Unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA) have both been shown to be effective treatments for osteoarthritis (OA) of the knee. Many studies have compared the outcomes of the two treatments, but less so with the use of robotics, or individualized TKA alignment techniques. Functional alignment (FA) is a novel technique for performing a TKA and shares many principles with UKA. Our aim was to compare outcomes from a case-matched series of robotic-assisted UKAs and robotic-assisted TKAs performed using FA. From a prospectively collected database between April 2015 and December 2019, patients who underwent a robotic-assisted medial UKA (RA-UKA) were case-matched with patients who had undergone a FA robotic-assisted TKA (RA-TKA) during the same time period. Patients were matched for preoperative BMI, sex, age, and Forgotten Joint Score (FJS). A total of 101 matched pairs were eligible for final review. Postoperatively the groups were then compared for differences in patient-reported outcome measures (PROMs), range of motion (ROM), ability to ascend and descend stairs, and ability to kneel.Aims
Methods
The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs). This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.Aims
Methods
A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits.Aims
Methods
Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction).Aims
Methods
Aims. Platelet-rich plasma (PRP) intra-articular injections may provide a simple and minimally invasive treatment for early-stage knee osteoarthritis (OA). This has led to an increase in its adoption as a treatment for knee OA, although there is uncertainty about its efficacy and benefit. We hypothesized that patients with early-stage symptomatic knee OA who receive multiple PRP injections will have better clinical outcomes than those receiving single PRP or placebo injections. Methods. A double-blinded, randomized placebo-controlled trial was performed with three groups receiving either placebo injections (Normal Saline), one PRP injection followed by two placebo injections, or three PRP injections. Each injection was given one week apart. Outcomes were prospectively collected prior to intervention and then at six weeks, three months, six months, and 12 months post-intervention. Primary outcome measures were Knee Injury and Osteoarthritis Outcome Score (KOOS) and EuroQol five-dimension five-level index (EQ-5D-5L). Secondary outcomes included
Aims. Single-shot adductor canal block (ACB) after total knee arthroplasty (TKA) for postoperative analgesia is a common modality. Patients can experience breakthrough pain when the effect of ACB wears off. Local anaesthetic infusion through an intra-articular catheter (IAC) can help manage breakthrough pain after TKA. We hypothesized that combined ACB with ropivacaine infusion through IAC is associated with better pain relief compared to ACB used alone. Methods. This study was a prospective double-blinded placebo-controlled randomized controlled trial to compare the efficacy of combined ACB+ IAC-ropivacaine infusion (study group, n = 68) versus single-shot ACB+ intra-articular normal saline placebo (control group, n = 66) after primary TKA. The primary outcome was assessment of
The aims of this study were to investigate the ability to kneel after total knee arthroplasty (TKA) without patellar resurfacing, and its effect on patient-reported outcome measures (PROMs). Secondary aims included identifying which kneeling positions were most important to patients, and the influence of radiological parameters on the ability to kneel before and after TKA. This prospective longitudinal study involved 209 patients who underwent single radius cruciate-retaining TKA without patellar resurfacing. Preoperative EuroQol five-dimension questionnaire (EQ-5D), Oxford Knee Score (OKS), and the ability to achieve four kneeling positions were assessed including a single leg kneel, a double leg kneel, a high-flexion kneel, and a praying position. The severity of radiological osteoarthritis (OA) was graded and the pattern of OA was recorded intraoperatively. The flexion of the femoral component, posterior condylar offset, and anterior femoral offset were measured radiologically. At two to four years postoperatively, 151 patients with a mean age of 70.0 years (SD 9.44) were included. Their mean BMI was 30.4 kg/m2 (SD 5.36) and 60 were male (40%). They completed EQ-5D, OKS, and Kujala scores, assessments of the ability to kneel, and a visual analogue scale for anterior knee pain and satisfaction.Aims
Methods
Aims. Manipulation under anaesthesia (MUA) remains an effective intervention to address restricted range of motion (ROM) after total knee arthroplasty (TKA) and occurs in 2% to 3% of primary TKAs at our institution. Since there are few data on the outcomes of MUA with different anaesthetic methods, we sought to compare the outcomes of patients undergoing MUA with intravenous (IV) sedation and neuraxial anaesthesia. Methods. We identified 548 MUAs after primary TKA (136 IV sedation, 412 neuraxial anaesthesia plus IV sedation) from March 2016 to July 2019. The mean age of this cohort was 62 years (35 to 88) with a mean body mass index of 31 kg/m. 2. (18 to 49). The mean time from primary TKA to MUA was 10.2 weeks (6.2 to 24.3). Pre-MUA ROM was similar between groups; overall mean pre-MUA extension was 4.2° (p = 0.452) and mean pre-MUA flexion was 77° (p = 0.372). We compared orthopaedic complications,
Many patients undergoing total knee arthroplasty (TKA) have severe osteoarthritis (OA) in both knees and may consider either simultaneous or staged bilateral TKA. The implications of simultaneous versus staged bilateral TKA for return to work are not well understood. We hypothesized that employed patients who underwent simultaneous bilateral TKA would have significantly fewer days missed from work compared with the sum of days missed from each operation for patients who underwent staged bilateral TKA. The prospective arthroplasty registry at the Hospital for Special Surgery was used. Baseline characteristics and patient-reported outcome scores were evaluated. We used a linear regression model, adjusting for potential confounding variables including age, sex, preoperative BMI, and type of work (sedentary, moderate, high activity, or strenuous), to analyze time lost from work after simultaneous compared with staged bilateral TKA.Aims
Methods
Cementless knee arthroplasty has seen a recent resurgence in popularity due to conceptual advantages, including improved osseointegration providing biological fixation, increased surgical efficiency, and reduced systemic complications associated with cement impaction and wear from cement debris. Increasingly younger and higher demand patients are requiring knee arthroplasty, and as such, there is optimism cementless fixation may improve implant survivorship and functional outcomes. Compared to cemented implants, the National Joint Registry (NJR) currently reports higher revision rates in cementless total knee arthroplasty (TKA), but lower in unicompartmental knee arthroplasty (UKA). However, recent studies are beginning to show excellent outcomes with cementless implants, particularly with UKA which has shown superior performance to cemented varieties. Cementless TKA has yet to show long-term benefit, and currently performs equivalently to cemented in short- to medium-term cohort studies. However, with novel concepts including 3D-printed coatings, robotic-assisted surgery, radiostereometric analysis, and kinematic or functional knee alignment principles, it is hoped they may help improve the outcomes of cementless TKA in the long-term. In addition, though cementless implant costs remain higher due to novel implant coatings, it is speculated cost-effectiveness can be achieved through greater surgical efficiency and potential reduction in revision costs. There is paucity of level one data on long-term outcomes between fixation methods and the cost-effectiveness of modern cementless knee arthroplasty. This review explores recent literature on cementless knee arthroplasty, with regards to clinical outcomes, implant survivorship, complications, and cost-effectiveness; providing a concise update to assist clinicians on implant choice. Cite this article:
Aims. The aim of this study was to examine whether tourniquet use can improve perioperative blood loss, early function recovery, and pain after primary total knee arthroplasty (TKA) in the setting of multiple-dose intravenous tranexamic acid. Methods. This was a prospective, randomized clinical trial including 180 patients undergoing TKA with multiple doses of intravenous tranexamic acid. One group was treated with a tourniquet during the entire procedure, the second group received a tourniquet during cementing, and the third group did not receive a tourniquet. All patients received the same protocol of intravenous tranexamic acid (20 mg/kg) before skin incision, and three and six hours later (10 mg/kg). The primary outcome measure was perioperative blood loss. Secondary outcome measures were creatine kinase (CK), CRP, interleukin-6 (IL-6),
Aims
Patients and Methods
Aims. Multimodal infiltration of local anaesthetic provides effective
control of pain in patients undergoing total knee arthroplasty (TKA).
There is little information about the added benefits of posterior
capsular infiltration (PCI) using different combinations of local
anaesthetic agents. Our aim was to investigate the effectiveness
of the control of pain using multimodal infiltration with and without
infiltration of the posterior capsule of the knee. Patients and Methods. In a double-blind, randomised controlled trial of patients scheduled
for unilateral primary TKA, 86 were assigned to be treated with
multimodal infiltration with (Group I) or without (Group II) PCI.
