Six highly unstable elbows with severe bone loss due to rheumatoid arthritis were replaced by a non-constrained, unlinked prosthesis. Bone defects were filled with autogenous bone grafts. The mean follow-up was 4.5 years (2 to 8). The clinical results were excellent in four elbows and good in two, with good varus-valgus stability in all. Radiological follow-up showed no appreciable signs of loosening, and the bone grafts had retained most of their original size, with minimal resorption. There were no major complications such as dislocation, skin necrosis, infection or ulnar neuropathy. The study has shown that the so-called mutilans elbow can be successfully replaced
We dissected 21 cadaver elbows to determine the relationship of the posterior interosseous nerve to the posterolateral approach to the elbow and head of the radius. At the distal end of the exposure the first branches at risk, those to extensor carpi ulnaris, were on average 6.0 ± 1.0 cm (4.0 to 8.4) from the articular surface of the radial head. When
The Norway elbow prosthesis is a non-constrained cemented total replacement. It depends on intact collateral ligaments for stability, and allows a full range of movement. The system includes several sizes of components, all freely interchangeable, and semi-constraint can be provided by a locking ring if damaged collateral ligaments make dislocation possible. The prosthesis has been