Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.Aims
Methods
Bicondylar tibial plateau fractures result from
high-energy injuries. Fractures of the tibial plateau can involve
the tibial tubercle, which represents a disruption to the extensor
mechanism and logically must be stabilised. The purpose of this
study was to identify the incidence of an independent tibial tubercle
fracture in bicondylar tibial plateau fractures, and to report management
strategies and potential complications. We retrospectively reviewed
a prospectively collected orthopaedic trauma database for the period
January 2003 to December 2008, and identified 392 bicondylar fractures
of the tibial plateau, in which 85 tibial tubercle fractures (21.6%)
were identified in 84 patients. There were 60 men and 24 women in
our study group, with a mean age of 45.4 years (18 to 71). In 84 fractures
open reduction and internal fixation was undertaken, either with
screws alone (23 patients) or with a plate and screws (61 patients).
The remaining patient was treated non-operatively. In all, 52 fractures
were available for clinical and radiological assessment at a mean
follow-up of 58.5 weeks (24 to 94). All fractures of the tibial
tubercle united, but 24 of 54 fractures (46%) required a secondary
procedure for their tibial plateau fracture. Four patients reported
pain arising from prominent tubercle plates and screws, which in
one patient required removal. Tibial tubercle fractures occurred
in over one-fifth of the bicondylar tibial plateau fractures in
our series. Fixation is necessary and can be reliably performed
with screws alone or with a screw and plate, which restores the
extensor mechanism and facilitates early knee flexion. Cite this article: