High energy fractures of the pelvis are a challenging problem both in the immediate post-injury phase and later when definitive fixation is undertaken. No single management algorithm can be applied because of associated injuries and the wide variety of trauma systems that have evolved around the world. Initial management is aimed at saving life and this is most likely to be achieved with an approach that seeks to identify and treat life-threatening injuries in order of priority. Early mortality after a pelvic fracture is most commonly due to major haemorrhage or catastrophic brain injury. In this article we review the role of pelvic binders, angiographic embolisation, pelvic packing, early internal fixation and blood transfusion with regard to controlling haemorrhage. Definitive fixation seeks to prevent deformity and reduce complications. We believe this should be undertaken by specialist surgeons in a hospital resourced, equipped and staffed to manage the whole spectrum of major trauma. We describe the most common modes of internal fixation by injury type and review the factors that influence delayed mortality, adverse functional outcome, sexual dysfunction and venous thromboembolism.
Venous thromboembolism (VTE) remains an immediate
threat to patients following total hip and knee replacement. While
there is a strong consensus that steps should be taken to minimise
the risk to patients by utilising some forms of prophylaxis for
the vast majority of patients, the methods utilised have been extremely
variable. Clinical practice guidelines (CPGs) have been published
by various professional organisations for over 25 years to provide recommendations
to standardise VTE prophylaxis. Historically, these recommendations
have varied widely depending in underlying assumptions, goals, and
methodology of the various groups. This effort has previously been
exemplified by the American College of Chest Physicians (ACCP) and
the American Academy of Orthopaedic Surgeons (AAOS). The former
group of medical specialists targeted minimising venographically
proven deep vein thrombosis (DVT) (the vast majority of which are
asymptomatic) as their primary goal prior to 2012. The latter group of
surgeons targeted minimising symptomatic VTE. As a result prior
to 2012, the recommendations of the two groups were widely divergent.
In the past year, both groups have reassessed the current literature
with the principal goals of minimising symptomatic VTE events and
bleeding complications. As a result, for the first time the CPGs
of these two major subspecialty organisations are in close agreement.
The pathophysiology of intervertebral disc degeneration has been extensively studied. Various factors have been suggested as influencing its aetiology, including mechanical factors, such as compressive loading, shear stress and vibration, as well as ageing, genetic, systemic and toxic factors, which can lead to degeneration of the disc through biochemical reactions. How are these factors linked? What is their individual importance? There is no clear evidence indicating whether ageing in the presence of repetitive injury or repetitive injury in the absence of ageing plays a greater role in the degenerative process. Mechanical factors can trigger biochemical reactions which, in turn, may promote the normal biological changes of ageing, which can also be accelerated by genetic factors. Degradation of the molecular structure of the disc during ageing renders it more susceptible to superimposed mechanical injuries. This review supports the theory that degeneration of the disc has a complex multifactorial aetiology. Which factors initiate the events in the degenerative cascade is a question that remains unanswered, but most evidence points to an age-related process influenced primarily by mechanical and genetic factors.
The operative treatment of displaced fractures of the tibial plateau is challenging. Recent developments in the techniques of internal fixation, including the development of locked plating and minimal invasive techniques have changed the treatment of these fractures. We review current surgical approaches and techniques, improved devices for internal fixation and the clinical outcome after utilisation of new methods for locked plating.
A review of the current literature shows that there is a lack of consensus regarding the treatment of spondylolysis and spondylolisthesis in children and adolescents. Most of the views and recommendations provided in various reports are weakly supported by evidence. There is a limited amount of information about the natural history of the condition, making it difficult to compare the effectiveness of various conservative and operative treatments. This systematic review summarises the current knowledge on spondylolysis and spondylolisthesis and attempts to present a rational approach to the evaluation and management of this condition in children and adolescents.
The mammalian growth plate is a complex structure which is essential for the elongation of long bones. However, an understanding of how the growth plate functions at the cellular level is lacking. This review, summarises the factors involved in growth-plate regulation, its failure and the consequence of injury. We also describe some of the cellular mechanisms which underpin the increase in volume of the growth-plate chondrocyte which is the major determinant of the rate and extent of bone lengthening. We show how living in situ chondrocytes can be imaged using 2-photon laser scanning microscopy to provide a quantitative analysis of their volume. This approach should give better understanding of the cellular control of bone growth in both healthy and failed growth plates.
With the development of systems of trauma care the management of pelvic disruption has evolved and has become increasingly refined. The goal is to achieve an anatomical reduction and stable fixation of the fracture. This requires adequate visualisation for reduction of the fracture and the placement of fixation. Despite the advances in surgical approach and technique, the functional outcomes do not always produce the desired result. New methods of percutaneous treatment in conjunction with innovative computer-based imaging have evolved in an attempt to overcome the existing difficulties. This paper presents an overview of the technical aspects of percutaneous surgery of the pelvis and acetabulum.
The dismal outcome of tuberculosis of the spine in the pre-antibiotic era has improved significantly because of the use of potent antitubercular drugs, modern diagnostic aids and advances in surgical management. MRI allows the diagnosis of a tuberculous lesion, with a sensitivity of 100% and specificity of 88%, well before deformity develops. Neurological deficit and deformity are the worst complications of spinal tuberculosis. Patients treated conservatively show an increase in deformity of about 15°. In children, a kyphosis continues to increase with growth even after the lesion has healed. Tuberculosis of the spine is a medical disease which is not primarily treated surgically, but operation is required to prevent and treat the complications. Panvertebral lesions, therapeutically refractory disease, severe kyphosis, a developing neurological deficit, lack of improvement or deterioration are indications for surgery. Patients who present with a kyphosis of 60° or more, or one which is likely to progress, require anterior decompression, posterior shortening, posterior instrumented stabilisation and anterior and posterior bone grafting in the active stage of the disease. Late-onset paraplegia is best prevented rather than treated. The awareness and suspicion of an atypical presentation of spinal tuberculosis should be high in order to obtain a good outcome. Therapeutically refractory cases of tuberculosis of the spine are increasing in association with the presence of HIV and multidrug-resistant tuberculosis.
Despite advances in the prevention and treatment of osteoporotic fractures, their prevalence continues to increase. Their operative treatment remains a challenge for the surgeon, often with unpredictable outcomes. This review highlights the current aspects of management of these fractures and focuses on advances in implant design and surgical technique.
The fracture most commonly treated by orthopaedic surgeons is that of the distal radius. However, as yet there is no consensus on what constitutes an ‘acceptable’ radiological position before or after treatment. This should be defined as the position that will predict good function in the majority of cases. In this paper we review the radiological indices that can be measured in fractures of the distal radius and try to identify potential predictors of functional outcome. In patients likely to have high functional demands, we recommend that the articular reconstruction be achieved with less than 2 mm of gap or step-off, the radius be restored to within 2 mm of its normal length, and that carpal alignment be restored. The ultimate aim of treatment is a pain-free, mobile wrist joint without functional limitation.
Polymethylmethacrylate remains one of the most enduring materials in orthopaedic surgery. It has a central role in the success of total joint replacement and is also used in newer techniques such as percutaneous vertebroplasty and kyphoplasty. This article describes the current uses and limitations of polymethylmethacrylate in orthopaedic surgery. It focuses on its mechanical and chemical properties and links these to its clinical performance. The behaviour of antibiotic-loaded bone cement are discussed, together with areas of research that are now shedding light upon the behaviour of this unique biomaterial.
This paper reviews the current literature concerning the main clinical factors which can impair the healing of fractures and makes recommendations on avoiding or minimising these in order to optimise the outcome for patients. The clinical implications are described.
Most proximal humeral fractures are stable injuries of the ageing population, and can be successfully treated non-operatively. The management of the smaller number of more complex displaced fractures is more controversial and new fixation techniques have greatly increased the range of fractures that may benefit from surgery. This article explores current concepts in the classification and clinical aspects of these injuries, reviewing the indications, innovations and outcomes for the most common methods of treatment.
We undertook a review of the literature relating to the two basic stem designs in use in cemented hip replacement, namely loaded tapers or force-closed femoral stems, and the composite beam or shape-closed designs. The associated stem fixation theory as understood from It is clear that both design principles are capable of producing successful long-term results, providing that their specific requirements of stem metallurgy, shape and surface finish, preparation of the bone and handling of the cement are observed.