Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 734 - 738
1 Apr 2021
Varshneya K Jokhai R Medress ZA Stienen MN Ho A Fatemi P Ratliff JK Veeravagu A

Aims

The aim of this study was to identify the risk factors for adverse events following the surgical correction of cervical spinal deformities in adults.

Methods

We identified adult patients who underwent corrective cervical spinal surgery between 1 January 2007 and 31 December 2015 from the MarketScan database. The baseline comorbidities and characteristics of the operation were recorded. Adverse events were defined as the development of a complication, an unanticipated deleterious postoperative event, or further surgery. Patients aged < 18 years and those with a previous history of tumour or trauma were excluded from the study.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1375 - 1383
3 Oct 2020
Zhang T Sze KY Peng ZW Cheung KMC Lui YF Wong YW Kwan KYH Cheung JPY

Aims

To investigate metallosis in patients with magnetically controlled growing rods (MCGRs) and characterize the metal particle profile of the tissues surrounding the rod.

Methods

This was a prospective observational study of patients with early onset scoliosis (EOS) treated with MCGRs and undergoing rod exchange who were consecutively recruited between February 2019 and January 2020. Ten patients were recruited (mean age 12 years (SD 1.3); 2 M:8 F). The configurations of the MCGR were studied to reveal the distraction mechanisms, with crucial rod parts being the distractable piston rod and the magnetically driven rotor inside the barrel of the MCGR. Metal-on-metal contact in the form of ring-like wear marks on the piston was found on the distracted portion of the piston immediately outside the barrel opening (BO) through which the piston rod distracts. Biopsies of paraspinal muscles and control tissue samples were taken over and away from the wear marks, respectively. Spectral analyses of the rod alloy and biopsies were performed to reveal the metal constituents and concentrations. Histological analyses of the biopsies were performed with haematoxylin and eosin staining.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1359 - 1367
3 Oct 2020
Hasegawa K Okamoto M Hatsushikano S Watanabe K Ohashi M Vital J Dubousset J

Aims

The aim of this study is to test the hypothesis that three grades of sagittal compensation for standing posture (normal, compensated, and decompensated) correlate with health-related quality of life measurements (HRQOL).

Methods

A total of 50 healthy volunteers (normal), 100 patients with single-level lumbar degenerative spondylolisthesis (LDS), and 70 patients with adult to elderly spinal deformity (deformity) were enrolled. Following collection of demographic data and HRQOL measured by the Scoliosis Research Society-22r (SRS-22r), radiological measurement by the biplanar slot-scanning full body stereoradiography (EOS) system was performed simultaneously with force-plate measurements to obtain whole body sagittal alignment parameters. These parameters included the offset between the centre of the acoustic meatus and the gravity line (CAM-GL), saggital vertical axis (SVA), T1 pelvic angle (TPA), McGregor slope, C2-7 lordosis, thoracic kyphosis (TK), lumbar lordosis (LL), pelvic incidence (PI), PI-LL, sacral slope (SS), pelvic tilt (PT), and knee flexion. Whole spine MRI examination was also performed. Cluster analysis of the SRS-22r scores in the pooled data was performed to classify the subjects into three groups according to the HRQOL, and alignment parameters were then compared among the three cluster groups.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 627 - 631
1 May 2020
Mahon J Ahern DP Evans SR McDonnell J Butler JS

Aims

The timing of surgical fixation in spinal fractures is a contentious topic. Existing literature suggests that early stabilization leads to reduced morbidity, improved neurological outcomes, and shorter hospital stay. However, the quality of evidence is low and equivocal with regard to the safety of early fixation in the severely injured patient. This paper compares complication profiles between spinal fractures treated with early fixation and those treated with late fixation.

Methods

All patients transferred to a national tertiary spinal referral centre for primary surgical fixation of unstable spinal injuries without preoperative neurological deficit between 1 July 2016 and 20 October 2017 were eligible for inclusion. Data were collected retrospectively. Patients were divided into early and late cohorts based on timing from initial trauma to first spinal operation. Early fixation was defined as within 72 hours, and late fixation beyond 72 hours.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 395 - 401
1 Mar 2016
Helenius I Keskinen H Syvänen J Lukkarinen H Mattila M Välipakka J Pajulo O

Aims. In a multicentre, randomised study of adolescents undergoing posterior spinal fusion for idiopathic scoliosis, we investigated the effect of adding gelatine matrix with human thrombin to the standard surgical methods of controlling blood loss. Patients and Methods. Patients in the intervention group (n = 30) were randomised to receive a minimum of two and a maximum of four units of gelatine matrix with thrombin in addition to conventional surgical methods of achieving haemostasis. Only conventional surgical methods were used in the control group (n = 30). We measured the intra-operative and total blood loss (intra-operative blood loss plus post-operative drain output). Results. Each additional hour of operating time increased the intra-operative blood loss by 356.9 ml (p < 0.001) and the total blood loss by 430.5 ml (p < 0.001). Multiple linear regression analysis showed that the intervention significantly decreased the intra-operative (-171 ml, p = 0.025) and total blood loss (-177 ml, p = 0.027). The decrease in haemoglobin concentration from the day before the operation to the second post-operative day was significantly smaller in the intervention group (-6 g/l, p = 0.013) than in the control group. . Conclusion. The addition of gelatine matrix with human thrombin to conventional methods of achieving haemostasis reduces both the intra-operative blood loss and the decrease in haemoglobin concentration post-operatively in adolescents undergoing posterior spinal fusion for idiopathic scoliosis. Take home message: A randomised clinical trial showed that gelatine matrix with human thrombin decreases intra-operative blood loss by 30% when added to traditional surgical haemostatic methods in adolescents undergoing posterior spinal fusion for idiopathic scoliosis. Cite this article: Bone Joint J 2016;98-B:395–401


