Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1405 - 1413
1 Aug 2021
Ogura K Fujiwara T Morris CD Boland PJ Healey JH

Aims

Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model.

Methods

We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 724 - 731
1 Jun 2019
Bernthal NM Upfill-Brown A Burke ZDC Ishmael CR Hsiue P Hori K Hornicek F Eckardt JJ

Aims

Aseptic loosening is a major cause of failure in cemented endoprosthetic reconstructions. This paper presents the long-term outcomes of a custom-designed cross-pin fixation construct designed to minimize rotational stress and subsequent aseptic loosening in selected patients. The paper will also examine the long-term survivorship and modes of failure when using this technique.

Patients and Methods

A review of 658 consecutive, prospectively collected cemented endoprosthetic reconstructions for oncological diagnoses at a single centre between 1980 and 2017 was performed. A total of 51 patients were identified with 56 endoprosthetic implants with cross-pin fixation, 21 of which were implanted following primary resection of tumour. Locations included distal femoral (n = 36), proximal femoral (n = 7), intercalary (n = 6), proximal humeral (n = 3), proximal tibial (n = 3), and distal humeral (n = 1).


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 134 - 138
1 Jan 2017
Houdek MT Bayne CO Bishop AT Shin AY

Aims. Free vascularised fibular grafting has been used for the treatment of large bony defects for more than 40 years. However, there is little information about the risk factors for failure and whether newer locking techniques of fixation improve the rates of union. The purpose of this study was to compare the rates of union of free fibular grafts fixed with locking and traditional techniques, and to quantify the risk factors for nonunion and failure. Patients and Methods. A retrospective review involved 134 consecutive procedures over a period of 20 years. Of these, 25 were excluded leaving 109 patients in the study. There were 66 men and 43 women, with a mean age of 33 years (5 to 78). Most (62) were performed for oncological indications, and the most common site (52) was the lower limb. Rate of union was estimated using the Kaplan-Meier method and risk factors for nonunion were assessed using Cox regression. All patients were followed up for at least one year. Results. The rate of union was 82% at two years and 97% at five years. Union was achieved after the initial procedure in 76 patients (70%) at a mean of ten months (3 to 19), and overall union was achieved in 99 patients (91%). No surgical factor, including the use of locked fixation or supplementary corticocancellous bone grafts increased the rate of union. A history of smoking was significantly associated with a risk of nonunion. Discussion. Free vascularised fibular grafting is a successful form of treatment for large bony defects. These results suggest that the use of modern techniques of fixation does not affect the risk of nonunion when compared with traditional forms of fixation, and smoking increases the risk of nonunion following this procedure. Cite this article: Bone Joint J 2017;99-B:134–8


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 703 - 709
1 May 2016
Kim Y Kang HG Kim JH Kim S Lin PP Kim HS

Aims

The purpose of the study was to investigate whether closed intramedullary (IM) nailing with percutaneous cement augmentation is better than conventional closed nailing at relieving pain and suppressing tumours in patients with metastases of the femur and humerus.

Patients and Methods

A total of 43 patients (27 men, 16 women, mean age 63.7 years, standard deviation (sd) 12.2; 21 to 84) underwent closed IM nailing with cement augmentation for long bone metastases. A further 27 patients, who underwent conventional closed IM nailing, served as controls. Pain was assessed using a visual analogue scale (VAS) score pre-operatively (pre-operative VAS), one week post-operatively (immediate post-operative VAS), and at six weeks post-operatively (follow-up post-operative VAS). Progression of the tumour was evaluated in subgroups of patients using F-18-fludeoxyglucose (F-18-FDG) positron emission tomography (PET)/computed tomography (CT) and/or bone scintigraphy (BS), at a mean of 8.8 and 7.2 months post-operatively, respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1077 - 1083
1 Aug 2007
Tsuchiya H Morsy AF Matsubara H Watanabe K Abdel-Wanis ME Tomita K

We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated.

The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221).

The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°).

At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 142 - 145
1 Jan 2010
Spencer SJ Holt G Clarke JV Mohammed A Leach WJ Roberts JLB

The humerus is a common site for skeletal metastases in the adult. Surgical stabilisation of such lesions is often necessary to relieve pain and restore function. These procedures are essentially palliative and should therefore provide effective relief from pain for the remainder of the patient’s life without the need for further surgical intervention.

We report a retrospective analysis of 35 patients (37 nails) with symptomatic metastases in the shaft of the humerus which were treated by locked, antegrade nailing. There were 27 true fractures (73.0%) and ten painful deposits (27.0%). Relief from pain was excellent in four (11.4%), good in 29 (82.9%) and fair in two (5.7%) on discharge. Function was improved in all but one patient. One case of palsy of the radial nerve was noted. The mean postoperative survival was 7.1 months (0.2 to 45.5) which emphasises the poor prognosis in this group of patients. There were no failures of fixation and no case in which further surgery was required.

Antegrade intramedullary nailing is an effective means of stabilising the humerus for the palliative treatment of metastases. It relieves pain and restores function to the upper limb with low attendant morbidity.