Advertisement for orthosearch.org.uk
Results 1 - 20 of 48
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1184 - 1188
1 Nov 2023
Jennison T Ukoumunne OC Lamb S Goldberg AJ Sharpe I

Aims. The number of revision total ankle arthroplasties (TAAs) which are undertaken is increasing. Few studies have reported the survival after this procedure. The primary aim of this study was to analyze the survival of revision ankle arthroplasties using large datasets. Secondary aims were to summarize the demographics of the patients, the indications for revision TAA, further operations, and predictors of survival. Methods. The study combined data from the National Joint Registry and NHS Digital to report the survival of revision TAA. We have previously reported the failure rates and risk factors for failure after TAA, and the outcome of fusion after a failed TAA, using the same methodology. Survival was assessed using life tables and Kaplan Meier graphs. Cox proportional hazards regression models were fitted to compare failure rates. Results. A total of 228 patients underwent revision TAA. The mean follow-up was 2.6 years (SD 2.0). The mean time between the initial procedure and revision was 2.3 years (SD 1.8). The most commonly used implant was the Inbone which was used in 81 patients. A total of 29 (12.7%) failed; nine (3.9%) patients underwent a further revision, 19 (8.3%) underwent a fusion, and one (0.4%) had an amputation. The rate of survival was 95.4% (95% confidence interval (CI) 91.6 to 97.5) at one year, 87.7% (95% CI 81.9 to 91.7; n = 124) at three years and 77.5% (95% CI 66.9 to 85.0; n = 57) at five years. Revision-specific implants had a better survival than when primary implants were used at revision. A total of 50 patients (21.9%) had further surgery; 19 (8.3%) underwent reoperation in the first 12 months. Cox regression models were prepared. In crude analysis the only significant risk factors for failure were the use of cement (hazard ratio (HR) 3.02 (95% CI 1.13 to 8.09)) and the time since the primary procedure (HR 0.67 (95% CI 0.47 to 0.97)). No risk factors for failure were identified in multivariable Cox regression modelling. Conclusion. Revision TAAs have good medium term survival and low rates of further surgery. New modular revision implants appear to have improved the survival compared with the use of traditional primary implants at revision. Cite this article: Bone Joint J 2023;105-B(11):1184–1188


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 46 - 52
1 Jan 2024
Hintermann B Peterhans U Susdorf R Horn Lang T Ruiz R Kvarda P

Aims. Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined. Methods. This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up. Results. The mean duration from initial revision TAA to last follow-up was 15.0 years (SD 3.0; 11.2 to 20.5). The cumulative survival rates of the revised ankles were 81% (95% confidence interval (CI) 74% to 88%), 74% (65% to 82%), and 70% (61% to 79%) at five, ten, and 15 years, respectively. Comorbidities prior to primary TAA, aseptic loosening, instability, or grafting of cysts were found to be the most common risk factors for secondary revision. The median value for preoperative pain, as assessed using the visual analogue scale, declined from 6 (interquartile range (IQR) 5 to 8) to 2 (IQR 0 to 5) (p < 0.001) and the mean American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from 43 (SD 17) preoperatively to 70 (SD 20) (p < 0.001) at last follow-up. Conclusion. Revision TAA offers acceptable survival rates after 15 years; it therefore offers a valuable option for treatment of implant failure in carefully selected cases. Although patient-reported outcomes improve substantially, the degree of improvement reported following primary TAA is not achieved. Cite this article: Bone Joint J 2024;106-B(1):46–52


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 301 - 306
1 Mar 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ

Aims. Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. Methods. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Results. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%), five-year survival in 2,725 patients of 90.2% (95% CI 89.2% to 91.1%), and ten-year survival in 199 patients of 86.2% (95% CI 84.6% to 87.6%). The five-year survival for fixed-bearing implants was 94.3% (95% CI 91.3% to 96.3%) compared to 89.4% (95% CI 88.3% to 90.4%) for mobile-bearing implants. A Cox regression model for all implants with over 100 implantations using the implant with the best survivorship (Infinity) as the reference, only the STAR (hazard ratio (HR) 1.60 (95% CI 0.87 to 2.96)) and INBONE (HR 0.38 (95% CI 0.05 to 2.84)) did not demonstrate worse survival at three and five years. Conclusion. Ankle arthroplasties in the UK have a five-year survival rate of 90.2%, which is lower than recorded on the NJR, because we have shown that approximately one-third of ankle arthroplasty failures are not reported to the NJR. There are statistically significant differences in survival between different implants. Fixed-bearing implants appear to demonstrate higher survivorship than mobile-bearing implants. Cite this article: Bone Joint J 2023;105-B(3):301–306


