Hip hemiarthroplasty is a standard treatment for intracapsular
proximal femoral fractures in the frail elderly. In this study we
have explored the implications of early return to theatre, within
30 days, on patient outcome following hip hemiarthroplasty. We retrospectively reviewed the hospital records of all hip hemiarthroplasties
performed in our unit between January 2010 and January 2015. Demographic
details, medical backround, details of the primary procedure, complications,
subsequent procedures requiring return to theatre, re-admissions,
discharge destination and death were collected.Aims
Patients and Methods
Aims. We conducted a prospective study of a delta ceramic total hip
arthroplasty (THA) to determine the rate of ceramic
Aims. In the initial development of total shoulder arthroplasty (TSA),
the humeral component was usually fixed with cement. Cementless
components were subsequently introduced. The aim of this study was
to compare the long-term outcome of cemented and cementless humeral
components in arthroplasty of the shoulder. Patients and Methods. All patients who underwent primary arthroplasty of the shoulder
at our institution between 1970 and 2012 were included in the study.
There were 4636 patients with 1167 cemented humeral components and
3469 cementless components. Patients with the two types of fixation
were matched for nine different covariates using a propensity score
analysis. A total of 551 well-balanced pairs of patients with cemented
and cementless components were available after matching for comparison
of the outcomes. The clinical outcomes which were analysed included loosening
of the humeral component determined at revision surgery, periprosthetic
fractures, post-operative infection and operating time. Results. The overall five-, ten-, 15- and 20-year rates of survival were
98.9%, 97.2%, 95.5%, and 94.4%, respectively. Survival without loosening
at 20 years was 98% for cemented components and 92.4% for cementless
components. After propensity score matching including fixation as
determined by the design of the component, humeral loosening was
also found to be significantly higher in the cementless group. Survival
without humeral loosening at 20 years was 98.7% for cemented components
and 91.0% for cementless components. There was no significant difference
in the risk of intra- or
To evaluate the hypothesis that failed osteosynthesis of periprosthetic
Vancouver type B1 fractures can be treated successfully with stem
revision using a transfemoral approach and a cementless, modular,
tapered revision stem with reproducible rates of fracture healing,
stability of the revision stem, and clinically good results. A total of 14 patients (11 women, three men) with a mean age
of 72.4 years (65 to 90) undergoing revision hip arthroplasty after
failed osteosynthesis of periprosthetic fractures of Vancouver type
B1 were treated using a transfemoral approach to remove the well-fixed
stem before insertion of a modular, fluted titanium stem which obtained
distal fixation. These patients were clinically and radiologically
followed up for a mean 52.2 months (24 to 144).Aims
Patients and Methods
Our aim was to prepare a systematic review and meta-analysis
to compare the outcomes of cemented and cementless hemiarthroplasty
of the hip, in elderly patients with a fracture of the femoral neck,
to investigate the mortality, complications, length of stay in hospital,
blood loss, operating time and functional results. A systematic review and meta-analysis was conducted following
the Preferred Reporting Items for Systematic Reviews and Meta-Analyses
guidelines on randomised controlled trials (RCTs), studying current
generation designs of stem only. The synthesis of results was done
of pooled data, with a fixed effects or random effects model, based on
heterogeneity.Aims
Materials and Methods
Aims. The aim of this study was to identify patient- and surgery-related
risk factors for sustaining an early periprosthetic fracture following
primary total hip arthroplasty (THA) performed using a double-tapered
cementless femoral component (Bi-Metric femoral stem; Biomet Inc.,
Warsaw, Indiana). Patients and Methods. A total of 1598 consecutive hips, in 1441 patients receiving
primary THA between January 2010 and June 2015, were retrospectively
identified. Level of pre-operative osteoarthritis, femoral Dorr
type and cortical index were recorded. Varus/valgus placement of
the stem and canal fill ratio were recorded post-operatively. Periprosthetic
fractures were identified and classified according to the Vancouver
classification. Regression analysis was performed to identify risk
factors for early periprosthetic fracture. Results. The mean follow-up was 713 days (1 to 2058). A total of 48 periprosthetic
fractures (3.0%) were identified during the follow-up and median
time until fracture was 16 days, (interquartile range 10 to 31.5).
Patients with femoral Dorr type C had a 5.2 times increased risk
of
Periprosthetic femoral fractures (PFF) following total hip arthroplasty
(THA) are devastating complications that are associated with functional
limitations and increased overall mortality. Although cementless
implants have been associated with an increased risk of PFF, the
precise contribution of implant geometry and design on the risk
of both intra-operative and post-operative PFF remains poorly investigated.
A systematic review was performed to aggregate all of the PFF literature
with specific attention to the femoral implant used. A systematic search strategy of several journal databases and
recent proceedings from the American Academy of Orthopaedic Surgeons
was performed. Clinical articles were included for analysis if sufficient
implant description was provided. All articles were reviewed by
two reviewers. A review of fundamental investigations of implant
load-to-failure was performed, with the intent of identifying similar
conclusions from the clinical and fundamental literature.Aims
Patients and Methods
We performed a systematic review of the current literature regarding
the outcomes of unconstrained metacarpophalangeal joint (MCPJ) arthroplasty. We initially identified 1305 studies, and 406 were found to be
duplicates. After exclusion criteria were applied, seven studies
were included. Outcomes extracted included pre- and post-operative
pain visual analogue scores, range of movement (ROM), strength of
pinch and grip, satisfaction and patient reported outcome measures
(PROMs). Clinical and radiological complications were recorded.
The results are presented in three groups based on the design of
the arthroplasty and the aetiology (pyrocarbon-osteoarthritis (pyro-OA),
pyrocarbon-inflammatory arthritis (pyro-IA), metal-on-polyethylene
(MoP)).Aims
Materials and Methods
Fractures of the distal femur are an important cause of morbidity.