Routine associated analgesia included the use of bupivacaine, morphine,
ketorolac and epinephrine. All patients had spinal anaesthesia and patient-controlled
analgesia (PCA) post-operatively. A
Knee joint distraction (KJD) is a relatively new, knee-joint
preserving procedure with the goal of delaying total knee arthroplasty
(TKA) in young and middle-aged patients. We present a randomised
controlled trial comparing the two. The 60 patients ≤ 65 years with end-stage knee osteoarthritis
were randomised to either KJD (n = 20) or TKA (n = 40). Outcomes
were assessed at baseline, three, six, nine, and 12 months. In the
KJD group, the joint space width (JSW) was radiologically assessed,
representing a surrogate marker of cartilage thickness.Aims
Patients and Methods
Aims. We wished to compare the clinical outcome, as assessed by questionnaires
and the rate of complications, in total knee arthroplasty (TKA)
undertaken with patient-matched positioning guides (PMPGs) or conventional
instruments. Patients and Methods. A total of 180 patients (74 men, 106 women; mean age 67 years)
were included in a multicentre, adequately powered, double-blind,
randomised controlled trial. The mean follow-up was 44 months (24
to 57). Results. There were no significant or clinically relevant differences
between the two groups for all outcome measures (Knee Society Score,
p = 0.807; Oxford Knee Score, p = 0.304; Western Ontario and McMaster
osteoarthritis index, p = 0.753;
There is conflicting evidence about the benefit
of using corticosteroid in periarticular injections for pain relief
after total knee arthroplasty (TKA). We carried out a double-blinded,
randomised controlled trial to assess the efficacy of using corticosteroid
in a periarticular injection to control pain after TKA. A total of 77 patients, 67 women and ten men, with a mean age
of 74 years (47 to 88) who were about to undergo unilateral TKA
were randomly assigned to have a periarticular injection with or
without corticosteroid. The primary outcome was post-operative pain
at rest during the first 24 hours after surgery, measured every
two hours using a visual analogue pain scale score. The cumulative
pain score was quantified using the area under the curve. The corticosteroid group had a significantly lower cumulative
pain score than the no-corticosteroid group during the first 24
hours after surgery (mean area under the curve 139, 0 to 560, and
264, 0 to 1460; p = 0.024). The rate of complications, including
surgical site infection, was not significantly different between
the two groups up to one year post-operatively. The addition of corticosteroid to the periarticular injection
significantly decreased early post-operative pain. Further studies
are needed to confirm the safety of corticosteroid in periarticular
injection.
Cite this article:
The treatment of osteochondral lesions is of
great interest to orthopaedic surgeons because most lesions do not heal
spontaneously. We present the short-term clinical outcome and MRI
findings of a cell-free scaffold used for the treatment of these
lesions in the knee. A total of 38 patients were prospectively evaluated
clinically for two years following treatment with an osteochondral
nanostructured biomimetic scaffold. There were 23 men and 15 women; the
mean age of the patients was 30.5 years (15 to 64). Clinical outcome
was assessed using the Knee Injury and Osteoarthritis Outcome Score
(KOOS), the Tegner activity scale and a Visual Analgue scale for
pain. MRI data were analysed based on the Magnetic Resonance Observation
of Cartilage Repair Tissue (MOCART) scoring system at three, 12
and 24 months post-operatively. There was a continuous significant
clinical improvement after surgery. In two patients, the scaffold
treatment failed (5.3%) There was a statistically significant improvement
in the MOCART precentage scores. The repair tissue filled most of
the defect sufficiently. We found subchondral laminar changes in all
patients. Intralesional osteophytes were found in two patients (5.3%).
We conclude that this one-step scaffold-based technique can be used
for osteochondral repair. The surgical technique is straightforward,
and the clinical results are promising. The MRI aspects of the repair
tissue continue to evolve during the first two years after surgery.