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 945 - 951
1 Jul 2016
Clement ND MacDonald D Dall GF Ahmed I Duckworth AD Shalaby HS McKinley J

Aims. To examine the mid-term outcome and cost utility of the BioPro metallic hemiarthroplasty for the treatment of hallux rigidius. Patients and Methods. We reviewed 97 consecutive BioPro metallic hemiarthroplasties performed in 80 patients for end-stage hallux rigidus, with a minimum follow-up of five years. There were 19 men and 61 women; their mean age was 55 years (22 to 74). No patient was lost to follow-up. Results. A total of 12 patients (15 first metatarso-phalangeal joints (MTPJs)) required a revision; one for infection, two for osteolysis and 12 for pain. The all cause rate of survival at five years was 85.6% (95% confidence interval (CI) 83.5 to 87.9). Younger age was a significant predictor of revision (odds ratio 1.09, 95% CI 1.02 to 1.17, p = 0.014) on excluding infection and adjusting for confounding variables (Cox regression). Significant improvements were demonstrated at five years in the Manchester Oxford Foot Questionnaire (13.9, 95% CI 10.5 to 17.2) and in the physical component of the Short Form-12 score (6.5, 95% CI 4.1 to 8.9). The overall rate of satisfaction was 75%. The cost per quality adjusted life year at five years, accounting for a 14% rate of revision was between £4431 and £6361 depending on the complexity and morbidity of the patient. Conclusion. The BioPro hemiarthroplasty offers good short to mid-term functional outcome and is a cost effective intervention. The relatively high revision rate is associated with younger age and perhaps the use of this implant should be limited to older patients. Cite this article: Bone Joint J 2016;98-B:945–51


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 220 - 226
1 Feb 2020
Clough TM Ring J

Aims

Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR.

Methods

We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1094 - 1098
1 Oct 2023
Jennison T Ukoumunne OC Lamb S Sharpe I Goldberg AJ

Aims. When a total ankle arthroplasty (TAA) fails, it can be converted to a fusion or a revision arthroplasty. Despite the increasing numbers of TAAs being undertaken, there is little information in the literature about the management of patients undergoing fusion following a failed TAA. The primary aim of this study was to analyze the survival of fusions following a failed TAA using a large dataset from the National Joint Registry (NJR). Methods. A data linkage study combined NJR and NHS Digital data. Failure of a TAA was defined as a fusion, revision to a further TAA, or amputation. Life tables and Kaplan-Meier graphs were used to record survival. Cox proportional hazards regression models were fitted to compare the rates of failure. Results. A total of 131 patients underwent fusion as a salvage procedure following TAA. Their mean age was 65.7 years (SD 10.6) and 73 (55.7%) were male. The mean follow-up was 47.5 months (SD 27.2). The mean time between TAA and fusion was 5.3 years (SD 2.7). Overall, 32 (24.4%) underwent reoperations other than revision and 29 (22.1%) failed. Of these 24 (18.3%) underwent revision of the fusion and five (3.8%) had a below-knee amputation. No patients underwent conversion to a further TAA. Failure usually occurred in the first three postoperative years with one-year survival of fusion being 96.0% (95% confidence interval (CI) 90.7 to 98.3) and three-year survival in 69 patients being 77.5% (95% CI 68.3 to 84.4). Conclusion. Salvage fusion after a failed TAA shows moderate rates of failure and reoperations. Nearly 25% of patients required revision within three years. This study is an extension of studies using the same methodology reporting the failure rates and risk factors for failure, which have recently been published, and also one reporting the outcome of revision TAA for a failed primary TAA, using the same methodology, which will shortly be published. Cite this article: Bone Joint J 2023;105-B(10):1094–1098


Bone & Joint Open
Vol. 5, Issue 9 | Pages 799 - 805
24 Sep 2024
Fletcher WR Collins T Fox A Pillai A