Their optimal management remains controversial. Contemporary implants
include angular-stable anatomical locking plates and locked intramedullary
nails (IMNs). We compared the long-term patient-reported functional
outcome of fixation of fractures of the distal femur using these
two methods of treatment. A total of 297 patients were retrospectively identified from
a State-wide trauma registry in Australia: 195 had been treated
with a locking plate and 102 with an IMN. Baseline characteristics
of the patients and their fractures were recorded. Health-related
quality-of-life, functional and radiographic outcomes were compared
using mixed effects regression models at six months and one year.Aims
Patients and Methods
Aim and Methods. The goals of this study were to define the risk factors, nature,
chronology, and treatment strategies adopted for periprosthetic
femoral fractures in 32 644 primary total hip arthroplasties (THAs). . Results. There were 564 intra-operative fractures (1.7%); 529 during uncemented
stem placement (3.0%) and 35 during cemented stem placement (0.23%).
Intra-operative fractures were more common in females and patients
over 65 years (p <
0.001). The majority occurred during placement
of the femoral component (60%), and involved the calcar (69%). There
were 557
The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison. A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison.Objectives
Methods
To compare radiographic failure and re-operation rates of anatomical
coracoclavicular (CC) ligament reconstructional techniques with
non-anatomical techniques after chronic high grade acromioclavicular
(AC) joint injuries. We reviewed chronic AC joint reconstructions within a region-wide
healthcare system to identify surgical technique, complications,
radiographic failure and re-operations. Procedures fell into four
categories: Aims
Patients and Methods
Aims. The goals of this study were to define the risk factors, characteristics,
and chronology of fractures in 5417 revision total hip arthroplasties
(THAs). . Patients and Methods. From our hospital’s prospectively collected database we identified
all patients who had undergone a revision THA between 1969 and 2011
which involved the femoral stem. The patients’ medical records and
radiographs were examined and the relevant data extracted. Post-operative
periprosthetic fractures were classified using the Vancouver system.
A total of 5417 revision THAs were identified. Results. There were 668 intra-operative fractures, giving an incidence
of 12%. Fractures were three times more common with uncemented stems
(19%) than with cemented stems (6%) (p <
0.001). The incidence
of intra-operative femoral fracture varied by uncemented stem type:
fully-coated (20%); proximally-coated (19%); modular fluted tapered
(16%) (p <
0.05). Most fractures occurred during the insertion
of the femoral component (35%). One-third involved the diaphysis
and 26% were of the calcar: 69% were undisplaced. There were 281
Aims. To date, there is insufficient evidence available to compare
the outcome of cemented and uncemented fixation of the humeral stem
in reverse shoulder arthroplasty (RSA). . Methods. A systemic review comprising 41 clinical studies was performed
to compare the functional outcome and rate of complications of cemented
and uncemented stems in RSA. These included 1455 cemented and 329
uncemented shoulders. The clinical characteristics of the two groups
were similar. Variables were compared using pooled frequency-weighted means
and relative risk ratios (RR). Results. Uncemented stems had a significantly higher incidence of early
humeral stem migration (p <
0.001, RR 18.1, 95% confidence interval
(CI) 5.0 to 65.2) and non-progressive radiolucent lines (p <
0.001, RR 2.4, 95% CI 1.7 to 3.4), but a significantly lower incidence
of
Slipped capital femoral epiphysis (SCFE) may
lead to symptomatic femoroacetabular impingement (FAI). We report our
experience of arthroscopic treatment, including osteochondroplasty,
for the sequelae of SCFE. Data were prospectively collected on patients undergoing arthroscopy
of the hip for the sequelae of SCFE between March 2007 and February
2013, including demographic data, radiological assessment of the
deformity and other factors that may influence outcome, such as
the presence of established avascular necrosis. Patients completed
the modified Harris hip score (mHHS) and the non-arthritic hip score
(NAHS) before and after surgery. In total, 18 patients with a mean age of 19 years (13 to 42),
were included in the study. All patients presented with pain in
the hip and mechanical symptoms, and had evidence of FAI (cam or
mixed impingement) on plain radiographs. The patients underwent arthroscopic osteoplasty of the femoral
neck. The mean follow-up was 29 months (23 to 56). The mean mHHS and NAHS scores improved from 56.2 (27.5 to 100.1)
and 52.1 (12.5 to 97.5) pre-operatively to 75.1 (33.8 to 96.8, p
= 0.01) and 73.6 (18.8 to 100, p = 0.02) at final follow-up, respectively.
Linear regression analysis demonstrated a significant association
between poorer outcome scores and increased time to surgery following SCFE
(p <
0.05 for all parameters except baseline MHHS). Symptomatic FAI following (SCFE) may be addressed using arthroscopic
techniques, and should be treated promptly to minimise progressive
functional impairment and chondrolabral degeneration. Take home message: Arthroscopy of the hip can be used to treat
femoroacetabular impingement successfully following SCFE. However,
this should be performed promptly after presentation in order to
prevent irreversible progression and poorer clinical outcomes. Cite this article:
The aim of this randomised controlled study was
to compare functional and radiological outcomes between modern cemented
and uncemented hydroxyapatite coated stems after one year in patients
treated surgically for a fracture of the femoral neck. A total of
141 patients aged >
65 years were included. Patients were randomised
to be treated with a cemented Exeter stem or an uncemented Bimetric
stem. The patients were reviewed at four and 12 months. The cemented group performed better than the uncemented group
for the Harris hip score (78 In conclusion, our data do not support the use of an uncemented
hydroxyapatite coated stem for the treatment of displaced fractures
of the femoral neck in the elderly. Cite this article: