Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
Bone & Joint Open
Vol. 5, Issue 11 | Pages 977 - 983
5 Nov 2024
Danielsen O Jensen CB Varnum C Jakobsen T Andersen MR Bieder MJ Overgaard S Jørgensen CC Kehlet H Gromov K Lindberg-Larsen M

Aims

Day-case success rates after primary total hip arthroplasty (THA), total knee arthroplasty (TKA), and medial unicompartmental knee arthroplasty (mUKA) may vary, and detailed data are needed on causes of not being discharged. The aim of this study was to analyze the association between surgical procedure type and successful day-case surgery, and to analyze causes of not being discharged on the day of surgery when eligible and scheduled for day-case THA, TKA, and mUKA.

Methods

A multicentre, prospective consecutive cohort study was carried out from September 2022 to August 2023. Patients were screened for day-case eligibility using well defined inclusion and exclusion criteria, and discharged when fulfilling predetermined discharge criteria. Day-case eligible patients were scheduled for surgery with intended start of surgery before 1.00 pm.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 960 - 969
1 Aug 2019
Odgaard A Laursen MB Gromov K Troelsen A Kristensen PW Schrøder H Madsen F Overgaard S

Aims

The aim of this study was to give estimates of the incidence of component incompatibility in hip and knee arthroplasty and to test the effect of an online, real-time compatibility check.

Materials and Methods

Intraoperative barcode registration of arthroplasty implants was introduced in Denmark in 2013. We developed a compatibility database and, from May 2017, real-time compatibility checking was implemented and became part of the registration. We defined four classes of component incompatibility: A-I, A-II, B-I, and B-II, depending on an assessment of the level of risk to the patient (A/B), and on whether incompatibility was knowingly accepted (I/II).


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 900 - 907
1 Nov 1997
McLaughlin JR Lee KR

We followed 138 patients (145 hips) who had had uncemented total hip arthroplasty using the Taperloc femoral component for a mean of ten years (8 to 12.5). No patient was lost to follow-up; 31 (31 hips) died before the minimum time of eight years for inclusion in the study, and 30 of these still had their femoral component in place. One well-fixed prosthesis had been exchanged at the time of acetabular revision. Of the remaining 114 hips, one femoral component required revision for aseptic loosening and one for sepsis. Three other well-fixed femoral components were removed during acetabular revision. Complete clinical and radiological follow-up was obtained in the 109 hips which had not had revision. Clinically, 94 (87%) were rated good or excellent, eight (7%) fair and seven (6%) poor. The average Harris hip score increased from 48 before operation to 88 at the time of the last follow-up. Radiologically, 103 hips (94%) had fixation by bone ingrowth, three (3%) showed stable fibrous ingrowth and three (3%) were unstable. Osteolysis of the femoral cortex was seen in seven hips (6%), with major lysis in only one. At a mean follow-up of ten years, the results of the Taperloc femoral component are comparable with those of modern techniques of cementing in primary total hip arthroplasty


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1512 - 1518
1 Nov 2015
Courtney PM Melnic CM Gutsche J Hume EL Lee G

Older patients with multiple medical co-morbidities are increasingly being offered and undergoing total joint arthroplasty (TJA). These patients are more likely to require intensive care support, following surgery. We prospectively evaluated the need for intensive care admission and intervention in a consecutive series of 738 patients undergoing elective hip and knee arthroplasty procedures. The mean age was 60.6 years (18 to 91; 440 women, 298 men. Risk factors, correlating with the need for critical care intervention, according to published guidelines, were analysed to identify high-risk patients who would benefit from post-operative critical care monitoring. A total of 50 patients (6.7%) in our series required critical care level interventions during their hospital stay. Six independent multivariate clinical predictors were identified (p < 0.001) including a history of congestive heart failure (odds ratio (OR) 24.26, 95% confidence interval (CI) 9.51 to 61.91), estimated blood loss >  1000 mL (OR 17.36, 95% CI 5.36 to 56.19), chronic obstructive pulmonary disease (13.90, 95% CI 4.78 to 40.36), intra-operative use of vasopressors (OR 8.10, 95% CI 3.23 to 20.27), revision hip arthroplasty (OR 2.71, 95% CI 1.04 to 7.04) and body mass index > 35 kg/m2 (OR 2.70, 95% CI 123 to 5.94). The model was then validated against an independent, previously published data set of 1594 consecutive patients. The use of this risk stratification model can be helpful in predicting which high-risk patients would benefit from a higher level of monitoring and care after elective TJA and aid hospitals in allocating precious critical care resources.

Cite this article: Bone Joint J 2015;97-B:1512–18.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 928 - 935
1 Jul 2014
Matharu GS McBryde CW Robb CA Pynsent PB

The Oxford hip and knee scores (OHS and OKS) are validated patient-reported outcome measures used in patients undergoing total hip replacement (THR), hip resurfacing (HR), total knee replacement (TKR) and unicompartmental knee replacement (UKR). We analysed the absolute OHS and OKS and change in scores following THR, HR, TKR, and UKR performed at one specialist centre. All patients undergoing and completing at least one Oxford score were eligible for inclusion in the study which included 27 950 OHS and 19 750 OKS in 13 682 patients. Data were analysed using non-linear quantile regression. The median absolute Oxford scores for THR, HR, TKR and UKR were pre-operative 68.8% (15.0/48), 58.3% (20.0/48), 66.7% (16.0/48), 60.4% (19.0/48) respectively: and post-operative asymptote was 14.6% (41.0/48), 5.8% (45.2/48), 31.2% (33.0/48), 29.2% (34.0/48). The median asymptotic change from the pre-operative score for THR, HR, TKR and UKR were 47.9% (23.0/48), 47.9% (23.0/48), 33.3% (16.0/48) and 32.4% (15.5/48), respectively. The median time at which no further appreciable change in score was achieved post-operatively was 0.7 years for THR, 1.1 years for HR, 0.9 years for TKR and 1.1 years for UKR.

