Advertisement for orthosearch.org.uk
Results 1 - 20 of 199
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 548 - 554
1 Apr 2016
Midbari A Suzan E Adler T Melamed E Norman D Vulfsons S Eisenberg E

Aims. Amputation in intractable cases of complex regional pain syndrome (CRPS) remains controversial. . The likelihood of recurrent Complex Regional Pain Syndrome (CRPS), residual and phantom limb pain and persistent disability after amputation is poorly described in the literature. The aims of this study were to compare pain, function, depression and quality of life between patients with intractable CRPS who underwent amputation and those in whom amputation was considered but not performed. Patients and Methods. There were 19 patients in each group, with comparable demographic details. The amputated group included 14 men and five women with a mean age of 31 years (. sd. 12) at the time of CRPS diagnosis. The non-amputated group consisted of 12 men and seven women and their mean age of 36.8 years (. sd. 8) at CRPS diagnosis. The mean time from CRPS diagnosis to (first) amputation was 5.2 years (. sd 4. 3) and the mean time from amputation to data collection was 6.6 years (. sd. 5.8). . All participants completed the following questionnaires: Short-Form (SF) 36, Short Form McGill Pain questionnaire (SF-MPQ), Pain Disability Index (PDI), the Beck Depression Inventory (BDI) and a clinical demographic questionnaire. . Results. The amputation group showed consistently better results compared to the non-amputation group in the following parameters: median pain intensity (VAS): 80 (inter-quartile range (IQR) 13 to 92) vs 91 (IQR 85 to 100); p = 0.007; median SF-MPQ score 28 (IQR 9 to 35) vs 35 (IQR 31 to 38), p = 0.025; median PDI: 42 (IQR 11 to 64) vs 58 (IQR 50 to 62), p = 0.031; median BDI: 19 (IQR 5 to 28) vs 27 (IQR 21 to 32), p = 0.061 (borderline significant) and in six of the eight SF-36 domains. . Take home message: Amputation should be considered as a form of treatment for patients with intractable CRPS. Cite this article: Bone Joint J 2016;98-B:548–54


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 55 - 63
1 Jan 2020
Hagberg K Ghassemi Jahani S Kulbacka-Ortiz K Thomsen P Malchau H Reinholdt C

Aims. The aim of this study was to describe implant and patient-reported outcome in patients with a unilateral transfemoral amputation (TFA) treated with a bone-anchored, transcutaneous prosthesis. Methods. In this cohort study, all patients with a unilateral TFA treated with the Osseointegrated Prostheses for the Rehabilitation of Amputees (OPRA) implant system in Sahlgrenska University Hospital, Gothenburg, Sweden, between January 1999 and December 2017 were included. The cohort comprised 111 patients (78 male (70%)), with a mean age 45 years (17 to 70). The main reason for amputation was trauma in 75 (68%) and tumours in 23 (21%). Patients answered the Questionnaire for Persons with Transfemoral Amputation (Q-TFA) before treatment and at two, five, seven, ten, and 15 years’ follow-up. A prosthetic activity grade was assigned to each patient at each timepoint. All mechanical complications, defined as fracture, bending, or wear to any part of the implant system resulting in removal or change, were recorded. Results. The Q-TFA scores at two, five, seven, and ten years showed significantly more prosthetic use, better mobility, fewer problems, and an improved global situation, compared with baseline. The survival rate of the osseointegrated implant part (the fixture) was 89% and 72% after seven and 15 years, respectively. A total of 61 patients (55%) had mechanical complications (mean 3.3 (SD 5.76)), resulting in exchange of the percutaneous implant parts. There was a positive relationship between a higher activity grade and the number of mechanical complications. Conclusion. Compared with before treatment, the patient-reported outcome was significantly better and remained so over time. Although osseointegration and the ability to transfer loads over a 15-year period have been demonstrated, a large number of mechanical failures in the external implant parts were found. Since these were related to higher activity, restrictions in activity and improvements to the mechanical properties of the implant system are required. Cite this article: Bone Joint J 2020;102-B(1):55–63


Aims. The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) may improve quality of life for amputees by avoiding soft-tissue complications associated with socket prostheses and by improving sensory feedback and function. It relies on the formation of a seal between the soft tissues and the implant and currently has a flange with drilled holes to promote dermal attachment. Despite this, infection remains a significant risk. This study explored alternative strategies to enhance soft-tissue integration. Materials and Methods. The effect of ITAP pins with a fully porous titanium alloy flange with interconnected pores on soft-tissue integration was investigated. The flanges were coated with fibronectin-functionalised hydroxyapatite and silver coatings, which have been shown to have an antibacterial effect, while also promoting viable fibroblast growth in vitro. The ITAP pins were implanted along the length of ovine tibias, and histological assessment was undertaken four weeks post-operatively. Results. The porous titanium alloy flange reduced epithelial downgrowth and increased soft-tissue integration compared with the current drilled flange. The addition of coatings did not enhance these effects. Conclusion. These results indicate that a fully porous titanium alloy flange has the potential to increase the soft-tissue seal around ITAP and reduce susceptibility to infection compared with the current design. Cite this article: Bone Joint J 2017;99-B:393–400


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 106 - 113
1 Jan 2014
Brånemark R Berlin Ö Hagberg K Bergh P Gunterberg B Rydevik B

Patients with transfemoral amputation (TFA) often experience problems related to the use of socket-suspended prostheses. The clinical development of osseointegrated percutaneous prostheses for patients with a TFA started in 1990, based on the long-term successful results of osseointegrated dental implants. Between1999 and 2007, 51 patients with 55 TFAs were consecutively enrolled in a prospective, single-centre non-randomised study and followed for two years. The indication for amputation was trauma in 33 patients (65%) and tumour in 12 (24%). A two-stage surgical procedure was used to introduce a percutaneous implant to which an external amputation prosthesis was attached. The assessment of outcome included the use of two self-report questionnaires, the Questionnaire for Persons with a Transfemoral Amputation (Q-TFA) and the Short-Form (SF)-36. The cumulative survival at two years’ follow-up was 92%. The Q-TFA showed improved prosthetic use, mobility, global situation and fewer problems (all p < 0.001). The physical function SF-36 scores were also improved (p < 0.001). Superficial infection was the most frequent complication, occurring 41 times in 28 patients (rate of infection 54.9%). Most were treated effectively with oral antibiotics. The implant was removed in four patients because of loosening (three aseptic, one infection). Osseointegrated percutaneous implants constitute a novel form of treatment for patients with TFA. The high cumulative survival rate at two years (92%) combined with enhanced prosthetic use and mobility, fewer problems and improved quality of life, supports the ‘revolutionary change’ that patients with TFA have reported following treatment with osseointegrated percutaneous prostheses. Cite this article: Bone Joint J 2014;96-B:106–13


Bone & Joint Open
Vol. 4, Issue 3 | Pages 146 - 157
7 Mar 2023
Camilleri-Brennan J James S McDaid C Adamson J Jones K O'Carroll G Akhter Z Eltayeb M Sharma H

Aims

Chronic osteomyelitis (COM) of the lower limb in adults can be surgically managed by either limb reconstruction or amputation. This scoping review aims to map the outcomes used in studies surgically managing COM in order to aid future development of a core outcome set.

Methods

A total of 11 databases were searched. A subset of studies published between 1 October 2020 and 1 January 2011 from a larger review mapping research on limb reconstruction and limb amputation for the management of lower limb COM were eligible. All outcomes were extracted and recorded verbatim. Outcomes were grouped and categorized as per the revised Williamson and Clarke taxonomy.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 21 - 28
1 Jan 2023
Ndlovu S Naqshband M Masunda S Ndlovu K Chettiar K Anugraha A

Aims

Clinical management of open fractures is challenging and frequently requires complex reconstruction procedures. The Gustilo-Anderson classification lacks uniform interpretation, has poor interobserver reliability, and fails to account for injuries to musculotendinous units and bone. The Ganga Hospital Open Injury Severity Score (GHOISS) was designed to address these concerns. The major aim of this review was to ascertain the evidence available on accuracy of the GHOISS in predicting successful limb salvage in patients with mangled limbs.

Methods

We searched electronic data bases including PubMed, CENTRAL, EMBASE, CINAHL, Scopus, and Web of Science to identify studies that employed the GHOISS risk tool in managing complex limb injuries published from April 2006, when the score was introduced, until April 2021. Primary outcome was the measured sensitivity and specificity of the GHOISS risk tool for predicting amputation at a specified threshold score. Secondary outcomes included length of stay, need for plastic surgery, deep infection rate, time to fracture union, and functional outcome measures. Diagnostic test accuracy meta-analysis was performed using a random effects bivariate binomial model.


Bone & Joint Research
Vol. 10, Issue 10 | Pages 690 - 692
1 Oct 2021
Hoellwarth JS Tetsworth K Akhtar MA Al Muderis M


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 836 - 836
1 Sep 1995
Thomas M Fast A


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 270 - 273
1 Mar 1995
Dielissen P Claassen A Veldman P Goris R

We have reviewed 28 patients with reflex sympathetic dystrophy (RSD) who had 34 amputations in 31 limbs. The amputations had been performed for untenable pain (5), recurrent infection (14) or to improve residual function (15). Only two patients were relieved of pain by amputation, and this could not be predicted. Ten of 14 patients were cured of infection and 9 of 15 patients had improvement of residual function. In 28 of the amputations, RSD recurred in the stump, especially after amputation at a level which was not free from symptoms. Because of recurrence of RSD in the stump or severe hyperpathia only two patients wear a prosthesis. Despite this 24 patients were satisfied with the results.


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 3 | Pages 268 - 269
1 Aug 1975
Sweetnam R


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 1 | Pages 189 - 192
1 Feb 1973
Sweetnam R

1. The question whether amputation for lower femoral osteosarcoma should be by disarticulation of the hip or through the upper femur to leave a stump is discussed.

2. Sixty-eight such patients are reviewed. Thirty were treated by disarticulation and thirty-eight by through-femur amputation.

3. There was a 16 per cent incidence of stump recurrence after through-femur amputation, but none after disarticulation. Comparison of survival was not conclusive.

4. Disarticulation of the hip is advised.


The Journal of Bone & Joint Surgery British Volume
Vol. 39-B, Issue 2 | Pages 221 - 223
1 May 1957
Harding HE Langdale-Kelham R


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 3 | Pages 404 - 409
1 Aug 1949
Brittain HA


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 149 - 150
1 Jan 1996
Kornah B


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 3 | Pages 482 - 487
1 Aug 1969
Baker GCW Stableforth PG

1. All traceable Syme amputees attending the Edinburgh limb centre have been seen and reviewed. They number sixty-seven. Forty had amputations twenty-five or more years before.

2. There are seventy-one surviving stumps. One has failed.

3. Records of all the below-knee amputees reveal five further failures of Syme stumps. The causes of failure are discussed.

4. Problems in the Syme stump are rare after the first year. The early difficulties are discussed.

5. We conclude that a patient with Syme's amputation can expect his stump to give a lifetime of service.


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 3 | Pages 388 - 392
1 Aug 1964
Hicks JH

1. The conservative school of treatment of fractures of the tibia, which bases part of its criticism of internal fixation on the ultimate risk of amputation, does not often publish its own rates of amputation.

2. Statistics from a hospital that treats one-third of closed fractured tibiae and two-thirds of compound fractures by internal fixation are therefore put up as a basis for criticism.

3. Comparisons are made with the few available statistics in the literature of conservative treatment.

4. Almost all of the causes for secondary amputation are now curable and in recent years the number of limbs being saved is increasing.


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 1 | Pages 90 - 96
1 Feb 1960
Flint M Sweetnam R

1. The indications for amputation of all the toes for severe toe deformity in rheumatoid arthritis, hallux valgus and pes cavus are discussed.

2. The results of forty-seven amputations in twenty-eight patients are analysed: 93 per cent were found to be very satisfied with the operation.

3. The technique of the operation and the subsequent management are described. The importance of retaining full-length shoes fitted with metatarsal insoles and toe blocks to preserve a good gait and balance is emphasised.


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 412 - 412
1 May 1960
Fowler AW Flint M Sweetnam R


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 3 | Pages 468 - 470
1 Aug 1955
Macdonald A


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 3 | Pages 614 - 632
1 Aug 1956
Harris RI

The details in technique which are most essential to ensure a perfect Syme's stump are the provision of a broad area of support for the heel flap by transecting the tibia and fibula as low as possible; the maintaining intact of the specialised weight-bearing qualities of the heel flap; and the proper placement of the heel flap under the cut ends of the tibia and fibula. If these aims are achieved a good and useful stump is assured; if they are neglected the stump will be imperfect and may be unsatisfactory and no further operation can restore the qualities of the heel flap which are lacking.

It must be recorded, however, that Syme's stumps which are not technically perfect often function so well that there has been no need to consider re-amputation. A loose heel pad can be held beneath the end of the bone by firm lacing of the corset of the prosthesis.If its area of bony support is reasonably large it may serve well, though not perfectly, as an end-bearing stump. Syme's stumps so completely unsatisfactory as to necessitate re-amputation have been those in which the plane of transection of the tibia is so high that the area supporting the heel flap is too small; or the weight-bearing qualities of the heel flap have been damaged; or there is instability of the heel flap which cannot be controlled; or there is impairment of nutrition of the heel flap.