Aims. The Cartiva synthetic cartilage implant (SCI) entered mainstream use in the management of first metatarsophalangeal joint (MTPJ) arthritis following the positive results of large trials in 2016. Limited information is available on the longer-term outcomes of this implant within the literature, particularly when independent from the originator. This single-centre cohort study investigates the efficacy of the Cartiva SCI at up to five years. Methods. First MTPJ arthritis was radiologically graded according to the Hattrup and Johnson (HJ) classification. Preoperative and sequential postoperative patient-reported outcome measures (PROMs) were evaluated using the Manchester-Oxford Foot Questionnaire (MOXFQ), and the activities of daily living (ADL) sub-section of the Foot and Ankle Ability Measure (FAAM). Results. Patients were followed up for a mean of 66 months (SD 7.1). Of an initial 66 cases, 16 did not return PROM questionnaires. A total of six failures were noted, with survival of 82%. Overall, significant improvement in both objective scores (MOXFQ and FAAM ADL) was maintained versus preoperatively: 18.2 versus 58.0 (p > 0.001) and 86.2 versus 41.1 (p > 0.001), respectively. The improvement was noted to be less pronounced in males. Subjective scores had deteriorated since early follow-up, with an interval decrease in patient satisfaction from 89% to 68%. Furthermore, a subset of cases demonstrated clinically important interval deterioration in objective scores. However, no specific patient factors were found to be associated with outcomes following analysis. Conclusion. This study represents the longest-term independent follow-up in the literature. It shows reassuring mid-term efficacy of the Cartiva SCI with better-than-expected survival. However, deterioration in scores for a subset of patients and lower satisfaction may predict ongoing failure in this group of patients. Additionally, males were noted to have a lower degree of improvement in scores than females. As such, ongoing observation of the SCI to assess durability and survivability, and identify predictive factors, is key to improving patient selection. Cite this article: Bone Jt Open 2024;5(9):799–805


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1099 - 1107
1 Oct 2023
Henry JK Shaffrey I Wishman M Palma Munita J Zhu J Cody E Ellis S Deland J Demetracopoulos C

Aims. The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. Methods. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes. Results. There were 168 patients (171 ankles) included with a mean follow-up of 2.81 years (2 to 4.6) and mean age of 63.0 years (SD 9.4). Of the ten ankles with implant failure (5.8%), six had loosening of the tibial component. In the remaining four failed implants, one was due to periprosthetic joint infection (PJI), one was due to loosening of the talar component, and two were due to loosening of both the tibial and talar components. Seven patients underwent reoperation: irrigation and debridement for superficial infection (n = 4); bone grafting for cysts (n = 2); and open reduction internal fixation (n = 1). Asymptomatic peri-implant lucency/subsidence occurred in 20.1% of ankles, with the majority involving the tibial component (n = 25). There were statistically significant improvements in PROMs in all domains. Conclusion. Short-term results of this implant demonstrate early survival comparable to the reported survivorship of similar low-profile, non-stemmed implants. Radiological lucency occurred more commonly at the tibial component, and revisions occurred primarily due to loosening of the tibial component. Further research is needed to evaluate longer-term survivorship. Cite this article: Bone Joint J 2023;105-B(10):1099–1107


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 696 - 703
1 Apr 2021
Clough TM Ring J

Aims. We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Methods. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year. Results. Eight patients (ten ankles) died during follow-up, but none required revision. Of the surviving 106 patients (108 ankles: rheumatoid arthritis (RA), n = 15; osteoarthritis (OA), n = 93), 38 were women and 68 were men, with a mean age of 68.2 years (48 to 86) at the time of surgery. Mean follow-up was 5.1 years (2.1 to 9.0). A total of ten implants failed (8.5%), thus requiring revision. The implant survival at seven years, using revision as an endpoint, was 88.2% (95% CI 100% to 72.9%). There was a mean improvement in Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ) from 85.0 to 32.8 and visual analogue scale (VAS) scores from 7.0 to 3.2, and overall satisfaction was 89%. The three commonest complications were malleolar fracture (14.4%, n = 17), wound healing (13.6%, n = 16), and superficial infection (12.7%, n = 15). The commonest reason for revision was aseptic loosening. No patients in our study were revised for deep infection. Conclusion. Our results show that Zenith survival rates are comparable with those in the literature for other implants and in the National Joint Registry (NJR). Overall patient satisfaction was high as were functional outcomes. However, the data highlight potential complications associated with this surgery. The authors believe that these figures support ankle arthroplasty as an option in the treatment of ankle arthritis. Cite this article: Bone Joint J 2021;103-B(4):696–703


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 472 - 478
1 Apr 2022
Maccario C Paoli T Romano F D’Ambrosi R Indino C Federico UG

