Patients undergoing femoral lengthening by external fixation
tolerate treatment less well when compared to tibial lengthening.
Lengthening of the femur with an intramedullary device may have
advantages. We reviewed all cases of simple femoral lengthening performed
at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities,
congenital limb deficiencies and lengthening with an unstable hip
were excluded, leaving 33 cases (in 22 patients; 11 patients had
bilateral procedures) for review. Healing index, implant tolerance
and complications were compared.Aims
Patients and Methods
We compared lower limb coronal alignment measurements
obtained pre- and post-operatively with long-leg radiographs and
computer navigation in patients undergoing primary total knee replacement
(TKR). A series of 185 patients had their pre- and post-implant
radiological and computer-navigation system measurements of coronal alignment
compared using the Bland-Altman method. The study included 81 men
and 104 women with a mean age of 68.5 years (32 to 87) and a mean
body mass index of 31.7 kg/m2 (19 to 49). Pre-implant
Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability
coefficient of 9.0°. The Bland–Altman plot showed a tendency for the
radiological measurement to indicate a higher level of pre-operative
deformity than the corresponding navigation measurement. Post-implant
limits of agreement were -5.0° to 5.4° with a repeatability coefficient
of 5.2°. The tendency for valgus knees to have greater deformity
on the radiograph was still seen, but was weaker for varus knees. The alignment seen or measured intra-operatively during TKR is
not necessarily the same as the deformity seen on a standing long-leg
radiograph either pre- or post-operatively. Further investigation
into the effect of weight-bearing and surgical exposure of the joint
on the mechanical femorotibial angle is required to enable the most appropriate
intra-operative alignment to be selected.
Incomplete avulsion of the proximal hamstrings
can be a severely debilitating injury that causes weakness, pain
while sitting and inability to run. The results of the surgical treatment
of 23 consecutive patients with such injuries at least two years
after surgery are described. The surgery consisted of the repair
of the hamstrings directly onto the ischial tuberosity. At review,
using a visual analogue scale (VAS, 0 to 100), pain while sitting improved
from a mean of 40 (0 to 100) to 64 (0 to 100) (p = 0.024), weakness
from a mean of 39 (0 to 90) to 76 (7 to 100) (p = 0.0001) and the
ability to run from a mean of 24 (0 to 88) to 64 (0 to 95) (p =
0.0001). According to a VAS, satisfaction was rated at a mean of
81 (0 to 100) and 20 patients (87%) would have the same procedure
again. Hamstring strength measured pre- and post-operatively had
improved significantly from a mean of 64% (0% to 95%) to 88% (50%
to 114%) compared with the normal side. Most of these patients with symptomatic incomplete hamstring
avulsions unresponsive to conservative treatment had an improved
outcome after surgical repair.
We The triple-strand technique significantly increased the tensile
strength (p = 0.0001) and gap resistance (p = 0.01) of bovine tendon
repairs, and might have advantages in human application for accelerated
post-operative rehabilitation.
The use of autograft bone is the best option
when undertaking a procedure that requires bone graft because it
is osteogenic, osteoconductive and osseo-inductive. Pain, morbidity
and complications associated with harvesting iliac or non-iliac
sites occur in between 6% and 30% of cases. An alternative source
of graft with possibly a lower morbidity is the intramedullary canal.
In this study, 28 patients undergoing 30 arthrodesis procedures
on the hindfoot had a mean of 48 cm3 (43 to 50) of bone
harvested locally from the hindfoot or the tibial shaft by antegrade or
retrograde reaming. No patient sustained a fracture of the calcaneum,
talus or tibia. There was no morbidity except for one complication
when the reamer breached the medial tibial cortex. This healed uneventfully. This method of using the reamer–irrigator–aspirator system is
an extension of the standard technique of intramedullary reaming
of the lower limb: it produces good-quality bone graft with viable
growth factors consistent with that of the iliac crest, and donor
site morbidity is low. This is an efficient method of obtaining
autologous bone for use in arthrodesis of the ankle or hindfoot.