However, the subchondral laminar and bone changes are a concern. Cite this article:
A total of 187 patients with primary osteoarthritis
(OA) of the knee undergoing total knee replacement (TKR) were randomly
divided into two groups, one of which underwent synovectomy. The
patients and assessors were blinded to the randomisation both before
and after surgery. The duration of surgery, hospitalisation period,
concealed bleeding, drainage volume, blood transfusion rate and
range of movement of the knee at three days after the operation
were analysed. Patients were followed up at four weeks and 12 months
after their operation, and a visual analogue score (VAS) for pain,
Knee Society score (KSS) and a patellar ballottement test were compared
between the groups. The mean amount of concealed bleeding was higher in the synovectomy
group compared with the control group (1.24 l (0.08 to 3.28) Cite this article:
Pain, swelling and inflammation are expected
during the recovery from total knee arthroplasty (TKA) surgery.
The severity of these factors and how a patient copes with them
may determine the ultimate outcome of a TKA. Cryotherapy and compression
are frequently used modalities to mitigate these commonly experienced
sequelae. However, their effect on range of motion, functional testing,
and narcotic consumption has not been well-studied. A prospective, multi-center, randomised trial was conducted to
evaluate the effect of a cryopneumatic device on post-operative
TKA recovery. Patients were randomised to treatment with a cryopneumatic
device or ice with static compression. A total of 280 patients were
enrolled at 11 international sites. Both treatments were initiated
within three hours post-operation and used at least four times per
day for two weeks. The cryopneumatic device was titrated for cooling
and pressure by the patient to their comfort level. Patients were evaluated by physical therapists blinded to the
treatment arm. Range of motion (ROM), knee girth, six minute walk
test (6MWT) and timed up and go test (TUG) were measured pre-operatively,
two- and six-weeks post-operatively. A visual analog pain score
and narcotic consumption was also measured post-operatively. At two weeks post-operatively, both the treatment and control
groups had diminished ROM and function compared to pre-operatively.
Both groups had increased knee girth compared to pre- operatively.
There was no significant difference in ROM, 6MWT, TUG, or knee girth
between the 2 groups. We did find a significantly lower amount of
narcotic consumption (509 mg morphine equivalents) in the treatment
group compared with the control group (680 mg morphine equivalents)
at up to two weeks postop, when the cryopneumatic device was being
used (p <
0.05). Between two and six weeks, there was no difference
in the total amount of narcotics consumed between the two groups.
At six weeks, there was a trend toward a greater distance walked
in the 6MWT in the treatment group (29.4 meters A cryopneumatic device used after TKA appeared to decrease the
need for narcotic medication from hospital discharge to 2 weeks
post-operatively. There was also a trend toward a greater distance
walked in the 6MWT. Patient satisfaction with the cryopneumatic
cooling regimen was significantly higher than with the control treatment.
The Oxford mobile-bearing unicompartmental knee
replacement (UKR) is an effective and safe treatment for osteoarthritis
of the medial compartment. The results in the lateral compartment
have been disappointing due to a high early rate of dislocation
of the bearing. A series using a newly designed domed tibial component
is reported. The first 50 consecutive domed lateral Oxford UKRs in 50 patients
with a mean follow-up of three years (2.0 to 4.3) were included.
Clinical scores were obtained prospectively and Kaplan-Meier survival
analysis was performed for different endpoints. Radiological variables
related to the position and alignment of the components were measured. One patient died and none was lost to follow-up. The cumulative
incidence of dislocation was 6.2% (95% confidence interval (CI)
2.0 to 17.9) at three years. Survival using revision for any reason
and aseptic revision was 94% (95% CI 82 to 98) and 96% (95% CI 85
to 99) at three years, respectively. Outcome scores, visual analogue
scale for pain and maximum knee flexion showed a significant improvement
(p <
0.001). The mean Oxford knee score was 43 ( Clinical results are excellent and short-term survival has improved
when compared with earlier series. The risk of dislocation remains
higher using a mobile-bearing UKR in the lateral compartment when
compared with the medial compartment. Patients should be informed
about this complication. To avoid dislocations, care must be taken
not to elevate the lateral joint line.