Interaction analysis of BMD detected several genes that interacted with gut microbiota, such as phospholipase D1 (PLD1) and endomucin (EMCN) interacting with genus Dialister in total BMD, and COL12A1 and Discs Large MAGUK Scaffold Protein 2 (DLG2) interacting with genus Lactococcus in femur BMD. Conclusion. Our results suggest associations between gut microbiota and BMD, which will be helpful to further explore the regulation mechanism and intervention gut microbiota of BMD. Cite this article: Bone Joint Res 2021;10(11):734–741


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims. Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane. Methods. Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation. Results. Overall, 26/40 hips had a centre of rotation displaced posteriorly compared to the contralateral hip, increasing to 33/40 once corrected for sagittal tilt, with a mean posterior displacement of 7 mm. Linear regression analysis indicated that stem anteversion needed to be increased by 10.8° to recreate the head centre in the AP plane. Merely matching the native version would result in a 12 mm posterior displacement. Conclusion. This study demonstrates the significant incidence of posterior displacement of the head centre in uncemented hip arthroplasty. Effects of such displacement include a reduction in impingement free range of motion, potential alterations in muscle force vectors and lever arms, and impaired proprioception due to muscle fibre reorientation. Cite this article: Bone Joint Res 2022;11(3):180–188