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1442 - 1447
1 Nov 2012
Sharma H Lee SWJ Cole AA

Spinal stenosis and disc herniation are the two most frequent causes of lumbosacral nerve root compression. This can result in muscle weakness and present with or without pain. The difficulty when managing patients with these conditions is knowing when surgery is better than non-operative treatment: the evidence is controversial. Younger patients with a lesser degree of weakness for a shorter period of time have been shown to respond better to surgical treatment than older patients with greater weakness for longer. However, they also constitute a group that fares better without surgery. The main indication for surgical treatment in the management of patients with lumbosacral nerve root compression should be pain rather than weakness.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 93 - 97
1 Jan 2012
Lee JH Lee J Park JW Shin YH

In patients with osteoporosis there is always a strong possibility that pedicle screws will loosen. This makes it difficult to select the appropriate osteoporotic patient for a spinal fusion. The purpose of this study was to determine the correlation between bone mineral density (BMD) and the magnitude of torque required to insert a pedicle screw. To accomplish this, 181 patients with degenerative disease of the lumbar spine were studied prospectively. Each underwent dual-energy x-ray absorptiometry (DEXA) and intra-operative measurement of the torque required to insert each pedicle screw. The levels of torque generated in patients with osteoporosis and osteopenia were significantly lower than those achieved in normal patients. Positive correlations were observed between BMD and T-value at the instrumented lumbar vertebrae, mean BMD and mean T-value of the lumbar vertebrae, and mean BMD and mean T-value of the proximal femur. The predictive torque (Nm) generated during pedicle screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar vertebrae)], as measured by linear regression analysis. The positive correlation between BMD and the maximum torque required to insert a pedicle screw suggests that pre-operative assessment of BMD may be useful in determining the ultimate strength of fixation of a device, as well as the number of levels that need to be fixed with pedicle screws in patients who are suspected of having osteoporosis


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 650 - 657
1 May 2011
Hasegawa K Shimoda H Kitahara K Sasaki K Homma T

We examined the reliability of radiological findings in predicting segmental instability in 112 patients (56 men, 56 women) with a mean age of 66.5 years (27 to 84) who had degenerative disease of the lumbar spine. They underwent intra-operative biomechanical evaluation using a new measurement system. Biomechanical instability was defined as a segment with a neutral zone > 2 mm/N. Risk factor analysis to predict instability was performed on radiographs (range of segmental movement, disc height), MRI (Thompson grade, Modic type), and on the axial CT appearance of the facet (type, opening, vacuum and the presence of osteophytes, subchondral erosion, cysts and sclerosis) using multivariate logistic regression analysis with a forward stepwise procedure. The facet type was classified as sagittally orientated, coronally orientated, anisotropic or wrapped.

Stepwise multivariate regression analysis revealed that facet opening was the strongest predictor for instability (odds ratio 5.022, p = 0.009) followed by spondylolisthesis, MRI grade and subchondral sclerosis. Forward stepwise multivariate logistic regression indicated that spondylolisthesis, MRI grade, facet opening and subchondral sclerosis of the facet were risk factors. Symptoms evaluated by the Short-Form 36 and visual analogue scale showed that patients with an unstable segment were in significantly more pain than those without. Furthermore, the surgical procedures determined using the intra-operative measurement system were effective, suggesting that segmental instability influences the symptoms of lumbar degenerative disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 622 - 628
1 May 2008
Mariconda M Galasso O Secondulfo V Cozzolino A Milano C

We have studied 180 patients (128 men and 52 women) who had undergone lumbar discectomy at a mean of 25.4 years (20 to 32) after operation. Pre-operatively, most patients (70 patients; 38.9%) had abnormal reflexes and/or muscle weakness in the leg (96 patients; 53.3%). At follow-up 42 patients (60%) with abnormal reflexes pre-operatively had fully recovered and 72 (75%) with pre-operative muscle impairment had normal muscle strength. When we looked at patient-reported outcomes, we found that the Short form-36 summary scores were similar to the aged-matched normative values. No disability or minimum disability on the Oswestry disability index was reported by 136 patients (75.6%), and 162 (90%) were satisfied with their operation. The most important predictors of patients’ self-reported positive outcome were male gender and higher educational level. No association was detected between muscle recovery and outcome.

Most patients who had undergone lumbar discectomy had long-lasting neurological recovery. If the motor deficit persists after operation, patients can still expect a long-term satisfactory outcome, provided that they have relief from pain immediately after surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 508 - 512
1 Apr 2005
Lafuente J Casey ATH Petzold A Brew S

We present data relating to the Bryan disc arthroplasty for the treatment of cervical spondylosis in 46 patients.

Patients with either radiculopathy or myelopathy had a cervical discectomy followed by implantation of a cervical disc prosthesis. Patients were reviewed at six weeks, six months and one year and assessment included three outcome measures, a visual analogue scale (VAS), the short form 36 (SF-36) and the neck disability index (NDI). The results were categorised according to a modification of Odom’s criteria. Radiological evaluation, by an independent radiologist, sought evidence of movement, stability and subsidence of the prosthesis.

A highly significant difference was found for all three outcome measurements, comparing the pre-operative with the post-operative values: VAS (Z = 6.42, p < 0.0001), SF-36 (mental component) (Z = −5.02, p < 0.0001), SF-36 (physical component) (Z = −5.00, p < 0.0001) and NDI (Z = 7.03, p < 0.0001). The Bryan cervical disc prosthesis seems reliable and safe in the treatment of patients with cervical spondylosis.