Aims. This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years. Methods. We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up. Results. A total of 86 patients were evaluated at a mean follow-up of 65.4 months (60 to 90). At five-year follow-up, statistically significant improvements (p < 0.001) were found in the mean American Orthopaedic Foot & Ankle Society Ankle Hindfoot Score (from 33.8 (SD 14.3) to 86.1 (SD 8.8)), visual analogue scale for pain (from 8.5 (SD 1.7) to 1.5 (SD 1.2)), Short Form-12 Physical and Mental Component Scores (from 29.9 (SD 6.7) and 43.3 (SD 8.6) to 47.3 (SD 7.5) and 52.2 (SD 8.0), respectively), and mean ankle dorsiflexion and plantarflexion (from 6.2° (SD 5.5°) and 9.6° (SD 5.8°) to 23.9° (SD 7.7°) and 16.9° (SD 7.2°), respectively). Radiologically, the implants maintained neutral alignment without subsidence. Tibial or talar radiolucency was found in eight patients, but none of these patients was symptomatic. At five-year follow up, 97.7% of implants (95% confidence interval 91.2 to 99.4) were free from revision or removal with 84 implants at risk. We recorded two cases (2.3%) of failure for septic loosening. Conclusion. Transfibular TAA is safe and effective with a high survival rate at mid-term follow-up and satisfactory clinical and radiological results. Further studies are required to determine the long-term performance of these implants. Cite this article: Bone Joint J 2022;104-B(4):472–478


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 47 - 54
1 Jan 2019
Clough T Bodo K Majeed H Davenport J Karski M

Aims. We report the long-term clinical and radiological outcomes of a consecutive series of 200 total ankle arthroplasties (TAAs, 184 patients) at a single centre using the Scandinavian Total Ankle Replacement (STAR) implants. Patients and Methods. Between November 1993 and February 2000, 200 consecutive STAR prostheses were implanted in 184 patients by a single surgeon. Demographic and clinical data were collected prospectively and the last available status was recorded for further survival analysis. All surviving patients underwent regular clinical and radiological review. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scoring system. The principal endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan–Meier survival curves were generated with 95% confidence intervals and the rate of failure calculated for each year. Results. A total of 84 patients (87 ankles) were alive by the end of this study. Of the surviving 84 patients (87 ankles; rheumatoid arthritis (RA), n = 40; OA, n = 47), 45 were women and 39 were men, with a mean age of 54 years (18 to 72 years) at the time of surgery. A total of 32 implants failed (16%), requiring revision surgery. The mean time to revision was 80 months (2 to 257). The implant survival at 15.8 years, using revision as an endpoint, was 76.16% (95% confidence interval (CI) 64.41 to 87.91). We found a steady but low decrease in survival over the study period. The mean AOFAS score improved from 28 (10 to 52) preoperatively to 61 (20 to 90) at long-term follow-up. Conclusion. STAR prostheses in the United Kingdom have now been largely superseded by newer design TAAs, potentially with improved characteristics and surgical techniques. The long-term survivorship for the STAR prosthesis can provide a benchmark for these later designs of ankle arthroplasty


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 475 - 481
1 May 2024
Lee M Lee G Lee K

Aims

The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan.

Methods

We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 985 - 992
1 Sep 2023
Arshad Z Haq II Bhatia M

Aims

This scoping review aims to identify patient-related factors associated with a poorer outcome following total ankle arthroplasty (TAA).

Methods

A scoping review was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A computer-based literature search was performed in PubMed, Embase, Cochrane trials, and Web of Science. Two reviewers independently performed title/abstract and full-text screening according to predetermined selection criteria. English-language original research studies reporting patient-related factors associated with a poorer outcome following TAA were included. Outcomes were defined as patient-reported outcome measures (PROMs), perioperative complications, and failure.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 895 - 904
1 Aug 2023
Smith TO Dainty J Loveday DT Toms A Goldberg AJ Watts L Pennington MW Dawson J van der Meulen J MacGregor AJ

Aims

The aim of this study was to capture 12-month outcomes from a representative multicentre cohort of patients undergoing total ankle arthroplasty (TAA), describe the pattern of patient-reported outcome measures (PROMs) at 12 months, and identify predictors of these outcome measures.