The curves produced from this analysis could be used to educate patients, and to audit the performance of a surgeon and an institution. The time to achieve a stable improvement in outcome varied between different types of joint replacement, which may have implications for the timing of post-operative review.

Cite this article: Bone Joint J 2014; 96-B:928–35.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 263 - 269
1 Feb 2014
Batta V Coathup MJ Parratt MT Pollock RC Aston WJ Cannon SR Skinner JA Briggs TW Blunn GW

We reviewed the outcome of 69 uncemented, custom-made, distal femoral endoprosthetic replacements performed in 69 patients between 1994 and 2006. There were 31 women and 38 men with a mean age at implantation of 16.5 years (5 to 37). All procedures were performed for primary malignant bone tumours of the distal femur. At a mean follow-up of 124.2 months (4 to 212), 53 patients were alive, with one patient lost to follow-up. All nine implants (13.0%) were revised due to aseptic loosening at a mean of 52 months (8 to 91); three implants (4.3%) were revised due to fracture of the shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic fracture. Bone remodelling associated with periosteal cortical thinning adjacent to the uncemented intramedullary stem was seen in 24 patients but this did not predispose to failure. All aseptically loose implants in this series were diagnosed to be loose within the first five years.

The results from this study suggest that custom-made uncemented distal femur replacements have a higher rate of aseptic loosening compared to published results for this design when used with cemented fixation. Loosening of uncemented replacements occurs early indicating that initial fixation of the implant is crucial.

Cite this article: Bone Joint J 2014;96-B:263–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1120 - 1125
1 Aug 2012
Alazzawi S Bardakos NV Hadfield SG Butt U Beer ZH Field RE

Using general practitioner records and hospital notes and through direct telephone conversation with patients, we investigated the accuracy of nine patient-reported complications gathered from a self-completed questionnaire after elective joint replacement surgery of the hip and knee. A total of 402 post-discharge complications were reported after 8546 elective operations that were undertaken within a three-year period. These were reported by 136 men and 240 women with a mean age of 71.8 years (34 to 93). A total of 319 reported complications (79.4%; 95% confidence interval 75.4 to 83.3) were confirmed to be correct. High rates of correct reporting were demonstrated for infection (94.5%) and the need for further surgery (100%), whereas the rates of reporting deep-vein thrombosis (DVT), pulmonary embolism, myocardial infarction and stroke were lower (75% to 84.2%). Dislocation, peri-prosthetic fractures and nerve palsy had modest rates of correct reporting (36% to 57.1%). More patients who had knee surgery delivered incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013).

Despite these variations, it appears that post-operative complications may form part of a larger patient-reported outcome programme after elective joint replacement surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 94 - 99
1 Jan 2007
Bottner F Wegner A Winkelmann W Becker K Erren M Götze C

This prospective study evaluates the role of new laboratory markers in the diagnosis of deep implant infection in 78 patients (41 men and 37 women) with a revision total knee or hip replacement.

The mean age at the time of operation was 64.0 years (19 to 90). Intra-operative cultures showed that 21 patients had a septic and 57 an aseptic total joint replacement. The white blood cell count, the erythrocyte sedimentation rate and levels of C-reactive protein, interleukin-6, procalcitonin and tumour necrosis factor (TNF)-α were measured in blood samples before operation. The diagnostic cut-off values were determined by Received Operating Characteristic curve analysis.

C-reactive protein (> 3.2 md/dl) and interleukin-6 (> 12 pg/ml) have the highest sensitivity (0.95). Interleukin-6 is less specific than C-reactive protein (0.87 vs 0.96). Combining C-reactive protein and interleukin-6 identifies all patients with deep infection of the implant. Procalcitonin (> 0.3 ng/ml) and TNF-α (> 40 ng/ml) are very specific (0.98 vs 0.94) but have a low sensitivity (0.33 vs 0.43).

The combination of C-reactive protein and interleukin-6 measurement provide excellent screening tests for infection of a deep implant. A highly specific marker such as procalcitonin and pre-operative aspiration of the joint might be useful in identifying patients with true positive C-reactive protein and/or interleukin-6 levels.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 213 - 217
1 Feb 2005
Mundy GM Birtwistle SJ Power RA

We randomised 120 patients who were undergoing either primary total hip or knee arthroplasty to receive either ferrous sulphate or a placebo for three weeks after surgery. The level of haemoglobin and absolute reticulocyte count were measured at one and five days, and three and six weeks after operation. Ninety-nine patients (ferrous sulphate 50, placebo 49) completed the study. The two groups differed only in the treatment administered.

Recovery of level of haemoglobin was similar at five days and three weeks and returned to 85% of the pre-operative level, irrespective of the treatment group. A small, albeit greater recovery in the level of haemoglobin was identified at six weeks in the ferrous sulphate group in both men (ferrous sulphate 5%, placebo 1.5%) and women (ferrous sulphate 6%, placebo 3%). The clinical significance of this is questionable and may be outweighed by the high incidence of reported side effects of oral iron and the cost of the medication. Administration of iron supplements after elective total hip or total knee arthroplasty does not appear to be worthwhile.