Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
Bone & Joint Open
Vol. 5, Issue 4 | Pages 317 - 323
18 Apr 2024
Zhu X Hu J Lin J Song G Xu H Lu J Tang Q Wang J

Aims. The aim of this study was to investigate the safety and efficacy of 3D-printed modular prostheses in patients who underwent joint-sparing limb salvage surgery (JSLSS) for malignant femoral diaphyseal bone tumours. Methods. We retrospectively reviewed 17 patients (13 males and four females) with femoral diaphyseal tumours who underwent JSLSS in our hospital. Results. In all, 17 patients with locally aggressive bone tumours (Enneking stage IIB) located in the femoral shaft underwent JSLSS and reconstruction with 3D-printed modular prostheses between January 2020 and June 2022. The median surgical time was 153 minutes (interquartile range (IQR) 117 to 248), and the median estimated blood loss was 200ml (IQR 125 to 400). Osteosarcoma was the most common pathological type (n = 12; 70.6%). The mean osteotomy length was 197.53 mm (SD 12.34), and the median follow-up was 25 months (IQR 19 to 38). Two patients experienced local recurrence and three developed distant metastases. Postoperative complications included wound infection in one patient and screw loosening in another, both of which were treated successfully with revision surgery. The median Musculoskeletal Tumor Society score at the final follow-up was 28 (IQR 27 to 28). Conclusion. The 3D-printed modular prosthesis is a reliable and feasible reconstruction option for patients with malignant femoral diaphyseal tumours. It helps to improve the limb salvage rate, restore limb function, and achieve better short-term effectiveness. Cite this article: Bone Jt Open 2024;5(4):317–323


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 979 - 986
1 Jul 2017
Schwab JH Janssen SJ Paulino Pereira NR Chen YLE Wain JC DeLaney TF Hornicek FJ

Aims

The aim of the study was to compare measures of the quality of life (QOL) after resection of a chordoma of the mobile spine with the national averages in the United States and to assess which factors influenced the QOL, symptoms of anxiety and depression, and coping with pain post-operatively in these patients.

Patients and Methods

A total of 48 consecutive patients who underwent resection of a primary or recurrent chordoma of the mobile spine between 2000 and 2015 were included. A total of 34 patients completed a survey at least 12 months post-operatively. The primary outcome was the EuroQol-5 Dimensions (EQ-5D-3L) questionnaire. Secondary outcomes were the Patient-Reported Outcome Measurement Information System (PROMIS) anxiety, depression and pain interference questionnaires. Data which were recorded included the indication for surgery, the region of the tumour, the number of levels resected, the status of the surgical margins, re-operations, complications, neurological deficit, length of stay in hospital and rate of re-admission.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1542 - 1547
1 Nov 2016
Sampath Kumar V Tyrrell PNM Singh J Gregory J Cribb GL Cool P

Aims

The purpose of this study was to determine if clinical and radiological surveillance of cartilage tumours with low biological activity is appropriate.

Patients and Methods

A total of 98 patients with an intramedullary cartilage neoplasm in a long bone met our inclusion criteria and were included in the study. These patients had undergone a total of 384 scans. Patients with radiological follow-up of more than three years (46 patients) were divided into two groups: an active group (11 patients) and a latent group (35 patients).


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 127 - 131
1 Jan 2014
Wijsbek AE Vazquez-Garcia BL Grimer RJ Carter SR Abudu AA Tillman RM Jeys L

The purpose of this study was to assess whether the use of a joint-sparing technique such as curettage and grafting was successful in eradicating giant cell tumours of the proximal femur, or whether an alternative strategy was more appropriate.

Between 1974 and 2012, 24 patients with a giant cell tumour of the proximal femur were treated primarily at our hospital. Treatment was either joint sparing or joint replacing. Joint-sparing treatment was undertaken in ten patients by curettage with or without adjunctive bone graft. Joint replacement was by total hip replacement in nine patients and endoprosthetic replacement in five. All 11 patients who presented with a pathological fracture were treated by replacement.

Local recurrence occurred in five patients (21%): two were treated by hip replacement, three by curettage and none with an endoprosthesis. Of the ten patients treated initially by curettage, six had a successful outcome without local recurrence and required no further surgery. Three eventually needed a hip replacement for local recurrence and one an endoprosthetic replacement for mechanical failure. Thus 18 patients had the affected joint replaced and only six (25%) retained their native joint. Overall, 60% of patients without a pathological fracture who were treated with curettage had a successful outcome.

Cite this article: Bone Joint J 2014;96-B:127–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 648 - 651
1 May 2008
George B Abudu A Grimer RJ Carter SR Tillman RM

We report our experience of treating 17 patients with benign lesions of the proximal femur with non-vascularised, autologous fibular strut grafts, without osteosynthesis. The mean age of the patients at presentation was 16.5 years (5 to 33) and they were followed up for a mean of 2.9 years (0.4 to 19.5). Histological diagnoses included simple bone cyst, fibrous dysplasia, aneurysmal bone cysts and giant cell tumour. Local recurrence occurred in two patients (11.7%) and superficial wound infection, chronic hip pain and deep venous thrombosis occurred in three. Pathological fracture did not occur in any patient following the procedure.

We conclude that non-vascularised fibular strut grafts are a safe and satisfactory method of treating benign lesions of the proximal femur.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 521 - 526
1 Apr 2007
Myers GJC Abudu AT Carter SR Tillman RM Grimer RJ

We investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the distal femur after resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database, review of the design of the implant and case records. In total, 335 patients underwent a distal femoral replacement, 162 having a fixed-hinge design and 173 a rotating-hinge. The median age of the patients was 24 years (interquartile range 17 to 48).

A total of 192 patients remained alive with a mean follow-up of 12 years (5 to 30). The risk of revision for any reason was 17% at five years, 33% at ten years and 58% at 20 years. Aseptic loosening was the main reason for revision of the fixed-hinge knees while infection and fracture of the stem were the most common for the rotating-hinge implant. The risk of revision for aseptic loosening was 35% at ten years with the fixed-hinge knee, which has, however, been replaced by the rotating-hinge knee with a hydroxyapatite collar. The overall risk of revision for any reason fell by 52% when the rotating-hinge implant was used.

Improvements in the design of distal femoral endoprostheses have significantly decreased the need for revision operations, but infection remains a serious problem. We believe that a cemented, rotating-hinge prosthesis with a hydroxyapatite collar offers the best chance of long-term survival of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 649 - 654
1 May 2006
Gupta A Meswania J Pollock R Cannon SR Briggs TWR Taylor S Blunn G

We report our early experience with the use of a non-invasive distal femoral expandable endoprosthesis in seven skeletally immature patients with osteosarcoma of the distal femur. The patients had a mean age of 12.1 years (9 to 15) at the time of surgery. The prosthesis was lengthened at appropriate intervals in outpatient clinics, without anaesthesia, using the principle of electromagnetic induction. The patients were functionally evaluated using the Musculoskeletal Tumour Society scoring system. The mean follow-up was 20.2 months (14 to 30). The prostheses were lengthened by a mean of 25 mm (4.25 to 55) and maintained a mean knee flexion of 110° (100° to 120°). The mean Musculoskeletal Tumour Society score was 68% (11 to 29). Complications developed in two patients; one developed a flexion deformity of 25° at the knee joint, which was subsequently overcome and one died of disseminated disease. The early results from patients treated with this device have been encouraging. The implant avoids multiple surgical procedures, general anaesthesia and assists in maintaining leg-length equality.