Periprosthetic joint infections (PJIs) and fracture-related infections (FRIs) are associated with a significant risk of adverse events. However, there is a paucity of data on cardiac complications following revision surgery for PJI and FRI and how they impact overall mortality. Therefore, this study aimed to investigate the risk of perioperative myocardial injury (PMI) and mortality in this patient cohort. We prospectively included consecutive patients at high cardiovascular risk (defined as age ≥ 45 years with pre-existing coronary, peripheral, or cerebrovascular artery disease, or any patient aged ≥ 65 years, plus a postoperative hospital stay of > 24 hours) undergoing septic or aseptic major orthopaedic surgery between July 2014 and October 2016. All patients received a systematic screening to reliably detect PMI, using serial measurements of high-sensitivity cardiac troponin T. All-cause mortality was assessed at one year. Multivariable logistic regression models were applied to compare incidence of PMI and mortality between patients undergoing septic revision surgery for PJI or FRI, and patients receiving aseptic major bone and joint surgery.Aims
Methods
Aims. The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods. Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm. 3. and ≥ 65% for TKA and ≥ 3,000 cells/mm. 3. and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in
We investigated whether the indentation of bone
cement spacers used in revision of infected joint arthroplasty with a
MacDonald dissector increased the elution of antibiotic The fluid sampled at 72 hours from the indented discs containing
0.17 g gentamicin (0.88% w/w) contained a mean of 113 mcg/ml (90.12
to 143.5) compared with 44.5 mcg/ml (44.02 to 44.90) in the fluid
sampled from the plain discs (p = 0.012). In discs containing 0.33
g gentamicin (1.75% w/w), the concentration eluted from the indented discs
at 72 hours was a mean of 316 mcg/ml (223 to 421) compared with
a mean of 118 mcg/ml (100 to 140) from the plain discs (p <
0.001). At two weeks, these significant differences persisted. At nine
weeks the indented discs eluted a greater concentration for all
gentamicin doses, but the difference was only significant for the
discs containing 0.17 g (0.88% w/w, p = 0.006). However if the area
under the curve is taken as a measure of the total antibiotic eluted,
the indented discs eluted more gentamicin than the plain discs for
the 0.17 g (0.88% w/w, p = 0.031), the 0.25 g (1.41% w/w, p <
0.001) and the 0.33 g (1.75% w/w, p <
0.001) discs. When preparing antibiotic spacers for use in staged revision
arthroplasty surgery we recommend indenting the spacer with a MacDonald
dissector to increase the elution of antibiotic. Cite this article:
We have assessed the different adhesive properties
of some of the most common bacteria associated with periprosthetic
joint infection on various types of ultra high molecular Weight
Polyethylene (UHMWPE). Quantitative Cite this article:
The purpose of this study was to compare the
diagnostic accuracy for the detection of infection between the culture of
fluid obtained by sonication (SFC) and the culture of peri-implant
tissues (PITC) in patients with early and delayed implant failure,
and those with unsuspected and suspected septic failure. It was
hypothesised that SFC increases the diagnostic accuracy for infection
in delayed, but not early, implant failure, and in unsuspected septic
failure. The diagnostic accuracy for infection of all consecutive
implants (hardware or prostheses) that were removed for failure was
compared between SFC and PITC. This prospective study included 317
patients with a mean age of 62.7 years (9 to 97). The sensitivity
for detection of infection using SFC was higher than using PITC
in an overall comparison (89.9% Sonication is mainly recommended when there is implant failure
with no clear signs of infection and in patients with delayed implant
failure. In early failure, SFC is not superior to PITC for the diagnosis
of infection and, therefore, is not recommended as a routine diagnostic
test in these patients. Cite this article: