Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 579 - 582
1 Nov 1978
Hughes S Khan R Davies R Lavender P

The residue and extraction of technetium-labelled methylene diphosphonate (99mTc-MDP), a substance used in bone scanning, was examined in the canine tibia and found to be low. Examination of washout curves suggested that there were four compartments in cortical bone, a vascular, a perivascular, a bone fluid and a bone compartment. After an osteotomy in the canine tibia the residue of 99mTc-MDP increased. This was believed to be due to an increase in the blood supply to the bone and to an associated increase in new bone available for exchange. Bone scanning in a fracture is therefore a reflection of the vascular status of the bone being examined and of the uptake by bone. This is dependent on there being an adequate blood supply to the bone and an increased number of mineral-binding sites


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 123 - 128
1 Jan 1997
Maniar RN Todd RC Robinson S Critchley M

We studied the pattern of 99mTc-methylene diphosphonate uptake around uncemented femoral components in 44 asymptomatic hip arthroplasties, performing isotope scans at intervals from 4 to 48 months after operation. We used phase-III images obtained with a high-resolution gamma camera and measured the activity in various zones using a specially designed computer program. The components studied at 4, 6, 9 and 12 months were coated with hydroxyapatite (HA) and those studied at 18, 24, 36 and 48 months were not coated.

We found a statistically significant fall in activity between four and six months around HA-coated prostheses in all five femoral periprosthetic zones. After six months activity was relatively uniform, but remained higher than that in normal femoral bone at 48 months in non-coated prostheses. We discuss the application of these patterns in the evaluation of painful cementless hip arthroplasties.


Bone & Joint Research
Vol. 11, Issue 6 | Pages 398 - 408
22 Jun 2022
Xu T Zeng Y Yang X Liu G Lv T Yang H Jiang F Chen Y

Aims

We aimed to evaluate the utility of 68Ga-citrate positron emission tomography (PET)/CT in the differentiation of periprosthetic joint infection (PJI) and aseptic loosening (AL), and compare it with 99mTc-methylene bisphosphonates (99mTc-MDP) bone scan.

Methods

We studied 39 patients with suspected PJI or AL. These patients underwent 68Ga-citrate PET/CT, 99mTc-MDP three-phase bone scan and single-photon emission CT (SPECT)/CT. PET/CT was performed at ten minutes and 60 minutes after injection, respectively. Images were evaluated by three nuclear medicine doctors based on: 1) visual analysis of the three methods based on tracer uptake model, and PET images attenuation-corrected with CT and those not attenuation-corrected with CT were analyzed, respectively; and 2) semi-quantitative analysis of PET/CT: maximum standardized uptake value (SUVmax) of lesions, SUVmax of the lesion/SUVmean of the normal bone, and SUVmax of the lesion/SUVmean of the normal muscle. The final diagnosis was based on the clinical and intraoperative findings, and histopathological and microbiological examinations.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 441 - 447
1 May 1987
Smith M Jones E Strachan R Nicoll J Best J Tothill P Hughes S

The uptake of 99mTc-MDP was studied in 73 patients after a tibial fracture. The image obtained five minutes after injection during a period between one and four weeks after fracture was found to be related to the incidence of non-union after six months. A ratio of 1.3 between the uptake at the fracture site and at normal bone adjacent to it predicted non-union in an individual patient with a sensitivity of about 70% and a specificity of 90%


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 49 - 54
1 Jan 1984
Stromqvist B Hansson L Ljung P Ohlin P Roos H

In 22 patients with femoral neck fractures 99mTc-MDP scintimetry was performed before operation and again shortly after operation; in 17 of these patients the investigation was repeated after four months. Six patients with increased uptake in the femoral head before operation and eight with decreased uptake had similar results at the first postoperative investigation. Of eight patients with an intermediate uptake before operation, two showed increased and six decreased femoral head uptake after operation. It is concluded that for the patients in the group with intermediate femoral head uptake before operation, the operative procedure probably influenced the postoperative blood supply of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 2 | Pages 221 - 224
1 May 1979
Khan R Hughes S Lavender P Leon M Spyrou N

The passage of technetium-labelled methylene diphosphonate (99mTc-MDP) across rat bone was examined by autoradiography. The autoradiographs showed that shortly after an injection of the bone-seeking agent there was activity outside the bone, within the bone marrow and also adjacent to the highly vascular epiphysial plate; the distribution of the isotope in the incubated bone appeared to be non-uniform, a high concentration being seen adjacent to the epiphysial plate and also on the surfaces of the bone. The evidence suggested that a two-fold mechanism resulted in the uneven distribution of 99mTc-MDP. The first factor probably represented the regional distribution of blood flow with a transcapillary movement of the tracer from the capillary bed to the extravascular space; the subsequent incorporation of the tracer into bone appeared to depend on the nature of the bone matrix


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 806 - 814
1 Sep 1995
Boyer M Danska J Nolan L Kiral A Bowen C

We compared growth in vascularised allograft transplants, autografts and in non-operated physes in rabbits immunosuppressed with cyclosporin A and in non-immunosuppressed animals. Molecular haplotyping was undertaken before operation to ensure allogenicity. Postoperative bone scans and fluorochrome labelling were used to confirm physeal vascularity. The animals were killed at three or five weeks. Proximal tibial physeal autografts, with or without cyclosporin A, or allografts with cyclosporin A, grew at similar rates to the physes of non-operated rabbits. All the operated physes grew at rates significantly greater than their contralateral controls. 99mTc-MDP bone scans accurately predicted the viability of the epiphyseal plate. Quantitative histomorphological analysis of the heights of the physeal proliferative and hypertrophic zones showed that successful physeal transplants have a normal appearance, but when unsuccessful have thickened hypertrophic zones compatible with physeal ischaemia. We discuss the significance of these results in relation to the transplantation of physes in children


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1077 - 1085
1 Aug 2012
Yin Z Zhang J Kan S Wang X

Follow-up radiographs are usually used as the reference standard for the diagnosis of suspected scaphoid fractures. However, these are prone to errors in interpretation. We performed a meta-analysis of 30 clinical studies on the diagnosis of suspected scaphoid fractures, in which agreement data between any of follow-up radiographs, bone scintigraphy, magnetic resonance (MR) imaging, or CT could be obtained, and combined this with latent class analysis to infer the accuracy of these tests on the diagnosis of suspected scaphoid fractures in the absence of an established standard. The estimated sensitivity and specificity were respectively 91.1% and 99.8% for follow-up radiographs, 97.8% and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2% and 99.5% for CT. The results were generally robust in multiple sensitivity analyses. There was large between-study heterogeneity for the sensitivity of follow-up radiographs and CT, and imprecision about their sensitivity estimates.

If we acknowledge the lack of a reference standard for diagnosing suspected scaphoid fractures, MRI is the most accurate test; follow-up radiographs and CT may be less sensitive, and bone scintigraphy less specific.