Methods

Patients listed for a primary TAA at 19 NHS hospitals between February 2016 and October 2017 were eligible. PROMs data were collected preoperatively and at six and 12 months including: Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ (foot and ankle)) and the EuroQol five-dimension five-level questionnaire (EQ-5D-5L). Radiological pre- and postoperative data included Kellgren-Lawrence score and implant position measurement. This was supplemented by data from the National Joint Registry through record linkage to determine: American Society of Anesthesiologists (ASA) grade at index procedure; indication for surgery, index ankle previous fracture; tibial hind foot alignment; additional surgery at the time of TAA; and implant type. Multivariate regression models assessed outcomes, and the relationship between MOXFQ and EQ-5D-5L outcomes, with patient characteristics.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1611 - 1618
1 Oct 2021
Kavarthapu V Budair B

Aims

In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method.

Methods

We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1270 - 1276
1 Jul 2021
Townshend DN Bing AJF Clough TM Sharpe IT Goldberg A

Aims

This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes.

Methods

Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 958 - 962
1 Jul 2010
Wood PLR Karski MT Watmough P

We describe the early results of a prospective study of 100 total ankle replacements (96 patients) at a single centre using the Mobility Total Ankle Replacement. At final review, six patients had died and five ankles (5%) had been revised, two by fusion and three by exchange of components. All remaining patients were reviewed at a minimum of three years. The mean follow-up was 43 months (4 to 63). The three-year survival was 97% (95% confidence interval (CI) 91 to 99). The four-year survival was 93.6% (95% CI 84.7 to 97.4). The portion of bony interface that was visible on plain radiograph was divided into 15 zones and a radiolucent line or osteolytic cavity was seen in one zone in 14 ankles. It was not seen in more than one zone. In five ankles it was > 10 mm in width. This study suggests that the early outcome of ankle replacement is comparable to that of other total joint replacements


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 61 - 65
1 Jan 2010
Morgan SS Brooke B Harris NJ

We present the outcomes in 38 consecutive patients who had total ankle replacement using the Ankle Evolution System with a minimum follow-up of four years. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score and regular standardised anteroposterior and lateral weight-bearing radiographs were obtained. Patient satisfaction and complications were recorded and the survival of the implants was demonstrated by the Kaplan-Meier method. The mean follow-up was for 57.8 months (48 to 80). The cumulative survival rate at six years was 94.7% (95% confidence interval 80.3 to 98.7). The mean total AOFAS score was 88.1 (53 to 100). The mean score for pain was 35.8 (20 to 40). Ten patients presented with edge-loading of whom nine had corrective surgery. Two ankles were revised, one to an arthrodesis and the other to replace the tibial component. Nine patients showed radiological evidence of osteolysis. They had minimal non-progressive symptoms and further surgery was not undertaken. Nevertheless, the concerns about osteolysis led to the implant being withdrawn by the manufacturer. The medium-term results of the ankle evolution system ankle replacement are satisfactory with high patient satisfaction, but the rate of osteolysis is of some concern. The long-term benefit of this procedure has yet to be determined


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 605 - 609
1 May 2008
Wood PLR Prem H Sutton C

We describe the medium-term results of a prospective study of 200 total ankle replacements at a single-centre using the Scandinavian Total Ankle Replacement. A total of 24 ankles (12%) have been revised, 20 by fusion and four by further replacement and 27 patients (33 ankles) have died. All the surviving patients were seen at a minimum of five years after operation. The five-year survival was 93.3% (95% confidence interval (CI) 89.8 to 96.8) and the ten-year survival 80.3% (95% CI 71.0 to 89.6). Anterior subluxation of the talus, often seen on the lateral radiograph in osteoarthritic ankles, was corrected and, in most instances, the anatomical alignment was restored by total ankle replacement. The orientation of the tibial component, as seen on the lateral radiograph, also affects the position of the talus and if not correct can hold the talus in an abnormal anterior position. Subtalar arthritis may continue to progress after total ankle replacement. Our results are similar to those published previously


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 925 - 932
1 Jul 2020
Gaugler M Krähenbühl N Barg A Ruiz R Horn-Lang T Susdorf R Dutilh G Hintermann B

Aims

To assess the effect of age on clinical outcome and revision rates in patients who underwent total ankle arthroplasty (TAA) for end-stage ankle osteoarthritis (OA).

Methods

A consecutive series of 811 ankles (789 patients) that underwent TAA between May 2003 and December 2013 were enrolled. The influence of age on clinical outcome, including the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, and pain according to the visual analogue scale (VAS) was assessed. In addition, the risk for revision surgery that includes soft tissue procedures, periarticular arthrodeses/osteotomies, ankle joint debridement, and/or inlay exchange (defined as minor revision), as well as the risk for revision surgery necessitating the exchange of any of the metallic components or removal of implant followed by ankle/hindfoot fusion (defined as major revision) was calculated.