Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1150 - 1157
1 Oct 2024
de Klerk HH Verweij LPE Doornberg JN Jaarsma RL Murase T Chen NC van den Bekerom MPJ

Aims

This study aimed to gather insights from elbow experts using the Delphi method to evaluate the influence of patient characteristics and fracture morphology on the choice between operative and nonoperative treatment for coronoid fractures.

Methods

A three-round electronic (e-)modified Delphi survey study was performed between March and December 2023. A total of 55 elbow surgeons from Asia, Australia, Europe, and North America participated, with 48 completing all questionnaires (87%). The panellists evaluated the factors identified as important in literature for treatment decision-making, using a Likert scale ranging from "strongly influences me to recommend nonoperative treatment" (1) to "strongly influences me to recommend operative treatment" (5). Factors achieving Likert scores ≤ 2.0 or ≥ 4.0 were deemed influential for treatment recommendation. Stable consensus is defined as an agreement of ≥ 80% in the second and third rounds.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 110 - 119
21 Feb 2023
Macken AA Prkić A van Oost I Spekenbrink-Spooren A The B Eygendaal D

Aims

The aim of this study is to report the implant survival and factors associated with revision of total elbow arthroplasty (TEA) using data from the Dutch national registry.

Methods

All TEAs recorded in the Dutch national registry between 2014 and 2020 were included. The Kaplan-Meier method was used for survival analysis, and a logistic regression model was used to assess the factors associated with revision.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 232 - 238
1 Feb 2020
Javed S Hadi S Imam MA Gerogiannis D Foden P Monga P

Aims

Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method.

Methods

This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired t-test for significance and the Bland-Altman plot for agreement.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1100 - 1106
1 Sep 2019
Schemitsch C Chahal J Vicente M Nowak L Flurin P Lambers Heerspink F Henry P Nauth A

Aims

The purpose of this study was to compare the effectiveness of surgical repair to conservative treatment and subacromial decompression for the treatment of chronic/degenerative tears of the rotator cuff.

Materials and Methods

PubMed, Cochrane database, and Medline were searched for randomized controlled trials published until March 2018. Included studies were assessed for methodological quality, and data were extracted for statistical analysis. The systematic review was conducted following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 68 - 74
1 Jan 2019
Klemt C Toderita D Nolte D Di Federico E Reilly P Bull AMJ

Aims

Patients with recurrent anterior dislocation of the shoulder commonly have an anterior osseous defect of the glenoid. Once the defect reaches a critical size, stability may be restored by bone grafting. The critical size of this defect under non-physiological loading conditions has previously been identified as 20% of the length of the glenoid. As the stability of the shoulder is load-dependent, with higher joint forces leading to a loss of stability, the aim of this study was to determine the critical size of an osseous defect that leads to further anterior instability of the shoulder under physiological loading despite a Bankart repair.

Patients and Methods

Two finite element (FE) models were used to determine the risk of dislocation of the shoulder during 30 activities of daily living (ADLs) for the intact glenoid and after creating anterior osseous defects of increasing magnitudes. A Bankart repair was simulated for each size of defect, and the shoulder was tested under loading conditions that replicate in vivo forces during these ADLs. The critical size of a defect was defined as the smallest osseous defect that leads to dislocation.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 702 - 707
1 Jun 2019
Moeini S Rasmussen JV Salomonsson B Domeij-Arverud E Fenstad AM Hole R Jensen SL Brorson S

Aims

The aim of this study was to use national registry database information to estimate cumulative rates and relative risk of revision due to infection after reverse shoulder arthroplasty.

Patients and Methods

We included 17 730 primary shoulder arthroplasties recorded between 2004 and 2013 in The Nordic Arthroplasty Register Association (NARA) data set. With the Kaplan–Meier method, we illustrated the ten-year cumulative rates of revision due to infection and with the Cox regression model, we reported the hazard ratios as a measure of the relative risk of revision due to infection.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1688 - 1692
1 Dec 2014
Bouliane M Saliken D Beaupre LA Silveira A Saraswat MK Sheps DM

In this study we evaluated whether the Instability Severity Index Score (ISIS) and the Western Ontario Shoulder Instability Index (WOSI) could detect those patients at risk of failure following arthroscopic Bankart repair. Between April 2008 and June 2010, the ISIS and WOSI were recorded pre-operatively in 110 patients (87 male, 79%) with a mean age of 25.1 years (16 to 61) who underwent this procedure for recurrent anterior glenohumeral instability.

A telephone interview was performed two-years post-operatively to determine whether patients had experienced a recurrent dislocation and whether they had returned to pre-injury activity levels. In all, six (5%) patients had an ISIS > 6 points (0 to 9). Of 100 (91%) patients available two years post-operatively, six (6%) had a recurrent dislocation, and 28 (28%) did not return to pre-injury activity. No patient who dislocated had an ISIS > 6 (p = 1.0). There was no difference in the mean pre-operative WOSI in those who had a re-dislocation and those who did not (p = 0.99). The pre-operative WOSI was significantly lower (p = 0.02) in those who did not return to pre-injury activity, whereas the ISIS was not associated with return to pre-injury activity (p = 0.13).

In conclusion, neither the pre-operative ISIS nor WOSI predicted recurrent dislocation within two years of arthroscopic Bankart repair. Patients with a lower pre-operative WOSI were less likely to return to pre-injury activity.

Cite this article: Bone Joint J 2014; 96-B:1688–92.


Objectives

This investigation sought to advance the work published in our prior biomechanical study (Journal of Orthopaedic Research, 2016). We specifically sought to determine whether there are additional easy-to-measure parameters on plain radiographs of the proximal humerus that correlate more strongly with ultimate fracture load, and whether a parameter resembling the Dorr strength/quality characterisation of proximal femurs can be applied to humeri.

Materials and Methods

A total of 33 adult humeri were used from a previous study where we quantified bone mineral density of the proximal humerus using radiographs and dual-energy x-ray absorptiometry (DEXA), and regional mean cortical thickness and cortical index using radiographs. The bones were fractured in a simulated backwards fall with the humeral head loaded at 2 mm/second via a frustum angled at 30° from the long axis of the bone. Correlations were assessed with ultimate fracture load and these new parameters: cortical index expressed in areas (“areal cortical index”) of larger regions of the diaphysis; the canal-to-calcar ratio used analogous to its application in proximal femurs; and the recently described medial cortical ratio.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1383 - 1387
1 Oct 2013
Lanting BA Ferreira LM Johnson JA Athwal GS King GJW

We measured the tension in the interosseous membrane in six cadaveric forearms using an in vitro forearm testing system with the native radial head, after excision of the radial head and after metallic radial head replacement. The tension almost doubled after excision of the radial head during simulated rotation of the forearm (p = 0.007). There was no significant difference in tension in the interosseous membrane between the native and radial head replacement states (p = 0.09). Maximal tension occurred in neutral rotation with both the native and the replaced radial head, but in pronation if the radial head was excised. Under an increasing axial load and with the forearm in a fixed position, the rate of increase in tension in the interosseous membrane was greater when the radial head was excised than for the native radial head or replacement states (p = 0.02). As there was no difference in tension between the native and radial head replacement states, a radial head replacement should provide a normal healing environment for the interosseous membrane after injury or following its reconstruction. Load sharing between the radius and ulna becomes normal after radial head Replacement. As excision of the radial head significantly increased the tension in the interosseous membrane it may potentially lead to its attritional failure over time.

Cite this article: Bone Joint J 2013;95-B:1383–7.